![](/html/61/61ab/61abf387e99cd54483f54624b3be0f31ddc4c955bec6cb04a726d244811e7e07/bg1.png)
innoflame
FIREPLACE OPERATING MANUAL
The actual appearance should be subject to the purchase model
Thank you
Thank you and congratulations on your
purchase of our fireplace. Please read the
Installation instructions carefully before
using this fireplace.
CONSUMER SAFETY INFORMATION: PLEASE READ THIS MANUAL BEFORE
INSTALLING AND OPERATING THIS FIREPLACE. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY RESULT IN A POSSIBLE ELECTRIC SHOCK, FIRE
HAZARD , AND/OR INJURY AND WILL VOID THE WARRANTY.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED, AN
ELECTRIC SHOCK OR FIRE MAY RESULT IN PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
MODELS:
RV23D80L-1
RV26D80L-1
RV30D80S-1
RV48D80L-1
![](/html/61/61ab/61abf387e99cd54483f54624b3be0f31ddc4c955bec6cb04a726d244811e7e07/bg2.png)
IMPORTANT INSTRUCTIONS
When using fireplace, basic precautions should always be followed to reduce the risk of fire, electrical shock, and/or injury including the following:
1. Read all instructions before using this fireplace.
2. This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this fireplace.
DANGER: High temperature may be generated under certain abnormal conditions. Do not partially
or fully cover or obstruct the front of the fireplace.
WARNING: In order to avoid overheating, do not cover the fireplace. It cannot be used in a closet.
3. CAUTION: The fireplace should not be used by children or persons with reduced physical, sensory or mental capabilities.
4. Children should be advised not to play with the fireplace.
5. The fireplace is suitable for using in a recreational vehicle.
6. Do not operate any fireplace with a damaged cord or plug or after the fireplace malfunctions, or
if it has been dropped or damaged in any manner.
7. If the supply cord is damaged, it must be replaced by the manufacturer, it’s service agent or similarly qualified persons in order to avoid a hazard.
8. Any repairs to this fireplace should be carried out by a qualified electrician.
9. Under no circumstances should this fireplace be modified. Parts having to be removed for servicing must be replaced prior to operating this fireplace again.
10. Do not use outdoors.
11. This fireplace is not intended for use in bathrooms, laundry areas and similar indoor locations.
Never locate this fireplace where it may fall into a bathtub or other water container.
12. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange
cord away from traffic areas and where it will not be tripped over.
13. To disconnect this fireplace, turn controls to the off position, then remove plug from outlet.
14. Connect to properly grounded outlet only.
15. This fireplace, when installed, must be electrically grounded in accordance with local codes or,
in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for USA
installations, follow local codes and the National Electrical Code, ANSI/NFPA NO.70.
16. There is a protective thermostat limiter inside the fireplace. When the inner temperature over
heat, the thermostat limiter will shut off the power supply to avoid the risk of fire damage to the
fireplace.
17. The fireplace must not be located immediately below a socket-outlet.
18. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may
cause an electric shock or fire, or damage to the fireplace.
19. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft
surfaces, like bed, where opening may become blocked
20. This fireplace has hot and arcing or sparking parts inside. Do not use where gasoline, paint, or
flammable liquids are used or stored. This fireplace should not be used as a drying rack for clothing.
Christmas stockings or decorations should not be hung in area of it.
21. Use this fireplace only as described in the manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
22. Always plug fireplace directly into a wall outlet/receptacle. Never use with an extension cord or
relocatable power tap (outlet/power strip).
SAVE THESE INSTRUCTIONS
2
![](/html/61/61ab/61abf387e99cd54483f54624b3be0f31ddc4c955bec6cb04a726d244811e7e07/bg3.png)
INSTALLATION INSTRUCTIONS
Fireplace DimensionsCabinet Dimensions
Model NO. W D H
RV23D80L-1
RV26D80L-1
25.5”
RV30D80S-1
RV48D80L-1
D
Model NO. W D H
RV23D80L-1
18.3”6.2”
RV26D80L-1
21.9”22.3” 6.2” 18.3”
25.1”
RV30D80S-1 29.2”29.7” 6.2” 14.9”
RV48D80L-1
41”41.5” 6.2” 18.3”
4.7” 18.1”
4.7”
18.1”
4.7” 14.7”
4.7” 18.1”
H
H
W
W
Electrical Specifications
120V 60Hz 1400W
Grounding Instructions:
This fireplace is for use on 120 volt circuits. The cord
has a plug as shown at (A) in figure 1.An adapter as
shown at (C) is available for connecting three-blade
grounding-type plugs to two-slot receptacles. The
green grounding lug extending from the adapter must
be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be
used if a three-slot grounded receptacle is available.
D
Grounding Pin
Cover of Grounded Outlet Box
Adapter
Grounding Lug
Metal Screw
Cover of Grounded Outlet Box
Figure 1
C
A
B
NOTE: Adapters are NOT for use in Canada
3