Inglis YWED9270XR, YWED9270XL, YWED9250WW, YWED9250WR, YWED9250WL Installation Instructions

...
Gas Dryer Installation Instructions
Canadian Electric Dryer Installation Instructions
Instructions pour l’installation de la sécheuse à gaz
(É.-U. et Canada) et électrique (Canada uniquement)
Table of Contents
DRYER SAFETY ................................................................2
INSTALLATION REQUIREMENTS .................................... 4
Tools and Parts .................................................................... 4
Location Requirements ...................................................... 5
Electric Dryer Power Hookup-Canada Only ..................... 7
Gas Dryer Power Hookup ................................................... 8
VENTING .................................................................................... 10
Venting Requirements .......................................................10
Plan Vent System ............................................................... 11
Install Vent System ............................................................ 12
INSTALL LEVELING LEGS ........................................................ 12
MAKE GAS CONNECTION ....................................................... 13
CONNECT INLET HOSES ......................................................... 13
CONNECT VENT ....................................................................... 15
LEVEL DRYER ........................................................................... 15
COMPLETE INSTALLATION CHECKLIST ............................... 16
DOOR REVERSAL ..................................................................... 16
TROUBLESHOOTING ............................................................... 16
INSTALLATION NOTES
Date of purchase: _________________________________ Date of installation: _______________________________ Installer: ________________________________________ Model number: ___________________________________ Serial number: ___________________________________
Table des matières
SÉCURITÉ DE LA SÉCHEUSE ....................................... 17
EXIGENCES D’INSTALLATION ......................................19
Outillage et pièces ............................................................ 19
Exigences d’emplacement ............................................... 20
Raccordement à l’alimentation électrique de
la sécheuse électrique – Canada seulement .................. 22
Raccordement d’une sécheuse à gaz ............................. 23
L’ÉVACUATION.......................................................................... 25
Exigences concernant l’évacuation ................................ 25
Planication du système d’évacuation ........................... 26
Installation du circuit d’évacuation ................................. 28
INSTALLATION DES PIEDS DE NIVELLEMENT ..................... 28
RACCORDEMENT AU GAZ ...................................................... 29
RACCORDEMENT DU TUYAU D’ARIVÉE D’EAU ................... 29
RACCORDEMENT DU CONDUIT D’ÉVACUATION ................ 31
RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE......................... 31
ACHEVER L’INSTALLATION – LISTE DE VÉRIFICATION ....... 32
INVERSION DE LA PORTE ....................................................... 32
DÉPANNAGE ............................................................................. 32
NOTES CONCERNANT L’INSTALLATION
Date d’achat : _____________________________________ Date d’installation : ________________________________ Installateur : ______________________________________ Numéro de modèle : ________________________________ Numéro de série : __________________________________
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su
producto, visite:
www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad
superior de la puerta.
W10443045B W10443046B-SP
1
DRYER SAFETY
2
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
3
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
Flat-blade screwdriver #2 Phillips screwdriver
Wire stripper (direct wire installations)
1/4" nut driver
(recommended)
Tin snips (new vent installations)
Vent clamps
8" or 10" pipe wrench
Pipe-joint compound
resistant to LP gas
8" or 10" adjustable wrench (for gas connections)
Parts supplied (all models):
Leveling legs (4)
Parts supplied (steam models):
Tape measure
Level
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
4
Pliers
Caulking gun and compound (for installing new exhaust vent)
Utility knife
“Y” connector Short inlet hose
Long inlet hose Rubber washer
Parts package is located in dryer drum. Check that all parts are included.
NOTE: If installing dryer on pedestal, do not use leveling legs.
Optional Equipment: (Not supplied with dryer)
Refer to your Use and Care Guide for information about accessories available for your dryer.
Parts needed: (Not supplied with dryer)
Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
LOCATION REQUIREMENTS
27"
29"
You will need:
A location allowing for proper exhaust installation.
See “Venting Requirements.”
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Cold water faucets located within 4 ft. (1.2 m) of the water ll
valves, and water pressure of 20–100 psi (137.9–689.6 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided.
20–100 psi (138–690 kPa) for best performance.
Level oor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above oor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.
For each arrangement, consider allowing more space for ease of installation and servicing; spacing for companion appliances and clearances for walls, doors, and oor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.
DRYER DIMENSIONS
Front view:
3
/8"
35
(899 mm)
1"
(25 mm)
Side view:
Door open view:
(686 mm)
(736 mm)
Left or
right side
exhaust
7
6
/8"
(174 mm)
471/8"
(1197 mm)
1
/8"
48
(1238 mm)
1
/2"
3
(89 mm)
5
1
/8"
(41 mm)
5
Back view:
1
6
/4"
(159 mm)
Closet installation (dryer only):
Electric
1
28
/8"
(715 mm)
1
/2"
3
(89 mm)
14"
(358 mm)
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 45° F (7° C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.
34" recommended
(864 mm)
18" min.
(457 mm)
4"
(102 mm)
(25 mm)
1"
(25 mm)
Cabinet installation (dryer only):
7"
(178 mm)
1"
3"
(76 mm)
3"
(76 mm)
2
48 in.
(310 cm2)
2
24 in.
(155 cm2)
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
oor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable.
Companion appliance spacing should also be considered.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
4"
(102 mm)
1"
(25 mm)
18"
(460 mm)
1"
(25 mm)
6
Closet Installation (stacked washer and dryer):
6"
(152 mm)
3"
(76 mm)
71"
(1803 mm)
48 in.
(310 cm2)
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY
ELECTRICAL REQUIREMENTS
2
1
5
/
2"
(140 mm)
1"
(25 mm)
1"
(25 mm)
3"
(76 mm)
2
24 in.
(155 cm2)
Custom under counter installation (dryer only):
39" min.
(990 mm)
1"
(25 mm)
1"
(25 mm)
NOTE: Some models not recommended for undercounter installation.
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
Metal exhaust system hardware, available for purchase
from your dealer. For further information, see “Assistance or Service” section in your Use and Care Guide.
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
For gas dryers mobile home installations:
Mobile Home Installation Hold-down Kit Part Number
346764 is available to order. For further information, see “Assistance or Service” section in your Use and Care Guide.
It is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4-wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA
International Certied Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle is within reach of dryer’s nal location.
4-wire receptacle
(14-30R)
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located in “Assistance or Service” section of your Use and Care Guide.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
7
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
GAS SUPPLY REQUIREMENTS
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
re, or electrical shock.
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a qualied electrician.
SAVE THESE INSTRUCTIONS
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualied person make sure
gas pressure does not exceed 13" (330 mm) water column.
Examples of a qualied person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or re.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-certied by CSA International for LP (propane or butane) gases with appropriate conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualied
technician. No attempt shall be made to convert the dryer from the gas
specied on the model/serial rating plate for use with a different gas without consulting your gas company.
8
GAS SUPPLY LINE
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas connection to the dryer.
®†
E
D
tape.
C
A
B
A. 3/8" exible gas connector B. 3/8" pipe to are adapter tting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Gas shutoff valve
1/2" IPS pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
If you are using natural gas, do not use copper tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter tting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
Must include shut-off valve
In the U.S.A.:
An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shut-off valve be installed within six (6) ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.
GAS SUPPLY CONNECTION REQUIREMENTS
Use an elbow and a 3/8" are x 3/8" NPT adapter tting
between the exible gas connector and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a
®†
tape.
listed exible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than 1/2 psi.
DRYER GAS PIPE
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
1
1
/2"
(38 mm)
A
*61/4"
*5 3/4"
(159 mm)
A. 3/8" NPT dryer pipe
* NOTE: If the dryer is mounted on a pedestal, the gas pipe
height must be an additional 10" (254 mm) or 15.5" (394 mm) from the oor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the oor.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
9
VENTING
VENTING REQUIREMENTS
Exhaust hoods:
■ Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as owers, rocks, bushes, or snow).
Recommended Styles:
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or exible metal vent shall be used for exhausting.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
■ Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
■ Do not use plastic or metal foil vent.
Rigid metal vent:
■ Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
■ Must be fully extended and supported in nal dryer location.
■ Remove excess to avoid sagging and kinking that may
result in reduced airow and poor performance.
■ Do not install in enclosed walls, ceilings, or oors.
■ The total length should not exceed 7
3
/4 ft. (2.4 m).
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Elbows:
■ 45° elbows provide better airow than 90° elbows.
Recommended Styles:
Good
Better
Clamps:
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
NOTE: If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or exible metal vents. Review “Vent System Charts” and, if necessary, modify existing vent system to achieve best drying performance.
10
Vent products can be purchased from your dealer. For more information, see “Assistance or Service” section in your Use and Care Guide.