in4 care KI-8210 Instruction Manual

P30 -A210
ENG IL SH
E�S �P�A� �O�L
FRA NÇ AIS
Infrared Forehead Thermometer
Mod el: IN 4 KI-8 210
INSTRUCTION MANUAL
Infrared Forehead Thermometer
Mod el: IN 4 KI-8 210
Contents
ENG IL SH
INSTRUCTION MANUAL
Precautions ............................ E1
Parts Identification ................. E2
Information You Should Know Before Operating the IR Forehead
Thermometer ......................... E2
Preparation for Use ................ E3
To Switch between ˚C and ˚F .. E3
To Take Temperature ............. E4
Measurement Hints ................ E5
To Read and Delete Memory ... E5
Cleaning and Care .................. E6
Error Message ........................ E7
Specifications ......................... E8
Limited Warranty ..................... E8
IN4 Technology Corporation
E-m ail: s ervic e@in4 -tech nolog y.com Web si te: ww w.in4-t echno logy. com
Precautions
1.Please consult your physician to verify your body temperature.
2.DO NOT scrape or scratch the lens as it will hamper the effectiveness of the unit.
3.The unit is intended for consumeruse only.
4.Calibration is recommended every two years.
Parts Identification
Information You Should Know Before Operating the Forehead Thermometer
About the Unit Preparation for UsePreparation for Use
Lens
LCD Display
Power Button
E2
Probe
Battery Cover
What are normal temperature values?
Human body temperature varies from person to person. One person's body temperatures are different from time to time. Therefore, it is very important to know your and your family members' normal body temperature ranges. Because of this, we recommend to measure yourself and your family members when healthy to obtain reference temperatures which will make you feel more confident of the measured temperature when a member of your family is ill.
How to use IR forehead thermometer correctly?
1. It is useful to try this thermometer on yourself first to be familiar with it.
2. The thermometer should be in the room where measurement will be taken 20-30 minutes prior to measurement. The
person whose temperature is being taken should be in the same room at least 20 minutes before the measurement.
3. Keep the forehead clean from sweat, make-up, etc.
4. Avoid taking measurement for 30 minutes after physical exercise, bathing or eating.
5. Body temperature, like blood pressure, varies from person to person, and during the day, it may range from 35.5˚C to
37.8˚C (95.1˚F to 100.0˚F.) The forehead temperature is converted by the thermometer to the commonly used oral temperature. For some people it may show some difference from their normal oral temperature. It is recommended to learn and recognize the forehead temperature while healthy. For accurate results, measure the same area on the forehead each time a temperature is taken.
1. Open the battery compartment cover (See drawing below).
2. Insert the batteries into the battery compartment matching correct polarities "+" and "-".
3. Replace and secure the battery compartment cover.
1 3 2
To Switch between ˚C and ˚F
1. Press the POWER button to activate the unit.
2. While the screen shows full display, press and hold the POWER button again for about 2 seconds.
MEMORY
3. The screen will show
or
4. Press and hold the POWER button for about 1 second to switch between ˚C and ˚F
E3
To Take Temperature Information You Should Know
1. Press and release the POWER button to turn on the unit. (Figure 1) Two beeps are heard. The display shows the unit is now ready for measurement. (Figure 2)
2. Place the probe in the middle of the forehead then press and hold the POWER button.
3. Move the probe across the left or right side of the forehead to
4. When you hear a "beep­beep"sound, it means the measurement is completed. (Figure 4)
5. You can repeat measurement by pressing the POWER button again after 5 seconds when the happy face icon stops flashing.
6. The unit will automatically shut off after one minute of non use. (Figure 5)
measure. Ensure proper contact between forehead and probe. During measurement the display shows an "arrow" sign
MEMORY
(Figure 3) and a measurement indicator sound should be heard. (Releasing the POWER button within 5 seconds will stop measurement or it will stop
(Figure 1)
MEMORY
MEMORY
automatically after 5 seconds.)
(Figure 2)
MEMORY
(Figure 3)
MEMORY
Measurement Hints Preparation for UseTo Read and Delete Memory
1.
1. Between measurements, please allow at least a 5-second break in order to obtain the most accurate measurement.
2. Because the thermometer is a very sensitive unit, it must be
If the power is on, wait for auto power off after one minute of non use.
2.
Press and hold the POWER button for about 2 seconds, the unit will display the last stored temperature.
MEMORYMEMORY
used at room temperature 16˚C ~ 40˚C (60.8˚F~104.0˚F).
Warning: Performance of the unit may be degraded if it is operated
3.
Press the POWER button again to go to previous memories.
MEMORYMEMORY
or stored outside the stated temperature and humidity range, or if patient's temperature is below the ambient (room) temperature.
To delete Memory
1.
While the screen displays the memory to be deleted, press and hold the POWER button for about 3 seconds, the LCD will show "dEL."
2.
Press and hold the POWER button again to delete the stored value.
MEMORY
MEMORY
(Figure 4)
E4
(Figure 5)
MEMORY
E5
Cleaning and Care Cleaning and Care
Error Message Preparation for UseTo Read and Delete Memory
Do not drop the unit. It is not shock-proof. Following mechanical shock, the unit should not be used before re-calibration.
Correction Message
The temperature measured was higher than the specified measuring range.
Please measure again.
Do not modify or disassemble the unit.
The temperature measured was lower than specified measuring range.
Use a cotton swab with alcohol to gently clean
Please measure again.
the surface of the lens. Before next measurement wait at least 40 minutes for the unit to dry.
Avoid using thinner, benzene or other harsh cleaners on the unit.
The ambient (Room) temperature was outside the operating range. Keep it at room temperature +16˚C~+40˚C (60.8˚F ~104.0˚F) for 30 minutes before using.
Initial testing error.
Z
Z
Z
Remove the batteries if the unit will not be used for a long time.
Keep the unit in a suitable place, avoid high temperature, direct sunlight, moisture or dust.
or
Have authorized dealer diagnose the error.
Low battery.
Check and replace the batteries if necessary.
No display
E6
E7
Specifications Cleaning and Care
E�S �P�A� �O�L
Power Source
DC1.5Vx2 , Type AAA batteries
Measuring Range
32.2˚C~43.3˚C (90.0˚F~109.9˚F)
Resolution
0.1˚C (0.1˚F)
Laboratory Accuracy
±0.2˚C
Memory
9 sets
Low Battery Indicator
Yes
Auto Power Off
Auto shut off after one minute of non-use
Power Consumption
4±0.5mA
Battery Life
Approximately 5000 measurements.
Operating Environment
16.0˚C~40.0˚C (60.8˚F~104.0˚F), < 95%RH
Storage Environment
-25.0˚C~55.0˚C (-13.0˚F~131.0˚F), < 95%RH
Guarantee of Quality
ISO 13485 Accuracy according to EN 12470-5 & ASTM1965-98
Limited Warranty
Thi s th ermom eter is g uaran teed for one year from the date of p urcha se a gains t man ufac turer 's de fect unde r no rmal, hou sehol d use . F ollow ing the i nstr uctio ns c losel y wi ll ens ure years of d epen dable ope ratio n. I f the ther mome ter d oes not f unct ion p rope rly, f irst che ck t he ba tteri es ( see b atte ry re plac ement inst ruct ion) and repla ce t hem i f ne cessa ry.
Spe cifi catio ns ar e su bject to chang e fo r imp rovem ent witho ut n otice . Cal ibra tion is re comm ended eve ry tw o ye ars.
E8
Termómetro Infrarrojo de Frente
MANUAL DE
Mod elo: I N4 KI- 8210
Contenidos
Precauciones ......................... S1
Identificación de las partes ..... S2
Información que debe saber Antes de operar el Termómetro IR de
Frente...................................... S2
Preparación para usar ............ S3
Para cambiar entre ºC y ºF ...... S3
Tomar la temperatura ............. S4
Pistas de medición ................. S5
Leer y suprimir la memoria ...... S5
Precauciones
1.Favor consulte su médico para verificar su temperatura.
2.NO raspe ni raye el lente, puede dañar la eficacia del aparato.
3.El aparato está diseñado para uso doméstico solamente.
4.Se recomienda una calibración cada dos años.
Limpieza y cuidado ................. S6
Mensaje de error .................... S7
Especificaciones .................... S8
Garantía limitada ..................... S8
IN4 Technology Corporation
E-m ail: s ervic e@in4 -tech nolog y.com Web si te: ww w.in4-t echno logy. com
INSTRUCCIÓN
Loading...