Room ventilation
Disposing of combustion fumes
Positioning and levelling
Electrical connection
Gas connection
Table of burner and nozzle specifications
Table of characteristics
Description of the appliance, 6
Overall view
Control panel
Start-up and use, 7-12
Using the hob
Setting the time
Using the oven
Cooking modes for Multi-function (1rst Oven)
Cooking modes for conventional-function (2nd Oven)
Practical cooking advice
Oven cooking advice table
COOKER AND OVEN
GB
Precautions and tips, 13
General safety
Disposal
Respecting and conserving the environment
Care and maintenance, 14
Switching the appliance off
Cleaning the appliance
Replacing the oven light bulb
Gas tap maintenance
Assistance
Installation
GB
! Before operating your new appliance please read
this instruction booklet carefully. It contains
important information concerning the safe installation
and operation of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept
with the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified
professional according to the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Room ventilation
The appliance may only be installed in permanentlyventilated rooms, in accordance with current national
legislation. The room in which the appliance is
installed must be ventilated adequately so as to
provide as much air as is needed by the normal gas
combustion process (the flow of air must not be
lower than 2 m3/h per kW of installed power).
The air inlets, protected by grilles, should have a
duct with an inner cross section of at least 100 cm2
and should be positioned so that they are not liable
to even partial obstruction (see figure A).
These inlets should be enlarged by 100% - with a
minimum of 200 cm2 - whenever the surface of the
hob is not equipped with a flame failure safety
device. When the flow of air is provided in an indirect
manner from adjacent rooms (see figure B), provided
that these are not communal parts of a building,
areas with increased fire hazards or bedrooms, the
inlets should be fitted with a ventilation duct leading
outside as described above.
Adjacent roomRoom requiring
ventilation
AB
Disposing of combustion fumes
The disposal of combustion fumes should be
guaranteed using a hood connected to a safe and
efficient natural suction chimney, or using an electric
fan that begins to operate automatically every time
the appliance is switched on (see figure).
Fumes channeledoutside
Fumes channelledthrough straight a
chimney ora branched flue system
(reserved forcook ingappliances)
! The liquefied petroleum gases are heavier than air
and collect by the floor, therefore all rooms containing
LPG cylinders must have openings leading outside so
that any leaked gas can escape easily.
LPG cylinders, therefore, whether partially or
completely full, must not be installed or stored in
rooms or storage areas that are below ground level
(cellars, etc.). Only the cylinder being used should be
stored in the room; this should also be kept well
away from sources of heat (ovens, chimneys,
stoves) that may cause the temperature of the
cylinder to rise above 50°C.
Positioning and levelling
! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heatresistant material (T 90°C).
A
VentilationopeningIncreaseinthegap between
forcomburentairthedoorandthe flooring
! After prolonged use of the appliance, it is advisable
to open a window or increase the speed of any fans
used.
2
To install the appliance correctly:
• Place it in the kitchen, the dining room or the bedsit (not in the bathroom).
• If the top of the hob is higher than the cupboards,
the appliance must be installed at least 600 mm
away from them.
• If the cooker is installed underneath a wall cabinet,
there must be a minimum distance of 420 mm
between this cabinet and the top of the hob.
This distance should be increased to 700 mm if the
wall cabinets are flammable (see figure).
• Do not position
blinds behind the
cooker or less than 200
mm away from its
sides.
mm. with hood
mm. without hood
• Any hoods must be
420
650
700
installed according to
Min.mm.
min.
min.
mm.
420
Min.
HOOD
Min.mm.
900
the instructions listed in
the relevant operating
manual.
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the places
provided on each corner of the
base of the cooker (see
figure).
The legs* fit into the slots on
the underside of the base of
the cooker.
Electrical connection
WARNING – THIS APPLIANCE MUST BE
EARTHED.
The appliance is designed to work with alternating
current at the supply voltage and frequency indicated
on the rating plate (situated on the rear part of the
appliance and on the last page of the instruction
booklet) or at the end of the instruction booklet. Make
sure that the local supply voltage corresponds to the
voltage indicated on the rating plate.
To connect directly to the mains supply, a doublepole switch with a contact separation of at least 3
mm suitable for the load and complying with current
standards and regulations, must be fitted between
the appliance and the mains supply outlet. The
yellow-green earth wire must not be interrupted by
the switch. The supply cable must be in such a
position that no part of it can reach a temperature of
50 °C above room temperature. Do not use adapters
or shunts as they could cause heating or burning.
Before connecting to the power supply, make sure
that:
• the limiter valve and the domestic system can
withstand the load from the appliance (see ratingplate);
• the supply system is efficiently earthed according
to standards and laws in force;
• the socket or double-pole switch are easily
accessible when the appliance is installed.
FAILURE TO OBSERVE THE ACCIDENTPREVENTION REGULATIONS RELIEVES THE
MANUFACTURER OF ALL LIABILITY.
Important: the wires in the mains lead are coloured
in accordance with the following code:
Green & Yellow- Earth
Blue- Neutral
Brown- Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked
“E” or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or
coloured Red.
Connect the Blue wire to the terminal marked “N” or
coloured Black.
Replacing the cable
Use a rubber cable of the type H05RR-F with a
suitable
cross section 3 x 2.5 mm².
The yellow-green earth wire must be 2-3 cm longer
than the other wires.
Gas connection
Connection to the gas network or to the gas cylinder
may be carried out using a flexible rubber or steel hose,
in accordance with current national legislation and after
making sure that the appliance is suited to the type of
gas with which it will be supplied (see the rating sticker
on the cover: if this is not the case see below). When
using liquid gas from a cylinder, install a pressure
regulator which complies with current national
regulations. To make connection easier, the gas supply
may be turned sideways*: reverse the position of the
hose holder with that of the cap and replace the gasket
that is supplied with the appliance.
! Check that the pressure of the gas supply is
consistent with the values indicated in the Table of
burner and nozzle specifications (see below). This
will ensure the safe operation and durability of your
appliance while maintaining efficient energy
consumption.
Gas connection using a flexible rubber hose
GB
3
GB
Make sure that the hose complies with current
national legislation. The internal diameter of the hose
must measure: 8 mm for liquid gas supply; 13 mm for
methane gas supply.
Once the connection has been performed, make sure
that the hose:
• Does not come into contact with any parts that
reach temperatures of over 50°C.
• Is not subject to any pulling or twisting forces and
that it is not kinked or bent.
• Does not come into contact with blades, sharp
corners or moving parts and that it is not
compressed.
• Is easy to inspect along its whole length so that its
condition may be checked.
• Is shorter than 1500 mm.
• Fits firmly into place at both ends, where it will be
fixed using clamps that comply with current
regulations.
! If one or more of these conditions is not fulfilled or
if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the flexible steel
hose must be used instead (see below).
Adapting the hob
Replacing the nozzles for the
hob burners:
1. Remove the hob grids and
slide the burners off their seats.
2. Unscrewthenozzlesusing
a
7 mmsocketspanner (see
figure), and replace them with
nozzles suited to the new type of
gas (see Burner and nozzle specifications table).
3. Replace all the components by following the above
instructions in reverse.
Adjusting the hob burners minimum setting:
1. Turnthetaptotheminimumposition.
2. Removetheknobandadjust
theregulatoryscrew,
which is positioned inside or next to the tap pin, until
the flame is small but steady.
If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible:
the knob from minimum to maximum and vice versa
several times, checking that the flame is not extinguished.
Connecting a flexible jointless stainless steel pipe to
a threaded attachment
Make sure that the hose and gaskets comply with
current national legislation.
To begin using the hose, remove the hose holder on
the appliance (the gas supply inlet on the appliance
is a cylindrical threaded 1/2 gas male attachment).
! Perform the connection in such a way that the hose
length does not exceed a maximum of 2 metres,
making sure that the hose is not compressed and
does not come into contact with moving parts.
Checking the tightness of the connection
When the installation process is complete, check
the hose fittings for leaks using a soapy solution.
Never use a flame.
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Thehobburners do not require primary air adjustment.
Afteradjustingtheappliancesoitmaybeusedwitha
differenttypeofgas, replacetheoldratinglabel
witha
new one that corresponds to the new type of gas (these
labels are available from Authorised Technical Assistance
Centres).
Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations