This manual may not be reproduced in any form or by any means to create any
derivative such as translation, transformation, or adaptation without the prior
written permission of Infinova.
Infinova reserves the right to change this manual and the specifications without
prior notice. The most recent product specifications and user documentation for
all Infinova products are available on our web site www.infinova.com.
Trademarks
Infinova
®
is a trademark of Infinova.
All other trademarks that may appear belong to their respective proprietors.
FCC Warning
The V6202IR-H0 series HD megapixel IR IP fixed cameras comply with the
FCC rules.
Operation is subject to the following two conditions:
This device will not cause harmful interference.
This device must accept any interference received, including interference
that may cause undesired operations.
V6202IR-H0 series HD 1MP and 1.3MP IR IP fixed cameras have been
The
tested and found to comply with the limits for a Class A digital device, pursuant
to the FCC rules. With these rules and regulations being obeyed to maintain the
good working condition of device, the operation is not supposed to be affected
by the external interruptions under certain circumstances. This device is
electromagnetic, so all the installation and application processing along the
device has to follow strictly to the manual, or it may hamper the
telecommunication around. Meanwhile, there is no guarantee that interference
will not occur in a certain particular installation situation.
Read this manual carefully before installation. This manual
should be saved for future use.
Important Safety Instructions and Warnings:
Electronic devices must be kept away from water, fire or high magnetic
radiation.
Clean with a dry cloth.
Provide adequate ventilation.
Unplug the power supply when the device is not to be used for an extended
period of time.
Only use components and parts recommended by manufacturer.
Position power source and related wires to assure to be kept away from
ground and entrance.
Refer to qualified personnel for all service matters.
Save product packaging to ensure availability of proper shipping containers
for future transportation.
Indicate that the un-insulated components within the product may carry a
voltage harmful to humans.
Indicate operations that should be conducted in strict compliance with
instructions and guidelines contained in this manual.
Warning: To avoid risk of fire and electric shock, keep the product away
from rain and moisture!
Unit Weight 1.37lbs. (0.62kg)
Shipping Weight 1.87lbs. (0.85kg)
1.6 Notice
1. Firstly perform network settings after login. The gateway IP address should
be set as that of the connected to the network camera.
2. The IP address is not allowed to conflict with that of other devices; otherwise,
you cannot visit the camera.
5
CHAPTER II INSTALLATION
2.1 Installation Precautions
Do not drop the camera or subject it to strong knock.
Do not point the camera lens toward the sun or other strong light.
Do not install the camera in environment with temperature beyond the
acceptable range (from -20°C to 60°C), or with high humidity, direct
rainfall, frequent vibrations and shocks.
Make sure to choose the suitable position that can support the weight of the
camera and the bracket in years and fix them properly.
Exercise maximum caution when installing the unit to the wall or ceiling.
You should not engage in the installation work yourself. Ask a professional
to do the job, since the fall of the unit can result in injuries and accidents.
As a failsafe against falling, attach the unit by chain, wire cable or other
safety restraint to an appropriate anchor point.
Open the back panel to insert TF card should be performed in a dry
environment. To prevent the camera module moistened and dusted, cover
with the back panel quickly after TF card is installed.
Do not open the front panel to adjust the built-in fixed lens.
2.2 Installation Introduction
There are two camera-mounting holes at the bottom of the camera.
See the figure below: (Unit: mm)
6
Use 1/4-20UNC screws to mount the camera to the suitable bracket.
Note: Infinova’s V1554-6 bracket is recommended to match with V6202IR-H0
series camera. But V1554-6 bracket is not the official accessory. Please order it
if you need.
See the figure below for the dimensions of V1554-6: (Unit: mm)
Figure 2-1
7
Figure 2-2
The bracket provides 360° horizontal adjustment and 0~80° vertical adjustment.
Please adjust the camera angle according to your surveillance need.
8
Dimensions (Unit: inc h, in t he parentheses is mm)
Figure 2-3
CHAPTER III IE BROWSER SETTINGS
When view the video, the user need to adjust the IE browser of the monitor or
other video devices, and set proper system function based on the following
instructions:
Support IE browser version: Internet Explorer 6.0 or above;
Must install InfiPlayerAX control and equip with Directx 9.0c.
3.1 Equipment Connection
V6202IR-H0 series IP camera can be directly connected to a computer, or
connected to a network.
Note: Check whether the connection is tight or not before power-on.
3.2 Software Installation
The installation procedures of V6202IR-H0 series camera image software are
listed as follows:
(1) Login
First, start IE browser and enter IP address. Enter user name and password in
the pop-up login interface.
The default IP address is http://192.168.1.100; the default subnet mask is
255.255.255.0 and the default gateway IP address is 192.168.1.254. For normal
access, correctly set local IP parameters before system login.
Do log in the system with the default super user for the first time to run the
software. The default Super User is admin (password: admin).
Note: Do change the password in time to secure your system.
(2) Install and run Control
After a successful login, the prompt of security warning will pop up to remind
the user to install
InfiPlayerAX control. Click “Install”.
9
Figure 3-1
After InfiPlayerAX control is installed, you can view the live video.
10
Note:
If InfiPlayerAX control installation falls, the live video won’t display. Then,
you should change the IE security level.
1. Select “Tool” in the menu bar, and then select “Internet Options” from the
drop-down menu.
2. Select “Security” in the pop-up Internet options.
3. Click “Internet” icon and then click “Custom Level”.
4. Select “Enable” or “Prompt” in the options of “Download unsigned ActiveX
controls”.
5. Click Privacy in the “Internet”, clear “Block pop-ups”, then redraw the
screen and install control as per the prompt. The live video will display.
By now, the IE browser setting for image view comes to an end.
Figure 3-2
11
12
CHAPTER IV BASIC FUNCTION OPERATION
This chapter mainly introduces the settings and operation of V6202IR-H0
series.
4.1 Live View
Start IE browser after the server is powered on for about 90 seconds, and then
enter IP address, such as http://192.168.1.100 (default), in the address field.
Note: The default subnet mask is 255.255.255.0 and the default gateway IP
address is 192.168.1.254. For normal access, please correctly set local IP
parameters before system login.
The login interface is displayed as shown in figure below in English operating
system.
Figure 4-1 User Login
Do log in the system with the default super user for the first time to run the
software. The default Super User is admin (password: admin). Input the correct
user name and password and then click “OK” button to log.
After login is successful, the following interface will display:
Figure 4-2
H.264 Live view
V6202IR-H0 series IP camera supports H.264 and M-JPEG video
compression formats. After successful login, it enters H.264 major stream live
video interface. Users can also select H.264 minor stream or MJPEG from the
drop-down list of stream type. In the H.264 major or minor stream type, users
can do recording, snap shooting, motion detection and privacy mask settings.
Over browsing videos, users can also select a proper video scale.
Play mode: live or fluid for option.
Click the button
C:\InfiPlayerAX\Picture.
to snapshoot and to enter the storage path. Default:
V6202IR-H0 series supports local recording. Click the recording button
to start recording; when the button changes to
, click it to stop recording.
During local recording, “REC” appears on the video screen. Click the button
13
to enter the recording storage path. Default: C:\InfiPlayerAX\ Video.
Users can set the snap shooting and recording storage path in the video
settings interface.
Indicate that the motion detection and privacy mask functions are
disabled. Click the buttons to enable them and then the buttons will be shown
as
.
Note: only when motion detection or privacy mask is enabled, you can set the
corresponding function in Video Settings, refer to Section 4.5.3 or 4.5.4 for
details.
Note: the login web page language should be set to the same as that of PC’s
operating system.
Click the option tab “Setting” to enter the system setting interface.
14
White Balance, IR set, Reset), Video Settings, Alarm Settings, Account Settings
(Add/Delete User, Change Password), Log, etc.
Note: The following instructions are used for the super user.
4.2 System
Click the navigation bar “System” and it displays the following three option
tabs: System, Time and Advanced, as shown in Figure 4-3.
4.2.1 System Information
The initial interface of System Settings displays related system information,
such as basic system information, network settings, NTP settings, alarm settings,
H.264/MJPEG video settings, etc.
4.2.2 Time Settings
Figure 4-3 Settings Interface
With the help of navigation menu on the left, Super user can perform the
following operations: Basic Information View, Time Settings and Advanced
Settings, Network Settings, Camera Settings (including Basic Set, Effect Set,
15
Figure 4-4 “Time” Settings
16
Time Zone Settin gs
Time Zone: Select the desired time zone in the scroll box, and then click “Save”
to save it.
There are 33 time zones for your selection.
If Daylight Saving Time is applied in your region, please enable daylight saving
time.
After settings completed, please click the button “Save”.
NTP Settings
Set the NTP server’s IP address, synchronization interval, etc.
After completed, please click the button “Save”.
Sync now
There are two sync modes: local sync and NTP sync.
Local Sync means the system time is consistent with that of local PC. In the
NTP Sync mode, the system will automatically adjust time to the same as that
of NTP Server.
4.2.3 Advanced Settings
Figure 4-5 “Advanced” Settings
Software Update
Free software update is provided for V6202IR-H0 series camera, and this
update service can reduce system maintenance budget.
Confirm the requirement submitted by user, we will provide the latest software
for download, and help user to update the V6202IR-H0 series camera.
Follow the steps below to update software:
Click “Browse” button on the interface and the file selection dialog box will
pop up.
Figure 4-6
Select update file, and press “Open” button. The selected update file will be
displayed in the box before “Browse”.
After that, click “Submit” button to update software, the following information
will appear:
17
Figure 4-7
Click “Yes” button, run the program to finish the update.
The response time is due to the program type. You may wait a long time for
some program. Do not power off during the update process. Power-off will
make update fail, even damage the original program or unable to update again.
After update successfully, it needs to reboot the system. There is time prompt in
the web page during reboot. After reboot, it will skip to new web page to run
new program.
Note: Available only for the super user.
Factory Settings
V6202IR-H0 series camera provides online reset function, which greatly
facilitates reset adjustment.
Select “Keep current IP unchanged”, click “Reset” button and the system will
pop up a message as below:
18
If “Keep current IP unchanged” is unselected, the IP address will be reset to the
factory default settings.
There is time prompt in the web page during reset. After reset, it will skip to
new web page.
If current IP unchanged, you can access web page directly. If IP address resets
to
192.168.1.100, you can’t access web page. Then, you have to set PC’s IP address
to 192.168.1 section, such as 192.168.1.25. After that, access web page
IP address and save, PC’s IP address will restore to the corresponding
camera’s
section.
to change
Note:
1. To avoid error happens, the operation of online reset function should be
performed under qualified personnel’s guide.
2. Default IP address is 192.168.1.100, and default subnet mask is
255.255.255.0.
3. Do not power off during reset, or else the reset will fail.
Online Reboot
Click “Reboot” button, the dialog box “This operation will take 90 seconds, are
you sure to continue?”pop up. Click “OK” and the system will restart. There is
time prompt in the web page during reboot. After reboot, it will skip to new
web page.
Note: Available only for the super user.
Figure 4-8
Click “OK”, all the parameters (excluding IP address) will be reset to the
factory default settings.
19
20
4.3 Network Settings
Click “Network” in the navigation bar, and the following interface will display:
Figure 4-9 Network Settings
8 options tabs are available: Network, FTP, SMTP, HTTPS,
and SIP.
4.3.1 Network Settings
In the Network Settings interface (as shown in the figure above), users can
enable or disable DHCP. When it is disabled, users can set Unit IP address,
Subnet mask, Gateway and DNS server IP address manually.
Users can also enable/disable PPPoE in this interface. If enabled, users can set
the user name and password.
V6202IR-H0 series camera supports heartbeat function. In SNMP settings, set
21
802.1X, QOS, IGMP
and save the heartbeat sever IP address and Heartbeat interval, and then the
heartbeat package will be sent to the server or client, which greatly facilitates
the server or client to know about the camera’s network status.
4.3.2 FTP Settings
Figure 4-10 FTP Settings
V6202IR-H0 series camera has the function of alarm associated with FTP
upload (alarm triggered image snapshot). Configure server IP, user name and
password in the FTP settings and activate FTP handling way in alarm settings,
then alarm triggered images FTP upload can be achieved.
4.3.3 SMTP Settings
Figure 4-11 SMTP Settings
User needs to set mail server, recipient, etc in SMTP settings interface.
22
Server IP: Set mail server address.
From: Set sender’s mail address.
To: Mail address of recipient.
CC: Mail address of the person copy to.
Authentication: Enable or disable authentication function. This function
should be set according to authentication requirements of mail server.
User name: Sender’s name, it can be set according user’s needs.
Password: Set sender’s password.
Note: there is no limit for Sender’s name and password settings.
After setting, click “Set” Save to take effect.
If user selects “mail” in “Alarm Settings” interface, system will send mails
according to SMTP settings.
4.3.4 HTTPS Settings
Figure 4-12 HTTPS Settings
V6202IR-H0 series camera supports HTTPS protocol. You can import the CA
certificate in the interface.
4.3.5 802.1X Settings
Figure 4-13 802.1X Settings
V6202IR-H0 series camera supports 802.1X protocol. You have to enable
802.1X authentication when needed. Then, select an EAP method and enter the
user name and password.
4.3.6 QOS Settings
Figure 4-14 QOS Settings
There are 4 network Qos modes to be selected:
(1) Normal Service
(2) Max Reliability
(3) Max Throughput
(4) Min Delay
Recommend: Normal Service.
23
24
4.3.7 IGMP Settings
Figure 4-15 IGMP Settings
V6202IR-H0 series camera supports multicast function. In the IGMP interface,
users can select the stream type and set the state, multicast IP address and RTP
port.
4.3.8 SIP Settings
SIP Server: to configure SIP server for device;
SIP Server IP: the IP address of SIP server;
Port: the port number of SIP server;
Server ID: the ID of SIP server;
Device ID: the device ID used for registration with SIP server;
Alarm ID: the ID registered for device alarm;
Register Interval: the interval for re-registration of device in seconds;
Heat Beat Interval: the interval to send heat beat information by the device in
seconds;
After configuration completed, click Save and the device sends a registration
request to the server.
Position Information: the mounting information or instruction for device.
Longitude: the longitude of mounting position, as precise to two places of
decimal;
Latitude: the latitude of mounting position, as precise to two places of decimal.
Figure 4-16 SIP Settings
25
4.4 Camera Settings
Click “Camera” in the navigation bar to enter the interface shown as below:
Figure 4-17 Basic Settings
4.4.1 Basic Settings
You can set the following parameters:
Flicker frequency: 50Hz or 60Hz.
CVBS: it automatically changes with the flicker frequency.
Enable or disable backlight compensation or digital WDR.
Exposure set, scene, AGC, auto aperture, shutter speed and manual AGC can
also be set in this interface.
Exposure Set: Manual, Scene and Shutter Priority available. In Scene mode,
indoor or outdoor can be selected and AGC can be set (maximum 64X); if set to
26
Manual mode, shutter speed can be set from
can be set to
Shutter Priority mode, the shutter speed and AGC can be set.
Auto aperture: to enable or disable auto iris.
Contrast Enhance: 1~6 levels match with 6 kinds of Gamma curve separately. If
it is set to Auto, the system will adjust automatically.
AE target: set AE target level. It can adjust video brightness via AE target setup.
4.4.2 Effect Settings
In the Effect Settings interface, users can adjust the brightness, sharpness, hue,
contrast, saturation and 3D denoise in two ways: General or Mode, as shown in
the figure below:
1X to 64X, yet the scene and AGC are nonadjustable; if set to
1/30s to 1/8000s and manual AGC
Figure 4-18 Effect Set - General
27
28
Drag the slider to adjust the brightness, sharpness, hue, contrast, saturation and
3D denoise.
Figure 4-19 Effect Set - Mode
The camera supports 6 video effect modes. Users can set name for each mode.
Each mode matches with a group of parameters, such as IR mode, brightness,
sharpness, hue, contrast, saturation and 3D denoise. Users can set and save
effect parameters for each mode. Click “Factoryset” to restore it to default
settings.
In the Mode call, users can set effect mode call status and call period.
4.4.3 White Balance Settings
Figure 4-20 White Balance Settings
The camera has rich white balance modes, including Auto, Manual,
Incandescent light, Cool white fluorescent light, Sun light, Cloudy and Natrium
light. If set to manual mode, you can set the red gain and blue gain.
29
4.4.4 IR Settings
Figure 4-21
IR mode: set IR illuminators working mode.
Options: Day, Night, Auto (turn on or off as per ambient light).
Switch time: in auto mode, the response time for day/night switch.
Power set: the adjusting mode of illuminators’ power consumption.
Options: Auto, Manual. In auto mode, adjust illuminators’ brightness as per
ambient light. In manual mode, adjust the brightness by moving the slider in the
page.
30
4.4.5 Reset
In the interface, you can restore all the Camera Settings parameters to the
factory default settings.
4.5 Video Settings
Click the button “Video” in the navigation bar to display the following
interface.
Figure 4-22 Video Settings
Video, OSD, Motion, Privacy, ROI, Shelter and Path can be set in this interface.
Click the related option tab to enter the setting interface.
4.5.1 Video
Users can set the video parameters in the format of H.264 major or minor
stream and MJPEG stream, such as resolution, frame rate and IP rate.
31
32
Resolution:
For H.264 major stream, the resolution of V6202IR-H01 series comes to
1280×960 and 1280×720; while the resolution of V6202IR-H00 series comes to
1280×720.
For H.264 minor stream, the resolution comes to 640×480, 320×240 and closed.
The resolution of MJPEG stream will be the same as that of major stream.
Frame Rate: the number of compressed frames produced by camera per
second.
The bigger the frame is, the better the image continuity will be, but the CPU
performance is lowered.
The smaller the frame is, the worse the image continuity will be, but the CPU
could handle more events.
The maximum frame rate for H.264 is 30fps. The maximum frame rate for
MJPEG is 5fps.
GOV number: GOV number means the ratio of I frame to P frame in
compressed video images.
The bigger the value is, the less the data quantity is and the less network
resource occupancy.
Max. GOV number can be set to 60.
Bit Rate Control: There are 2 modes: variable rate (vbr) and constant rate
(cbr).
The variable rate can adjust the bandwidth that it occupies automatically
according to the complexity of image, because the complexity of real video
sequence keeps changing, details, speed, etc, and the variable rate setting mode
can be used to choose how much bandwidth should be used. If the video gets
more details and moving fast, then it takes up more bandwidth to transmit, and
reversely it occupies less bandwidth. When the setting goes with constant bit
rate, then the image is transmitted under a constant bandwidth.
Bit Rate: You have to set the upper limit of bit rate if “vbr” is selected; the
stream size will be fixed if “cbr” is selected and the stream size is defined in the
“Bit Rate”. For major stream, the bit rate can be 256~10000kbps; for minor
stream, the bit rate can be 256~ 2000Kbps.
Image Quality: it can be set under MJPEG stream. Options: Highest, High,
Average, Low and Lowest. The higher the image quality is, the more bandwidth
it will occupy.
4.5.2 OSD
33
34
Set text display to “On” and you can set the text content and display position of
text and date OSD.
Context: 6 text OSDs are available. Enter the text content in the box of Context,
which allows up to 42 characters (lower/upper case letters and 0~9).
X-axis &Y-axis: the title axis location. Both X-axis and Y-axis can be any of
whole numbers from 0 to 99.
Font Size: set the font size to be displayed. The bigger the value is, the larger
the font size is.
Mode: OSD mode is optional with black and reverse. The OSD characters
feature with black fringe under black mode. While in reverse mode, the color of
OSD characters varies according to the background brightness. For example,
when the background is white, the OSD color will be black; and when the
background is black, the OSD color will be white.
After all settings finished, click “Save” button to display OSD on the video.
To cancel OSD display, set it to “OFF” and then click the button “Save”.
Figure 4-23
OSD settings include: Text OSD and Date OSD.
35
36
4.5.3 Motion Detection
s
Figure 4-24 Motion Detection Settings
V6202IR-H0 series camera support motion detection. Users can easily set the
motion detection areas (up to 4) with the mouse.
Note: do turn on motio n detectio n functi on in Live View interface be fore
motion detection setting.
Tick the box of Zone number to be set. If the motion detection area has been
set, a blue frame will be displayed on the screen.
How to set the motion detection area:
Tick the box of motion detection area number. Click the button “Draw” with
the mouse, and press the left mouse button and drag on the video till a blue
frame displays on the screen. Then, click the button “Save” with the left
mouse button and the blue frame changes into green which indicates
successful setting.
Besides, you can set the area name and sensitivity.
To cancel a motion detection area, just cancel the box ticking.
4.5.4 Privacy Mask
V6202IR-H0 series camera supports privacy mask function. If there is certain
location within the surveillance area where operators are not allowed to see, and
thus, Privacy Mask can be applied. System covers and shields the sensitive area
via Privacy Mask setting, to avoid operators observing certain sensitive
locations on monitor.
Note: do turn on privacy mask function in Live View interface before
privacy mask setting.
37
Figure 4-25 Privacy Mask Settings
How to set and cancel privacy mask is similar to the operations of motion
detection, refer to Section 4.5.3.
4.5.5 ROI
The camera supports four ROI encoding areas.
38
Figure 4-26 ROI Settings
ROI settings method:
Tick off the serial number of the region for setting and click the button “Drag
Box”. Then press the left button of the mouse on the video picture and drag it
until a blue-line box appears. Click the button”save” with the left button and
when the color of the regional border turns from blue into green, ROI settings
complete successfully
Cancel the tick-off of the serial number of the region, then ROI settings are
cancelled .
39
40
图 4-1 Region 1 settings
4.5.6 Active video tampering
The camera supports active video tampering.
图 4-2 Active video tampering settings
You can open or close this function on this page. When the function is open and
active video tampering is detected, the alarm lamp on the top of the page turns
red.
4.5.7 Storage Path
You can set the photo saving path and recording saving path in the following
Default video saving path: C:\InfiPlayerAX\ Video.
Photo and video formats can also be set. The default photo format is .jpg and
the default video format is .avi.
To change the saving path, click the button “Browse” and select the path from
the popup dialog box.
4.6 Alarm Settings
Click “Alarm” in the navigation bar to display the following Alarm Settings
interface:
42
43
Figure 4-30 Alarm Settings
Alarm configuration
Alarm Server IP: used to set the IP address of alarm server. If alarm occurs, it
will inform the alarm server.
Alarm out contact
Users can set the relevant alarm response way for motion detection alarm.
44
Options: Mail, FTP. After setting completed, click “Save” button to take effect.
Note: when “FTP” or “Mail” is selected, you need to set FTP or SMTP
parameters in Network Settings, refer to Section 4.3.2 or Section 4.3.3 for
details.
Alarm schedule
V6202IR-H0 series camera can set the effective alarm schedule. Select the
alarm period (if Sunday is selected, alarm will be enabled during the set period
of each Sunday; if “Everyday” is selected, alarm will be enabled during the set
period of everyday), and then, set the time period. Enter the start time and end
time in the 24-hour format. The end time must be larger than the start time.
4.7 Account Setting s
The default super user is admin (password: admin). Super user can add, delete
common user, and change the password of common users. Super user can
change his password. Do change Super user’s password in time to secure your
system.
A maximum of 7 common users are supported.
Detailed instruction about how to add and delete user are addressed below.
Click the Account option tab in the Settings interface, the following account
information will display. The “Num” item shows the current user number. In
“Property” column,
“Operation” column,
See figure below:
stands for super user; stands for common user. In
means to delete; means to edit user information.
1. Add Users
(1)
Click “”, enter the interface of “Add a User”.
Figure 4-32 Add a User
(2) Enter the desired User Name and Password (Note: User name and password
shall include letter, number and underline only. No special character is allowed.
The string length of user name is legal between 1 and 30 characters and that of
password is between 5 and 20 characters.)
(3) Click “OK” button. If the setting is successful, the new user name will
appear in the account list. Take new user “user1” as an example:
Figure 4-33
2. Delete Users
In the “Account setting” interface, click button of the “Operation” item to
delete user. The following dialog box will display:
Figure 4-31 Account Settings
45
Click “OK” button, the selected user would be deleted and the account list
would be automatically updated.
3. User Password Change
Click
will pop up:
Input the old password, enter the desired new password for twice and then click
“OK” button, the following picture will appear:
button in the account list, the dialog box of Edit User Information
Figure 4-35
Figure 4-34
46
Figure 4-37
It can display 30 logs on a page. The user can turn over the pages or skip to the
desired page by clicking the below arrows. Click “Delete logs”, a prompt will
come out. Then, click “Yes” to clear logs.
Figure 4-36
Note: The login interface will pop up if change Super user password changed.
Input Super user name and password in the interface to log, then the prompt
will inform password has been edited successfully.
4.8 System Log
Click the “Log” option tab, the date, time and log information will appear on
the right of the screen.
47
48
APPENDIX I MAGNETIC RING FILTER INSTRUCTION
To reduce electromagnetic interference that power supply generates, it is
necessary to install a magnetic ring filter with the power cable of Infinova
front-end IP device.
To install a magnetic ring filter with power supply:
Step 1: Open the magnetic ring filter and lead the power cable through.
Step 2: Wire the power cable on the magnetic ring filter 3 rounds or more
(Make sure the filter can be well closed).
Step 3: Close the magnetic ring filter.
Notice: The magnetic ring filter should be installed no more than 50 mm
away from the power output connector. As shown in Figure 3, the cable
length from A to B should be 50mm at most.
Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter
Figure 3 Power cable with magnetic ring filter
APPENDIX II QUESTIONS & SOLUTIONS
The following table describes the symptoms causes and solutions for the
problems.
Symptoms Possible Causes Solutions
The network
camera does
not perform
initiation after
power-on
No video signal
displayed
Vague image Manual focus is not precise
Wrong power connection Reconnect power cable
Power supply failure
PCB fuse damage Replace the fuse
Immediate startup after
power-off
If PoE power supply is used,
too long transmission distance
may make the power of the
Power Supply Switcher
insufficient.
If PoE power supply is used,
connection to other electric
appliance make the ground
level not in the correct level.
The plug-in for viewing image
is installed incorrectly.
Network camera’s IP address
conflicts with other user’s IP
address
Repair or replace power
supply
Restart 10 seconds later
after power-off
Shorten the length of the
power supply network
cable, or replace Power
Supply Switcher of larger
power
Disconnect other electrical
appliance.
Refer to the Plug-in
Installation to reinstall it.
Set the unique IP address
Manually adjust the camera
focus carefully.
49
APPENDIX III LIGHTNING & SURGE PROTECTION
The product adopts multi-level anti-lightning and anti- surge technology integrated with gas discharge tube,
power resistor and TVS tube. The powerful lightn ing and surge protection barrier effectively avoids
product damage caused by various pulse signals with power below 4kV, including instantaneous lightning,
surge and static. However, for complicated outdoor environment, refer to instruction below for lightning
and surge protection:
The product features with dedicated earth wire, which must be firmly grounded. As f or surveillance
sites beyond the effective protection scope, it’s necessary to erect independent lightening rods to
protect the security devices. It’s recommended to separate the lightning rod from the mountin g pole,
placing the rod on an independent pole, as shown in the figure below. If the product has to be installed
on the same pole or pedestal for lightning rod, there should be strict insul ation between the video cable
BNC terminal, power cable, control cable and the standing pole of the lightning rod.
For suburb and rural areas, it’s recommended to adopt direct burial for the transmission cables.
Overhead wiring is prohibited, because it’s more likely to encounter lightning strike. Use shielded
cables or thread the cables through metal tubes for burial, thus to ensure the electric connection to the
metal tube. In case it’s difficult to thread the cable through the tube all the way, it’s acceptable to use
tube-threaded cables only at both ends of the transmission line, yet the length in burial should be no
less than 15 meters. The cable sheath and the tube should be connected to th e lightning -proof
grounding device.
Additional high-power lightning-proof equipment and lightning rods should be installed for strong
thunderstorm or high induced voltage areas (such as high-voltage sub station).
The lightning protection and grounding for outdoor devices and wires should be designed in line with
the actual protection requirement, national standards and industrial standards.
The system should perform equipotential grounding by streaming, shielding, clamping and earthing.
The grounding device must meet anti-interference and electric safety requ irements. There should be no
short-circuiting or h ybrid junction between the de vice and the strong grid. M ake sure there’s a reliable
grounding system, with grounding resistance below 4Ω (below 10Ω for high soil resistivity regions).
The cross-s ectional area o f the earthin g conductor should be no les s than 25mm².