f. Backlight driving conditions
Parameter SymbolMin. Typ. Max. Unit Remark
SPEC NO.
PAGE
BT101IW03 V.1
12/ 27
LED Forward Voltage V
LED Forward Current
LED Power consumption
Output PWM frequency F
Duty ratio - 5 100 % Note 1, 2
LED Life Time (LED only) - 15,000Hr T = 25°C , Note 3
Note 1: The BL power consumption @100 nits with full white pattern under the V
C, f
=60Hz (frame frequency) condition
V
Note 2: PWM duty cycle linearity guarantees 20~100%.
Note 3: LED life time definition is brightness decrease to 50% of initial or abnormal lighting.
g. Module function block
www.jxlcd.com
www.jxlcd.com
LED driver
Timing
controller
3 3.2 3.4 V
F
IF 20 mA
P
2.1 (2.3) W
LED
200 1000 2000 Hz T = 25°C, Note 1, 2
PWM
LED Light-bar
TFT-LCD
Source driver
Step-up regulator
& reference voltage
generator
EEPROM
LVDS connector
T = 25°C, Note 1, 2
rms
T = 25°C, Note 1, 2
rms
T = 25°C, Note 1, 2
=3.3 V, 25 °
cc
Gate driver
EDID
LVDS DATA BUS mini-LVDS & CONTROL BUS POWER I2C BUS
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
h. LED circuit block
SPEC NO.
PAGE
BT101IW03 V.1
13/ 27
LED Driving
Circuit
LED_P
3 parallels
& 9 series
www.jxlcd.com
www.jxlcd.com
FB1
FB2
FB3
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
3. Optical specifications
SPEC NO.
PAGE
BT101IW03 V.1
14/ 27
Item Symbol Condition
Response time
Contrast ratio CR
Viewing angle
Brightness
(5 points average)
Color chromaticity (CIE)
Specification
Min. Typ. Max.
Tr+Tf θ= 0∘
θ= 0∘
Top 15
Bottom 30
CR≧10
Left 40
Right
Y
170 200 nit Note 2,5
L
Wx
Wy
Rx
Ry
Gx
θ= 0∘
400 500 Note 2,4
40
-0.03
8 16 ms Note 3
0.313
0.329
0.575
0.348
+0.03
0.336
Unit Remark
deg Note 2,4,6
Note 2
Gy
www.jxlcd.com
www.jxlcd.com
Color Gamut NTSC CIE1931 40 45 % -
White uniformity δ
Cross talk Ct 2% Note 8
Note 1: To be measured in dark room.
Note 2: To be measured with a viewing cone of 2°by Topcon luminance meter BM-5A.
Note 3: Definition of response time:
The output signals of BM-7 are measured when the input signals are changed from “Black” to
“White” (falling time) and from “White” to “Black” (rising time), respectively. The response time
interval is between 10% and 90% of amplitudes. Refer to figure as below.
Bx
B
y
(1.55) Note 2,7
W(13)
0.574
0.154
0.105
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
(
Avg
)
SPEC NO.
PAGE
BT101IW03 V.1
15/ 27
100%
S
i
90%
g
n
a
l
(
R
e
l
a
t
i
v
e
v
a
l
u
10%
e
)
0%
Note 4: Definition of contrast ratio:
Contrast ratio is calculated with the following formula:
Note 5: Driving current for LED should be 20 mA.
Note 6: Definition of viewing angle
Contrast ratio
Luminance are measured at the following thirteen points (1~13):
= (Y5+Y10+Y11+Y12+Y13) / 5
Y
L
Tr
of 5pts
L white (Avg of 5pts.)
=
L
"Black"
Black (Avg of 5pts.)
"White""White"
Tf
www.jxlcd.com
www.jxlcd.com
Note 7: Definition white uniformity:
Luminance is measured at the following thirteen points (1~13):
δ
W(13) =
δ
W(5) =
Maximum Brightness of thirteen points
Minimum Brightness of thirteen points
Maximum Brightness of five points
Minimum Brightness of five points
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
13 point measuring locations refer to the point 1,~13.
5 point measuring locations refer to the point 5,10~13.
L and W are active area dimensions. Active area center refer to attached drawing
SPEC NO.
PAGE
BT101IW03 V.1
16/ 27
Note 8:
32 gray level 32 gray level
Unit: percentage of dimension of display area
l L
l L
1/2
A
www.jxlcd.com
www.jxlcd.com
l / LA x 100%= 2% max., LA and L
A-LA’
l / LB x 100%= 2% max., LB’ and LB’ are brightness at location B and B’
B-LB’
B
1/6
1/6
1/2
2/31/3
are brightness at location A and A’
A’
1/2
A’
0 gray level
1/6
1/6
1/3
1/2
B’
2/3
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
4. Reliability test items
Test Item Test Condition Judgment Remark
SPEC NO.
PAGE
BT101IW03 V.1
17/ 27
High temperature storage
Low temperature storage
High temperature & high
humidity operation
High temperature operation 50°C, 240 hours Note 1 Note 2
Low temperature operation 0°C, 240 hours Note 1 Note 2
Thermal Shock
(Non-operation)
Electrostatic discharge (ESD)
Vibration
(Non-operation)
Mechanical shock
(Non-operation)
Note 1: Pass: Normal display image with no obvious non-uniformity and no line defect.
Fail: No display image, obvious non-uniformity, or line defects.
Note 2: Evaluation should be tested after storage at room temperature more than one hour.
www.jxlcd.com
www.jxlcd.com
Partial transformation of the module parts should be ignored.
60°C, 240 hours
-20°C, 240 hours
40°C, 90% RH, 240 hours
(No condensation)
-25°C / 30 mins ~ 65°C / 30 mins
100 cycles
150 pF, 330Ω,
Contact: ±8kV, Air: ±15kV
1.5Grms, (PSD: 0.0046^G/Hz) 10 to 500
Hz random; 0.5hr for each perpendicular
axes ( X, Y, Z ).
220G/2ms, Half sine wave, ±X, ±Y, ±Z one
time for each direction
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1 Note 2
Note 1
Note 1 Note 2
Note 1 Note 2
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
5. Safety
5-1. Sharp edge requirements
There will be no sharp edges or corners on the display assembly that could cause injury.
5-2. Materials
a. Toxicity
There will be no carcinogenic materials used anywhere in the display module. If toxic materials
are used, they will be reviewed and approved by the responsible InnoLux Toxicologist.
b. Flammability
All components including electrical components that do not meet the flammability grade UL94-V0
in the module will complete the flammability rating exception approval process. The printed circuit
board will be made from material rated 94-V0 or better. The actual UL flammability rating will be
printed on the printed circuit board.
SPEC NO.
PAGE
BT101IW03 V.1
18/ 27
c. Capacitors
If any polarized capacitors are used in the display assembly, provisions will be made to keep
them from being inserted backwards.
6. Display quality
The display quality of the color TFT-LCD module should be in compliance with the InnoLux
incoming inspection standard.
www.jxlcd.com
www.jxlcd.com
7. Handling precaution
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The
dust and oil may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and
Backlight will be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and
operating.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is
very soft and easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture
may damage LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD
module within the specified storage conditions.
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
X
SPEC NO.
PAGE
BT101IW03 V.1
19/ 27
8. Label Definition
8-1. Module label
BT101IW03 V.1 AB1010003 10X
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
Non-Interlace, Normal display, no stereo, Digital Separate
47
48 Flag 00 00000000
49 Flag 00 00000000
Timing
Descriptor #2
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
4A Flag 00 00000000
4B Data Type Tag (Descriptor Defined by manufacturer ) 00 00000000
(sDRRS 40Hz)
( Vsync_NEG, Hsync_NEG ), DE only note : LSB is set to '1' if panel is
DE-timing only. H/V can be ignored.
18 00011000
A
4C Flag 00 00000000
4D Descriptor Defined by manufacturer 00 00000000
4E Descriptor Defined by manufacturer 00 00000000
4F Descriptor Defined by manufacturer 00 00000000
50 Descriptor Defined by manufacturer 00 00000000
51 Descriptor Defined by manufacturer 00 00000000
52 Descriptor Defined by manufacturer 00 00000000
53 Descriptor Defined by manufacturer 00 00000000
54 Descriptor Defined by manufacturer 00 00000000
55 Descriptor Defined by manufacturer 00 00000000
56 Descriptor Defined by manufacturer 00 00000000
57 Descriptor Defined by manufacturer 00 00000000
58 Descriptor Defined by manufacturer 00 00000000
59 Descriptor Defined by manufacturer 00 00000000
5A Flag 00 00000000
5B Flag 00 00000000
5C Flag 00 00000000
5D Data Type Tag ( ASCII String ) FE 11111110
5E Flag 00 00000000
5F ASCII String "I" 49 01001001
60
SCII String "N" 4E 01001110
SPEC NO.
PAGE
BT101IW03 V.1
26/ 27
Timing Descriptor #3 (Dynamic DCLK)
(Brightness Table)
Timing Descriptor #4
61 ASCII String "L" 4C 01001100
www.jxlcd.com
www.jxlcd.com
62 0A 01000100
63 20 01101001
64 20 01110011
65 20 01110000
66 20 01101100
67 20 01100001
68 20 01111001
69 20 00001010
6A 20 00100000
6B 20 00100000
6C Detailed timing/monitor 00 00000000
6D descriptor #4 00 00000000
6E Flag 00 00000000
6F Data Type Tag FC 11111100
70 Flag 00 00000000
71 Manufacture P/N "B" 42 01000010
72 Manufacture P/N "T" 54 01010100
73 Manufacture P/N "1" 31 00110001
74 Manufacture P/N "0" 30 00110000
75 Manufacture P/N "1" 31 00110001
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
Checksum
76 Manufacture P/N "I" 49 01001001
77 Manufacture P/N "W" 57 01010111
78 Manufacture P/N "0" 30 00110000
79 Manufacture P/N "3" 33 00110011
7A Manufacture P/N "V" 56 01010110
7B Manufacture P/N "1" 31 00110001
7C 0A 00001010
7D 20 00100000
7E
7F
Extension flag
(# of optional 128 panel ID extension block to follow, Typ = 0)
Check Sum
(The 1-byte sum of all 128 bytes in this panel ID block shall = 0)
SPEC NO.
PAGE
BT101IW03 V.1
27/ 27
00 00000000
C1 11000001
www.jxlcd.com
www.jxlcd.com
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, OR
TRANSFORMED TO ANY OTHER FORMS WITHOUT PERMISSION FROM INNOLUX DISPLAY CORPORATION.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.