Installation and programming manual
Options and programming methods 61
Confirm with *
The control panel will consider the voice call successful when the call
recipient presses “
*
” on their telephone keypad.
The control panel will consider the voice call
successful as soon as it starts the voice
message.
NoUserTamp.reset
No user will be allowed to delete of the following events:
• terminal tamper
• control panel open-tamper
• control panel dislodgement-tamper
• peripheral tamper
• peripheral loss
•false key
Encrypt data
The encryption of data over the Ethernet network will be enabled only for
SmartLAN/SI communications.
In this case, it is necessary to enable data encryption also when
programming the SmartLAN/SI. This programming process is possible only
via the SmartLeague software programme.
Instant restoral
The restoral of the magnetic reed sensor in Air2-MC100 and Air2-MC200
wireless detectors will be signaled instantly.
Reset of the magnetic reed sensor in wireless
detectors will be signalled with a delay of up to
10 seconds (maximum).
Teleserv. hidden
The symbol will not be shown on the keypad display.
If Teleservice is enabled, the symbol will be
shown on the keypad display.
LockInstall.Code
After hard reset (refer to paragraph 7-25 Default settings), all the control
panel parameters with the exception of the installer PIN will reset to the
factory default settings.
After hard reset (refer to ), all the control panel
parameters including the installer PIN will reset
to the factory default settings (installer PIN
default is 9999).
50131ReaderLedOFF
If there are no keys present at the reader, the LEDs of nBy readers will be
Off. If a key is waved across the reader, the status will be indicated on the
LEDs for 30 seconds before switching Off again.
During this 30 second phase, the user can hold the key in the vicinity of the
reader and select the desired shortcut indicated by LEDs.
The reader LEDs indicate the related status.
50131StatHidden
The status of the partitions will be hidden.
If a valid code is entered at a
keypad, the real-time status will be indicated on the keypad concerned for
30 seconds.
If the partitions are armed, the status of the system will be hidden from nonauthorized users.
•Red keypad LED Off
•Yellow keypad LED Off
•Green keypad LED On solid
• Status icons not present
• Alarm and Tamper memory hidden
• If a particular event occurs more than 5 times when the partitions are
armed, it will not be signaled as having occurred more than 5 times. This
is due to the limitation placed on the counter of each event. The counters
will reset to zero each time all the partitions are disarmed.
If the partitions are DISARMED:
• The LEDs will function normally.
• Status icons present
• Alarm and Tamper memory visible
The keypad will show the real-time status of the
system at all times, regardless of the status of
its partitions.
50131IconsHidden
If partitions are armed, the status icons will not be shown on the second line
on the keypad, thus non-authorized users will be unable to view the
respective conditions on the system.
If a valid code is entered at a keypad, the status of the icons will be shown
for 30 seconds.
The keypad will show the real-time status of the icons when all the keypad
partitions are disarmed.
The keypad will show the real-time status of the
icons at all times, regardless of the status of its
partitions.
50131AlarDelayed
If an instant-zone alarm occurs on a partition while entry time is running, the
associated actions (calls, output activation, save to log, etc.) will not be
generated until 30 seconds after the expiry of the entry time.
If the partition (or partitions) are disarmed during this period, the associated
actions will not be generated, however, the keypads will indicate the violation
of the instant zone.
If an instant-zone alarm occurs on a partition
while entry time is running, the associated
actions (calls, output activation, save to log,
etc.) will be activated instantly.
50131WarnLedMem
If the control panel detects a fault, the yellow LED on the keypads will go On
and will remain On even after the fault clears.
To switch the yellow LED Off, clear all activating causes and reset the
partition.
If the control panel detects a fault, the yellow
LED on the keypads will go On and will go Off
automatically when the fault clears.
DayLightSav.time
The control panel clock will go back automatically one hour at 03:00 last
Sunday in October, and it will go forwards automatically one hour at 02:00
last Sunday in March.
No automatic clock forward/back operations.
NoStrings SiaProt
The descriptive strings will not be sent in SIA reporting format.
The descriptive strings will be sent in SIA
reporting format.
Call all SIA-IP
If several SIA-IP calls - generated by the same event - are waiting in the
outgoing call queue, the control panel will attempt to call all the specified
numbers.
If several SIA-IP calls - generated by the same
event - are waiting in the outgoing Call Queue,
the control panel will send voice calls until just
one ends successfully.
Table 7-1:
Panel options
Option If enabled If disabled