1. General Specifications
NO. Item Specification Unit
1 Display resolution (pixel) 1366(H) X 768(V), HD resolution
2 Active area 309.40(H) X 173.95(V) mm
3 Screen size 14.0 inches diagonal Inches
4 Pixel pitch 0.2265(H) X 0.2265(V) mm
5 Color configuration Stripe
SPEC NO.
PAGE
BT140GW01 V.A
4/28
6 Overall dimension
7 Weight
8 Surface treatment Glare, 3H
9 Input color signal 6 bit LVDS
10 Display colors 262K (6 bit)
11 Optimum viewing direction 6 o’clock
12 Backlight W-LED
13 RoHS RoHS compliance
www.jxlcd.com
www.jxlcd.com
324(W) X 192.5(H) X 5.2(D) (max)
350Max.
mm
Grams
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 5
2. Electrical Specifications
2-1 Pin Assignment
a. Panel connector
Connector Part No:
User’s connector Part No: 20453-040T-12(I-PEX) or equivalent
Pin No Symbol Description Remark
1 NC No connection (Reserve)
2 VCC Power Supply (+3.3V)
3 VCC Power Supply (+3.3V)
4 V
5
6 Clk
7 DATA
8 Rxin0- Differential Data Input
9 Rxin0+ Differential Data Input
10 GND Ground
11 Rxin1- Differential Data Input
12 Rxin1+ Differential Data Input
13 GND Ground
14 Rxin2- Differential Data Input
15 Rxin2+ Differential Data Input
16 GND Ground
17 CLK- Differential Clock Input
www.jxlcd.com
18 CLK+ Differential Clock Input
19 NC No connection (Reserve)
20 NC No connection (Reserve)
21 NC No connection (Reserve)
22 NC No connection (Reserve)
23 NC No connection (Reserve)
24 NC No connection (Reserve)
25 NC No connection (Reserve)
26 NC No connection (Reserve)
27 NC No connection (Reserve)
28 NC No connection (Reserve)
29 NC No connection (Reserve)
30 NC No connection (Reserve)
31 LED_GND LED Ground
32 LED_GND LED Ground
33 LED_GND LED Ground
34 NC No connection (Reserve)
35 LED_PWM PWM dimming signal input
36 LED_EN LED enable pin (3.3V)
37 NC No connection (Reserve)
38 V_LED LED power supply 6.0V~21V
39 V_LED LED power supply 6.0V~21V
40 V_LED LED power supply 6.0V~21V
www.jxlcd.com
GS13401-1110S-7H (Foxconn )
DDC Power +3.3V
EDID
NC No connection (Reserve)
DDC Clock
EDID
DDC Data
EDID
SPEC NO.
PAGE
BT140GW01 V.A
5/28
R0~R5,G0
G1~G5,B0,B1
B2~B5,DE,Hsync,Vsync
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 6
b. General Block Diagram (Rear-side)
LED
Drive
FPC
GS13401-1110S-7H
DC/DC
VR
www.jxlcd.com
www.jxlcd.com
T-C
Connector plug in direction
GS13401-1110S-7H (Foxconn )
Pin1
SPEC NO.
PAGE
BT140GW01 V.A
6/28
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 7
V
2-2. Absolute Maximum Ratings
SPEC NO.
PAGE
BT140GW01 V.A
7/28
Parameter Symbol
Min.Max.
Power input voltage V
Signal input voltage V
Operating temperature T
Storage temperature T
Re-screw - 5 Times
Assured torque at side mount - 2 kgf.cm
Note 1: The relative humidity must not exceed 90% non-condensing at temperatures of 40°C or less.
At temperatures greater than 40°C, the wet bulb temperature must not exceed 39°C.
Note 2: The unit should not be exposed to corrosive chemicals.
Relative Humidity (%RH)
-30-20-10010203040506070
www.jxlcd.com
100
90
www.jxlcd.com
80
70
60
50
40
30
20
10
Operation Range
Storage Range
0
Temperature (°C)
- 0.3 4.0 V At 25°C
CC
- 0.3 4.0 V At 25°C
IN
0 50 °C Note 1
OP
- 20 60 °C Note 2
ST
alues
Unit
Remark
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 8
2-3. Electrical Characteristics
a. Typical operating conditions
Item SymbolMin. Typ. Max. Unit Remark
SPEC NO.
PAGE
BT140GW01 V.A
8/28
Power input voltage
Permissive power input ripple
Power input current
Power consumption
Differential input high
threshold voltage
Differential input low
LVDS
interface
Note 1: The specified input current and power consumption are under the V
Note 2: LVDS waveform diagram
Rxin+/CLK+
Rxin-/CLK-
threshold voltage
Common input
voltage
Terminating resistor
Rush current
LED rush current
www.jxlcd.com
www.jxlcd.com
f
=60Hz (frame frequency) condition whereas mosaic pattern is displayed.
V
3 3.3 3.6 V
V
CC
V
- - 0.1 V
RF
- 300 330 mA Note 1
I
CC
P
- - 1 Watts Note 1
C
V
- - +100 mV
LVT H
V
-100 - - mV
LVT L
V
1.0 1.2 1.4 V Note 2
LVC
R
90 100 110 ohm
T
I
- - 1.5 A Note 3
Rush
I
LED-Rush
- - 3.0 A Note 4
V
LVC
V
LVC
=3.3 V, 25°C,
cc
=1.2V,
Note 2
=1.2V,
Note 2
V
LVT H
V
LVT L
V
LVC
GND
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 9
SPEC NO.
PAGE
BT140GW01 V.A
9/28
Note 3: Test condition
(1) Pattern: Black pattern
(2) V
= 3.3 V, V
CC
rising time = 470 μs ± 10%
CC
Control signal
(High to low)
90%
10%
V
CC
Ton=470µs±10%
(3) Test circuit
3.3 V
R1
47K
R2
www.jxlcd.com
www.jxlcd.com
12V
C3
1uF
1K
R3
47K
M1
2SK1059
C2
10000pF
M2
2SK1399
FUSE
C1
1uF
VCC ( LCD input)
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 10
_
SPEC NO.
PAGE
BT140GW01 V.A
10/28
Note 4: Test condition
(1) Pattern: LED duty 100%
(2) V_LED= 12.0V, V_LED rising time = 470
μs ± 10%
Control signal
(High to low)
90%
10%
V
LED
Ton=470µs±10%
(3) Test circuit
12 V
R1
47K
www.jxlcd.com
www.jxlcd.com
21V
C3
1uF
R2
1K
R3
47K
M1
2SK1059
C2
10000pF
M2
2SK1399
FUSE
C1
1uF
V_LED
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 11
b. Power sequence
SPEC NO.
PAGE
BT140GW01 V.A
11/28
www.jxlcd.com
www.jxlcd.com
Power sequence timing table
Parameter
t
≧0.5 -- ≦10 ms
1
t
≧0 -- ≦50 ms
2
t
≧0 -- -- ms
3
t
≧150 -- -- ms
4
t
≧200 --- -- ms
5
t
≧0 -- -- ms
6
t
≧0 -- ≦10 ms
7
t
≧0.5 -- ≦10 ms
A
t
>0 -- -- ms
B
t
≧0 -- -- ms
C
t
≧0 -- -- ms
D
t
≧0 -- -- ms
E
t
≧0 -- -- ms
F
Value
Min. Typ. Max.
Units
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 12
c. Display color vs. input data signals
Signal Name Description Remark
R5 Red Data 5 (MSB)
R4 Red Data 4
R3 Red Data 3
R2 Red Data 2
R1 Red Data 1
R0 Red Data 0 (LSB)
Red-pixel Data
G5 Green Data 5 (MSB)
G4 Green Data 4
G3 Green Data 3
G2 Green Data 2
Red-pixel data. Each red pixel's brightness data
consists of these 6 bits pixel data.
Green-pixel data. Each green pixel's brightness
data consists of these 6 bits pixel data.
SPEC NO.
PAGE
BT140GW01 V.A
12/28
G1 Green Data 1
G0 Green Data 0 (LSB)
Green-pixel Data
B5 Blue Data 5 (MSB)
B4 Blue Data 4
B3 Blue Data 3
B2 Blue Data 2
B1 Blue Data 1
www.jxlcd.com
www.jxlcd.com
B0 Blue Data 0 (LSB)
Blue-pixel Data
Signal for 1 DCLK cycle (t
Blue-pixel data. Each blue pixel's brightness data
consists of these 6 bits pixel data.
)
CLK
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 14
f. Backlight driving conditions
Parameter Symbol Min. Typ. Max. Unit Remark
SPEC NO.
PAGE
BT140GW01 V.A
14/28
LED forward voltage V
LED forward current
EN Control Level
PWM Control Level
Power consumption
Input PWM frequency F
Duty ratio - 5 100 % Note 1
LED life time - 15,000 Hr T = 25°C , Note 2
Note 1: PWM duty cycle linearity guarantees 10~100%.
Note 2: LED life time definition is brightness decrease to 50% of initial or abnormal lighting.
Note 3: Total LED Power consumption with LED Driver.
g. Module function block
www.jxlcd.com
www.jxlcd.com
LED driver
controller
3 3.2 3.4 V
F
IF 20 mA
BL on 2.3 3.6 V
BL off 0 0.8 V
BL on 2.3 3.6 V
BL off 0 0.8 V
PBL 2.8 3.2 W
190 2000 Hz T = 25°C
PWM
LED Light-bar
TFT-LCD
Source driver
Timing
Step-up regulator
& reference voltage
generator
LVDS connector
r
Gate driver
EDID
EEPROM
T = 25°C
T = 25°C
T = 25°C
T = 25°C
T = 25°C
T = 25°C
T = 25°C, Note3
LVDS DATA BUS mini-LVDS & CONTROL BUS POWER I2C BUS
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 15
SPEC NO.
PAGE
BT140GW01 V.A
15/28
3. Optical specifications
Ambient temperature = 25°C
Item Symbol Condition
Specification
Min. Typ. Max.
Unit Remark
Response time
Contrast ratio CR
Viewing angle
Brightness
(5 points average)
Color chromaticity (CIE)
www.jxlcd.com
www.jxlcd.com
Tr+Tf θ= 0°
θ= 0°
Top
Bottom
Left
Right
190 220 nit Note 2,5
Y
L
Wx
Wy
Rx
Ry
Gx
Gy
Bx
CR≧10
CR≧10
CR≧10
CR≧10
θ= 0°
500 600 Note 2,4
15
30
40
40
-0.03
8 16 ms Note 3
deg Note 2,4,6
0.313
0.329
0.58
0.353
0.32
0.577
0.165
+0.03
Note 2
B
y
Color Gamut NTSC CIE1931 45 % -
δ
0.8 Note 2,7
W(5)
White uniformity
δ
0.65
W(13)
Cross talk Ct 2% Note 8
Note 1: To be measured in dark room.
Note 2: To be measured with a viewing cone of 2°by Topcon luminance meter BM-5A.
Note 3: Definition of response time:
The output signals of BM-7 are measured when the input signals are changed from “Black” to
“White” (falling time) and from “White” to “Black” (rising time), respectively. The response time
interval is between 10% and 90% of amplitudes. Refer to figure as below.
0.14
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 16
(
Avg
)
r
SPEC NO.
PAGE
BT140GW01 V.A
16/28
100%
S
i
90%
g
n
a
l
(
R
e
l
a
t
i
v
e
v
a
l
u
10%
e
)
0%
Note 4: Definition of contrast ratio:
Contrast ratio is calculated with the following formula:
Note 5: Driving current for LED should be 20 mA.
Note 6: Definition of viewing angle
Contrast ratio
Luminance is measured at the following thirteen points (1~13):
Y
= (Y5+ Y10+Y11+Y12 +Y13) / 5
L
www.jxlcd.com
www.jxlcd.com
Tr
of 5pts
=
"Black"
L white (Avg of 5pts.)
L
Black (Avg of 5pts.)
"White""White"
Tf
Note 7: Definition white uniformity
Luminance is measured at the following thirteen points (1~13):
δ
Minimum brightness of thirteen points
W(13) =
δ
W(5) =
Maximum brightness of thi
Minimum brightness of five points
Maximum brightness of five points
teen points
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 17
13 point measuring locations refer to the point 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 and 13.
5 point measuring locations refer to the point 5, 10, 11, 12 and 13.
SPEC NO.
PAGE
BT140GW01 V.A
17/28
Note 8:
1/2
www.jxlcd.com
www.jxlcd.com
32 gray level 32 gray level
Unit: percentage of dimension of display area
l L
l L
l / LA x 100%= 2% max., LA and L
A-LA’
l / LB x 100%= 2% max., LB’ and LB’ are brightness at location B and B’
B-LB’
A
1/6
B
1/6
1/2
2/31/3
are brightness at location A and A’
A’
1/2
A’
0 gray level
1/6
1/6
1/3
1/2
B’
2/3
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 18
4. Reliability test items
Test Item Test Condition Judgment Remark
SPEC NO.
PAGE
BT140GW01 V.A
18/28
High temperature storage
Low temperature storage
High temperature & high
humidity operation
High temperature operation
Low temperature operation
Thermal Shock
(Non-operation)
Electrostatic discharge (ESD)
Vibration
(Non-operation)
www.jxlcd.com
Mechanical shock
(Non-operation)
www.jxlcd.com
60°C, 240 hours
-20°C, 240 hours
40°C, 90% RH, 240 hours
(No condensation)
50°C, 240 hours
0°C, 240 hours
-25°C / 30 mins ~ -65°C / 30 mins
100 cycles
150 pF, 330Ω,
Contact: ±8kV, Air: ±15kV
1.5G, 10 to 500 Hz random; 0.5hr in each
perpendicular axes ( X, Y, Z ).
220G/2ms, Half sine wave, ±X, ±Y, ±Z one
time for each direction
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1
Note 1 Note 2
Note 1 Note 2
Note 1: Pass: Normal display image with no obvious non-uniformity and no line defect.
Fail: No display image, obvious non-uniformity, or line defects.
Partial transformation of the module parts should be ignored.
Note 2: Evaluation should be tested after storage at room temperature for more than one hour.
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMI SSION FROM Chimei-Innolux
Page 19
5. Safety
5-1. Sharp edge requirements
There will be no sharp edges or corners on the display assembly that could cause injury.
5-2. Materials
a. Toxicity
There will be no carcinogenic materials used anywhere in the display module. If toxic materials
are used, they will be reviewed and approved by the responsible InnoLux Toxicologist.
b. Flammability
All components including electrical components that do not meet the flammability grade UL94-V0
in the module will complete the flammability rating exception approval process. The printed circuit
board will be made from material rated 94-V0 or better. The actual UL flammability rating will be
printed on the printed circuit board.
SPEC NO.
PAGE
BT140GW01 V.A
19/28
c. Capacitors
If any polarized capacitors are used in the display assembly, provisions will be made to keep
them from being inserted backwards.
6. Display quality
The display quality of the color TFT-LCD module should be in compliance with the InnoLux
incoming inspection standard.
www.jxlcd.com
www.jxlcd.com
7. Handling precaution
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The
dust and oil may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and
backlight will be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and
operating.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is
very soft and easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture
may damage LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD
module within the specified storage conditions.
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR