INOR MinIPAQ-L-USB Data Sheet

19
19
MIN
T/C
RTD
-
RTD
-
SPECIALISTS IN INDUSTRIAL TEMPERATURE MEASUREMENT
35/1.38
17.5/0.69
68/2.68
63/2.48
98/3.86
45/1.77
IPAQ-L
Basic Programmable 2-wire Transmitter
MIN
IPAQ-L is a basic, programmable non-isolated, easy-to-use 2-wire transmitter. Conguration is made in seconds with the user friendly Windows software. No external power supply required for conguration.
MIN
IPAQ-L is programmable for RTD’s in 3- and 4-wire connection according to different standards as well as for 11 T/C types. Useful error correction functions improve the accuracy.
• Accepts RTD in 3- and 4-wire connection and 11 T/C types
• Temperature linear output
• Sensor error and system (sensor/transmitter) error correction for highest total accuracy
• Conguration without external power
• Easy-to-use Windows conguration software
• NAMUR compliant
• Test output without breaking the loop
• USB communication
• Withstands vibrations up to 10 g
Input connections
Output connections
I
OUT
R
LOAD
Output load diagram
R
()
LOAD
RTD
3-wire connection
RTD
4-wire connection
Thermocouple
1)
Test
1)
Ri 10
Specications:
Input RTD 3-, 4-wire connection Pt100 (
α
=0.00385) -200 to +1000 °C / -328 to +1832 °F
Pt1000 (
α
=0.00385) -200 to +200 °C / -328 to +392 °F PtX 10 X 1000 ( Pt100 (
α
=0.003902) -200 to +1000 °C / -328 to +1832 °F
Pt100 (
α
=0.003916) -200 to +1000 °C / -328 to +1832 °F
2)
Ni100
-60 to +250 °C / -76 to +482 °F
2)
Ni1000
-10 to +150 °C / +14 to +302 °F
3)
Ni120
4)
Cu10
Input Thermocouples
Types B, C, E, J, K, L, N, R, S, T, U
Sensor failure Upscale, downscale or off Adjustments - Zero Any value within range limits Adjustments - Minimum spans
Pt100, Pt1000, Ni100, Ni1000 10 °C /18 °F T/C 2 mV
Output 4-20 mA, temperature linear Operating temperature -20 to +70 °C / -4 to +158 °F Galvanic isolation No Power supply 8 to 32 VDC Typical accuracy ±0.15 % of temperature span Mounting Rail acc. to DIN EN 50022, 35 mm
1)
IEC 60751,
α
=0.00385) Upper range depending on X-value
-70 to +300 °C / -94 to +572 °F
-200 to +260 °C / -328 to +500 °F
2)
DIN 43760,
3)
Edison No.7,
4)
Edison No.15
Supply voltage U (V DC)
R
=(U-8)/0.022
LOAD
Dimensions
mm/inch
Ordering information
MIN
IPAQ-L 70MQL00003 PC Conguration Kit (USB conn.) 70CFGUS001 Conguration 70CAL00001
Loading...