INID ISOACRDR, ISORDR User Manual

Page 1
INID ISO14443 readers
Specifications
Typical read range
Model Mifare ISO card
INID ISO14443 AC 60 mm 2.4 inch INID ISO14443 30 mm 1.2 inch
Power Supply
7 - 24 Volt DC (12 VDC recommended)
Power consumption
INID ISO14443 AC 1300 mW 1750 mW INID ISO14443 AC PIN 1300 mW 2050 mW INID ISO14443 500 mW 950 mW INID ISO14443 PIN 500 mW 1250 mW
Current consumption @12 VDC
INID ISO14443 AC 110 mA 146 mA INID ISO14443 AC PIN 110 mA 171 mA INID ISO14443 42 mA 79 mA INID ISO14443 PIN 42 mA 105 mA
1)
Use Ohm's law to calculate current at different voltages.
Interface
Inputs type and protection specifics Outputs type and protection specifics
Dimensions
143 x 50 x 25 mm / 5.63 x 2 x 1 inch
Material
UL94-V0 rated LEXAN® 925U
Operating temperature
-25° to 65° C / -15° to 150° F
Protection class
IP54 Complete protection against contact,
protection against dust deposit. Protection from splashed water.
1)
Cable specifications (non-shielded)
interface
Wiegand
maximum
cable length
meters feet mm
61 200 91 300
min.conductor size
with 12 V supply
2
2)
AWG
0.25 24
152 500 0.34 22
Clock/Data 25 80
TTL serial 1.5 5
RS232 2.4 8
RS485/RS422
(cable power)
RS485/RS422
(local power)
CAN bus system / speed dependent
2)
With a 24V supply, minimum conductor size is AWG 24 for all
interfaces and lengths.
61 200
152 500 0.34 22
1220 4000 0.25 24
0.25 24
Features
INID readers have a slim mullion mountable design and are designed for both in- and outdoor use. The INID reader can be mounted on any surface without significant performance degradation. For mounting to a metal surface however, a non-metallic spacer is advised. The switch mode power supply of the reader accepts a wide range input from 7 - 24 VDC. Higher input voltages result in lower current consumption and allow for cost effective wiring with a smaller conductor diameter. Reader output formats are determined by the personalization of the card and/or configuration of the reader. Separate models are available for card-only and card+PIN; for Access Control with a larger read range and low power with a smaller read range. Electrical interface options for WG/C&D/TTL serial, RS485/RS422, RS232 and CAN bus are available with separate models.
PIN code
INID PIN readers provide extensive options for PIN data formats and output protocols. The card and PIN code data is sent separately and independently allowing host system determined operation for card­only, PIN-only and card and PIN usage.
Indications
User feedback is provided by a single LED bar and a multi-tone sounder. User feedback is controllable by the host system. PIN models are equipped with back lighting of the PIN code digits for usage in dark environments.
Operation
When a proximity card is read successfully the card associated code is send to the Host system, the LED bar lights briefly and the sounder sounds a short tone. When a PIN is entered the data is transmitted; at each key press a click sound is produced and the LED bar lights briefly. The back light of the PIN code lights up after a successful card read or at the first key press. The LED bar or individual LED bar segments and the buzzer are also controllable by the Host system.
INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011
Page 2
Connector Assignments
Wiegand / Clock and Data / TTL serial
500-5000 INID ISO14443 AC reader WG/C&D/TTL 500-5040 INID ISO14443 AC PIN reader WG/C&D/TTL 500-5100 INID ISO14443 reader WG/C&D/TTL 500-5140 INID ISO14443 PIN reader WG/C&D/TTL
1 LED 1 - Green 5 BUZZER RXD 2 LED 2 - Amber 6 TAMPER 3 D1 DATA TXD 7 GND 4 D0 CLOCK TXE 8 POWER
RS485 / RS422
500-5010 INID ISO14443 AC reader RS485/RS422 500-5050 INID ISO14443 AC PIN reader RS485/RS422 500-5110 INID ISO14443 reader RS485/RS422 500-5150 INID ISO14443 PIN reader RS485/RS422
1 LED 1 - Green 5 RS485 n.c. RS422 RX­2 LED 2 - Amber 6 RS485 n.c. RS422 RX+ 3 RS485 TRX+ RS422 TX+ 7 GND 4 RS485 TRX- RS422 TX- 8 POWER
Caution:
Ensure all communication lines are properly biased and terminated.
floating communication lines may cause spurious emissions.
RS232
500-5020 INID ISO14443 AC reader RS232 500-5060 INID ISO14443 AC PIN reader RS232 500-5120 INID ISO14443 reader RS232 500-5160 INID ISO14443 PIN reader RS232
1 LED 1 - Green 5 RTS 2 LED 2 - Amber 6 RXD 3 CTS 7 GND 4 TXD 8 POWER
CAN bus
500-5030 INID ISO14443 AC reader CAN bus 500-5070 INID ISO14443 AC PIN reader CAN bus 500-5130 INID ISO14443 reader CAN bus 500-5170 INID ISO14443 PIN reader CAN bus
1 LED 1 - Green 5 n.c. 2 LED 2 - Amber 6 n.c. 3 CANL 7 GND 4 CANH 8 POWER
Parts list
1 Reader front qty: 1 2 Terminal connector qty: 1 3 Mounting backplate qty: 1 4 Enclosure screw qty: 1 5 Installation sheet qty: 1
Installation instructions
1 Determine an appropriate position for the reader
and drill two holes for mounting the backplate and one hole for the cable, see diagram for measurements. Do not mount readers less than 20 cm (8 inches) apart.
2 Pull the cable trough the hole in the backplate
and mount the backplate. Protect the cable against sharp edges and any damage from chafing.
3 Remove the terminal connector from the front of
the reader. Prepare the end of the cable and wires, eliminate any loose or frayed strands. Keep the wire ends as short as practical.
4 Connect the wires to the connector according to
the reader type. Wire ends, termination resistor leads and optional permanent links shall be kept
as short as possible. 5 Place the connector on the reader pins. 6 Place the reader front over the hinge of the
backplate and close the reader (see diagram),
keeping the wiring in the lower part of the reader
housing. DO NOT use excessive force, retract the
cable if necessary.
For mounting, use only flat head screws with a maximum shank size of 4 mm (5/32”, #7)
7 Test the reader: apply power and present a valid
card. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to LED bar and sounder inputs these should follow the functionality of the Host system.
8 The reader front should now be secured to the
backplate using the supplied enclosure screw.
Certifications
CE, FCC
FCC ID: YAB-ISOACRDR (model 50XX)
YAB-ISORDR (model 51XX)
Compliance statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received, including interference that may cause undesired operation.
Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with the reader.
Consult your National Authority if any authorization is needed for this product.
INID BV
Kollenbergweg 78c 1101AV Amsterdam Zuidoost The Netherlands Phone: +31 (0)20 6967 441 Web: www.inid-readers.com
INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011