PAQ series transmitters are fully programmable two-wire
I
transmitters for temperature and other measurement
applications; IPAQ transmitters are available in DIN rail or in-head
mounting configuration. The IPAQ-HX/LX are Intrinsically Safe,
FM approved versions for use in hazardous areas. The combination
of competitive pricing, functionality, and simple configuration
has made the IPAQ series a leading transmitter for industrial
measurements.
The IPAQ series has been designed for applications with stringent
industrial demands on accuracy. To reach these demands, these
transmitters use quality components and precision calibration equipment
which reduce linearity and calibration errors. They also offer high longterm stability through an internal “self calibration”, continuous adjustment
of important parameters after being compared with accurate built-in
references, which contributes to a stability of ±0.1% per year.
The Smart Sense feature continuously monitors the isolation resistance
of thermocouples and three-wire connected RTDs, as well as the cabling
between sensor and transmitter. The transmitter will react by forcing the
output to a user defined level if the isolation is too low. IPAQ transmitters
also
monitor sensor break and force the output signal to a user defined
level, when any sensor lead is broken or disconnected. The dampening
function can be used to dampen undesired instabilities on the input
signal.
Simplified loop check-up—the transmitter works as an accurate current generator with user defined action
On-screen indications and line recording—valuable tools for
temporary measurements
Improved quality with data storage—vital information such
as TAG-No., maintenance record etc. can be stored in the
nonvolatile memory
IPRO-X SOFTWARE
PRO-X user friendly software lets you prepare
I
configurations, save them as files, and transfer
them to any IPAQ transmitter. Besides measurement
configuring, IPRO-X software can also be used
to monitor the sensor status and input/ output
signals with real time on-screen presentations.
The updating time is user selectable. It also allows
for field calibration in one or two point modes.
For this function, the transmitter is subjected to a
calibration source (e.g. a process calibrator); the
transmitter outputs are entered and IPRO software
will automatically correct the transmitter.
IPRO software is compatible with Windows™ 3.1,
Windows™ 3.11, Windows™ 95 and Windows™ NT
Workstation 4.0.
Precision accuracy—linearity 0.05% for RTD. Reduced temperature influence. Each transmitter is individually temperature compensated. Long-term stability is 0.05% per year
Fast response—update time down to 170ms (with a measuring frequency of approximately six per second)
Enhanced total system accuracy—sensor error correction
(for known sensor errors) and system error correction
(against known temperatures)
Smart filter—short response time combined with high noise
immunity
Input/Output isolation of up to 3750 VAC—excellent filtering
of voltage spikes and elimination of ground loops
High load capacity—only 7.5V voltage drop over the transmitter allows for high loads
Designed for harsh conditions—operation temperature up to
85˚C/185˚F (105˚C/221˚F available), with excellent EMC performance and a durable, shockproof design
Warranty—five-year warranty against manufacturer’s defects
Page 3
IPAQ SPECIFICATIONS
INPUT STYLES RANGES
RTD’s and RESISTANCE
Pt100 3-, 4-wire connection -200 to +1000°C/-328 to +1832°F
Pt1000 3-, 4-wire connection -200 to +200°C/-328 to +392°F
PtX 10 ≤ X ≤ 1000 ) 3-, 4-wire connection Upper range depending on X-value
Ni100 3-, 4-wire connection -60 to +250°C/-76 to +482°F
Ni1000 3-, 4-wire connection -60 to +150°C/-76 to +302°F
D100 3-, 4-wire connection -200 to +1000°C/-328 to +1832°F
Potentiometer/resistance 0 to 2000Ω
THERMOCOUPLES AND VOLTAGE
T/C Type AE, B, E, J, K, L, N, R, S, T, U. Ranges according to users manual
Voltage input mV -10 to +500mV
Input impedance >10MΩ
Max sensor wire resistance 500Ω (total loop)
ADJUSTMENTS
Zero adjustment All inputs Any value within range limits
Min. spans Pt100, Pt1000, Ni100, Ni1000 10°C/18°F
Potentiometer 10Ω
T/C, mV 2mV
TYPICAL ACCURACY
IPAQ plus models ±0.05% of temperature span
IPAQ-H/HX/L/LX ±0.1% of temperature span
OUTPUT
Current User definable output 4 to 20/20 to 4mA
Linearity Temperature linear
Current Limitation 21.6mA
POWER SUPPLY
IPAQ-HX/LX 8.0 to 30V DC 2-wire
ISOLATION
IPAQ plus models 3750 VAC
IPAQ-H/L 7.5 to 36V DC 2-wire
IPAQ-H/HX/L/LX 1500 VAC
MONITORING
Sensor break monitoring User definable output 3.5 to 21.6mA
SmartSense User definable output 3.5 to 21.6mA (IPAQ-H/HX only)
INTRINSIC SAFETY
OPERATING TEMPERATURE
IPAQ-L/LX -20 to +70°C/-4 to +158°F
IPAQ-HX/LX & plus models FM: Class 1, Div 1, GR. A-D
IPAQ-H/HX -40 to +85°C/-40 to +185°F