Infloor Thermostat 29052 User Manual

Dial Thermostat
Model 500710
29052 Dial Thermostat
Owner’s Manual
Your new SunStat Dial thermostat is designed to control the voltage to
Please follow this manual for complete installation and operation instructions. If you have any questions or comments, try calling Technical Support at (800) 608-0562.
CAUTION: This is a line voltage device that could cause serious injur y or damage if improperly installed.
1. Preparation
1. Unpack your thermostat and make sure everything is in good condition:
Thermostat
Floor sensor
Small screwdriver
Mounting screws
Wire nuts for wiring connections
If any parts are missing or damaged, contact the store where you purchased this thermostat. Do not install a damaged part.
2. Gather the following tools and supplies:
Phillips screwdriver, hole saw
Electrical box for thermostat: a. systems, you may use a single-gang, 31⁄2 inch deep box. b. use a 4x4x21⁄8 inch or deeper box (not a 2-gang box) when your wall studs are still exposed. Install a single-gang “mud-ring” cover on the box before installing dr ywall materials. c.
warming system for more information.
ALWAYS: Wire all circuits as Class 1, Electric Light and Power Circuits. ALWAYS: Wire all circuits with insulation rated 600V minimum. ALWAYS: Mount this control only to a grounded metallic box or a nonmetallic box. ALWAYS: Use power supply wires suitable for at least 90°C.
CAUTION: High voltage – disconnect power supply before servicing. CAUTION: The GFCI in this control does not protect against shock if both
2. Installation
Remove the Thermostat Face
1. Remove the thermostat Front Module
from the Power Module by opening the door and loosening the screw.
2. Pull outward near the bottom on the Front Module and lift off. Be careful not to bend or damage the 14-pin electrical connector on the back of the Front Module. bottom on the Front Module and lift of f.
Prepare the Wiring
1. Find a location for your thermostat. It is suitable for indoor use only, on
insulated or uninsulated walls. Locate it about 4
heat sources such as hot-water piping, heat duct, wall-mount lighting, and direct sunlight to help prevent adversely affecting the thermostat.
2. before doing any electrical work.
3. panel to the thermostat location.
4. If a dedicated circuit is not possible, you may tap from another circuit in the room. Make sure there is enough load capacity (amps) to handle the addition
bare conductors are touched at the same time.
front module
1
2 feet to 5 feet above the
power module
device, including other GFCIs.
5. The circuit breaker in the main circuit panel should be 15 amps maximum
to 15 amps, use a 20 amp maximum circuit breaker. Never exceed 15 amps on this thermostat. You may consider using an arc-fault (AFCI) type circuit breaker for additional protection.
6. Pull the power supply wiring into this box, leaving about 6 inches of wire.
7.
Note: The sensor wires should not be run in the same conduit as line voltage
wires to avoid possible inter ference. If the sensor lead wires are not long enough, they may be extended an additional 15 feet (4.5 m) using minimum 20-gage 2-conductor wire or up to 50 feet (15 m) using shielded wire.
8. Mount the electrical box.
1-4
from power supply
to
warming system
5
sensor
Connect Wires
1. Match and connect the two
wires marked “LINE1” and “LINE2” to the power supply wires using the wire nuts provided.
2. Gently tug on the wires to make sure they are secure, otherwise a wire could loosen and cause failure.
3. Overwrap the wire nuts with electrical tape to better secure them to the wires.
4. Match and connect the two wires marked “LOAD1” and
system lead wires and secure these wires the same way.
5. Connect the house ground wire to the green or bare lead
system.
6. sensor wire into the “SENSOR” terminals (1 and 2) and tighten the screws. There is no polarity, so it does not matter which wire end goes into which terminal.
CAUTION: Before continuing, make sure your power supply voltage matches the voltage
system.
warming system will cause over­heating and damage to the system and may damage the control, other wiring,
29053V1 Relays
1. If you want to use your thermostat to drive a SunStat Relay(s) (ask
your dealer about this convenient way to control larger systems with one
thoroughly.
2. Pull 2-conductor wire, size 18- to 24-gage, through the wall from the SunStat Relay, into this electrical box. This wire may be up to 100 feet (30 m) in length from the thermostat to the last SunStat Relay installed.
3. Connect the wire ends into the “RELOUT” terminals (3 and 4) and tighten the screws (Observe polarity of the wires when connecting to the SunStat Relay).
Mount the Thermostat
1. Carefully fold and press the wires back into the electrical box. Do not use
the thermostat to push them in, as this may cause connections to loosen and possible failure.
2. Secure the thermostat Power Module into the box with the mounting screws provided.
3. Carefully snap the Front Module onto the Power Module. Be careful not to bend or damage the 14-pin electrical connector on the back of the Front Module.
4. Tighten the screw.
5. Switch on the power at the main circuit
panel.
NOTE to contractors: After installing the thermostat, be sure to:
a. Switch on the thermostat and turn up the temperature to make sure it
is heating for a few minutes (section 3) b. Test the GFCI (section 3).
3. Operation
On/Off Switch
1. Slide the on/off switch to the upper
position, turning the thermostat on. A green light will show on the front indicating the thermostat is turned on. If the light is amber, it
system.
2. To turn the thermostat off any time, slide the on/off switch to the lower position. No heating will occur.
on/off
Adjust the Temperature
1.
2.
Air or Floor Sensing
During installation, your thermostat should have been connected to a
recommended method to properly control the system.
thermostat will sense the air temperature instead, becoming an air
Floor Sense Mode as soon as possible. The air sense mode must be used with
Test the GFCI
There is a GFCI (Ground Fault Circuit Interrupter) inside the thermostat. It
warming system has been damaged.
To make sure the GFCI is operating, test it after it is installed and once each month:
1. Make sure the thermostat is HEATING. You may need to increase the temperature temporarily.
2. Press the GFCI Test button on the side of the thermostat. A red light should show next to the GFCI Test button. You should also hear a click, indicating
Power Supply 120/240 VAC, 50/60 Hz Maximum Load 15 amps, resistive Maximum Power 1800 watts at 120 VAC
3600 watts at 240 VAC GFCI Class A (5 milliamp trip) Setting Range 40 °F to 99 °F (4 °C to 37 °C) Accuracy ± 0.9 °F (0.5 °C) Sensor Thermistor, 10k NTC, double-insulated Storage Temp 0 °F to 120 °F (0 °C to 49 °C) ETL Listing Control No. 3037530
Conforms to UL 873, UL 943, CSA C22.2 No.
24, and CAN/CSA C22.2 No. 144
Limited Warranty
Watts Radiant, Inc. warrants this thermostat control and sensor (the product) to be free from defects in material and workmanship for a period of (2) years from the date of original purchase from authorized dealers. During this period, Watts Radiant, Inc. will replace the product or refund the original cost of the product at Watts Radiant’s option, without charge, if the product is proven defective in normal use. Please return the thermostat to your distributor to begin the warranty process. This limited warranty does not cover shipping costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, diagnosis, removal or reinstallation, or any material costs or loss of use. This limited warranty is in lieu of all other warranties, obligations, or liabilities expressed or implied by the company. In no event shall Watts Radiant, Inc. be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply
other rights that vary from state to state.
IOM-WR-SS-Dial 1125 Effective: 07/01/2011
PPLIMP08007 IND © 2007-2011
indicators fail, turn off the thermostat and replace it. Do not continue to use.
3. To reset the GFCI, slide the On/Off switch off and back on. If the GFCI does not reset, turn the thermostat of f and go to section 4 “Troubleshooting” for help.
4. Troubleshooting
Problem Solution
Thermos tat works but no heat from the system.
No lights showing.
GFCI is tripped.
Right light blinking on front of thermostat.
1. Check wiring connections.
2. If GFCI is tripped, re set thermostat with on/off switch.
manual for system.
1. Check wiring connections.
2. Check circuit breaker or other protection “upstream” of thermos tat.
3. Check the 14-pin connection on the back of the Front Module. Sometimes the pins can become misaligned when connecting the Front Module to the Power Module.
1. Check wiring connections.
2. Reset thermost at by switching off/on.
manual for system.
air sensing.
sensor, or replace thermostat . > 0.1s on / 0.1s of f : “End- of-life” indication. GFCI will no longer func tion correctly or safely. Reset the circuit breaker or replace Relay.
P.O. Box 4945, Buena Vista, Co 81211 (800) 608-0562 info@infloor.com
Loading...