Infinity Drain FFAS 65 Install Instructions [en, es]

Fixed Flange Series
Side Outlet Series
Installation Instructions
FFED 25 FTED 25
FFED 65 FTED 65
FFAS 125
FFDG 25 FTDG 25
FFDG 65 FTDG 65
FFC CUSTOM
FFMN 25 FTMN 25
FFMN 65 FTMN 65
FTC CUSTOM
FFAS 25 FTAS 25
FFAS 65 FTAS 65
FFTIF 65 FTTIF 65
The Fixed Flange Series & Side Outlet Series are intended for use with the following
Liquid Waterproofing ° Fabric Waterproofing
°
Made in the U.S.A.
Infinity Drain • 18 Secatoag Avenue, Port Washington, New York 11050
Phone 516.767.6786 • Fax 516.740.3066 • w ww.InfinityDrain.com
Las dimensi ones están sujeto s a la tole ranci a del fab rican te y camb io sin pr evio av iso. No podemos asu mir ninguna
responsab ilida d por el uso de datos a sustituir los nulos.
waterproong methods:
use of su pers eded o r void data.
Fixed Flange (FF) Series Components:
SS=Stainless Steel
FFED 25 Series
EA 653 2 32″ SS Gr ate
EA 653 6 36″ SS Gra te
EA 6542 42″ SS Gr ate
EA 6548 48" SS G rate
EA 656 0 60" SS G rate
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FFED 65 Series
EA 6524 24" SS Grat e
EA 653 2 32″ SS Gr ate
EA 653 6 36″ SS Gra te
EA 6542 42″ SS Gr ate
EA 6548 48" SS G rate
EA 656 0 60" SS G rate
FC 6524 24"SS Fixed Ch annel
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
HF 2 2" Hair St raine r
FFDG 25 Series
DA 6532 32 ″ SS Gra te
DA 6536 36 ″ SS Grat e
DA 6542 42 ″ SS Gra te
DA 654 8 4 8" SS Grate
DA 6560 6 0" SS Gra te
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FFDG 65 Series
DA 6532 32 ″ SS Gra te
DA 6536 36 ″ SS Grat e
DA 6542 42 ″ SS Gra te
DA 654 8 4 8" SS Grate
DA 6560 6 0" SS Gra te
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
HF 2 2" Hair St raine r
FFMN 25 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS G rate
MA 654 2 42″ SS Grate
MA 654 8 48 " SS Grat e
MA 656 0 60" SS Grate
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FFMN 65 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS G rate
MA 654 2 42″ SS Grate
MA 654 8 48 " SS Grat e
MA 656 0 60" SS Grate
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
HF 2 2" Hair St raine r
FFAS 25 Series
SA 6532 32″ SS Gra te
SA 6536 36″ SS Grat e
SA 654 2 42″ SS Gr ate
SA 654 8 48" S S Grate
SA 656 0 60" SS G rate
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FFAS 65 Series
SA 6524 24" SS Grat e
SA 6532 32″ SS Gra te
SA 6536 36″ SS Grat e
SA 654 2 42″ SS Gr ate
SA 654 8 48" S S Grate
SA 656 0 60" SS G rate
FC 6524 24"SS Fixed Ch annel
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
HF 2 2" Hair St raine r
FFAS 125 Series
SA 12532 32 " SS Gra te
SA 12536 36" SS Grat e
SA 12542 42 " SS Gra te
SA 1254 8 48" SS Gr ate
SA 12560 6 0" SS Gra te
FC 12532 32" SS Fi xed Channel
FC 12536 36" SS Fi xed Chan nel
FC 12542 42" SS Fi xed Channel
FC 1254 8 48" SS F ixed Channel
FC 12560 60" SS F ixed Cha nnel
FFTIF 65 Series
LA 652 4 24" SS G rate
LA 653 2 32″ SS Grate
LA 653 6 36″ SS G rate
LA 65 42 42″ SS G rate
LA 65 48 48 " SS Grat e
LA 6560 60" S S Grate
FC 6524 24"SS Fixed Ch annel
FC 6532 32" SS Fi xed Channel
FC 6536 36" SS Fi xed Chan nel
FC 654 2 42" SS Fixed Ch annel
FC 654 8 48 " SS Fixe d Channel
FC 656 0 60" SS Fixed C hannel
HF 2 2" Hair St raine r
Note: Installer must verify all rough-in dimensions prior to installation and consult local and national codes. Conformity and compliance to local and national codes are the responsibility of the installer.
Tenga en cuenta: Instalador debe
comprobar todas las dimensiones en las partes previa a la instalación y consultar localmente y nacionalmente los códigos. La conformidad y el cumplimiento de códigos local y nacional es responsabilidad del instalador.
2
Side Outlet (FT) Series Components:
SS=Stainless Steel
FTED 25 Series
EA 653 2 32″ SS Gr ate
EA 653 6 36″ SS Gra te
EA 6542 42″ SS Gr ate
EA 6548 48" SS G rate
EA 656 0 60" SS G rate
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FTAS 25 Series
SA 6532 32″ SS Gra te
SA 6536 36″ SS Grat e
SA 654 2 42″ SS Gr ate
SA 654 8 48" S S Grate
SA 656 0 60" SS G rate
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FTDG 25 Series
DA 6532 32 ″ SS Gra te
DA 6536 36 ″ SS Grat e
DA 6542 42 ″ SS Gra te
DA 654 8 4 8" SS Grate
DA 6560 6 0" SS Gra te
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FTED 65 Series
EA 6524 24" SS Grat e
EA 653 2 32″ SS Gr ate
EA 653 6 36″ SS Gra te
EA 6542 42″ SS Gr ate
EA 6548 48" SS G rate
EA 656 0 60" SS G rate
OC 6524 24" SS Fixe d Chann el
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
FTMN 25 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS G rate
MA 654 2 42″ SS Grate
MA 654 8 48 " SS Grat e
MA 656 0 60" SS Grate
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
CI 2532 32" SS Ch annel In sert
CI 2536 36" SS Cha nnel In sert
CI 2542 4 2" SS Cha nnel Ins ert
CI 254 8 48" SS Ch annel Inser t
CI 2560 6 0" SS Channel In sert
FTDG 65 Series
DA 6532 32 ″ SS Gra te
DA 6536 36 ″ SS Grat e
DA 6542 42 ″ SS Gra te
DA 654 8 4 8" SS Grate
DA 6560 6 0" SS Gra te
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
FTMN 65 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS G rate
MA 654 2 42″ SS Grate
MA 654 8 48 " SS Grat e
MA 656 0 60" SS Grate
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
FTAS 65 Series
SA 6524 24" SS Grat e
SA 6532 32″ SS Gra te
SA 6536 36″ SS Grat e
SA 654 2 42″ SS Gr ate
SA 654 8 48" S S Grate
SA 656 0 60" SS G rate
OC 6524 24" SS Fixe d Chann el
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
Optional Components: (Not Included)
ST 65 Pl acement Brac kets fo r FF25 /FF65 Seri es
ST 125 Pl aceme nt Brac kets fo r FF125 Seri es
FTTIF 65 Series
LA 652 4 24" SS G rate
LA 653 2 32″ SS Grate
LA 653 6 36″ SS G rate
LA 65 42 42″ SS G rate
LA 65 48 48 " SS Grat e
LA 6560 60" S S Grate
OC 6524 24" SS Fixe d Chann el
OC 6532 32" SS Fixed Ch annel
OC 6536 36" SS F ixed Channel
OC 6542 42" SS Fixed Ch annel
OC 654 8 48" SS Fixed Channe l
OC 6560 60" S S Fixed Channe l
3
Note: Installer must verif y all rough­in dimensions prior to installation and consult local and national codes. Conformity and compliance to local and national codes are the responsibility of the installer.
Tenga en cuenta: Instalador debe
comprobar todas las dimensiones en las partes previa a la instalación y consultar localmente y nacionalmente los códigos. La conformidad y el cumplimiento de códigos local y nacional es responsabilidad del instalador.
Fixed Flange (FF) Series:
1"
¹³⁄¹⁶"
3"
Section A-A FFED 25, FFDG 25, FFMN 25, FFAS 25
1¹⁄¹⁶"
¹³⁄¹⁶"
2¼"
FFED 65, FFDG 65, FFMN 65, FFAS 65
Side Outlet (FT) Series:
2½"
3"
2¼"
Section A-A
1¹⁄¹⁶"
2½"
2"
¹³⁄¹⁶"
3"
2¼"
Section A-A
FFTIF 65
Drain can be adjusted upward for an ad diti onal ½” in height.
⅜"
1³⁄¹⁶"
¹³⁄¹⁶"
4¹³⁄¹⁶"
3"
3¼"
1¹⁄¹⁶"
Section A-A
FFAS 125
Drain can be adjusted upward for an ad diti onal ½” in height.
1"
2⅞"
2¼"
Section B-B FTED 25, FTDG 25, FTMN 25, FTAS 25
1¹⁄¹⁶"
2½"
2⅞"
2¼"
Section B-B FTED 65, FTDG 65, FTMN 65, FTAS 65
4
1¹⁄¹⁶"
2⅞"
2¼"
Section B-B
2½"
2"
FTTIF 65
⅜"
1³⁄¹⁶"
FIXED FLANGE (FF) SERES
SIDE OUTLET (FT) SERIES
KEY
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adj ustab le Fe et
Liquid/Fabric
Waterproong
(C) Bottom
Channel – FC 65
(D) Ver tica l Ou tlet
(E) Rubber Coupling*
(F) Waste Pip e
Installation
1. Locate the waste line position. Typically
linear drains span a dimension from wall to wall, against a wall or at a shower entrance.
Note: When drain install is required to be ush against the nished wall, backer board will install over the 1” ange of the drain body.
FF (Fixed Flange Series) only:
2. Spread a prelimainar y mortar bed across the
intended drain location. Set drain into mortar bed. Connect the outlet section (D) to the existing waste pipe (F) via 2” no hub connection using a 2” DWV no hub rubber coupling (E). Allow stainless steel channel (C) to sit onto suboor.
Liquid/Fabric
KEY
Waterproong
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adj ustab le Fe et
(C) Bottom
Channel – OC 65
(D) Side Outlet
(E) Rubber Coupling*
(F) Waste Pip e
Instalación
1. Localize la posición de la línea de residuos.
Típicamente los drenajes lineales extienden a una dimensión desde pared a pared, contra una pared, o en una entrada del baño.
Tenga en cuenta: Cuando el drenaje se
instale es necesario que este contra la
pared terminada, placa de cemento se instalara sobre 1” brida del drenaje.
Solo FF (Fixed Flange Series):
2. Conecte la sección de salida (D) a la
tubería existente (F) vía 2” conexión sin concentrador usando 2” DW V goma de acoplamiento (E). Permita el canal de acero (C) sentarse en el subsuelo.
FF Series
(D) Ver tica l Outlet
(E) Rubber Coupling*
(F) Waste Pip e
(C) Bottom Channel – FC 65
FT (Side Outlet Series) only:
2. Connect the outlet section (D) to the
existing waste pipe (F) via 2” no hub connection using a 2” DWV no hub rubber coupling (E). Be sure to use integrated drain suppor ts to suppor t the stainless steel channel (C) at the desired height.
FT Series
(C) Bottom Channel – OC 65
Drain Supports
(D) Side Outlet
(E) Rubber Coupling*
(F) Waste Pip e
Solo FT (Side Outlet Series):
2. Conecte la sección de salida (D) a la tubería
de residuos existente (F) a través de 2” sin conexión concentrado usando DWV ningún acoplamiento elástico (E). Asegúrese de utilizar un drenaje integrado para soportar el canal de acero (C) a la longitud desea.
5
*Not pr ovided by In nity D rain kits
Note: When oor pitch is needed to begin at a zero level, determine the length of the channel (B) less the 1” ange around it’s perimeter. Cut a hole in the suboor to the measured dimensions at the desired location. Place the ST65/ST125 Placement Brackets (Optional Component) in the newly created hole and screw into suboor. Recess the stainless steel channel (C) into the suboor and bracket. Allow the 1” ange to sit onto the suboor.
Tenga en cuenta: Cuando el piso sea pitch es necesario que comienza a un cero nivel, determine la longitud del canal (B) menos de 1” alrededor del perímetro. Corte un agujero en el subsuelo a la dimensión medida de la ubicación deseada. Colocar el ST65/ST125 soportes de colocación (Componentes Opcionales) en el recién agujero y atornille en el subsuelo. Empotrar el canal de acero (C) en el subsuelo y soporte. Permita el 1”brida que este sentado en el subsuelo.
Limited waste pipe access:
Measure the distance from the top of the existing waste line to the top of the suboor. Ensure that the outlet section (D) is at minimum of 2” less than this dimension, cut the 3” length of the outlet section (D) if necessary. DO NOT remove more than 2” from the outlet section. Determine the distance from the bottom of the outlet section (D) to the top of the existing waste pipe (F). Cut a 2” PVC or ABS pipe to a length 1/8” less than this dimension. Bond the 2” PVC/ABS pipe to a 2” DWV PVC/ABS coupling using PVC/ABS primer and cement. Connect the other end of the 2” PVC/ABS pipe to the outlet section (D) via a 2” DWV no hub rubber coupling. Bond the free end of the 2” pipe and coupling assembly to the existing waste pipe using PVC/ABS primer and cement.
3. Spread a mor tar bed across the intended shower area and ensure the drain channel (C) is level. Back ll region under the channel 1” ange so that pitch begins level to the edge of the stainless steel channel (C). Pitch this bed one plane towards the drain body.
4. When mortar layer is dry, perform necessary waterproong (liquid membrane or fabric sheet membrane) as per local code and manufacturers’ instructions. Paint or bond waterproong directly to the channels ange.
5. After waterproong is completely dry, lay thinset and nishing material. Finish material on to the channel ange. DO NOT allow tile to nish over the depth of the channel.
Límite acceso de tubería de residuos:
Medir la distancia desde la parte superior
de la línea de residuos existentes a la parte superior del subsuelo. Asegúrese que la sección de salida (D) este mínimo 2” menos de la dimensión, corte 3” de largo de la sección de salida (D) si es necesario. NO REMUEVE más de 2.5” de la sección de salida. Determine la distancia desde debajo de la sección de salida (D) a la parte superior de la tubería existente (F). Corte un tubo de PVC o ABS a 2” a lo largo 1/8” menos de la dimensión. Una la 2” de tubería de PVC/ABS a 2” DWV PVC/ABS de acoplamiento usando PVC/ABS primer y cemento. Conecte la otra parte de 2” de tubería PVC/ABS a la sección de salida (D) vía a 2” DWV sin ningún acoplamiento elástico. Una la par te nal de la 2” de la tubería y la asamblea de acoplamiento a la existencia de la tubería de residuos usando PVC/ABS primer y cemento.
3. Extienda mor tero a través del baño previsto y asegure que el canal (C) este anivelado. Rellene la región baja del canal de 1” para que comience a brear a nivel del borde del canal de acero (C). Bree esto a un plano hacia el drenaje.
4. Cuando el motero este seco, realice la necesaria impermeabilización (Membrana de liquidó o membrana de tejido) según las reglas locales y las instrucciones del fabricante. Pinte o enlace la impermeabilización directamente al reborde del canal.
5. Después de que la impermeabilización se seque por completo, colocar el thinset y el material terminado. El material terminado hasta el borde del canal. NO PERMITA o DEJE que el tile termine encima de la profundidad del canal.
6
Waterproong Membrane
Mort ar Bed
Sub-oor
Before nishing material • Antes que el material esté terminado
Waterproong Membrane
Mort ar Bed
Sub-oor
Assure that grate is
Tile
lower than installed tile
After nishing material • Después que el material esté terminado
6. Place nished top grate (A) into the installed bottom channel (C). Use adjustable feet (B) to raise or lower the top grate to be 1/16” below the nishing material height.
Grate c an be rai sed an additional ½”
(B) Adjusta ble Fe et
Assure that grate is
Tile
lower than installed tile
6. Coloque la rejilla superior (A) en la parte inferior del canal instalado (C). Utilicé ajustables pies para levantar o bajar la rejilla a ser 1/16” debajo de la altura del material terminado.
Grate c an be rai sed an additional ½”
(B) Adjusta ble Fe et
Model
Minimum
Height
Maximum
Height
FFED25/FFED65/ FFDG25/FFDG65/ FFMN25/FFMN65/
1/” 1/”
FFAS25/FFAS65/FFAS125
FFTIF 65
1³/” 1/”
7. FFTIF 65/FT TIF 65 INSTALL. Spread a layer of mortar into the Tile Insert Frame (TA65), allowing for thinset and and nishing material to nish 1/16” above the metal frame. Allow to dry, spread thinset and lay material.
Model
Minimum
Height
Maximum
Height
FTED25/FTED65/FTDG25/ FTDG65/FTMN25/ FTMN65/FTAS25/FTAS65/
1/” 1/”
FTA S125
FT TIF 65
1³/” 1/”
7. FFTIF 65/FT TIF 65 INSTALACION. Extender
una capa de mortero en Tile Insert Frame (TA65), permitiendo el thinset y material terminado que termine 1/16” arriba del marco del metal. Permita que se seque, extienda thinset y coloca material.
7
FIXED FLANGE (FF) SERES
SIDE OUTLET (FT) SERIES
Backer Board
Thinset
Finished Grate
Finishing Material
Liquid/Fabric
Waterproong
Mort ar Bed
Suboor
Rubber Coupling
Waste Line
Stain less Steel Channel
Backer Board
Thinset
Finished Grate
Finishing Material
Liquid/Fabric
Waterproong
Mort ar Bed
Suboor
Rubber Coupling
Stain less Steel Channel
8