Dimen sion are subje ct to Manufac turer s tolerance and change w ithou t notic e. We can a ssume n o resp onsib ility for
Las dimensiones están su jetos a la tolerancia del fabricante y cambio s in prev io aviso. No po demos a sumir n inguna
responsabilidad por el us o de dato s a sustituir lo s nulos .
use of su pers eded or void dat a.
S-TIFAS 9940
S-TIFAS 9948
S-TIFAS 9960
S-TIFAS 9980
S-TIFAS 9996
Page 2
Series Components:
SS = Stainless Steel
S-AS 65 Series
SA 65 36 36″ SS Grate
SA 65 48 48″ SS Grate
SA 65 60 60″ SS Grate
LC 652 8 28″ SS Closed Ended Channel
LC 6540 40 ″ SS Closed Ended Channel
LC 655 2 52″ SS Closed Ended Channel
LC 656 4 64″ SS Closed Ended Channel
LC 658 8 88″ SS Closed Ended Channel
LF 65 8″ SS Outlet Sect ion
GJS 65 SS Joiner Str ip
TNAS SS Threaded Nipple
ZSIKA Sikaflex 1a Construction Sealant
HS 2 2" Hair Strainer
S-AS 99 Series
SA 65 36 36″ SS Grate
SA 65 48 48″ SS Grate
SA 65 60 60″ SS Grate
LC 652 8 28″ SS Closed Ended Channel
LC 6540 40 ″ SS Closed Ended Channel
LC 655 2 52″ SS Closed Ended Channel
LC 656 4 64″ SS Closed Ended Channel
LC 658 8 88″ SS Closed Ended Channel
LF 99 8″ SS Outlet Sect ion
GJS 65 SS Joiner Str ip
ZSIKA Sikaflex 1a Construction Sealant
CDI43W Cast Iron Drain Body
HS 2 2" Hair Strainer
(F1)
(F2)
*Not provide d by Inni ty Drain kits
S-DGAS 65 Series
DA 653 6 36″ SS Grate
DA 6548 48″ SS Grate
DA 656 0 60″ SS Grate
LC 652 8 28″ SS Closed Ended Channel
LC 6540 40 ″ SS Closed Ended Channel
LC 655 2 52″ SS Closed Ended Channel
LC 656 4 64″ SS Closed Ended Channel
LC 658 8 88″ SS Closed Ended Channel
LF 65 8″ SS Outlet Sect ion
GJS 65 SS Joiner Str ip
TNAS SS Threaded Nipple
ZSIKA Sikaflex 1a Construction Sealant
HS 2 2" Hair Strainer
S-DGAS 99 Series
DA 653 6 36″ SS Grate
DA 6548 48″ SS Grate
DA 656 0 60″ SS Grate
LC 652 8 28″ SS Closed Ended Channel
LC 6540 40 ″ SS Closed Ended Channel
LC 655 2 52″ SS Closed Ended Channel
LC 656 4 64″ SS Closed Ended Channel
LC 658 8 88″ SS Closed Ended Channel
LF 99 8″ SS Outlet Sect ion
GJS 65 SS Joiner Str ip
ZSIKA Sikaflex 1a Construction Sealant
CDI43W Cast Iron Drain Body
HS 2 2" Hair Strainer
KEY
(A) Top Grate –
SA65/DA65/TA65
(B) Stainless Steel Cha nnel –
LC65/HC65
(C) Outlet Sec tion –
LF65/HF65/LF99/HF99
(D) Joiner Strips - GJS 65/ TJS65
(E) Threaded Nipp le - TNAS
Weep Holes
Waterproong Membrane
(F) 2” Throat Clamp Down
Drain Body * (Two Pie ces)
4” Thr oat Cla mp Down
Drain Body for S-A S99/
S-DGA S99/S-TIFAS99
2
S-TIFAS 65 Series
TA 65 40 40″ SS Grate
TA 65 48 48″ SS Grate
TA 65 60 60″ SS Grate
HC 6532 32″ SS Closed Ended Channel
HC 65 40 40″ SS Closed Ended Channel
HC 655 2 52″ SS Closed Ended Channel
HC 6572 72″ SS Closed Ended Channel
HC 6588 88″ SS Closed Ended Chann el
HF 65 8" SS Outlet Section
TJS 65 SS Joiner St rip
TNAS SS Threaded Nipple
HS 2 2" Hair Strainer
TIF PL TIF Plates
TKEY Lift Out Key
ZSIKA Sikaflex 1a Construction Sealant
S-TIFAS 99 Series
TA 65 40 40″ SS Grate
TA 65 48 48″ SS Grate
TA 65 60 60″ SS Grate
HC 6532 32″ SS Closed Ended Channel
HC 65 40 40″ SS Closed Ended Channel
HC 655 2 52″ SS Closed Ended Channel
HC 6572 72″ SS Closed Ended Channel
HC 6588 88″ SS Closed Ended Chann el
HF 99 8″ SS Outlet Section
TJS 65 SS Joiner St rip
TIF PL TIF Plates
TKEY Lift Out Key
ZSIKA Sikaflex 1a Construction Sealant
CDI43W Cast Iron Drain Body
Note: Installer must verify all
rough-in dimensions prior to
installation and consult local
and national codes. Conformity and compliance to local
and national codes are the
responsibility of the installer.
Tenga en cuenta: Instalador
debe comprobar todas las
dimensiones en las partes previa a la instalación y consultar
localmente y nacionalmente
los códigos. La conformidad
y el cumplimiento de códigos
local y nacional es responsabi-
lidad del instalador.
Page 3
S-DGAS65/S-AS65/S-TIFAS65 kits: DO NOT
include the mechanically fastening clamp down
drain due to the variance of material by local
code. This a residential drain that is available
through Innity Drain or your local plumbing
supply from various manufacturers (i.e. Oatey®,
Sioux Chief™, JSC™, PROFLO™, Matco-Norca™).
S-DGAS99/S-AS99/S-TIFAS99 kits are
provided with a (CDI43W) Cast Iron
mechanically fastening clamp down drain
body. This item can be substituted for an ABS
or PVC drain body (CDA 43/CDP 43).
S-DGAS65/S-AS65/S-TIFAS65 kits: NO
INCLUYE la sujeción mecánica del drenaje
por la razón que varía el material de código
local. Este drenaje es residencial que está
disponible a través de Innity Drain o su
local suministro de plomería de diversos
fabricantes. (i.e. Oatey®, Sioux Chief™, JSC™,
PROFLO™, Matco-Norca™).
S-DGAS99/S-AS99/S-TIFAS99 kits son proveído
con (CDI 43 W) drenaje en hierro fundido. Este
artículo puede ser sustituto en ABS en plástico, o
PVC. (CDA 42/CDP 42/CDA 43/CDP 43).
2” clamp down drain
not included in kit
Optional Components: (Not Included)
SLA 65 St ainless Steel 90° Angle
Joiner for LC/SC Channel
TNRN St ainless Steel Threaded
Nipple Extension
UCP 2 Universal 2” Clamping Plate
UCP 4 Universal 4” Clamping Plate
2⅞"
1"
2"
6½"
Section A-A
S-DGA S 65, S -A S 65
1³⁄¹⁶"
2½"
1"
Section A-A
S-DGAS 99, S -A S 99
Available Clamp Down Drains:
CDI 22 Clamp Down Drain Cas t Iron
CDP 22 Clamp Down Drain PVC
CDA 22 Clamp Down Drain ABS
CDI 42 Clamp Down Drain, Cast Iron,
4” Throat, 2” No Hub Outlet
CDP 42 Clamp Down Drain, PVC,
4” Throat, 2” No Hub Outlet
ERB Eccent ric Reducer
Bushing 4”x2”
TE 65 2” Stainless Steel
End Section
TC 6548 48" Stainless Open
Ended Channel
TC 6596 96" Stainless Open
Ended Channel
2⅞"
1⁷⁄¹⁶"
4¹⁄¹⁶"
3"
8"
3
1⅝"
CDA 42 Clamp Down Drain, ABS,
4” Throat, 2’ No Hub Outlet
CDI 43 Clamp Down Drain, Cast Iron,
4” Throat, 3” No Hub Outlet
CDP 43 Clamp Down Drain, PVC,
4” Throat, 3” No Hub Outlet
CDA 43 Clamp Down Drain, ABS,
4” Throat, 3” No Hub Outlet
CDI43W Clamp Down Drain,
Cast Iron with threaded ring
SE 65 2” Stainless Stee l
End Section
SC 6548 48" Stainle ss Open
Ended Channel
SC 6596 96" Stainless Open
Ended Channel
SHA 65 Stainless Steel 90° Joiner
for HC/ TC Channel
1⅝"
Section A-A
2⅞"
¾"
2"
1¹¹⁄¹⁶"
2½"
2"
6½"
S-TIFAS 99
Section A-A
S-TIFAS 65
2⅞"
¾"
2"
2"
4"
3"
8"
Page 4
Installation
1. Determine the location of the drain outlet
location. Typically linear drains should span a
dimension from wall to wall, against a wall or
at a shower entrance.
Instalación
1. Determine la ubicación del emplazamiento
del drenaje. Típicamente el drenaje lineal
atraviesa una dimensión de pared a pared,
contra la pared, o en una entrada de un baño.
OPTIONAL PROCEDURE:
When drain install is required to be ush
against the nished wall, build out wall with
backer board over round clamp down drain
body (F ) to compensate for the drain radius.
PROCEDIMIENTO OPCIONAL:
Cuando el drenaje sea instalado, se requiere
que esté completamente a la pared,
construir la pared con múltiples de placas
de cemento sobre el redondo drenaje (F)
para compensar el radial del drenaje.
2. If clamp down drain body (F) is not
installed. Attach (F ) to existing waste line
and allow drain to recess into suboor.
Ensure that drain body (F) is level.
Unscrew and remove top clamp down plate
from drain body
3. Spread a primary mortar bed across the
intended shower area. Pitch this bed in four
directions towards the drain body (F).
4. When mortar layer is dry, perform
necessary waterproong (PVC Liner, CPE
Rubber Liner/Chloraloy™, Lead Pan, Copper
Pan, Hot Mop, Fiberglass) as per local code.
Ensure waterproong layer reaches the edge
of the hole in the drain body (F).
5. Calculate desired nished wall to wall
length, keeping in mind wall tile thickness
and 8”± ¼” for the outlet section (C). When
utilizing full assembly length: using a band
saw, shop saw, or a hack saw with a 32
tooth blade, cut the channel along its length
where the outlet section (C) is to be placed.
When using less than full assembly length,
remove equal amounts (half of total excess
to be removed) from each open end of
channel (B1). Gently le back rough edges.
(i.e. If 6 inches of total excess channel leng th
is to be removed. Remove 3 inches from
each open end of channel).
OPTIONAL PROCEDURE / PROCEDIMIENTO OPCIONAL
Waterproong
Membrane
Double La yer Backer
Board
(F) 2” Thro at Clamp Down Dr ain Body*
(Two P ieces )
(F1)
(F2)
2. Si el drenaje (F) no está instalado.
Adjuntar el drenaje (F) a la línea de residuos
existentes y permite el drenaje a que recese
en el piso. Asegura, que el drenaje (F) este
nivelado. Destornilla y remueve la placa de
sujeción de arriba.
3. Esparcir una primaria de capa de mortero
a través del destino o zona del baño. Lanzar
la capa de mortero en cuatro direcciones
hacia el drenaje (F).
4. Cuando la capa de mortero este seca,
realice la impermeabilización necesaria
(Forro del PVC, cobre, panal de vidrio)
según el código local. Asegura que la capa
de impermeabilización alcance al borde del
agujero en el drenaje (F).
5. Calcular deseada terminación de pared a
pared, teniendo en cuenta que el espesor de
la pared 8 ”± ¼” para la sección de salida (C).
Cuando utilice la longitud del ensamblaje
complete: usando una sierra de cinta, arco de
sierra, con 32 por pulgada de cuchilla, corte el
canal a lo largo de donde necesita la sección
de salida (C) ser colocado. Cuando se utiliza
el uso de menos de la longitud, eliminé
cantidad iguales (Mitad del exceso total que
se retira) en cada parte nal del canal (B1).
Suavemente lime de nuevo en las orillas.
(i.e. Si 6 pulgadas en total exceso tiene que ser
eliminado. Elimine 3 pulgadas de cada parte
abierta en el canal, (B1).
4
Page 5
Note: (1) Length indicated on kits are total
lengths. 8” outlet section and full stainless
channel lengths combine to create a total
length that is specied in kit description.
(2) 96” kits include 88” of stainless steel
channel to allow use of ONE outlet. (This is
not recommended)
TENGA EN CUENTA: (1) Total longitud
indicada en el ensamblaje son 8” sección de
salida y la longitud del canal de acero crea
una combinación de longitud total que es
especicado en la descripción del kit.
(2) 96” kits incluyen 88” de canal de acero
para permitir el uso de una sección/outlet.
(Esto no es recomendable)
(D) Join er Stri ps
GJS65/TJS65
(B1) Open End of Channel
Sikaex Construction
Sealant
6. Clean all parts using denatured alcohol.
On a at surface, place each cut end of the
stainless channel ush against each end
of the outlet section (C). Using provided
Sikaex 1a construction sealant place the
joiner strips (D) from the underside of
the seam to join the channel pieces to the
outlet section (C). Remove any Sikaex
spillover with a clean cloth dampened with
denatured alcohol. Allow to dry at least 8
hours before handling.
Note: Sikaex construction sealant
continues to cure for 7 days.
(B) Stainless Steel
Channel – LC65/HC65
(C) Outlet Section
LF65/HF65/LF99/HF99
6. Limpie todas las partes usando alcohol
desnaturalizado. Sobre una supercie plana,
coloque cada par te nal del canal de acero ras
contra cada lado nal de la sección de salida
(C). Usando Sikaex sellador de construcción
que es incluido, coloque la tiras/joiner strips
(D) desde la parte inferior del cordón para
unirse a la piezas del canal a la sección de
salida (C). Elimine cualquier desbordamiento
de Sikaex con un paño limpio humedecido
con alcohol desnaturalizado. Permitir que se
seque durante la noche antes de manejarlo.
TENGA EN CUENTA: Sikaex sellador de
construcción requiere 7 días para curación
completa.
7a. ONLY FOR S-AS65/S-DGAS65/S TIFAS 65 Install: Reattach the top clamp
down plate (F1) to the drain body over the
waterproong layer using bolts. Screw
threaded nipple (E) into top clamp down
plate (F1) of the drain body. Adjust to the
desired height to allow assembly to end
1/16” below the intended nished tile
height. Turn clock wise to lower, counterclockwise to raise. (Combined height of
threaded nipple (E) and stainless steel
channel assembly (B,C,&D) must be 1/16” less
than the combined height of mortar, thinset,
AND tile/oor material).
7a. SOLO PAR A S-AS65/S-DGAS65/STIFAS 65 Instalación: Reconecte la placa
de sujeción de arriba del drenaje (D2) sobre
las capas de impermeabilización utilizando
tornillo. Enrosque el niple roscado (E) adentro
de la placa del drenaje. Ajustar la altura
deseada para permitir la pieza que termine
1/16” debajo del acabado destino. Gire hacia
la derecha para bajar, hacia la izquierda para
aumentar. (La altura combinada del (niple
roscado (E) y la pieza del canal de acero (B, C, &
D) debe ser 1/16” menos de la combinación de
la altura de mortero, thinset, material de tile/
material de suelo de baldosas.)
5
Page 6
7b. ONLY FOR S-AS99/S-DGAS99/
S-TIFAS99 Install: Thread the top clamp
down plate (F1) only on to the detached
outlet section (LF99/HF99) and adjust plate
to desired height to allow outlet section
to end 1/16” below the intended nished
oor material height. Reattach the top
clamp down plate and assembled channel
to the clamp down drain body (F) over the
waterproong layer using the bolts.
7b. SOLO PARA S -AS99/S-DGAS99/
S-TIFAS99 Instalación: Rosca la parte
superior de la place del drenaje solamente
a la parte suelta (LF99/HF99) y ajuste la
placa a la altura deseada para permitir la
sección de salida que termine 1/16” debajo
del destinado material de altura. Reconecte
la placa de sujeción de arriba del drenaje
(F) sobre las capas de impermeabilización
utilizando tornillo.
7a
Mort ar Bed
(E) Th reade d
Nippl e - TNA S
(F) Clamp Down Drain Body*
(Tw o Pi ec es)
8a. ONLY FOR S-AS65/S -DGAS65/
S-TIFAS65 Install: Test t the combined
stainless steel channel onto the threaded
nipple (E) and conrm height. After
conrming correct height use Sikaex 1a
constructions sealant to join the threaded
nipple to the underside of the outlet in
the outlet section (C) of the assembled
channel. Be sure to suppor t the underside
of the assembled channel.
8b. ONLY FOR S-AS99/S-DGAS99/
S-TIFAS99 Install: Conrm the correct
height of assembled outlet section and
channel that was previously joined to the
clamp down drain.
(F1)
(F2)
Waterproong
Membrane
Suboor
7b
(B) Stainless Steel Cha nnel
(C) Outlet Section
(F1)
(F2)
(F) 4” Thr oat Cla mp Down
Drain Body * (Two Pie ces)
8a. SOLO PARA S-AS65/S-DGAS65/STIFAS65 Instalación: Pruebe y ajuste
la combinación del canal de acero en
el niple roscado (E) Y conrmar altura.
Después de conrmar la altura use Sikaex
construcción de sellador para unir la niple
roscado a parte inferior de la sección de
salida (C) del canal. Asegúrese a soportar la
parte inferior del canal.
8b. SOLO PARA S-AS99/S -DGAS99/STIFAS99 Instalación: Conrmar la correcta
altura de la sección de salida y del canal que
anteriormente fue unida al drenaje.
(B) Stainless Steel
Channel – LC65/HC65
(C) Outlet Section
LF65/LF99/HF65/HF99
(F) 2” Throat Clamp Down
Drain Body * (Two Pie ces)
(F1)
(F2)
Waterproong
Membrane
6
Shims
Mort ar Bed
Suboor
*Not pr ovide d by Innity Drain kit s
Page 7
Note:
ModelOverall Minimum HeightOverall Maximum Height
S-DGAS 65/S-AS 651 3⁄ 16”2 3⁄ 16”
S-DGA S 99/S- AS 991 7⁄16”2 7⁄16”
S-TIFAS 6 51 11⁄ 16”2 11⁄ 16”
S-TIFAS 9 92”3”
9. Create a mortar bed the length of the
channel on the waterproong membrane
and backll the underside of the assembled
stainless steel channel and level. Use
necessary amount of mortar to adequately
suppor t the channel.
10. Measure and cut the top grate (A) to a ⅛”
less than the inside leng th of the assembled
channel using a hack saw, band saw, or shop
saw with a 32 tooth per inch blade. Gently le
back the rough edges.
ONLY FOR S-TIFAS65/S -TIFAS99 INSTALL:
Measure the inside length of the channel.
Cut 5” from one end of the TA65 grate (A)
and set this aside. Cut the remainder of the
TA65 grate (A) to the measured length of
the inside channel less 5”. Join the desired
cut length to the 5” end using the provided
TIF plates and screws.
(A) Tile Inser t
32 Tooth per Inch
Blade Hacksaw
Frame – TA6 5
9. Crear un base de mor tero de la longitud del
canal en la membrana de impermeabilización
y rellene la par te de inferior del canal
de acero inoxidable y nivélelo. Utilice la
cantidad necesaria de mor tero para sopor tar
adecuadamente el canal.
10. Medir y cortar la parte superior (A) a ⅛”
menos de la longitud interior del canal usando
una sierra para metal con un hoja de 32 dientes
por pulgada, sierra de cinta. Suavemente lima
los bordes ásperos.
SOLO PARA S-TIFAS65/S-TIFAS99
Instalación: Medir la longitud de adentro
del canal. Corte 5” de un lado del nal de la
reja TA 65 (A) a la medición de la longitud del
canal por dentro menos 5”. Unir la parte que
corto de 5” usando la placa TIF y enrosca.
1
(A) Tile Insert Frame – TA65
Desired Length
32 Tooth per Inch
Blade Hacksaw
2
TIF Plates
(A) Tile Insert Frame – TA65
5 Inches
TIF Screws
3
TIF Screws
(A) Tile Insert Frame – TA65
7
4
TIF Plates
5 Inches
Page 8
11. Using desired material, mark the thickness
along the channel so that it will nish 1/16”
above the channel. Lay nal mortar bed
across the wet area. Pitch this bed in one
plane toward the linear drain. Allow space for
thinset and nishing material to nish 1/16”
above the channel. After dry, apply a bead of
silicone caulk around the channel. Lay thinset
and nishing material to the edge of the
combined stainless steel channel. DO NOT
allow material to nish on the stainless steel
channel edge. (Please refer to gures below)
11. Usando el material que desea, marque
el espesor a lo largo del canal de modo que
termine 1/16” arriba del canal. Coloque mor tero
denitivo través de la zona húmeda. Brea esto
en un plano hacia el drenaje lineal. Permita el
espacio para el thinset y material terminado
1/16” arriba del canal. Después que este
seco, aplique una gota de masilla de silicona
alrededor del canal. Colocar thinset y material
hasta el borde del canal de acero. NO PERMITA
el material que termine en el borde del canal de
acero. (Por favor referirse a las cifras inferiores)
Caulking
Mort ar Bed
Before nishing
material
Waterproong
Membrane
Mort ar Bed
Sub-oor
Antes que el material
esté terminado
12. ONLY FOR S-TIFAS 65 INSTALL:
Spread a layer of mortar into the Tile
Insert Frame (TA65), allowing for thinset
and material to finish 1/16” above the
metal frame. Allow to dry, spread thinset
and finishing material.
Assu re that g rate is l ower
than installed tile
Mort ar Bed
After nishing
material
Finishing Material
Mort ar Bed
Sub-oor
Waterproong
Membrane
Después que el material
esté terminado
12. SOLO PARA S-TIFA S 65 INSTAL ACION:
Extender una capa de mortero en Tile
Insert Frame (TA65), permitiendo el thinset
y material que termine 1/16” arriba del
marco de metal. Permita que se seque,
extienda thinset y material terminado.
Backer Board
Finishing Material
Final Mortar Bed
Suboor
Pre- Pitched Mor tar Bed
Waterproong Membrane
Threaded Outlet
Stain less Steel
Channel Assembl y
8
Loading...