Infloor Loud Mouth User Manual

LoudMouth
O p e r a t i n g I n s t r u c t i o n s
9-volt battery
PREPARATION
1. Open the battery compartment cover and
connect the 9-volt battery included.
2. Replace the battery compartment cover and switch the unit “ON”.
3. The alarm should sound and the red light should be lit when there are no connec­tions to a mat or cable. If these things do not occur, inspect the battery connec­tion or replace the battery.
4. During normal use, the green light indicates that the LoudMouth is monitoring the mat or cable for damage. Should the green light go out, replace the battery before continuing work.
TM
OPERATION
Make sure the mats and/or cables to be monitored are
not connected to a power source.
The LoudMouth is designed to monitor the mats or cables
individually. However, by making a temporary “series” con­nection of multiple mats or cables, it can monitor up to three products at one time.
1. FOR A SINGLE MAT OR CABLE: Insert each lead wire from the mat or cable into the L1 and L2 terminals (no polarity) with the ground wire inserted into the G ter­minal. Tighten the terminal screws onto the wires.
FOR UP TO THREE MATS OR CABLES: Connect one non-ground lead wire from one mat or cable into the L1 terminal. Connect one non-ground lead wire from a DIFFERENT mat or cable into the L2 terminal. Now connect the remaining lead wires so that the mats or cables are in “series” with one another. If this is not done properly, the LoudMouth may not correctly monitor the mats. Lastly, connect all ground wires from the mats or cables together to the G terminal using a jumper wire. See schematics on reverse side
for proper connection to the LoudMouth.
2. Set the switch to the “ON” position.
3. A green light indicates the LoudMouth is operating.
4. Hang or place the LoudMouth
heard during heating product installation.
where it can be seen and
Connect the leads to the LoudMouth. Swith the unit “ON”. The green light
should be lit.
6. Press the TEST button to simulate a damage condition before beginning work and anytime during installation if desired to confirm LoudMouth operation.
Call Infloor Sales & Service at 800 608-0562 if damage or problems occur. Refer to the heating product Installa-tion Manual for detailed installation instruction.
NOTE: The LoudMouth is designed to assist in electrically monitoring Infloor Sales & Serivce electric floor warming products for potential damage during product installation and floor covering installation. Infloor Incorporated in no way ensures that the potential damage will be found by the LoudMouth and is not liable for damage or location, repair, labor, or any other costs associated with damage that is found or not found by the LoudMouth.
5. A red light and alarm indicate lead wires have come loose from terminals or damage has occurred to the heating product.
800-608-0562 / 719 395-3400 (phone) / 719 395-3555 (fax)
P.o. Box 4945 / Buena Vista, Co 81211
Schematic showing how to connect two heating mats or cables to the LoudMouth for monitoring during installation.
Schematic showing how to connect three heating mats or cables to the LoudMouth for monitoring during installation.
Call
Infloor Sales & Service
at 800-608-0562 if damage or problems occur. Refer also to the installation
P.o. Box 4945 / Buena Vista, Co 81211
800-608-0562 / 719 395-3400 (phone) / 719 395-3555 (fax)
Loading...