Dear Valued Customer,
Thank you for buying and using Industrial Scientific’s M40 Multi-Gas Monitor.
Your M40 can be relied upon for dependable service, day after day. It has been designed, manufactured, tested and proven under the most scrutinizing conditions possible. With the minimal care and maintenance described in this Instruction Manual, it will provide you with years of reliable monitoring.
I am most concerned that you be pleased with the performance of your M40 in the months and years ahead. I urge you to call us with any questions or comments you may have. Often times a phone call and a question can save you hours of frustration. Please never hesitate to contact me at 1-800-DETECTS (338-3287).
All of us at Industrial Scientific appreciate the opportunity to serve you.
Sincerely,
Kent D. McElhattan President & CEO Industrial Scientific Corporation
3
W
ARNINGS ANDCAUTIONARYSTATEMENTS
Failure to perform certain procedures or note certain conditions may impair the performance of the instrument. For maximum safety and performance, please read and follow the procedures and conditions outlined below.
Oxygen deficient atmospheres may cause combustible gas
readings to be lower than actual concentrations.
Oxygen enriched atmospheres may cause combustible gas
readings to be higher than actual concentrations.
Verify the calibration of the combustible gas sensor after any incident where the combustible gas content has caused the instrument to display an OVER-RANGE condition.
Silicone compound vapors or other known contaminants may affect the combustible gas sensor and cause readings of combustible gas to be lower than actual gas concentrations. If the instrument has been used in an area where silicone vapors were present, always calibrate the instrument before next use to ensure accurate measurements.
Sensor openings and water barriers must be kept clean. Obstruction of the sensor openings and/or contamination of the water barriers may cause readings to be lower than actual gas concentrations.
Sudden changes in atmospheric pressure may cause temporary fluctuations in the oxygen reading.
Charge battery, service unit, and use its communication port only in non-hazardous locations. Not for use in oxygen enriched atmospheres.
WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY AND MAY CAUSE AN UNSAFE CONDITION.
AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT COMPOMETTRE LA SECURITE INTINSEQUE!
CAUTION: FOR SAFETY REASONS, THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND THE INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING OR SERVICING.
ATTENTION: POUR DES RAISONS DE SÉCURITÉ, CET ÉQUIPMENT DOIT ÉTRE UTILESÉ ENTRETENU ET RÉPARÉ UNIQUEMENT PAR UN PERSONNEL QUALIFIÉ. ÉTUDIER LE MANUEL D'INSTRUCTIONS EN ENTIER AVANT D'UTILISER, D'ENTRETENIR OU DE RÉPARER L'ÉQUIPEMENT.
!
!
!
!
!
!
!
!
!
2
WARNINGS AND CAUTIONARY STATEMENTS.....................................3
UNPACKING THE INSTRUMENT ........................................................5
VIEW OF INSTRUMENT ....................................................................6
INTRODUCTION................................................................................7
INSTRUMENT OPERATION.................................................................7
M40 Gas Reading Mode......................................................7
Operating Modes .................................................................8
Zero/Calibration Mode........................................................9
Display Peaks Mode............................................................9
View TWA Mode...............................................................10
View STEL Mode..............................................................10
CONFIGURATION MODE .................................................................10
Low Alarm Set Points........................................................11
High Alarm Set Points .......................................................11
TWA Alarm Set Points ......................................................12
STEL Alarm Set Points......................................................13
Clock Setting......................................................................13
Calendar Setting.................................................................14
Security Code Setting........................................................14
LEL Setting........................................................................15
Protected Zero/Cal Setting.................................................15
ZERO/CALIBRATION.......................................................................16
DATA LOGGING.............................................................................17
LEL OVER RANGE........................................................................17
MAINTENANCE..............................................................................18
Cleaning.............................................................................18
Charging the Batteries .......................................................18
SP40 SAMPLING PUMP..................................................................18
M40 SPECIFICATIONS....................................................................19
REPLACEMENT PARTS LIST............................................................20
WARRANTY ...................................................................................21
EC DECLARATION.........................................................................23
TABLE OF CONTENTS
MULTI-GAS MONITOR
CAUTION: HIGH OFF-SCALE READINGS MAY INDICATE
EXPLOSIVE CONCENTRATION. ATTENTION: DES LECTRURES SUPÉRIEURES A L'ÉCHELLE PEUVENT
INDIQUER DES CONCETRATOINS EXPLOSIVES.
CAUTION: ANY RAPID UP-SCALE READING FOLLOWED BY A DECLINING OR ERRATIC READING MAY INDICATE A GAS CONCENTRATION BEYOND THE UPPER SCALE LIMIT WHICH MAY BE HAZARDOUS.
CANADIAN STANDARDS ASSOCIATION (CSA) HAS ASSESSED ONLY THE COMBUSTIBLE GAS DETECTION PORTION OF THIS INSTRUMENT FOR PERFORMANCE ACCORDING TO CSA STANDARD C22.2 NO. 152.
WARNING: THE ALARMS ON THE MODEL M40 ARE NON­LA TCHING ALARMS.
CAUTION: BEFORE EACH DAY’S USAGE, SENSITIVITY MUST BE TESTED ON A KNOWN CONCENTRATION OF PENTANE OR METHANE EQUIVALENT TO 25%-50% OF FULL SCALE CONCENTRATION. ACCURACY MUST BE WITHIN +/- 20% OF ACTUAL CONCENTRATION. ACCURACY MAY BE CORRECTED BY REFERRING TO THE ZERO/CALIBRATION SECTION OF THE INSTRUCTION MANUAL.
THE MODEL M40 IS CERTIFIED FOR USE WITHIN AN AMBIENT TEMPERATURE RANGE OF -20°C TO 40°C ONLY.
THE MODEL M40/SP40 COMPLIES WITH RELEVANT PROVISIONS OF EUROPEAN ATEX DIRECTIVE 94/9/EC AND EMC DIRECTIVE 89/336/EEC, AMENDED BY DIRECTIVES 92/31/EEC AND 93/68/EEC.
THE EC TYPE EXAMINATION CERTIFICATE IS DEMKO 03 ATEX 0324154X; WITH MARKING CODE EEx ia d IIC T4; FOR EQUIPMENT GROUP AND CATEGORY II 2G.
THE MODEL M40 MULTI-GAS MONITOR (P/N 1810-5437) AND MODEL SP40 SAMPLING PUMP (P/N 1810-5460) ARE CONSTRUCTED WITH REFERENCE TO PUBLISHED STANDARDS OF DIRECTIVE 72/23/EEC, TO ELIMINATE ELECTRICAL RISKS AND FULFILL 1.2.7 OF ANNEX II OF DIRECTIVE 94/9/EC.
THE MODEL M40 MUST BE USED ONLY WITH MODEL SP40 EXTERNAL SAMPLING PUMP.
FOR EUROPE ONLY, MODEL M40 AND M40/SP40 COMBINATION REQUIRE EXTERNAL PROTECTIVE MEARSURES TO PREVENT INADVERTENT ELECTROSTATIC DISCHARGE INTO EXPOSED METAL SURFACES TO MAINTAIN PERFORMANCE CRITERIA AS SPECIFIED IN EN50270 TABLE 1.4. THE M40 INSTRUMENT AND M40/SP40 COMBINATION MUST BE OPERATED WITHIN THE SUPPLIED LEATHER CASE.
!
!
!
!
!
!
!
!
!
!
!
U
NPACKING THEINSTRUMENT
The shipping box should contain the following items. Account for each item before discarding the box.
QUANTITY PART NUMBER DESCRIPTION
1 1810-5437-XXXXX M40 1 1710-8630 Swivel Belt Clip (Plastic) 1 1710-8879 Manual 1 1710-8622 Cal-Cup 1 1710-2005 Urethane Tubing 1 1710-7582 Suspender Clip 1 1810-5981 Carrying case 1 1810-5460* SP40 sampling pump 1 1810-5999* Carrying case 1 1711-6096* T -Fitting Assembly
* Items are only included in 1810-5437-1XXXX part numbers.
After unpacking, if any listed item is missing, contact either your local distributor of Industrial Scientific products or call Industrial Scientific Corporation at 1-800-DETECTS (338-3287) in the United States and Canada, or 412-788-4353.
54