INOR MESO-H Specifications

14
14
MESO-H
SPECIALISTS IN INDUSTRIAL TEMPERATURE MEASUREMENT
Universal HART-compatible
Input connections
RTD
4-wire connection
2-wire Transmitters
MESO-H/-HX are smart and universal 2-wire in-head transmitters for tem­perature and other measurement applications. MESO-H/-HX are fully HART­compatible, with communication through the HART protocol.
• Utilizes HART Protocol for remote conguration and monitoring
• Communicates with HART Communicator or PC via modem
• Fully universal, linearized and isolated
• Accepts RTD, T/C, mV and Ω
• Sensor error correction
• Easy wiring, large center hole
• 50 point linearization – any sensor can be matched
• Consistent sensor break function
• Full access to all features while in operation
• Low sensor isolation detection
• MEPRO, easy-to-use Windows conguration software
• Integrated in Emerson AMS and Siemens PDM systems
RTD
3-wire connection
Pt100
Diff temperature T1 > T2
Potentiometer
3-wire connection
Potentiometer
4-wire connection
Voltage
mV
Thermocouple
Output connections
A-B and B-C are possible
I
OUT
R
connections for HART mo­dem or Communicator
LOAD
Specications:
Input RTD and Resistance 3-,4-wire connection
1)
Pt100
and D1002) -200 to +1000 °C / -328 to +1832 °F Pt10001) -200 to +200 °C / -328 to +392 °F PtX 10 X 10001) Upper range depending on X value
3)
Ni100 Ni10003) -60 to +150 °C / -76 to +302 °F Potentiometer / resistance 0 to 2000
Input Thermocouples B, C, E, J, K, L, N, R, S, T, U Input Voltage -10 to +500 mV Sensor failure / Low isolation User denable output Adjustments - Zero Any value within range limits Adjustments - Minimum spans
Pt100, Pt1000, Ni100, Ni1000 10 °C /18 °F Potentiometer 10 T/C, mV 2 mV
Output 4-20 / 20-4 mA Operating temperature -40 to +85 °C / -40 to +185 °F Galvanic isolation 1500 VAC, 1 min Power supply MESO-H 10 to 42 VDC
MESO-HX 12 to 30 VDC
Intrinsic safety
MESO-HX ATEX: II 1 G EEx ia IIC T4-T6 MESO-HX FM: IS Class I-III, DIV 1, GP A-D, G MESO-HX CSA: Class I, Groups A-D; Class II, Group G; Class III
Typical accuracy ±0.1% of temperature span Connection head DIN B or larger
1)
IEC 60751, α=0.00385 2)Pt100 acc. to JIS 1604, α=0.003916
-60 to +250 °C / -76 to +482 °F
3)
DIN 43760
Output load diagram
R
()
LOAD
Supply voltage U (V DC)
R
=(U-10)/0.023 (MESO-H)
LOAD
R
=(U-12)/0.023 (MESO-HX)
LOAD
Dimensions
mm/inches
Ordering information
MESO-H 70MEH00001 MESO-HX (ATEX) 70MEHX0001 MESO-HX (FM, CSA) 70MEHX1001 HART PC modem RS232 70MEM00001 HART PC modem USB 70MEM00003 Software CD 70CDSOFT01 Conguration 70CAL00001
Loading...