INOR IsoPAQ-11L, IsoPAQ-12L Operating Manual

USER INSTRUCTIONS English
Loop Powered Isolator
www.inor.com
Read these instructions before using the product and retain for future information.
The isolator should only be installed and put into
The isolator should only be installed and put into operation by qualified staff. The staff must have
operation by qualified staff. The staff must have studied the warnings in these operating instructions
studied the warnings in these operating instructions thoroughly.
thoroughly.
The isolator may not be put into operation if the
The isolator may not be put into operation if the housing is open.
housing is open.
In applications with high operating voltages
In applications with high operating voltages sufficient distance and isolation as well as shock
sufficient distance and isolation as well as shock protection must be ensured.
protection must be ensured.
Safe and trouble-free operation of this device can
Safe and trouble-free operation of this device can only be guaranteed if transport, storage and
only be guaranteed if transport, storage and installation are carried out correctly and operation
installation are carried out correctly and operation an maintenance are carried out with care.
an maintenance are carried out with care.
Appropriate safety measures against electrostatic
Appropriate safety measures against electrostatic discharge (ESD) should be taken during connection and
discharge (ESD) should be taken during connection and assembly on the isolator.
assembly on the isolator.
2. Short description 2. Short description
The loop powered isolator is used for electrical isolation and
The loop powered isolator is used for electrical isolation and processing of 0(4) - 20 mA standard signals.
processing of 0(4) - 20 mA standard signals.
The galvanic isolation guarantees reliable decoupling of the sensor
The galvanic isolation guarantees reliable decoupling of the sensor circuit from the processing circuit and prevents linked measurement
circuit from the processing circuit and prevents linked measurement circuits from influencing each other.
circuits from influencing each other.
3. Functioning 3. Functioning
The input signal is modulated and then electrically decoupled using
The input signal is modulated and then electrically decoupled using a transformer. The isolated signal is then made available at the
a transformer. The isolated signal is then made available at the output, demodulated and filtered.
output, demodulated and filtered.
When using loop-powered Isolators, ensure that the current-driving
When using loop-powered Isolators, ensure that the current-driving voltage of the power source U
voltage of the power source U current of 20 mA over the isolator with voltage drop of U
current of 20 mA over the isolator with voltage drop of U and the load Rl
and the load Rl
U
U
UIN = 2 V + 20 mA x R
UIN = 2 V + 20 mA x R
S
S
Optional use:
U
= US - 2 V - 20 mA x R
T
4. Equipment
A screwdriver with a width of 2.5 mm is required connect the wires to the screw clamp terminals.
5. Mounting, electrical connection
The isolation transmitter is mounted on standard 35 mm DIN rail.
Terminal assignments
Channel 1 Channel 2
1 Input + 3 Input + 2 Input - 4 Input -
5 Output + 7 Output + 6 Output - 8 Output -
6. Order information
Product Input / Output Part No.
IsoPAQ-11L 1-channel, 0(4) - 20 mA 70ISL11001 IsoPAQ-12L 2-channel, 0(4) - 20 mA 70ISL12001
.
.
oad
oad
is sufficient for driving the maximum
is sufficient for driving the maximum
S
S
load
load
drop
drop
= 2 V
= 2 V
7. Technical Data

Input

Input signal 0(4) - 20 mA / max. 30 V Operating current Voltage drop Overload

Output

Output signal 0(4) - 20 mA / max. 28 V Response time
(10 to 90 % of end value) Ripple < 20 mV

General data

Transmission error Load error Temperature coefficient1) Test voltage 1.5 kV, 50 Hz Between all circuits Ambient temperature
EMC2) EN 61326 -1 Construction 12,5 mm (0.5’’) housing, protection type: IP 20 Connection Weight Approx. 100 g
1) Average T C in specified operating temperature rang e
2) Minor deviations possible during int erference
8. Block diagram
< 20 µA < 2 V 100 mA, 30 V
2 ms @ 250 load / 6 ms 750 load
rms
± 0.1 % of end value ± 0.03 % of measured value / 100 load ± 0.0015 %/K of measured value / 100 loa d
Operation Transport and storage
2.5 mm2, AWG 14
- 20 °C to + 70 °C (-4 to +158 °F)
- 35 °C to + 85 °C (-31 to +185 °F)
9. Dimensions
LIMITED WARRANTY
INOR Process AB, or any other affiliated company within the Inor Group (hereinafter jointly referred to as ”Inor”), hereby warrants that the Product will be free from defects in materials or workmanship for a period of five (5) years from the date of delivery (”Limited Warranty”). This Limited Warranty is limited to repair or replacement at Inor’s option and is effective only for the first end-user of the Product. Upon receipt of a warranty claim, Inor shall respond within a reasonable time period as to its decision concerning:
1. Whether Inor acknowledges its responsibility for any asserted defect in materials or workmanship; and, if so,
2. the appropriate cause of action to be taken (i.e. whether a defective product should be replaced or repaired by Inor).
This Limited Warranty applies only if the Product:
1. is installed according to the instructions furnished by Inor;
2. is connected to a proper power supply;
3. is not misused or abused; and
4. there is no evidence of tampering, mishandling, neglect, accidental damage, modification or repair without the approval of Inor or damage done to the Product by anyone other than Inor.
This Limited Warranty is provided by Inor and contains the only express warranty provided.
INOR SPECIFICALLY DISCLAIMS ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GU ARANTEE OR REPRESENTATION AS TO SUITABILITY FOR ANY PARTICULAR PURPOSE, PERFORMANCE, QUALITY AND ABSENCE OF ANY HIDDEN DEFECTS, AND ANY REMEDY FOR BREACH OF CONTRACT, WHICH BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS PROVIDED HEREIN, INOR FURTHER DISCLAIMS ANY RESPONSIBILITY FOR LOSSES, EXPENSES, INCONVENIENCES, SPECIAL, DIRECT , SECONDARY OR CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THE PRODUCT.
Products that are covered by the Limited Warranty will either be repaired or replaced at the option of Inor. Customer pays freight to Inor, and Inor will pay the return freight by post or other “normal” way of transport. If any other type of return freight is requested, customer pays the whole return cost.
INOR Process AB