30" Freestanding Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
IGS325R
IGS326R
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas supply: Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 1/2-inch or
3/4-inch I.D., be used for connecting the range to
the rigid gas supply line. A 1/2" male pipe thread is
needed for connection to pressure regulator
female pipe threads. An easily accessible individual
manual shutoff valve must be located in the same
room, but external to the range.
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp,
fused electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this dryer be provided.
Ref. 9760030
05-02-05
TM
29-7/8" (75.9 cm) width
46-7/8"
(119.1 cm)
overall
height
25" (63.5 cm)
36"
(91.4 cm)
cooktop
height
27-1/8"
(68.9 cm)
depth with
handle
*
NOTE:
24" (61 cm) min. when bottom of
wood or metal cabinet is protected by not
less than 1/4" (6.4 mm) flame retardant
millboard covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum or 0.020"
(0.5 mm) copper.
30" (76.2 cm) min. clearance between the
top of the cooking platform and the bottom
of an unprotected wood or metal cabinet.
IMPORTANT: Some cabinet and building
materials are not designed to withstand the
heat produced by the oven for baking and
self-cleaning. Check with your builder or
cabinet supplier to make sure that the
materials used will not discolor, delaminate
or sustain other damage.
18" (45.7 cm)
upper cabinet
to countertop
2" (5.0 cm) min.
clearance from both
sides of range to
side wall or other
combustible
(20.3 cm)
material.
4 ¹⁄₂"
(11.4 cm)
13" (33 cm) max.
upper cabinet depth
30" (76.2 cm) min.
opening width
30¹⁄₈" (76.5 cm) min.
opening width
8"
(20.3 cm)
8"
17" (43.2 cm)
2" (5.1 cm)
For minimum
clearance to
top of cooktop,
see NOTE.
This shaded area
recommended for
installation of
rigid gas pipe.
4 ¹⁄₂"