Introduction
Dear Customer,
Thank you for purchasing this Instanta product.
Your new water boiler is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed.
All new series Instanta products are energy
efcient, simple to operate and easy to service.
Find out more about Instanta products at www. instanta.com
Safety Information
Please read the following carefully before starting work on this equipment.
A competent person should install this appliance in accordance with the installation instructions for this appliance and all relevant local and national standards including the following:
Health & Safety at Work Act
IEE Regulations
Local & national Building Regulations
BS Codes of practice
Water Supply Regulations
All personnel should be provided with sufcient
training in the safe use of this appliance. A warning notice displayed next to the machine is often helpful in notifying users that the appliance contains and dispenses near boiling water.
Inform users that certain surfaces will become hot (especially the draw-off tap). Care should be taken to avoid potential injury from burns and scalding whilst operating this appliance.
In line with Health and Safety requirements we recommend a risk assessment be carried out after the boiler has been installed.
Always disconnect the unit from the power supply before servicing.
The unit must be earthed.
Keep these instructions in a safe place near
the unit for future reference.
2
Environmental (Information On Disposal For Users Of Waste Electrical & Electronic Equipment)
The “crossed out wheelie bin” symbol on this product means that discarded electrical and electronic products should not be mixed with general waste. Disposing of the product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For proper treatment, recovery and recycling of end-of-life products, please contact your dealer or supplier for further information, or local authority for details of your nearest designated collection point.
Delivery Checklist
Before starting installation, check that you have the following parts;
Catering Water Boiler
Drip-tray
Drip-tray tting kit
White water inlet hose (3/4”BSP connection)
User instructions
Technical Specification
Model 1501F 3001F
Width mm 252 308
Depth mm 362 362
Height mm 610 618
Power Rating KW 3.0 3.0
Weight (Empty) KG 13.5 15.5
Weight (Full) KG 28 36
Water Inlet Pressure: Bar 2 to 7 2 to 7
Installation
The boiler must be installed on a horizontal work
surface with sufcient strength to support its
weight.
Locate in an area where there is adequate space to use the boiler safely (e.g. free from risk of congestion and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water lling hose
(3/4”BSP) to the inlet connection point on the back of the boiler and the other end to the mains water supply, via an accessible isolating tap with a ¾”BSP thread.
IMPORTANT: If micro-bore pipe is used instead of the inlet hose supplied, the size must be minimum OD 3/8”(10mm).
The water supply must have a pressure not exceeding 7bar (96psi), and no lower than 2bar (20psi) NOTE: If your water pressure exceeds
7bar, t a suitable pressure reduction valve.
We regret that Instanta cannot be held responsible for any machine malfunctions if the water pressure exceeds that stated. If in doubt, consult your water supply company.
Electrical Connection:
The boiler must be Earthed.
Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse.
Overflow:
The drip-tray has a limited capacity and is designed to handle small spillages and drips. Wherever possible, we strongly recommend that it is connected to a permanent waste outlet
using the tting kit provided.
If preferred, and as an alternative, the overow
can be connected from the back of the
machine using an optional rear-overow kit
(Pt. No: ROFK1) available from Instanta Spares Department (01704 502905).
IMPORTANT: Whichever overow connection is
chosen, the diameter of the pipe used must be no less than 15mm.
Whilst every reasonable precaution is taken to prevent an overflow, Instanta cannot be held responsible for any damage caused as a result of incorrect installation or blockage of the overflow or failure to direct the overflow to a safe outlet.