Inkbird ITC-1000F User Manual

ITC-1000F Temperature Controller
Manual
Thank you very much for selecting INKBIRD products. Read the instruction manual carefully before use, for right application and maintenance.
Safety Precautions
occasionally result in injury due to electric shock.
Do not allow pieces of metal, wire clippings, or fine metallic shaving or filings from
installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction.
Do not use the product where subject to flammable or explosive gas. Otherwise,
injury from explosion may occasionally occur.
Never disassemble, modify or repair the product or touch any of the internal parts.
Electric Shock, fire, or malfunction may occasionally occur.
If the output relays are used past their life expectancy, contact fusing or burning may
occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. The life expectancy of output relays varies considerably with the output load and switch conditions.
Main Function:
Fahrenheit and Celsius Display Can Be Choose  More User-friendly Operating  Switch Between Cooling and Heating Modes  Control the Temperature by Setting the Temperature Set Value and the Difference
Value
Temperature Calibrating  Refrigerating control output delay protection  Alarm When Temperature Exceeds the Limit or When Sensor Error
Mounting dimension:
Front Panel Size: 75(L)*34.5(W)mm Mounting Size: 71(L)*29(W)mm Product Size75(L)*34.5(W)*85(D)mm Sensor Length: 2m (include the probe)
http://waterheatertimer.org/Add-another-thermostat-to-gas-or-electric-water-heater.html#PID
Technical Parameter:
Temperature Measuring Range: -50210 oF / -50 oC-99 oC Resolution: 0.1 oF / 0.1 oC Accuracy: ±1 oF-50 oF -160 oF/ ±1 oC-50 oC -70 oC Power Supply: 110VAC 50Hz/60Hz Power Consumption: <3W Sensor: NTC Sensor Relay Contact Capacity: Cooling (10A/250VAC)/ Heating (10A/250VAC); Ambient Temperature: 0 oC-60 oC Storage Temperature: -30 oC-75 oC Relative Humidity: 20-85% (No Condensate)
Panel Instruction:
Key Operating instruction:
1. Check Parameter: In normal working status, press “ key once, it will display the setting temperature
value; press “ ” key once, it will display the difference value;
2. Parameter Setting: In normal working status, keep pressing for more than 3s to enter set mode, set
indicator lamp is on, screen displays the first menu code “TS”. Press “ ” key or “ ” key to move up or down the menu item and display the menu