Infinova V6202IR-TA Series, V6202IR-TX Series, V6202IR-TA/TX Series Instruction Manual

INSTRUCTION MANUAL
V6202IR-TA/TX Series
Notice
Copyright Statement
This manual may not be reproduced in any form or by any means to create any derivative such as translation, transformation, or adaptation without the prior written permission of Infinova. Infinova reserves the right to change this manual and the specifications without prior notice. The most recent product specifications and user documentation for all Infinova products are available on our web site www.infinova.com.
Trademarks
Infinova
®
is a trademark of Infinova.
All other trademarks that may appear belong to their respective proprietors.
FCC Warning
The V6202IR-TA/TX series HD 2MP IR IP cameras comply with the FCC rules.
Operation is subject to the following two conditions:
This device will not cause harmful interference. This device must accept any interference received, including interference
that may cause undesired operations.
The
V6202IR-TA/TX series HD 2MP IR IP cameras have been tested and found
to comply with the limits for a Class A digital device, pursuant to the FCC rules. With these rules and regulations being obeyed to maintain the good working condition of device, the operation is not supposed to be affected by the external interruptions under certain circumstances. This device is electromagnetic, so all the installation and application processing along the device has to follow strictly to the manual or it may hamper the telecommunication around. Meanwhile, there is no guarantee that interference will not occur in a certain particular installation situation.
Read this manual carefully before installation. This manual should be saved for future use.
Important Safety Instructions and Warnings:
Electronic devices must be kept away from water, fire or high magnetic
radiation.
Clean with a dry cloth. Provide adequate ventilation. Unplug the power supply when the device is not to be used for an extended
period of time.
Only use components and parts recommended by manufacturer. Position power source and related wires to assure to be kept away from
ground and entrance.
Refer to qualified personnel for all service matters. Save product packaging to ensure availability of proper shipping containers
for future transportation.
Indicate that the un-insulated components within the product may carry a
voltage harmful to humans.
Indicate operations that should be conducted in strict compliance with
instructions and guidelines contained in this manual.
Warning: To avoid risk of fire and electric shock, keep the product away from rain and moisture!
CONTENTS
Chapter I System Introduction ................... .. ... ........................................ ... .. .. ... 1
1.1 Product Description ................................................................................... 1
1.2 Product Features ........................................................................................ 1
1.3 System Requirement .................................................................................. 2
1.4 Product Model ........................................................................................... 3
1.5 Specifications ............................................................................................. 4
1.6 Notice ......................................................................................................... 6
Chapter II Installation and Port Introduction ................................................. 7
2.1 Installation Precautions ............................................................................. 7
2.2 Installation Procedure ................................................................................ 7
Chapter III IE Browser Settings .................................. .. ... .. .............................. 11
3.1 Equipment Connection ............................................................................. 11
3.2 Software Installation ................................................................................. 11
Chapter IV Basic Function Operation ..................... ... .. .. ................................ 14
4.1 Live View ................................................................................................. 14
4.2 System ...................................................................................................... 17
4.3 Network Settings ..................................................................................... 23
4.4 Camera Settings ....................................................................................... 32
4.5 Audio & Video Settings ........................................................................... 42
4.6 Alarm Settings ......................................................................................... 51
4.7 Record Management ................................................................................ 53
4.8 Account Settings ...................................................................................... 58
4.9 System Log .............................................................................................. 60
Appendix I Magnetic Ring Filter Instruction ................................................. 62
Appendix II Questions & Solutions .................................................. .. ..... ..... .. . 63
Appendix III Cable Diameter Calculation and Lightning & Surge
Protection ............................................................................................................ 64
1
CHAPTER I SYSTEM INTRODUCTION
1.1 Product Description
V6202IR-TA/TX series HD 2MP IR IP camera uses 1/3" progressive scan CMOS sensor. H.264 High profile/M-JPEG video compression format allows image output resolution up to 1920×1080@30fps.
The camera supports three simultaneous video streams, bi-directional audio and G.711 audio compression. Functioned with ICR day/night switch, motion detection, privacy mask, alarm input/ output and local recording, V6202IR-TA/TX series is bound to enhance security and convenience for your CCTV surveillance system.
Boasting of built-in motorized zoom lens with the focal length 2.8-12mm, 4-9mm or 9-22mm optional, V6202IR-TA/TX series can achieve long-distance auto focus.
With Smart-IR technology, the camera effectively avoids the image overexposed and underexposed, with the illumination distance up to 30m or 50m.
V6202IR-TA/TX series is widely used in public security, subways,
governments, schools, airports, factories, hotels, museums, city streets and
other high-resolution surveillance applications.
1.2 Product Features
1/3" progressive scan CMOS sensor IR-Cut Removable (ICR) Filter for Day/Night switching Motorized zoom lens for Auto Focus High-performance IR illuminators, 30m or 50m illumination distance Smart-IR technology, no image overexposure or underexposure Long service life and easy replacement for the illuminators Supports WDR function
2
Onvif Profile S High-resolution image signal output: up to 1920×1080@30fps Small bandwidth occupancy and high image quality Maximum frame rate: 30fps@1920×1080 Three Simultaneous Video Streams: Dual H.264 & Scalable M-JPEG Smooth dynamic video replay Supports anti-reflection function Bi-directional audio, G.711 Supports storage with TF card Supports active video tampering Motion detection, privacy mask and Local Recording 2 alarm inputs, 1 relay output Supports multiple ways to handle alarms, such as email sending, FTP
upload and relay output
Support simultaneous access and parameter setting via Web Server from
multiple clients
Compatible or able to integrate with Infinova V2216 and other digital video
surveillance software
Standard SDK is provided for easy integration with other surveillance
software
Supports public access With analog video debugging interface IP66 environmental rating IK10 for all metal enclosure
1.3 System Requirement
Configuration of the computer to display image and control the camera : CPU: Intel Pentium 4, 2.4 GHz or above
RAM: 512 MB or greater Network Port: 100M Ethernet port Operating System: Microsoft Windows 7, Microsoft Windows XP
IE Browser Version: Microsoft Internet Explorer 6.0 or above
3
1.4 Product Model
This manual is for the following models:
V6202IR-TA220F HD Megapixel IR IP camera, Day/night, 1/3 inch CMOS
sensor, H.264/M-JPEG, 2.0Mpx, 30m IR range,
PoE/12VDC/24VAC, 4-9mm motorized zoom lens
V6202IR-TA220H HD Megapixel IR IP camera, Day/night, 1/3 inch CMOS
sensor, H.264/M-JPEG, 2.0Mpx, 50m IR range,
PoE/12VDC/24VAC, 9-22mm motorized zoom lens
V6202IR-TA220P HD Megapixel IR IP camera, Day/night,
1/3 inch CMOS sensor, H.264/M-JPEG, 2.0Mpx,
30m IR range, PoE/12VDC/24VAC,
2.8-12mm motorized zoom lens
V6202IR-TX224F HD Megapixel IR IP camera, Day/night, 1/3 inch CMOS
sensor, H.264/M-JPEG, 2.0Mpx, 30m IR range, w/heater,
12VDC/24VAC, 4-9mm motorized zoom lens
V6202IR-TX224H HD Megapixel IR IP camera, Day/night, 1/3 inch CMOS
sensor, H.264/M-JPEG, 2.0Mpx, 50m IR range, w/heater,
12VDC/24VAC, 9-22mm motorized zoom lens
V6202IR-TX224P HD Megapixel IR IP camera, Day/night,
1/3 inch CMOS sensor, H.264/M-JPEG, 2.0Mpx,
30m IR range, w/heater, 12VDC/24VAC,
2.8-12mm motorized zoom lens
4
1.5 Specifications
Model V6202IR-TA2 & V6202IR-TX2 series Image Sensor 1/3" progressive scan CMOS Dynamic Range 72.4dB
Lens
V6202IR-TA220F, V6202IR-TX224F: F1.2, f=4-9mm; horizontal angle: 62.8°(wide)~35.2°(tele); V6202IR-TA220H, V6202IR-TX224H: F1.5, f=9-22mm; horizontal angle: 31.6°(wide)~14.5°(tele) V6202IR-TA220P, V6202IR-TX224P: F1.4, f=2.8-12mm; horizontal angle: 80°(wide)~30°(tele)
IR Wavelength 850nm
IR Illumination Distance
V6202IR-TA220F, V6202IR-TX224F: 30m V6202IR-TA220H, V6202IR-TX224H: 30m V6202IR-TA220P, V6202IR-TX224P: 50m
Day/Night Functionality ICR
Sensitivity
Color mode: 0.05lux@F1.2(30IRE, AGC ON ) B/W mode: 0lux (IR on)
Exposure Scene mode, Manual mode, Shutter priority mode Shutter Auto/Manual (1/25s~1/8000s)
White Balance
Auto/Manual/Incandescent light/Cool white fluorescen
t
light/Sun light/Cloudy/Natrium light
Gain Control Auto/Manual Noise Reduction 3D Video Compression H.264 High profile/M-JPEG Maximum Resolution 1920×1080@H.264/M-JPEG
5
Optional Resolution
Major stream: 1920×1080, 1280×1024, 1280×960, 1280×720, 1024×768, 800×600; Minor stream: 720×576, 720×480, 640×480, 352×288, 352×240
Maximum Frame Rate 30fps@1920×1080
Data Rate
Variable bit rate; Constant bit rate: 256Kbps~10000Kbps
Network Delay 250ms
Audio
Audio Compression: G.711-u; 1 input (Linear level, Resistance: 1000 Ohm), 1 output (Linear level, Resistance: 600 Ohm)
Motion Detection Up to 4 areas
Privacy Mask Up to 4 masks Local Recording Ava ila bl e
TF Card Storage Available, up to 32G
Upgrade Online Avai lab le Password Protection Ava ila bl e Network Port One RJ45 10/100M self-adaptive Ethernet port
Applicable Protocols
IPv4, IPv6, TCP, UDP, IGMP, DHCP, FTP, SNMP (V3), SMTP, NTP, RTP, RTSP, RTCP, HTTP, HTTPS, TSL, SSL, 802.1X, QoS, PPPoE, DNS, ARP, ICMP, UPNP, DDNS, Profile S
Alarm 2 alarm inputs, 1 relay output
Power Supply
V6202IR-TA: PoE IEEE 802.3af Class 3/12VDC/ 24VAC; V6202IR-TX: 12VDC/24VAC
Power Consumption
V6202IR-TA: 11W (1.5A at 12VDC); V6202IR-TX: 20W (w/heater) (2.5A at 12VDC)
6
Operating Temperatur e
V6202IR-TA Series: -4°F~140°F (-20°C~60°C) V6202IR-TX Series: -40°F~140°F (-40°C~60°C) (w/heater)
Storage Temperature -4°F~140°F (-20°C~60°C) Operating Humidity 0%-90% RH (non-condensing) Dimensions (H×W×L) 3.74"×4.02"×12.91" (95mm×102mm×328mm)
Box Dimensions (L×W×H)
14.96"×7.87"×5.91" (380mm×200mm×150mm)
Unit Weight 3.86lbs. (1.75kg) Shipping Weight 4.92lbs. (2.23kg)
1.6 Notice
1. Firstly perform network settings after login. The gateway IP address should
be set as that of the connected to the network camera.
2. The IP address is not allowed to conflict with that of other devices; otherwise,
you cannot visit the camera.
3. If the purchased IP camera utilizes PoE power supply, please connect
equipments according to the parameter of the Power Supply Switcher strictly.
Furthermore, practical test of maximum network cable length for the Power
Supply Switcher must be performed, so as to avoid the camera failure caused
by insufficient power supply of the Power Supply Switcher, or to avoid the
destruction of Switcher.
7
CHAPTER II INSTALLATION AND PORT INTRODUCTION
2.1 Installation Precautions
Do not drop the camera or subject it to strong knock.
Do not point the camera lens toward the sun or other strong light.
Do not install the camera in environment with temperature beyond the
acceptable range (from -20°C to 60°C), or with high humidity, direct
rainfall, frequent vibrations and shocks.
Do not expose the tailing line to direct sunlight or rain.
In case of rain leakage, please drag the tailing line from special wiring slot
and ensure the vertical arrangement of the line.
Make sure to choose the suitable position that can support the weight of the
camera and the bracket in years and fix them properly.
Exercise maximum caution when installing the unit to the wall or ceiling.
You should not engage in the installation work yourself. Ask a professional
to do the job, since the fall of the unit can result in injuries and accidents.
As a failsafe against falling, attach the unit by chain, wire cable or other
safety restraint to an appropriate anchor point.
Open the back panel to insert TF card should be performed in a dry
environment. To prevent the camera module moistened and dusted, cover
with the back panel quickly after TF card is installed.
Do not open the front panel to adjust the built-in motorized zoom lens.
2.2 Installation Procedure
Step 1: TF Card Installation
Note: if there is no need to install TF card, skip to Step 2.
See the figure below for the back panel:
8
(Unit: inch, in the parentheses is mm)
Figure 2-1
Unscrew the three screws in the back panel and take off the panel. The TF card
slot will appear, as shown in figure below:
Figure 2-2
Insert TF card, cover with the back panel and fasten the screws.
Note: in this process, pay extra attention to keep cables connection tightly. Do
not squeeze up the cables.
9
Step 2: Camera Installation
The mounting bracket is enclosed.
Drill mounting holes in the desirable position, as the figure below:
Figure 2-3 Camera mounting holes
Mount the camera to the suitable position.
Step 3: Cable Connection
The camera has a pigtail. It includes power wire, network wire, audio input and
output wires, alarms input and relay output wires, grounding wire, analog video
wire and reset button.
Do correctly connect all the wires as per the labels.
The camera supports bi-directional audio, providing with 1-ch audio input and
1-ch audio output. It also supports 2-ch alarm inputs and 1-ch relay output. In
addition to 12VDC/24VAC power supply, the camera can work on power over
Ethernet (PoE).
Step 4:
Camera Angle Adjustment
Check whether the wires are properly and firmly connected before powering
on. Remember to visit the device about 60 seconds after power-on. At this
moment, loosen the M4×20 inner hexagon screw in the bracket and the M6×8
setscrew with an Allen wrench, and adjust the camera angle according to your
surveillance need. Then fasten the screws.
10
Setscrew of Bracket A, M4×20
Bracket A
Bracket B
Setscrew of Bracket B, M6×8
Figure 2-4
Camera angle adjustment method:
Loosen the M6×8 setscrew of Bracket B to rotate Bracket B; Loosen the
M4×20 setscrew of Bracket A to adjust Bracket A. You can adjust the camera
angle through adjusting Bracket A and Bracket B.
Dimensions (Unit: inch, in the parentheses is mm)
12.91(328)
7.87(200)
Figure 2-5
11
CHAPTER III IE BROWSER SETTINGS
When view the video, the user need to adjust the IE browser of the monitor or
other video devices, and set proper system function based on the following
instructions:
Support IE browser version: Internet Explorer 6.0 or above;
Must install InfiPlayerAX control and equip with Directx 9.0c.
3.1 Equipment Connection
V6202IR-TA/TX series IP camera can be directly connected to a computer, or
connected to a network. Note: Check whether the connection is tight or not before power-on.
3.2 Software Installation
The installation procedures of V6202IR-TA/TX series camera image software
are listed as follows:
(1) Login
First, start IE browser and enter IP address. Enter user name and password in
the pop-up login interface.
The default IP address is http://192.168.1.100; the default subnet mask is
255.255.255.0 and the default gateway IP address is 192.168.1.254. For normal
access, correctly set local IP parameters before system login.
Do log in the system with the default super user for the first time to run the
software. The default Super User is admin (password: admin).
(2) Install and run Control
There are two ways to install control.
Method 1:
The prompt message as below will come out in live view window after a
successful login. Click the link to run, or store the exe file, then run it.
12
Figure 3-1
If the installation fails, check whether there is video viewed through other IE
window or page. You should close the video or the IE window directly.
If it successes, click refresh, you can view the live video.
Method 2:
The prompt message as below will come out in the page after a successful
login. Right click “Add-on Disabled” and select “Run Add-on”.
Figure 3-2
Then the prompt of security warning will pop up to remind the user to install
InfiPlayerAX control. Click “Install”.
Figure 3-3
After InfiPlayerAX control is installed, you can view the live video. If it pops
up reboot prompt, please cancel reboot. Then close all the IE window and
install InfiPlayerAX control once again. The live video will display as below:
13
Figure 3-4
Note:
If InfiPlayerAX control installation falls, the live video won’t display. Then,
you should change the IE security level.
1. Select “Tool” in the menu bar, and then select “Internet Options” from the
drop-down menu.
2. Select “Security” in the pop-up Internet options.
3. Click “Internet” icon and then click “Custom Level”.
4. Select “Enable” or “Prompt” in the options of “Download unsigned ActiveX
controls”.
5. Click
Privacy in the “Internet”, clear “Block pop-ups”, then redraw the screen
and install control as per the prompt. The live video will display.
By now, the IE browser setting for image view comes to an end.
14
CHAPTER IV BASIC FUNCTION OPERATION
This chapter mainly introduces the settings and operation of V6202IR-TA/TX
series.
4.1 Live View
Start IE browser after the server is powered on for about 75 seconds, and then
enter IP address, such as http://192.168.1.100 (default), in the address field.
Note: The default subnet mask is 255.255.255.0 and the default gateway IP
address is 192.168.1.254. For normal access, please correctly set local IP
parameters before system login.
The login interface is displayed as shown in figure below in English operating
system.
Figure 4-1 User Login
Do log in the system with the default super user for the first time to run the
software. The default Super User is admin (password: admin). Input the correct
user name and password and then click “OK” button to log.
After login is successful, the following interface will display:
15
Figure 4-2
H.264 Live view
V6202IR-TA/TX series IP camera supports H.264 and M-JPEG video
compression formats. After successful login, it enters H.264 major stream live
video interface. Users can also select H.264 minor stream or MJPEG from the
drop-down list of stream type. In the H.264 major or minor stream type, users
can do recording, snap shooting, audio in/out, motion detection and privacy
mask settings. Over browsing videos, users can also select a proper video
scale.
Play mode: live or fluid for option.
Click the button
to snapshoot and to enter the storage path. Default:
C:\InfiPlayerAX\Picture.
V6202IR-TA/TX series supports local recording. Click the recording button
to start recording; when the button changes to , click it to stop recording.
16
During local recording, “REC” appears on the video screen. Click the button
to enter the recording storage path. Default: C:\InfiPlayerAX\ Video.
Users can set the snap shooting and recording storage path in the audio and
video settings interface.
Indicate audio input/output disabled. Click the buttons to enable audio
input/output and then the buttons will be shown as
.
Indicate that the motion detection and privacy mask functions are
disabled. Click the buttons to enable them and then the buttons will be shown
as
.
Note: only when motion detection or privacy mask is enabled, you can set the
corresponding function in Audio & Video Settings, refer to Section 4.5.3 or
4.5.4 for details.
Note: the login web page language should be set to the same as that of PC’s
operating system.
Click the option tab “Setting” to enter the system setting interface.
17
Figure 4-3 Settings Interface
With the help of navigation menu on the left, Super user can perform the
following operations: Basic Information View, Time Settings and Advanced
Settings, Network Settings, Camera Settings (including Basic Set, Effect Set,
White Balance, Focus, IR set, Reset), Audio & Video Settings, Alarm Settings,
Record Management, Account Settings (Add/Delete User, Change Password),
Log, etc.
Note: The following instructions are used for the super user.
4.2 System
Click the navigation bar “System” and it displays the following three option
tabs: System, Time and Advanced, as shown in Figure 4-3.
18
4.2.1 System Information
The initial interface of System Settings displays related system information,
such as basic system information, network settings, NTP settings, alarm settings,
H.264/MJPEG video settings, etc.
4.2.2 Time Settings
Figure 4-4 “Time” Settings
Time Zone Settings
Time Zone: Select the desired time zone in the scroll box, and then click “Save”
to save it.
There are 33 time zones for your selection.
If Daylight Saving Time is applied in your region, please enable daylight saving
time. After settings completed, please click the button “Save”.
19
NTP Settings
Set the NTP server ’s IP address, test NTP server’s status, and set parameters of
Sync with NTP, including enable/disable Sync with NTP, Sync time and Sync
interval.
After completed, please click the button “Save”.
Sync now
There are two sync modes: local sync and NTP sync.
Local Sync means the system time is consistent with that of local PC. In the
NTP Sync mode, the system will automatically adjust time to the same as that
of NTP Server.
4.2.3 Advanced Settings
Figure 4-5 “Advanced” Settings
Software Update
Free software update is provided for V6202IR-TA/TX series camera, and this
update service can reduce system maintenance budget.
Confirm the requirement submitted by user, we will provide the latest software for download, and help user to update the V6202IR-TA/TX series camera.
20
Follow the steps below to update software:
Click “Browse” button on the interface and the file selection dialog box will
pop up.
Figure 4-6
Select update file, and press “Open” button. The selected update file will be
displayed in the Software Update box.
After that, click “Submit” button to update software, the following information
will appear:
Figure 4-7
Click “Yes” button, run the program to finish the update.
21
The response time is due to the program type. You may wait a long time for
some program. Do not power off during the update process. Power-off will
make update fail, even damage the original program or unable to update again.
After update successfully, it needs to reboot the system. There is time prompt in
the web page during reboot. After reboot, it will skip to new web page to run
new program.
Note: Available only for the super user.
Factory Settings
V6202IR-TA/TX series camera provides online reset function, which greatly
facilitates reset adjustment.
Select “Keep current IP unchanged”, click “Reset” button and the system will
pop up a message as below:
Figure 4-8
Click “OK”, all the parameters (excluding IP address) will be reset to the
factory default settings.
If “Keep current IP unchanged” is unselected, the IP address will be reset to the
factory default settings.
There is time prompt in the web page during reset. After reset, it will skip to
new web page.
If current IP unchanged, you can access web page directly. If IP address resets
to
192.168.1.100, you can’t access web page. Then, you have to set PC’s IP address
to 192.168.1 section, such as 192.168.1.25. After that, access web page
to change
camera’s
IP address and save, PC’s IP address will restore to the corresponding
section.
Note:
22
1. To avoid error happens, the operation of online reset function should be
performed under qualified personnel’s guide.
2. Default IP address is 192.168.1.100, and default subnet mask is
255.255.255.0.
3. Do not power off during reset, or else the reset will fail.
Online Reboot
Click “Reboot” button, the dialog box “This operation will take 75 seconds, are
you sure to continue?”pop up. Click “OK” and the system will restart. There is
time prompt in the web page during reboot. After reboot, it will skip to new
web page.
Note: Available only for the super user.
23
4.3 Network Settings
Click “Network” in the navigation bar, and the following interface will display:
Figure 4-9 Network Settings
11 options tabs are available: Network, FTP, SMTP, HTTPS,
802.1X, QOS,
IGMP, SIP, MDA, DDNS and UPnP.
4.3.1 Network Settings
IP mode: support both IPv4 and IPv6 modes. Network parameters are slightly
different under different IP modes.
24
Figure 4-10 Network Settings
Under IPv4 mode, users can enable or disable DHCP. When it is disabled, users
can set Unit IP address, Subnet mask, Gateway and DNS server IP address
manually. Notes: The system indicator quickly flickers for 5s after the network settings
completed.
Users can also enable/disable PPPoE in this interface. If enabled, users can set
the user name and password.
V6202IR-TA/TX series camera supports heartbeat function. In SNMP settings,
set and save the heartbeat sever IP address and Heartbeat interval, and then the
heartbeat package will be sent to the server or client, which greatly facilitates
the server or client to know about the camera’s network status.
25
4.3.2 FTP Settings
Figure 4-11 FTP Settings
V6202IR-TA/TX series camera has the function of alarm associated with FTP
upload (alarm triggered image snapshot). Configure server IP, user name and
password in the FTP settings and activate FTP handling way in alarm settings,
then alarm triggered images FTP upload can be achieved.
4.3.3 SMTP Settings
Figure 4-12 SMTP Settings
User needs to set mail server, recipient, etc in SMTP settings interface.
Server IP: Set mail server address. From: Set sender’s mail address. To: Mail address of recipient. CC: Mail address of the person copy to.
26
Authentication: Enable or disable authentication function. This function
should be set according to authentication requirements of mail server.
User name: Sender’s name, it can be set according user’s needs. Password: Set sender’s password.
Note: there is no limit for Sender’s name and password settings.
After setting, click “Set” Save to take effect.
If user selects “mail” in “Alarm Settings” interface, system will send mails
according to SMTP settings.
4.3.4 HTTPS Settings
Figure 4-13 HTTPS Settings
V6202IR-TA/TX series camera supports HTTPS protocol. You can import the
CA certificate in the interface.
4.3.5 802.1X Settings
Figure 4-14 802.1X Settings
27
V6202IR-TA/TX series camera supports 802.1X protocol. You have to enable
802.1X authentication when needed. Then, select an EAP method and enter the
user name and password.
4.3.6 QOS Settings
Figure 4-15 QOS Settings
There are 4 network Qos modes to be selected:
(1) Normal Service
(2) Max Reliability
(3) Max Throughput
(4) Min Delay
Recommend: Normal Service.
4.3.7 IGMP Settings
Figure 4-16 IGMP Settings
V6202IR-TA/TX series camera supports multicast function. In the IGMP
interface, users can select the stream type and set the state, multicast IP address
28
and RTP port.
4.3.8 SIP Settings
Figure 4-17 SIP Settings
SIP Server: to configure SIP server for device;
SIP Server IP: the IP address of SIP server;
Port: the port number of SIP server;
Server ID: the ID of SIP server;
Device ID: the device ID used for registration with SIP server;
Alarm ID: the ID registered for device alarm;
Register Interval: the interval for re-registration of device in seconds;
Heat Beat Interval: the interval to send heat beat information by the device in
seconds;
After configuration completed, click Save and the device sends a registration
29
request to the server.
Position Information: the mounting information or instruction for device.
Longitude: the longitude of mounting position, as precise to two places of
decimal;
Latitude: the latitude of mounting position, as precise to two places of decimal.
4.3.9 MDA Settings
Figure 4-18 MDA Settings
In MDA settings interface, you can set the Sever which the motion detection
alarm uploads to.
State: disable or enable motion detection alarm upload. When it’s on, you can set
camera name, user name, password, server IP and Port number. After setting
completed, click “Save” button to take effect.
30
4.3.10 DDNS Settings
Figure 4-19 DDNS Settings
Dynamic Domain Name System (DDNS) synchronizes the host name and
dynamic IP address continuously. Users don’t have to memorize the dynamic
IP address, but enter the dynamic domain name to connect the IP camera.
DDNS needs a PC with fixed IP address on the Internet to run the dynamic
domain name server.
Operation: select DDNS type in Enable option, enter the IP address of the
DDNS server into the address bar, and configure domain name, user name,
password, and update time and then save the settings. Open the IE browser, and
enter the domain name to go to the query page of the device.
4.3.11 UPnP Settings
Create mapping between private network and the Internet via UPNP protocol.
Select UpnP option and enter the configuration page. The added mapping list
appears on the page.
31
Figure 4-20 UPnP Settings
In “Operation” column,
means to delete; means to edit user
information.
Click Add button to add the mapping.
Figure 4-21
32
4.4 Camera Settings
For
V6202IR-TA series, click “Camera” in the navigation bar to enter the interface
shown as below:
Figure 4-22 Basic Settings
4.4.1 Basic Settings
You can set the following parameters:
Flicker frequency: 50Hz or 60Hz.
CVBS: it automatically changes with the flicker frequency. (Note: analog video
is closed after MJPEG stream is enabled. To enable analog video, please close
MJPEG stream.)
33
Enable or disable backlight compensation or digital WDR.
Contrast Enhance: 1~6 levels match with 6 kinds of Gamma curve separately. If
it is set to Auto, the system will adjust automatically.
4.4.2 Exposure Settings
Figure 4-23 Exposure Settings
Exposure set, auto aperture, scene, AGC, shutter speed and manual AGC can
also be set in this interface.
Exposure Set: Manual, Scene and Shutter Priority available. In Scene mode,
indoor or outdoor can be selected and AGC can be set (maximum 64X); if set to
Manual mode, shutter speed can be set from
1/25s to 1/8000s and manual AGC
can be set to
1X to 64X, yet the scene and AGC are nonadjustable; if set to
34
Shutter Priority mode, the shutter speed and AGC can be set.
Auto aperture: to enable or disable auto iris.
AE target: set AE target level. It can adjust video brightness via AE target setup.
4.4. 3 Effect Settings
In the Effect Settings interface, users can adjust the brightness, sharpness, hue,
contrast; saturation and 3D denoise in two ways: General or Mode, as shown in
the figure below:
Figure 4-24 Effect Set - General
Drag the slider to adjust the brightness, sharpness, hue, contrast, saturation and
3D denoise.
35
Figure 4-25 Effect Set - Mode
The camera supports 6 video effect modes. Users can set and save Name, IR
mode and Scene parameters for each mode. Click “Factoryset” to restore it to
default settings.
The camera provides 7 Scene modes:
Normal, Anti Fog, Motion, Entrance,
Natrium, Sharpen, USrMode. Each mode matches with a group of parameters, such
as
brightness, sharpness, hue, contrast, saturation and 3D denoise.
In the Mode call, users can set effect mode call status and call period.
36
4.4. 4 White Balance Settings
Figure 4-26 White Balance Settings
The camera has rich white balance modes, including Auto, Manual,
Incandescent light, Cool white fluorescent light, Sun light, Cloudy and Natrium
light. If set to manual mode, you can set the red gain and blue gain.
37
4.4. 5 Focus Settings
Figure 4-27 Focus Settings
V6202IR-TA/TX series IP camera is built-in motorized zoom lens for remote
focal length adjustment. Click “Focus” in camera settings interface to enter
focus settings.
In this page, you can select focus mode, zoom/focus and call focus limit.
Auto focus:
In auto focus mode, the interface is shown as above figure.
Click
button to focus wide; click button to focus tele. In this process,
the interface is shown as figure below.
38
Figure 4-28
After focus finished, it will return to the interface as shown in Figure 4-23.
The focus time will be different as the lens original positions are different.
Focus process lasts 15s at most.
You can stop focus by clicking Stop button during focusing.
Left-click one section, the frame of this section will turn to green and the
camera will automatically focus for this area, shown as below:
39
Figure 4-29
Manual focus: click Manual focus to enter the interface as below.
40
Figure 4-30
Click
to focus wide/zoom tele.
Click
to focus near/focus far.
Focus Limit: the camera can call focus limit. There are 5 options: Near, Middle,
Far, User set 1, User set 2. The effects for Near, Middle and Far are default; but
User set 1 and User set 2 can be specified by users.
Reset: if the camera cannot focus clear by auto focus, click Reset button to
restart the motor.
41
4.4. 6 IR Settings
Figure 4-31
IR mode: set IR illuminators working mode.
Options: Off, On, Auto (turn on or off as per ambient light).
Switch time: in auto mode, the response time for day/night switch. Power set: the adjusting mode of illuminators’ power consumption.
Options: Auto, Manual. In auto mode, adjust illuminators’ brightness as per
ambient light. In manual mode, adjust the brightness by moving the slider in the
page. Rectify focus: if select it, camera will focus automatically when the video
switches between color mode and B/W mode.
4.4. 7 Heater Settings
Note: heater setting is available only for V6202IR-TX series camera. The
built-in heater can be turned on or off via Web page.
42
Figure 4-32
Heat Mode: set heater working mode.
Options: Off, On, Auto (turn on or off as per ambient temperature).
4.4. 8 Reset
In the interface, you can restore all the Camera Settings parameters to the
factory default settings.
4.5 Audio & Video Settings
Click the button Audio & Video in the navigation bar to display the following
interface.
43
Figure 4-33 Video Settings
Click the related option tab to enter the setting interface.
4.5.1 Video Settings
Users can set the video parameters in the format of H.264 major or minor
stream and MJPEG stream, such as resolution, frame rate and IP rate.
Resolution:
For H.264 major stream, the resolution comes up to 1920×1080, with
1280×1024, 1280×960, 1280×720, 1024×768, 800×600 optional.
For H.264 minor stream, resolution comes to 720×576, 720×480, 640×480,
352×288, 352×240 and closed.
For MJPEG stream, resolution comes to 1920×1080, 1280×1024, 1280×720,
720×480 and closed
44
Frame Rate: the number of compressed frames produced by camera per
second.
The bigger the frame is, the better the image continuity will be, but the CPU
performance is lowered.
The smaller the frame is, the worse the image continuity will be, but the CPU
could handle more events.
The maximum frame rate for H.264 is 30fps. The maximum frame rate for
MJPEG is 10fps.
Note: the video settings of H.264 major/minor stream are linkage with that of
MJPEG stream. If H.264 major stream is set to 1080P/30fps, minor stream
closed, MJPEG is only able to set to1080P/4fps. If H.264 major stream is set to
1080P/25fps, minor stream closed, MJPEG frame is able to set to 10fps. Do
operate according to the prompt on the page.
GOV number: GOV number means the ratio of I frame to P frame in
compressed video images.
The bigger the value is, the less the data quantity is and the less network
resource occupancy.
Max. GOV number can be set to 60.
Bit Rate: There are 2 modes: variable rate (vbr) and constant rate (cbr).
The variable rate can adjust the bandwidth that it occupies automatically
according to the complexity of image, because the complexity of real video
sequence keeps changing, details, speed, etc, and the variable rate setting mode
can be used to choose how much bandwidth should be used. If the video gets
more details and moving fast, then it takes up more bandwidth to transmit, and
reversely it occupies less bandwidth. When the setting goes with constant bit
rate, then the image is transmitted under a constant bandwidth.
Bit Rate Upper Limit: You have to set the upper limit of bit rate if “vbr” is
45
selected; the stream size will be fixed if “cbr” is selected and the stream size is
defined in the “Bit Rate Upper Limit”. For major stream, the bit rate upper limit
can be 1000kbps~10000kbps; for minor stream, the bit rate upper limit can be
256Kbps~ 2000Kbps.
Image Quality: it can be set under MJPEG stream. Options: Highest, High,
Average, Low and Lowest. The higher the image quality is, the more bandwidth
it will occupy.
4.5.2 OSD
Figure 4-34 OSD Mode 1
OSD settings include: Text OSD and Date OSD.
The camera supports two OSD modes: Mode 1, Mode 2. You can switch the
mode only if Text 2 is on.
Only if Text 1, Text 2 and Date OSD are set to “On”, you can set the text
46
content and the display position of text and date.
Context: Enter the text content in the box of Context, which allows up to 40
characters (lower/upper case letters and
0~9).
X-axis &Y-axis: The title axis location. Both X-axis and Y-axis can be any of
whole numbers from 0 to 99.
Font Size: Set the font size to be displayed. The bigger the value is, the larger
the font size is. Default as: 3. After all settings finished, clickSave” button to display OSD on the video. To cancel OSD, set it to “Off” and then click the button “Save”.
See the figure for OSD Mode 2:
Figure 4-35 OSD Mode 2
Only if Text 1, Text 2 and Date OSD are set to “On”, you can set the text
content and the display position of text and date.
Context: Enter the text content in the box of Context. Text 2 supports five-row
display and each row allows up to 40 characters (lower/upper case letters and
0~9).
X-axis &Y-axis: The title axis location. Both X-axis and Y-axis can be any of
whole numbers from 0 to 99.
Font Size: Set the font size to be displayed. The bigger the value is, the larger
47
the font size is. Default as: 3. After all settings finished, clickSave” button to display OSD on the video. To cancel OSD, set it to “Off” and then click the button “Save”.
4.5.3 Privacy Mask
V6202IR-TA/TX series camera supports 4 privacy masks. If there is certain
location within the surveillance area where operators are not allowed to see, and
thus, Privacy Mask can be applied. System covers and shields the sensitive area
via Privacy Mask setting, to avoid operators observing certain sensitive
locations on monitor.
Note: do turn on privacy mask function in Live View interface before privacy mask setting (see Section 4.1).
Figure 4-36 Privacy Mask Settings
How to set the privacy masks:
48
Tick the box of motion detection area number. Click the button “Draw” with
the mouse, press the left mouse button and drag on the video till a blue frame
displays on the screen. Then, click the button “Save” with the left mouse
button and the blue frame changes into black which indicates a successful
setting.
To cancel a privacy mask, just cancel the box ticking.
4.5. 4 Motion Detection
Figure 4-37 Motion Detection Settings
V6202IR-TA/TX series camera support motion detection. Users can easily set
the motion detection areas (up to 4) with the mouse.
Note: do turn on motion detection function i n Live View interface befo re motion detection setting.
49
Tick the box of Zone number to be set. If the motion detection area has been
set, a blue frame will be displayed on the screen.
How to set the motion detection area:
Tick the box of motion detection area number. Click the button “Draw” with
the mouse, and press the left mouse button and drag on the video till a blue
frame displays on the screen. Then, click the button “Save” with the left
mouse button and the blue frame changes into green which indicates a
successful setting.
Besides, you can set the area name and sensitivity.
To cancel a motion detection area, just cancel the box ticking.
4.5.5 Shelter Alarm
Figure 4-38
V6202IR-TA/TX series camera supports shelter alarm function. Users can
easily set the shelter alarm areas with the mouse.
50
At first, enable shelter alarm. Click the button “Draw” with the mouse, press
the left mouse button and drag on the video till a blue frame displays on the
screen. Then, click the button “Save” with the left mouse button and the blue
frame changes into green which indicates a successful setting.
Besides, you can set the area name and sensitivity.
It will trigger alarm when the video within the area is shielded. Refer to
Section 4.6 for alarm contact details.
4.5.6 Link Configure
Figure 4-39
For each stream, the total of 90 port and RTSP port is 5. In this interface, you
can set the video numbers of 90 port and RTSP port.
The default setting is visit 2-ch major stream, 2-ch minor stream and 2-ch
MJPEG video via 90 port and visit 3-ch major stream, 3-ch minor stream and
3-ch MJPEG video via RTSP port.
4.5. 7 Storage Path
You can set the photo saving path and recording saving path in the following
interface.
Figure 4-40 Storage Path
51
Default photo saving path:
C:\InfiPlayerAX\Picture.
Default video saving path: C:\InfiPlayerAX\ Video.
Photo and video formats can also be set. The default photo format is .jpg and the
default video
format is .avi.
To change the saving path, click the button “Browse” and select the path from
the popup dialog box.
4.5. 8 Audio Settings
Figure 4-41 Audio Settings
Sample Rate: 8K.
Format: G.711-U.
4.6 Alarm Settings
Click “Alarm” in the navigation bar to display the following Alarm Settings
interface:
52
Figure 4-42 Alarm Settings
Alarm configuration
I/O In 1, I/O In 2: Settable 2-channel alarm inputs.
Each alarm input has 2 modes: Grounded Circuit or Open Circuit.
Alarm out contact: used to set sending way of alarm.
Local Contact: I/O out is triggered by I/O alarm in, motion detection alarm,
shelter alarm, SD card out, network link down or IP address conflict. Default:
Local Contact.
Net Contact: I/O out is controlled by the surveillance management software. Note: This function needs to be supported by digital video surveillance
management software like V2216. If Net Contact is selected, users have to set
53
Alarm Server IP the same as the IP address of V2216-CMS server. After
related setting to V2216 finished, users can remotely control the relay via
V2216 software. For detailed information, please refer to V2216 manual.
Alarm Server IP: used to set the IP address of alarm server. If alarm occurs, it
will inform the alarm server.
Alarm out contact
Users can set the relevant alarm response ways for I/O alarm in, motion
detection alarm, shelter alarm, SD card out, network link down or IP address
conflict. Options: Alarm out 1 (if Net Contact is selected, Alarm output 1 on the
web page is unavailable), SD card, Mail, FTP and Audio. After setting
completed, click “Save” button to take effect.
Note: when “FTP” or “Mail” is selected, you need to set FTP or SMTP
parameters in Network Settings, refer to Section 4.3.2 or Section 4.3.3 for
details.
Alarm schedule
V6202IR-TA/TX series camera can set the effective alarm schedule. Select the
alarm period (if Sunday is selected, alarm will be enabled during the set period
of each Sunday; if “everyday” is selected, alarm will be enabled during the set
period of everyday), and then, set the time period. Enter the start time and end
time in the 24-hour format. The end time must be larger than the start time.
4.7 Record Management
Click “Record” in the navigation bar to display the following settings interface:
54
Figure 4-43
In the record interface, you can configure settings and replay.
4.7.1 Record Settings
Recording video type: Select the type of videos to record, major stream or
minor stream. SD card when full: Overwrite or Stop. Overwrite means newly recorded
videos automatically overwrite the previous videos when the SD card is full;
Stop means recording stops when the SD card is full. Recording mode: Alarm triggered, Always, Close. If Alarm Triggered is
selected, also with SD card selected under alarm out contact in the alarm
interface (refer to 4.6), recording is automatically triggered when alarm occurs.
You can view the total space, used space and state of SD card and also format
it.
To remove SD Card when it is being used, please click “Reject”
.
55
4.7.2 Replay
Figure 4-44 Replay
Video Search: set the start and end time, and then click the search button. All
videos recorded during this period of time will display in the list.
56
Figure 4-45 Searching Videos
Replay: to replay a video, double click a file in the list with the mouse or select
a file and then press the “Play” button
. During playing, click or to
pause or stop playing.
Click the button
on the right of video window, the right window will
disappear, show as below:
57
Figure 4-46
Click the button
, the interface will restore.
Download: You can download the videos stored in the SD card to your PC. Select the
file from the video list (also you can select multiple files simultaneously using the
key “Ctrl” or “Shift”), and then click the button “Download” to enter the
downloading interface.
Figure 4-47 Downloading Videos
58
Save to: Set the path to save the downloaded files. If resetting required, click the
button “Browse”.
AVI/H.264 drop-down list box: select the downloaded file attribute.
In the download list, file total size, status and process will display.
Click the button “Start”, and then the files in the list will be downloaded in order.
The process shows 100% after downloading is finished.
Click the button “Open” to enter download content.
4.8 Account Settings
The default super user is admin (password: admin). Super user can add, delete
common user, and change the password of common users. Super user cannot
change his password. A maximum of 7 common users are supported.
Detailed instruction about how to add and delete user are addressed below.
Click the Account option tab in the Settings interface, the following account
information will display. The “Num” item shows the current user number. In
“Property” column,
stands for super user; stands for common user. In
“Operation” column,
means to delete; means to edit user information.
See figure below:
Figure 4-48 Account Settings
1. Add Users
(1)
Click “ ”, enter the interface of “Add a User”.
59
Figure 4-49 Add a User
(2) Enter the desired User Name and Password (Note: User name and password
shall include letter, number and underline only. No special character is allowed.
The string length of user name is legal between 1 and 30 characters and that of
password is between 5 and 20 characters.)
(3) Click “OK” button. If the setting is successful, the new user name will
appear in the account list. Take new user “user1” as an example:
Figure 4-50
2. Delete Users
In the “Account setting” interface, click button of the “Operation” item to
delete user. The following dialog box will display:
Figure 4-51
60
Click “OK” button, the selected user would be deleted and the account list
would be automatically updated.
3. User Password Change
Click
button in the account list, the dialog box of Edit User Information
will pop up:
Figure 4-52
Input the old password, enter the desired new password for twice and then click
“OK” button, the following picture will appear:
Figure 4-53
4.9 System Log
Click the “Log” option tab, the date, time and log information will appear on
the right of the screen.
61
Figure 4-54
It can display 30 logs on a page. The user can turn over the pages or skip to the
desired page by clicking the below arrows. Click “Delete logs”, a prompt will
come out. Then, click “Yes” to clear logs.
62
APPENDIX I MAGNETIC RING FILTER INSTRUCTION
To reduce electromagnetic interference that power supply generates, it is necessary to install a magnetic ring filter with the power cable of Infinova front-end IP device.
To install a magnetic ring filter with power supply: Step 1: Open the magnetic ring filter and lead the power cable through.
Step 2: Wire the power cable on the magnetic ring filter 3 rounds or more
(Make sure the filter can be well closed).
Step 3: Close the magnetic ring filter. Notice: The magnetic ring filter should be installed no more than 50 mm
away from the power output connector. As shown in Figure 3, the cable length from A to B should be 50mm at most.
Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter
Figure 3 Power cable with magnetic ring filter
63
APPENDIX II QUESTIONS & SOLUTIONS
The following table describes the symptoms causes and solutions for the problems.
Symptoms Possible Causes Solutions
The network camera does not perform initiation after power-on
Wrong power connection Reconnect power cable
Power supply failure
Repair or replace power supply
PCB fuse damage Replace the fuse
Immediate startup after power-off
Restart 10 seconds later after power-off
If PoE power supply is used, too long transmission distance may make the power of the Power Supply Switcher insufficient.
Shorten the length of the power supply network cable, or replace Power Supply Switcher of larger power
If PoE power supply is used, connection to other electric appliance make the ground level not in the correct level.
Disconnect other electrical appliance.
No video signal displayed
The plug-in for viewing image is installed incorrectly.
Refer to the Plug-in Installation to reinstall it.
Network camera’s IP address conflicts with other user’s IP address
Set the unique IP address
Vague image Manual focus is not precise
Manually adjust the camera focus carefully.
64
APPENDIX III CABLE DIAMETER CALCULATION AND LIGHTNING & SURGE PROTECTION
Relation between 24VAC Cable Diameter and Transmission Distance
In general, the maximum allowable voltage loss rate is 10% for AC-po wered devices. The table below
shows the relationship between transm ission power and maximum transmission d istance under a certain
specified cable diameter, on condition that the 24VAC voltage loss rate is below 10%. According to the
table, if a device rated at 50W is instal led 17-meter away from the transf ormer, the minimum cable
diameter shall be 0.8000mm. A lower diameter value tends to cause voltage loss and even system
instability.
0.8000 1.000 1.250 2.000
10 283 (86) 451 (137) 716 (218) 1811 (551)
20 141 (42) 225 (68) 358 (109) 905 (275)
30 94 (28) 150 (45) 238 (72) 603 (183)
40 70 (21) 112 ( 34) 179 (54) 452 (137)
50 56 (17) 90 (27) 143 (43) 362 (110)
60 47 (14) 75 (22) 119 (36) 301 (91)
70 40 (12) 64 (19) 102 (31) 258 (78)
80 35 (10) 56 (17) 89 (27) 226 (68)
90 31 (9) 50 (15) 79 (24) 201 (61)
100 28 (8) 45 (13) 71 (21) 181 (55)
110 25 (7) 41 (12) 65 (19) 164 (49)
120 23 (7) 37 (11) 59 (17) 150 (45)
130 21 (6) 34 (10) 55 (16) 139 (42)
140 20 (6) 32 (9) 51 (15) 129 (39)
150 18 (5) 30 (9) 47 (14) 120 (36)
160 17 (5) 28 (8) 44 (13) 113 (34)
170 16 (4) 26 (7) 42 (12) 106 (32)
180 15 (4) 25 (7) 39 (11) 100 (30)
190 14 (4) 23 (7) 37 (11) 95 (28)
200 14 (4) 22 (6) 35 (10) 90 (27)
Power (W)
Diameter (mm)
Distance (ft / m)
65
Lightning & Surge Protection
The product adopts multi-level anti-lightning and anti-surge technology integrated with gas discharge tube,
power resistor and TVS tube. The powerful lightning and surge protection barrier effectively avoids
product damage caused by various pulse signals with power below 4kV, including instantaneous lightning,
surge and static. However, for complicated outdoor environment, refer to instruction below for lightning
and surge protection:
The product features with dedicated earth wire, which must be firmly grounded. As for surveillance
sites beyond the effective protectio n scope, it’s necessary to erect independent li ghtening rods to
protect the security devices. It’s recommended to separate the lightning rod from the mounting pole,
placing the rod on an independent pole, as shown in the figure below. If the product has to be installed
on the same pole or pedestal for lightning rod, there should be strict insulation between the video cable
BNC terminal, power cable, control cab le and the standing pole of the lightning rod.
For suburb and rural areas, it’s recommended to adop t direct burial for the transmission cables .
Overhead wiring is prohibited, bec ause it’s more likely to encounter lightning str ike. Use shielded
cables or thread the cables through metal tubes f or burial, thus to ensure the electric con nection to the
metal tube. In case it’s difficult to thread th e cable through the tube all th e way, it’s acceptable to use
tube-threaded cables only at both ends of the transmission line, yet the length in burial should be no
less than 15 meters. The cable sheath and the tube should be connected to the lightning -proof
grounding device.
Additional high-power lightning-proof equipment and lightning rods should be installed for strong
thunderstorm or high induced voltage areas (such as high-voltage substation).
The lightning protection and grounding for outdoor devices and wires should be designed in line with
the actual protection requirement, national standards and industrial standards.
The system should perform equipotential grounding by streaming, shielding, clamping and earthing.
The grounding device must meet anti-interference and electric safety requirements. There should be no
short-circuiting or hybrid junction be tween the device and the strong grid. Mak e sure there’s a reliable
grounding system, with grounding resistance below 4 (below 10 for high soil resistivity regions). The cross-sectional area of the earth ing conductor should be no less than 2 5mm².
Lightning rod
Front device for surveillance system
Separated layout for the lightning
rod and the standing pole
LPZO
B
LPZO
A
Mounting
pole for
front device
30° 30°
Infinova
51 Stouts Lan e, Monmouth Junction, NJ 08852, U.S.A. Tel: 1-888-685-2002 (USA only)
1-732-355-9100 Fax: 1-732-355-9101 sales@infinova.com
V1.5 1411