Table of Contents
1. Product Components
2. External Features
3. Charging
4. Installing the BodyKey App
5. Powering Up
6. Syncing the InBodyBAND with the BodyKey App
7. Manual Mode
8. InBodyBAND Modes
1
2
3
4
6
8
10
12

9. Accurate Test Guidelines
10. Testing Precautions
11. InBody Test
12. Heart Rate Measurement
13. Data Management
14. General Precautions
15. Others
16. Specications
17. FCC Information
18. Telecommunication Logos
13
19
20
23
25
27
36
40
45
50

• Failure to comply with safety warnings and regulations can cause serious
injury or death.
Warning
• Failure to comply with safety cautions and regulations can cause injury or
property damage.
Caution
• Helpful information and useful tips that are handy while using the product.
Note

3
3. Charging
Charge the InBodyBAND prior to initial use.
• InBody Test, Heart rate cannot be measured while the InBodyBAND is
charging.
Note

4
4. Installing the BodyKey App
Connect this product with the BodyKey App to transfer
and monitor your data conveniently on your smartphone.
1) Search “BodyKey” in the Google Play Store or the Apple App Store.
2) Download the App.
3) Load the App and follow the instructions on-screen to sync this
product with your smartphone.

5
• This product is compatible with Android 4.3(Jellybean) with BLE or newer
and iPhone 4S/iOS7 or newer.
Note
4. Installing the BodyKey App

6
5. Powering Up
Turn on this product by holding the side button
down for 3 seconds.
The time will appear on-screen when the
product is on.

7
• This product cannot be turned off manually.
Display will turn off after 4 seconds of inactivity.
• If this product does not turn on, charge the product as instructed on page 3
until fully charged. Try turning on the product again. If the product still does not
turn on, please contact AMWAY™ Customer Service Team (page 52).
Note
5. Powering Up

8
6. Syncing the InBodyBAND with the
BodyKey App
Install the BodyKey App on your smartphone as instructed, and connect
the product to the App over Bluetooth.
1)
InBodyBAND: After charging adequately, press and hold the button
for 3 seconds to turn the power on.
2) BodyKey
App: On the
BodyKey
App, go to Settings Devices
and select the InBodyBAND to bring up the setup screen.

9
6. Syncing the InBodyBAND with the BodyKey App
• You may experience difculties linking your InBodyBAND if there are other
InBodyBANDs present.
• The time on your InBodyBAND will automatically sync with your smartphone.
Note
3)
BodyKey App: Tap the Settings button on the BodyKey App. In the
Bluetooth registration request window, tap the “OK” button and
proceed as instructed on the App.

10
7. Manual Mode
Time can be set manually if the BodyKey App is not utilised.
1. Turn on your InBodyBAND by holding the side button down for three
seconds.
2. Press the button to advance through the menu until the clock icon
shows on the screen. You will see the time.
3. Hold the button for 5 seconds to set Hours. The hours will ash.
4. Press the button to change the Hours.

11
• The InBody Test is not available if the InBodyBAND is not connected to
a smartphone.
Note
7. Manual Mode
5. Hold the side button again for 2 seconds to set Minutes.
The minutes will ash.
6. Press the button to change the Minutes.
7. Save the time by holding down the button for 3 seconds.

12
8. InBodyBAND Modes
Alternate through modes by pressing the side button.
Heart
Rate
Exercise
Duration
Distance
Covered
Battery
Life
Calories
Burned
Time
InBody
Test
Steps

13
9. Accurate Test Guidelines
If the InBodyBAND cannot come into full contact
with your wrist, fasten the band tighter or move
the band further down your arm until electrodes
are in full contact with skin.
The ideal testing position is to
wear the InBodyBAND directly
above your wristbone.

14
9. Accurate Test Guidelines
• For accurate measurement, electrodes must be in full contact with skin. In case
of poor contact between electrodes and skin, the test may not be proceeded or
test results may be inaccurate.
• To increase comparability between your results, place the InBodyBAND
on the same location on your wrist for every test.
• If skin is too dry, test may not be proceeded or test results may be inaccurate.
Please moisturise your skin before test.
Note

15
9. Accurate Test Guidelines
• In case where the user’s bioelectrical signal is weak, the test may fail, or the
results may be inaccurate.

16
Note
Stand upright for
5 minutes prior to testing.
Do not eat
prior to testing.
Use the restroom
prior to testing.
9. Accurate Test Guidelines

17
9. Accurate Test Guidelines
Note
Do not exercise
prior to testing.
Test in the
morning.
Do not drink or smoke
prior to testing.

18
9. Accurate Test Guidelines
Note
Test at room temperature to
obtain accurate measurements.
Avoid testing
on infants.

19
10. Testing Precautions
Warnings
Individuals with medical implant devices such as
pacemakers or essential support devices such as
patient monitoring systems must not take the
InBody Test.
Bioelectrical Impedance Analysis is not harmful to
the body, but it is not recommended for pregnant
women to take the test.

20
11. InBody Test
❶
Press the side button until you see InBody Test icon on the screen.
If the test icon ( ) is shown, maintain the test posture.
The wrist electrodes must touch your wrist
completely and your ngers must touch
the nger electrodes gently.
Your hands must not touch
one another.

21
Results: Percent Body Fat
❷
When the proper posture is maintained,
the test icon will change, and
InBody Test will begin automatically.
*
It takes up to 20 seconds.
❸
When the test is complete, the results
will show on the screen.
11. InBody Test

22
11. InBody Test
• You must install the BodyKey App and sync it with your InBodyBAND
before taking the InBody test for the first time.
• The Body Fat measurement will take into account your height and weight.
• Helpful information and useful tips that are handy while using the product
Note

23
12. Heart Rate Measurement
❶
Press the side button until you see Heart Rate Measurement icon on the
screen. If the test icon ( ) is shown, maintain the test posture.
The wrist electrodes must touch your wrist
completely and your ngers must touch
the nger electrodes gently.
Your hands must not touch
one another.

24
❷
When the proper posture is maintained,
the test icon will change, and Heart Rate
Measurement will begin automatically.
*
It takes up to 20 seconds.
❸
When the test is complete, the results
will show on the screen.
Results: Heart Rate
12. Heart Rate Measurement

25
13. Data Management
Your data automatically uploads to your smartphone when you
sync the InBodyBAND with the BodyKey App.
• For smooth connection, keep InBodyBAND within 2 meters from your smartphone.
Range may vary depending on environment.
• The InBodyBAND resets daily at midnight. Data will be stored for 7 days if
not uploaded to smartphone.
Note

26
• InBodyBAND starts counting steps after the 8
th
steps.
(The number of steps may change depending on the rmware version).
• The time on the InBodyBAND syncs with your smartphone’s time once the
InBodyBAND is connected to the BodyKey App.
Note
13. Data Management

27
14. General Precautions
Please read these safety warnings carefully to ensure your personal
safety and to prevent property damage.
• Do not disassemble or modify the equipment, including internal parts, without
written consent from the manufacturer. This may cause electric shock or injury,
product malfunction, inaccurate results, and will void the manufacturer’s
warranty.
Cautions

28
14. General Precautions
• Do not open the enclosure, disassemble, break, deform, bend, smash, press,
or make a hole in the product. The battery may explode.
• Do not use your InBodyBAND if the display is cracked.
• InBodyBAND is water-resistant for purposes such as washing hands.
• The InBodyBAND failures, of which water labels are discoloured due to
the user’s negligence, are not subject to warranty.
• Do not expose the InBodyBAND to excessive liquid, moisture, humidity
or rain.

29
14. General Precautions
• Do not swim with the InBodyBAND on or use it in water.
• Do not use your InBodyBAND after placing it in water for long period of time.
• Do not leave your InBodyBAND where mass amount of water can be splashed
on the product.
• Do not place the InBodyBAND in salt water/chemicals.
• Excessively bending the InBodyBAND may cause damage to the product.
• Do not drop/shock the InBodyBAND. Such impact may result in damage.

30
14. General Precautions
• Keep out of reach of children. The InBodyBAND can be a choking hazard.
• Those allergic to metal, rubber and silicon materials must not use the
InBodyBAND.
• Battery must not be deformed, changed, added with other substances, or
exposed to water or other liquid.
• Do not expose your InBodyBAND and charger under UV light for long period
of time.
• Do not use your InBodyBAND in excessively humid environments.

31
14. General Precautions
• Use the InBodyBAND in room temperature to maximise its battery capacity.
Usage of the product in low temperature may cause decrease in battery capacity.
•
Wear your InBodyBAND loosely enough to allow some air circulation.
• Do not place the InBodyBAND near a bathtub, sink, sauna, pool, or steam
room. Exposure of the InBodyBAND to excessive moisture and heat could
result in deformation/failure/explosion.
• Do not cover the InBodyBAND with any fabrics while it is charging. Doing so
may cause a fire.

32
14. General Precautions
• Please use InBodyBAND properly as instructed in this manual.
• Do not check call notifications or other data on the product’s display while
driving or in other situations where distractions could be hazardous.
• Clean and dry your InBodyBAND regularly, especially areas in contact with
the skin. Use a clean, damp cloth. Do not wash the product under a faucet.
• The InBodyBAND is classified as Class B electromagnetic radio equipment
and can be used anywhere.

33
14. General Precautions
• Do not use the InBodyBAND if you have life-sustaining medical implants
as the radio waves emitted by the InBodyBAND may interfere with the
implants.
• Keep the hand electrodes and the arm electrodes away from electricity-
conducting materials. Electrical stimuli such as strong static electricity
may cause malfunction or damage of the product.
• Bluetooth devices may cause electromagnetic interferences with multiple
electronic goods due to use of same frequency range.

34
14. General Precautions
• Electromagnetic interferences may occur while the product is operating.
Do not use the InBodyBAND for any services related to human life. In case of
communication necessarily needed or medical emergency, please use the
smartphone directly to check any incoming communication.
• The user is responsible for data transfer problems caused by using Bluetooth
function and illegal use of Bluetooth function.
• If the device is broken, get in touch with AMWAY Customer Service Team.
The user is responsible for problems caused by any arbitrary repairs.

35
14. General Precautions
• Use a lint-free cloth to gently wipe the external surface of the equipment once
every week. Be careful not to scratch the LCD screen.
• Specifications and instructions may change without prior notice.
Note

36
15. Others
Etc. Symbols
Authorized representative in the
EUROPEAN COMMUNITY
Manufacturer
Direct current
Safety Symbols
Warning, Caution, Note

37
15. Others
Temperature range 50 ~ 104ºF (10 ~ 40ºC)
Relative humidity 30 ~ 75%
Atmospheric pressure range 70 ~ 106kPa
■
Operation Conditions
Temperature range 14 ~ 158ºF (-10 ~ 70ºC)
Relative humidity 10 ~ 80% (no condensation)
Atmospheric pressure range 50 ~ 106kPa
■
Transport and Storage Conditions

38
Disposal of old Electrical & Electronic Equipment
(Application in the European Union and other
European countries with separate collection
system.) This symbol indicates that this product
shall not be treated as household waste. Instead,
it shall be handed over to the applicable collection
point for the recycling of electrical and electronic
equipment.
15. Others

39
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste
handling of this product. For more detailed information about recycling
this product, please refer to local governing ordinances and recycling
plans.
15. Others

40
16. Specications
Body Fat Analyser
•
Type of protection against electric shock: Internal Power Supply
•
Degree of protection against water infiltration: IP56
Product Name InBody Band
Country of Origin Republic of Korea
Band Material TPSIV

41
16. Specications
Data Displayed Time, PBF, Heart Rate, Steps, Exercise Duration,
Calories Burned, Distance Covered, Battery Life
Measurement
Current
90 µA and below
Data Storage 7 days
Battery Life 7-10 days (5 measurements per a day)
Recharging Time Approx. 1 hour

42
Battery Capacity 55 mAH
Charging
Connector
Micro USB
Dimensions 69 mm (W) × 104 mm (L) × 18.8 mm (H),
2.7 in (W) × 4.1 in (L) × 0.74 in (H)
Thickness : 12mm (0.47 in)
Wrists 14 ~ 20 cm (5.5 ~ 7.7 in)
Weight 25 g
16. Specications

43
Communication
Method
Bluetooth 4.0 Low Energy (BLE)
Input Power Operating Voltage: 3.7 VDC,
Charge Voltage: 5.0 VDC
Operation
Environment
10 ~ 40℃ (50 ~ 104ºF), 30 ~ 75%, 70 ~ 106kPa
Warranty 1 year (from the date of purchase)
Frequency Used 2402 MHz ~ 2480 MHz
16. Specications

44
16. Specications
No. of Channels 40
Modulation Type GFSK
Wattage 1 mW and below
*
Specifications may change without prior notice.

45
17. FCC Information
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.

46
Note: This equipment may generate or use radio frequency energy.
Change or modification to this equipment may cause harmful interference
unless the modifications are expressly approved in the instruction manual.
The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

48
17. FCC Information
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

49
17. FCC Information
End product labelling
The label for end product must include “Contains FCC ID:
F60INBODYBAND.”

50
18. Telecommunication Logos
Complies with
IDA Standards
DA103787
40097/SDPPI/2015
5053
CIDF15000136

51
LEARN MORE
To learn more about the InBodyBAND (instructions, safety information,
and customer service). Visit our site at:
AMWAY Australia
www.bodykeyau.com.au
AMWAY
Indonesia www.bodykey.co.id
AMWAY
Malaysia & Brunei www.bodykey.my
AMWAY
New Zealand www.bodykey.co.nz
AMWAY
Philippines www.bodykey.ph
AMWAY
Singapore www.bodykey.sg
AMWAY
Thailand www.bodykey.co.th
AMWAY
Vietnam www.bodykey.com.vn

52
Customer Service
Please contact AMWAY Customer Service team at the following:
AMWAY Australia 1800 454647 aufeedback@amway.com.au
AMWAY Brunei 673 2239281 MYDistribution@amway.com
AMWAY Indonesia 021 57980800 cust.srv@amway.com
AMWAY Malaysia 603 7946 2800/ 2288 MYDistribution@Amway.com
AMWAY
New Zealand
0800 611611 nzfeedback@amway.com.nz
AMWAY Philippines 632 8148181 helpdesk-phl@amway.com
AMWAY Singapore 6550 9911/ 9950 sghelpdesk@amway.com
AMWAY Thailand 02 7258000 TH_BodyKey@amway.com
AMWAY Vietnam 1900 1850 vnhelpdesk@amway.com

ⓒ
2015 InBody Co., Ltd. All rights reserved. BM-ENG2-J0-A-150605
Website: http://www.inbody.com
E-mail : info@inbody.com