infinitech PREMIO 80 CFM, DECORA CFM, DECORA 80 CFM, PREMIO 110 CFM, DECORA 110 CFM Installation Manual

TM
App l i es t o a l l 80 & 1 1 0 CF M
PREMIO SERIES
DECORA SERIES
Ventil a t i on Fa n s
READ AND SAVE THESE INSTRUCTIONS
WARNING CLEANING & MAINTENANCE
www.InfiniTechInc.com
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE OBSERVE THE FOLLOWING:
Use this unit in the manner intended by the manufacturer. If
1. you have any questions, please contact the manufacturer.
Before servicing, cleaning, or maintaining the unit, switch
2. power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
Installation of unit and electrical wiring must be done in
3. accordance to all applicable codes and standards by a licensed electrician.
When cutting or drilling into walls or ceilings, make sure not
4. to damage or cut electrical wiring, plumbing, or other hidden utilities.
Always duct ventilation fans to the outdoor environment.
5.
If UL approved for installs over showers or bathtubs, install
6. on a GFCI (Ground Fault Circuit Interrupter) protected circuit.
This unit must be grounded.
7.
CAUTION
1.
Do not use to exhaust explosive materials, vapors, and hazardous materials.
2.
Do not mount product in wall. This unit is designed for ceiling installations only.
3.
Not intended for use in cooking areas.
4.
To avoid damage and/or injury, keep foreign objects from entering the fan during construction and operation.
The motor in this unit is permanently lubricated and will never need oiling.
For proper operation and long life, remove grill and dust or vacuum interior of unit every three months.
Do not use corrosive chemicals to clean plastic parts.
Make sure that power to the unit is off and locked out during cleaning to avoid damage and injury.
OPERATION
Use an on/off switch only to operate this ventilator.
Do not use this product with any solid state speed control device.
WARRANTY
InfiniTech warrants that this product will be defect free in material and workmanship for a period of three years from the date of original purchase. This warranty supersedes any and all prior warranties, expressed, implied or written. During this three year period, InfiniTech will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT COVER THE FOLLOWING:
Damage caused by improper installation and improper wiring or installation contrary to recommended installation instructions provided by the manufacturer.
Products and parts that have been modified from their original state.
Products that have been subject to improper repair, improper maintenance, abuse, misuse, or accident.
InfiniTech shall not be liable for incidental or consequential damages, or special damages including, but not limited to, loss of property, loss of revenues or profit, cost of removal, cost of installation, or cost of reinstallation, personal damage or loss of life arising out of or in connection with product use or performance.
IN STPDF 05 08
Page 1
TM
Installing the Unit
*Using the supplied hanger bars, the unit can be installed between all types of joist framings up to 16” with a minimum height clearance of 9”.
1. Remove Grill (Figure 1)
Remove the grill by pulling it away from the housing and gently squeezing the wire springs to extract them from the slots within the housing.
2. Mount Brackets
Slide the supplied mounting brackets into the appropriate slots on the housing.
3. Position
Position the housing between the joists and extend the mounting brackets until they come in contact with the joists. Make sure that the bottom edge of the unit is flush with the ceiling.
4. Mark Location
Mark the screw locations on the joists through the holes in the mounting brackets.
5. Remove
Remove the unit.
6. Mount Unit
Using the marked hole locations, drive screws part way into the joists (Screws not supplied).
7. Secure Unit (Figure 2)
Mount the unit to the joists by positioning the unit in its location using the screws in the joists. Once unit and mounting brackets are lined up, secure by driving the screws tight.
Fig ur e 1
Fig ur e 2
Fig ur e 3
8. Connect Duct (Figure 3)
Connect 4” duct to the unit by securely fastening it to the outlet. Tape all connections to eliminate leaks.
* To increase efficiency and reduce noise, use the shortest possible duct length with a minimum number of elbows. * The unit needs to be vented to the outside environment. Do not vent into the attic. * Use a roof jack or wall cap to terminate the duct run.
9. Electrical Connections (Figure 4)
Make all electrical connections as shown in the wiring diagram.
*Unit runs on 120 VAC only. *Make sure to use all UL approved connectors to secure wiring to the wiring box.
10. Put Grill (Figure 5)
Attach grill to housing by gently squeezing wire springs and inserting
them into the slots on each side of the housing. Gently push grill against the finished ceiling.
IN STPDF 05 08
Premio & Decora Fan ( 80 & 110 CFM)
Red
M
C
~
C: Capaci tor M: Moto r
Con ne ct or
Whi te
Gre en
GN D
Fa n
Fig ur e 4
Fig ur e 5
Page 2
Loading...