Inovonics Wireless 3B6ETRT2M Users manual

DS200 Key Chain Remote Control
WARNING: Read and understand all instructions and warnings for this product. In addition, read and follow all
instructions and warnings provided with the DS100 JobSite Security Portable Alarm System.
CAUTION: DANGER OF EXPLOSION, INJURY OR FIRE.
Carefully follow all instructions and warnings on the battery label and package.
• Discharged batteries should be replaced only with type CR-2 3.0 Volt Lithium batteries.
• Do not use re-chargeable batteries or attempt to charge batteries.
• Carefully remove the old, discharged battery.
• Do not attempt to open.
• Do not peel the label from the battery.
• Never dispose of a battery in a fire.
• Dispose of used batteries in accordance with local regulations.
• Recycle batteries.
• Always insert batteries correctly with regard to polarity (+ and -) marked on the battery and the equipment.
• When installing the battery, do not use excessive force. If the bat­tery does not fit, check to make sure that it matches the polarity markings.
• Never expose the battery terminals to any other metal object. This can short circuit the battery.
• Avoid exposure to temperature extremes.
• When not in use, store the battery in a cool, dark, dry place.
• Keep batteries out of reach of children.
CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Do not use near water. Damage to the equipment may
occur. Equipment shall not be exposed to liquids.
FCC REGULATORY STATEMENT (FCC: HCQ3B6ETRT2M)
• This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) the device must accept any interference received, including interference that may cause unde­sired operation.
INDUSTRY CANADA (IC: 2309A-ETRT2M)
NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the reg­istration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
Components (Fig. 1, 2)
A. Antenna E. Battery B. LED F. Reset Button C. Lock Button G. Carabiner D. Unlock Button
Product Function
The DS200 Key Chain Remote Control is used for arming or disarming the system from a range of up to 2000' (610 m).
Once activated, this device will work exclusively with the assigned DS100 JobSite Security Portable Alarm System.
• The remote uses 900 MHz spread spectrum communication to provide superior range and robustness.
• The DS200 has an LED feedback light which notifies the user when a signal is being sent to the Base Unit.
LOCK (C) – press and release to arm the system.
UNLOCK (D) – press and release to disarm the system.
• The DS200 remote uses a CR-2 3.0V Lithium battery (E) for long life.
• The reset button (F) allows the Key Chain Remote Control to be registered to any D
EWALT JobSite Security system with easy
set up.
• A convenient carabiner clip (G) is included for versatility.
NOTE: Metal objects blocking radio frequency (RF) transmission can affect the range of the Key Chain Remote.
Prevention of False Alarms
The majority of alarms that occur are false. These situations happen every day due to user error, incorrect installation or improper mainte­nance of the system. False alarms will limit the responsiveness to the system, and become a general inconvenience. As the number of false alarms increases, authorities have become less apt to respond to alarm systems due to this problem. Many of these situations can be avoided by following some very simple practices.
• Ensure all users are properly trained on the operation of the system.
• Always turn off the system with the Key Chain Remote Control before entering protected area.
• Lock all protected doors, windows or any other asset attached to a sensor.
• Check that motion detectors are not obstructed. Do not allow sources of heat or sound in range of the motion or vibration sen­sors.
• Check that premises are cleared and assets secured before setting the system.
• Turn off all noise sources – radios, compressors, generators, heavy equipment, etc.
• Know how to cancel an alarm or turn off the system before activating.
• If a false alarm is tripped notify customer service immediately.
• Test the system on a monthly basis to ensure proper functioning
• Check cellular signal, power supply, and that sensors are secured on a daily basis.
Recommended Uses
The DS200 Key Chain Remote Control is useful for arming and disarming the system without typing a user code on the keypad. Up to 6 Key Chain Remotes can be added to the system.
Installing & Changing Battery
The DS200 Key Chain Remote Control requires a non-rechargeable CR-2 3.0 Volt Lithium battery.
CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Do not touch the electronic components inside the
device, except the reset button and battery.
SITELOCK LLC, 626 Hanover Pike, Hampstead, MD 21074 (SEP04) Form No. 626133-00 DS200 Copyright © 2004 DEWALT
CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Do not touch the electronic components
inside the device, except the reset button and battery.
A
B
C
D
E
F
G
FIG. 1 FIG. 3FIG. 2
2
TO INSTALL A BATTERY
1. Using a flat screwdriver, open the housing. Insert the screwdriver about .25" (6mm) at the tab on the top of the unit (Fig. 3). Pry downward on the handle of the screwdriver until the latch holding the cover to the housing base releases.
2. Install the battery using the polarity (+ and -) markings on the battery and equipment. Do not use excessive force. If the battery does not fit, ensure that it matches the polarity markings (Fig. 2).
3. Press the reset button (F) on the device. After resetting the Key Chain Remote (see Device Registration), replace the cover.
TO CHANGE THE BATTERY
CAUTION: Never use a damaged or worn out battery.
1. Carefully remove the old, discharged battery. Dispose of the battery according to local regulations.
2. Install new battery using the polarity (+ and -) markings on the battery and equipment. Do not use excessive force. If the battery does not fit, ensure that it matches the polarity markings (Fig. 2).
3. Press the reset button (F) on the device to re-register the sensor and restore programming. After resetting the Key Chain Remote, replace the cover.
Device Registration
To activate the remote, it must first be assigned to your DS100 Base Unit. Refer to the DS100 JobSite Security Portable Alarm System Instruction Manual for more details on registering a device during the initial setup.
NOTE: The system must be disarmed prior to any programming changes.
1. Press the MAIN MENU button on the keypad of the DS100 Base Unit.
2. Using the keypad, enter the master code.
3. Use the up and down arrows to scroll through the menu until the System Settings menu is displayed. Select OK.
4. Use the up and down arrows to scroll through the menu until the Wireless Device Maintenance menu is displayed. Select OK.
5. Use the up and down arrows to scroll through the menu until the Add/Replace Device screen is displayed. Select OK.
6. The next available device number will be displayed. Up to six Key Chain Remotes can be registered to the system. If there are no slots available, the screen will display ALL DEVICES IN USE. When the device number is shown, select OK.
7. Using a flat screwdriver, open the housing. Insert the screwdriver about .25" (6 mm) at the tab on the top of the unit. Pry upward on the handle of the screwdriver until the latch holding the cover to the housing base releases (Figure 3).
8. When prompted by the LCD screen to RESET DEVICE, press and release the reset button (F) located on the control board. The screen will indicate that the device has been registered.
9. Snap the cover into place.
10. To edit the description of the device, select EDIT.
11. To edit the description, use the keypad to type a description of up to 8 characters. The character that is being changed will be under­lined. To move back a character, use the left/down arrow. To move forward a character, use the right/up arrow. When complete, select SAVE.
IMPORTANT: Write the device description and corresponding device number on the Sensor Location List included with the DS100 JobSite Security Portable Alarm System. Keep this sheet for reference. This information will be needed during the monitoring service enrollment process. As device changes are made, be sure to contact D
EWALT customer service to make adjustments to the
monitoring service.
12. After registration, test the remote. If programming through the initial setup, the test function will be included in the setup sequence. If adding the Key Chain Remote after the alarm system has been programmed, use the TEST button on the keypad.
Walk Test
To activate the Key Chain Remote Control during a walk test, press the lock ( ) button on the remote. The Base Unit will indicate that the test was successful when the device is removed from the list on the LCD screen.
IMPORTANT: To prevent false alarms, be sure to have a good under­standing of the range of the system for arming and disarming.
To test the range of the Key Chain Remote, perform the walk test from any area throughout the job site that may be used as an entry or exit point.
Faults
Faults indicate when there has been a serious issue that needs to be addressed. This could be a number of things including a low battery or weak signal.
If a fault is present, the system will chime and the Fault screen will be displayed. To silence the chime, select SILENCE. To display the fault and resolve immediately, select DISPLAY. Use the up and down arrows to scroll through the faults. Resolve the issue with the action listed in Description of Fault Codes chart.
Full One Year Warranty
The DEWALT JobSite Security Portable Alarm System is warranted for one year from date of purchase. We will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, visit www.dewalt.com or call 1-800-4-D
EWALT
(1-800-433-9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by oth­ers. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces.
Fault Code Fault Display Description Action
DevPower Primary Power No battery power Change battery,
Lost Device # in device reset
DevLowBatt Low Battery Device battery Change battery,
Device # low reset
DESCRIPTION OF FAULT CODES
Télécommande porte-clé DS200
AVERTISSEMENT : Lire et comprendre tout avertissement et toute instruction inclus dans ce manuel. De plus lire, tout
avertissement et toute instruction fournis avec le Système d’alarme mobile de sécurité des chantiers DS100.
MISE EN GARDE : RISQUES D’EXPLOSION, DE BLESSURE
OU D’INCENDIE. Suivre attentivement toute instruction ou tout aver-
tissement inclus sur l’étiquette ou l’emballage des piles.
• Ne jamais utiliser une pile endommagée ou usée.
• Les piles déchargées doivent être remplacées par des piles au lithi­um de type CR-2 de 3,0 volts.
• Ne pas utiliser de piles rechargeables ou tenter de recharger les piles.
• Retirer soigneusement la vieille pile déchargée.
• Ne pas chercher à l’ouvrir.
• Ne pas retirer l’étiquette d’une pile.
• Ne jamais mettre une pile au feu.
• S’en défaire conformément aux régulations locales.
• Recycler les piles.
• Lors de l’installation des piles, toujours respecter la polarité (+ et -) inscrite sur les piles et l’appareil.
• Ne pas forcer excessivement pour installer des piles. Si la pile ne rentre pas, vérifier que la polarité des bornes cadre avec les mar­ques sur l’appareil.
• Ne jamais mettre les bornes des piles en contact avec tout autre objet métallique. Cela pourrait provoquer un court circuit.
• Éviter de les exposer à des températures extrêmes.
• Après utilisation, entreposer les piles dans un lieu frais, sombre et sec.
• Conserver les piles hors de la portée des enfants.
MISE EN GARDE : RISQUES DE MAUVAIS FONCTIONNEMENT OU DE DÉFAILLANCE. Ne pas utiliser à proximité d’eau. L’appareil
risquerait d’être endommagé. Protéger l’appareil de tout liquide.
Loading...