Inferno SRPH67, SRPH69 User Manual

OUTDOOR
GB
TM
This IM applies to both SRPH67 & SRPH69.
Keep the instructions
for future reference.
GB
1. For use outdoors or in amply ventilated areas.
2. An amply ventilated area must have a mini-
mum of 25% of the surface area open.
3. The surface area is the sum of the walls
surface.
4. This appliance is not fitted with “Atmo-
sphere sensing device”.
WARNING: The use of this appliance in enclosed areas can be dangerous and is PROHIBITED.
WARNING: Read the instructions before installation and use. Warning: This appliance must be installed and the gas cylinder stored in accordance with the regulations in force. Warning: Use only the type of gas and the type of cylinder specified by the manufac­turer. Warning: Do not obstruct the ventilation holes of the cylinder housing. Warning: In case of violent wind particular attention must be taken against tilting of the appliance. Warning: Do not move the appliance when in operation. Warning: Shut off the valve at the gas cylin­der or the regulator before moving the appli­ance. Warning: The
tubing or the flexible hose must be changed within the prescribed inter­vals. Warning: The heater can’t be used when the
heat exchange tube is retracted into cylinder compartment. Warning: Do NOT keep the heater fully
extended and the heat exchange tube must be lowered down to position during transportation!
2
Technical data
GB
Country Category Nominal heat
input(Hs)
FI
IT
NO
SK
LU
DE
DK
FR
LT
SE
RO
BG
MT
I
3B/P(50)
I
3B/P(30)
I
3+(28-30/37)
11kW 800 g/h(G30)
11kW 800 g/h(G30) 1.67mm
11kW
AT CH
SK
BE CY
EE
HU
NL
SI
HR TR
IS
BE CH CY
CZ ES FR
GB GR I E
Gas
consumption
800 g/h (G30) 1.67mm
Injector
diameter(Ø)
1.39mm G30 Butane and
Gas & Pressure
G31 Propane at
50mbar
G30 Butane and
G31 Propane at
30mbar
G30 Butane at
28-30mbar and
G31 Propane at
IT L T LU
LV PT SK
SI
PL
I
3B/P(37)
11kW
Manufacturer: SHINERICH INDUSTRIAL LIMITED Address: 8/F, Noble Center, 1006 Fuzhong 3rd Road, Futian District, Shenzhen,GD 518026, CHINA Phone: +86 - 755 - 8826 7676
800 g/h(G30)
For questions, replacement parts, service help, or other assistance, please call Distributor name Address: Email:
1.67mm
37mbar
G30 Butane and
G31 Propane at
37mbar
3
GB
Number of people required to assemble
One people
Time to assemble
10 minutes
Assembly instructions
Find a large, clean area to assemble your appliance. Please refer to the parts list and assembly diagram as necessary. Please use protective gloves when assem­bling this product. To avoid losing any small component or hardware, assemble your product on a hard level surface that does not have cracks or openings. To avoid damage to soft floor or carpet, do not assemble or move the appliance on soft floor or carpet. Follow all steps in order to properly assemble your product. Make sure all the plastic protection rip off before assembling. Do not force parts together as this can result in personal injury or damage to the product. When applicable, tighten all hardware con­nections by hand first, once the step is com­pleted, go back and full tighten all hardware.
Caution: Whilst every effort has made in manufacture of your appliance to remove any sharp edge, you should handle all com­ponents with care to avoid accidental injury.
4
Further information
GB
Important Notes:
LPG cylinder not provided. The appliance is designed to operate with a cylinder of size Ø
31.8 x 58 cm. This appliance requires a 15 kg butane LPG cylinder or a 13 kg propane LPG cylinder. Gas regulator should be the correct one and be set according to specific gas category (see Technical data on page 3). Gas regulator should be approved according to EN 12864 with proper capacity (g/h), pres­sure, working temperature and inlet + outlet connection for the country of destination. The regulator illustrated on the manual is for United Kingdom, the regulator in your country maybe different with the one on the illustration. Flexible gas rubber pipe should be approved according to EN 1763-1 with proper inner Ø to match pipe holders of gas circuit and gas regulator, pressure and working tempera­ture. The length of the hose is 0.41 m and it should not exceed 0.7 m. The hose shall be readily visible across its entire length for inspection after installation.
Connect LP Gas cylinder
Before connecting, be sure that there is no debris caught in the head of the LP tank, head of the regulator valve or in the head of the burner and burner ports. Connect gas line to tank
by turning knob clockwise until it stops, make sure that the tube is not subject to twisting. After connecting to gas cylinder, a leak test­ing is necessary.
Disconnect LP Gas cylinder
Before disconnecting make sure the LP gas tank valve in “CLOSED”. Disconnect gas line from LP gas cylinder by turning knob counterclockwise until it is loose. For storage and cylinder exchange, discon­nect hose at the cylinder only, DO NOT disconnect hose from appliance. To change the gas cylinder in an amply ven­tilated area, away from any ignition source (candle, cigarettes, other flame producing appliances…).
Danger:
You must have the proper regulator and cylinder in order for the appliance to operate safely and efficiently. Use of an incorrect or faulty regulator is dangerous and will invali­date any warranty.
5
Loading...