The TLE 4240 G is a monolithic i ntegrated low -drop LED Driv er in the very small SMD
package SCT 595. It is designed to supply LEDs under the severe conditions of
automotive applications. Therefore the device is equipped with additional protection
functions against overload, short circuit and reverse polarity and overtemperature.
The output is a constant current source which drives LEDs to 60 mA within an accuracy
of ± 20%.
Data Sheet Rev. 0.212000-08-10
TLE 4240 G
Pin Configuration
(top view)
ST
GND
Ι
1
5
2
3
4
GND
Q
AEP02906
Figure 1
Pin Definitions and Functions
Pin No.SymbolFunction
1ST Status output ; low level for open load
2GND
Ground ; internally connected to pin 5
3I Input voltage
4Q Output
5GND
Data Sheet Rev. 0.222000-08-10
Ground
TLE 4240 G
TLE 4240 G
34
I
Control
Amplifier
Buffer
Q
Tempe-
rature
Sensor
Figure 2Block Diagram
>
66 mA
Current
Limit
Control
<
1 mA
2, 5
GND
1
ST
AEB03001
Data Sheet Rev. 0.232000-08-10
TLE 4240 G
Absolute Maximum Ratings
T
– 40 °C <
ParameterSymbolLimit ValuesUnitRemarks
Input
< 150 °C
j
min.max.
Voltage
Current
Output
Voltage
Current
Status
Voltage
Current
Temperatures
Junction temperature
Storage temperature
V
I
V
I
V
I
T
T
I
Q
ST
I
Q
ST
j
stg
–4245V–
––mAinternally limited
– 140V–
––mAinternally limited
– 0.340V–
– 55mA internally limited
– 40150
C–
°
– 50150°C–
Thermal Resistances
Junction ambient
R
thja
–179K/Wzero heat sink area,
zero airflow
Note: Maximum ratings are abs olute ratings; exceeding any one of these values may
cause irreversible damage to the integrated circuit.
Data Sheet Rev. 0.242000-08-10
TLE 4240 G
Operating Range
ParameterSymbolLimit ValuesUnitRemarks
The information herein is given to describe
certain components and shall not be considered as warranted characteristics.
Terms of delivery and rights to technical
change reserved.
We hereby disclaim any and all warranties,
including but not limited to warranties of
non-infringement, regarding circuits, descriptions and charts stated herein.
Infineon Technologies is an approved CECC
manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please
contact your nearest Infineon Technologies
Office in Germany or our Infineon Technologies Representatives worldwide (see address list).
Warnings
Due to technical requirements components
may contain dangerous substances. For information on the types in question please
contact your nearest Infineon Technologies
Office.
Infineon Technologies Components may only
be used in life-support devices or systems
with the express written approval of Infineon
T echnologies , if a failure of such components
can reasonably be expected to cause the f ailure of that life-support device or system, or to
affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and
sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of
the user or other persons may be endangered.
Data Sheet Rev. 0.282000-08-10
Loading...