INOR MinIPAQ-HLP-USB Data sheet

MIN
IPAQ-HLP
Low Prole
Programmable 2-wire Transmitter for RTD and T/C
MIN
IPAQ-HLP is a basic, non-isolated, easy-to-use 2-wire transmitter for in-head mounting in DIN B and
similar heads. Reduced hight simplies mounting in low connection heads. Conguration is made in seconds with the user friendly Windows software,
power is needed.
MIN
IPAQ-HLP is programmable for RTD’s in 3- and 4-wire connection as well as for 11 T/C types.
Useful error correction functions improve the accuracy.
MIN
IPAQ Soft. No external
Measurements with RTD’s in 3- and 4-wire connection
MIN
IPAQ-HLP accepts inputs from a number of standardized RTD’s such as Pt100, Pt500 and Pt1000 acc. to IEC 60751 (α=0.00385), Pt100 acc. to JIS C 1604 (α=0.003916) and US standards (α=0.003902), Ni100 and Ni1000 acc. to DIN 43760 as well as Ni120 and Cu10 acc. to Edison curves. 3- and 4-wire connection can be selected.
Measurements with Thermocouples
MIN
IPAQ-HLP accepts inputs from 11 types of standardized Thermocouples. For T/C input, the CJC (Cold Junction Compensation) is fully automatic, by means of an accurate measurement of the terminal temperature. Alternatively, the CJC can be disabled.
Temperature linear output
Fully temperature linear 4-20 mA output for RTD’s and Thermocouples.
Designed for harsh conditions
Rugged design tested for 10 g vibrations.
NAMUR compliant
Output limitations and fail currents according to NAMUR recommendations.
Sensor matching and error corrections for maximum accuracy
A matching to a calibrated temperature sensor can easily be performed with the function. The
System Error Compensation
the sensor/transmitter combination (or just the transmitter) for highest accuracy in a certain measuring range.
Sensor Error Compensation
is a convenient way to adjust
Mounting, wiring and testing
MIN
IPAQ-HLP is designed to t inside connection heads type
DIN B or larger. The large center hole, dia. 7 mm / 0.28 inch, the robust terminals with test connections and the low hight greatly simplify the mounting, wiring and testing procedure.
Conguration without external power
Edit or read the conguration off-line by just connecting to the USB
port of a PC.
MIN
IPAQ Soft, easy-to-use Windows conguration
software
The simple and user friendly software,
for transmitter conguration in seconds. In one window all
parameters are set, such as sensor type, measuring range,
lter activation, CJC, sensor failure action, error corrections etc.
MIN
IPAQ Soft, is used
INOR Process AB, PO Box 9125, SE-200 39 Malmö, Sweden, Phone: +46(040)31 25 60, Fax: +46(040)31 25 70, E-mail: info@inor.se
INOR Transmitter GmbH, Rodenbacher Chaussee 6, DE-63457 Hanau-Wolfgang, Germany, Phone: +49(0)6181-582940, Fax: +49(0)6181-582944
INOR Transmitter Inc, 7 Dearborn Road, Peabody, MA 01960, USA, Phone: +1(978) 826-6900 / (262) 670-9050, Fax: +1(978) 535-3882 / (262) 670-9001
www.inor.com
Specications
18.5/0.72
44.5/1.75
Input RTD
Pt100 (IEC 60751, α = 0.00385) 3-, 4-wire connection -200 to + 1000 °C / -328 to + 1832 °F Pt 100 (JIS C 1604, α = 0.003916) 3-, 4-wire connection -200 to + 1000 °C / -328 to + 1832 °F Pt 100 (US, α = 0.003902) 3-, 4-wire connection -200 to + 1000 °C / -328 to + 1832 °F Pt1000 (IEC 60751, α = 0.00385) 3-, 4-wire connection -200 to + 200 °C / -328 to + 392 °F Ni100 (DIN 43760) 3-, 4-wire connection -60 to + 250 °C / -76 to + 482 °F Ni1000 (DIN 43760) 3-, 4-wire connection -100 to + 150 °C / -148 to + 302 °F PtX (IEC 60751, α = 0.00385) 3-, 4-wire connection Any Pt function between Pt10- Pt1000 Ni120 (Edison No.7) 3-, 4-wire connection -70 to + 300 °C / -94 to + 572 °F Cu10 (Edison No.15) 3-, 4-wire connection -200 to + 260 °C / -328 to + 500 °F Sensor current ~ 0.4 mA Maximum sensor wire resistance 25 /wire
Input Thermocouples
Range Type: B, C, E, J, K, L, N, R, S, T, U Acc. to T/C standards Maximum sensor wire resistance 500 (total loop)
Monitoring
Sensor failure monitoring Upscale or downscale action
Adjustments
Zero adjustment All inputs Any value within range limits Minimum spans Pt and Ni input 10 °C / 18 °F Cu10 100 °C / 180 °F T/C 2 mV
Output
Analog 4-20 mA, temperature linear Resolution 5 µA Minimum output signal Measurement/Failure 3.8 mA / 3.5 mA Maximum output signal Measurement/Failure 20.5 mA / 21.6 mA Permissible load, see load diagram 725 @ 24 VDC
Temperature
Ambient, storage and operation -40 to + 85 °C / -40 to + 185 °F
General data
Selectable dampening time ~ 2 s Update time ~ 1.5 s Isolation In - Out Non-isolated Humidity 0 to 100 %RH Vibration Acc. to IEC 60068-2-6, test Fc, 60-500 Hz, 10 g
Power supply,polarity protected
Supply voltage 8 to 32 VDC Permissible ripple 4 V p-p @ 50/60 Hz
Accuracy
Linearity RTD ±0.1 % T/C ±0.2 % Calibration RTD Max. of ±0.2 °C/ ±0.4 °F or ±0.1 % T/C Max. of ±20 µV or ±0.1 % Cold Junction Compensation (CJC) T/C ±0.5 °C / ±0.9 °F
Temperature inuence 3) All inputs Max. of ±0.25 °C/25 °C or ±0.25%/25 °C
Max. of ±0.5 °F/50 °F or ±0.28%/50 °F
Temperature inuence CJC 3) T/C ±0.5 °C/25 °C / ±1.0 °F/50 °F RFI inuence, 0.15 to 1000 MHz, 10 V or V/m ±0.5%
Long-term stability ±0.2 % 1) /year
Housing
Material, Flammability (UL) PC/ABS + PA, V0 Mounting DIN B-head or larger, DIN rail (with mounting kit) Connection Single/stranded wires Max. 1.5 mm2, AWG 16 Weight 32 g Protection, housing / terminals IP 65 / IP 00
1)
Of input span
3)
Reference temperature 20 °C / 68 °F
Input connections
2)
If zero-deection > 100% of input span: add 0.125% of input span/25 °C or 0.14% of input span/50 °F per 100% zero-deection
Output load diagram Dimensions
1)
1)
1)
(typical)
1)
1)
1) 2)
1) 2)
RTD
3-wire connection
RTD
4-wire connection
Output connections
Thermocouple
I
All information subject to change without notice.
R
OUT
LOAD
R
() =(U-8.0)/0.022
LOAD
PC communication port
mm/inches
Supply voltage U (V DC)
Ordering information
MIN
IPAQ-HLP 70MQHLP002
PC Conguration Kit (USB conn.) 70CFGUS001 Conguration 70CAL00001
Head mounting kit 70ADA00017 Rail mounting kit 70ADA00013
86DMQHLP01 2007-09
Loading...