IMV Easi-Scan: Go Instruction Manual

Instruction manual
TM
Your complete animal imaging solution
Contents
1. Scanner menu .................................................................................................................................................
2. LED sequence ..................................................................................................................................................
4. IMV Go Scan App .........................................................................................................................................
5. Usage les .........................................................................................................................................................
6. Factory reset ....................................................................................................................................................
7. Charging ............................................................................................................................................................
8. Care & maintenance ..................................................................................................................................
9. Specications ..................................................................................................................................................
10. Service centres ...............................................................................................................................................
Certication
Hereby, IMV imaging (UK) Ltd., declares that the radio equipment type Easi-Scan:Go is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.imv-imaging.com/esg-doc/
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.
If the user makes any modications not
expressly approved by the party responsible for compliance it could void the user’s authority to operate the equipment.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Cet équipement est conforme et se soustrait de Licence au Cahier des Charges sur les Normes Radioélectriques (RSS) d’Industrie Canada.
L’opération est soumise aux deux conditions suivantes:
1. Cet appareil ne cause pas d’interférence; et
2. Cet appareil accepte toute interférence, y compris les interférence pouvant provoquer un fonctionnement indésirable de l’appareil
Contains IC4511-WL18DBMOD
Note: All IMV imaging products are for animal applications only. The product shall not be used outside its scope as declared by the manufacturer.
3
4
5
6
18
18
19
20
21
22
2 |
1. Scanner menu
Up button
Adjust gain.
Save videos.
Down button
Adjust depth.
Save images.
1.1 Scanner menu
TM
Instruction manual
Power button
To switch on/off the scanner press and hold until it beeps.
Short press to freeze the image.
If on a congested Wi­Fi channel, double press to change channel when no viewing devices are connected.
In live scanning pressing “Up” button will bring up the gain menu.
Once the gain or depth is visible, pressing the “Power Button” will select that setting. Use the Up and Down buttons to adjust the selected settings.
www.imv-imaging.com | 3
Pressing “Down” button will bring up depth menu.
1.2 Saving images and videos using the scanner buttons
Freeze the image using “Power button” Press “Up” will bring up “Save
Cine”.
Once the desired option is visible, pressing the Power Button will select that option.
Note: The scanner will store the last 300 frames (10-12.5 seconds depending on the selected scan depth) in its internal memory. To store on the scanner, the scanner must be Frozen. During save, particularly cine save, the app will pause while frames are downloading and saving the data while scanning. It is recommended that you save images and videos directly from the app where possible. The cine loop must be downloaded by the app before switching off, otherwise it will be lost. The scanner can store up to 100 images in it’s internal memory, these images are retained after power off and can be downloaded by the app at a later time.
Freeze the image using “Power
button” Press “Down” will bring up “Save Image”.
2. LED sequence
Power LED
Blue ashing Scanner turning on
Blue Scanner on and battery between 66–100% charge Yellow Scanner on and battery between 33–66% charge
Yellow ashing Scanner on and battery between 0–33% charge
Wi-Fi LED
Scanner ready for smart device to connect, nothing connected
Power LED
Wi- LED
Blue ashing
Blue Smart device connected
Both LEDs
Yellow ashing Software updating
4 |
Instruction manual
3. Activation
3.1 First time use
Download the IMV Go Scan app from Google Play or the App store.
You are likely to be prompted for a scanner software update on rst time use. Please see Scanner
Update section. To activate the scanner, ensure that the scanner is charged and that you have a local Wi-Fi
internet connection. This is only necessary the rst time you connect the scanner.
TM
1. Press “Power
1. Press “Power
button” to switch
button” to switch on the scanner.
on the scanner. Open app on the
Open app on the smart device. The
smart device. The app will request
app will request to connect to
to connect to the scanner.
the scanner. Click OK.
Click OK.
2. Select
2. Select
EASISCAN from
EASISCAN from the Wi-Fi page
the Wi-Fi page and return to
and return to the app.
the app. The app will
The app will get the serial
get the serial number from
number from the scanner.
the scanner.
3. App requests
3. App requests
to connect to
to connect to the internet.
the internet. Click OK.
Click OK.
4. Select your local Wi-Fi network to connect to the internet.
5. App retrieves the license from IMV’s license server and the app will request to connect back to the scanner.
6. Select your EASISCAN from the Wi-Fi page and return to the app.
After a few seconds, the ultrasound image will appear. Touch anywhere on the screen to bring up the live scanning menu.
Note: If the Wi-Fi LED is ashing on the scanner it is not connected to any smart device.
3.2 Normal start up process
1. Switch on the
scanner and wait until the Wi-Fi LED illuminates. Launch IMV Go Scan App. App requests to connect to scanner.
2. Select your EASISCAN from the Wi-Fi page. Return to the App.
3. It can take up to 10 seconds to connect and start receiving ultrasound. You are now ready to scan.
www.imv-imaging.com | 5
3.3 Scanner Updates
The app automatically checks the IMV licence server for scanner software updates when connected to Wi-Fi.
After connecting to an EASISCAN, you may be prompted to update the scanner software. The scanner will only update if the battery is above 50% charge.
Press OK or Cancel. Pressing OK will cause the scanner LEDs to ash yellow - the scanner will take
roughly two minutes to update. Press cancel if you wish to update later.
Once the update is nished the scanner will switch off. The scanner software version number can
be checked in the User Settings section.
4. IMV Go Scan App
4.1 Live scanning
Wi-Fi channel quality*
Recording indicator and elapsed time during recording.
No probe contact, scanner enters low-power mode and the screen will dim.
The scanner battery level
*Change the channel in Wi-Fi settings. No indicator: clear channel on the 5GHz band. This is the recommended state. White indicator: clear channel, but is on 2.4GHz band, it is more prone to interference. Orange/red indicator: channel has other networks or scanners on it. This is likely to cause interference issues.
6 |
The smart device battery level
Instruction manual
TM
Touching the screen with two ngers
simultaneously will freeze the image.
Touching the screen with one nger will open the main menu.
4.2 Main menu
Primary device indicator
Frame averaging
Meat quality Adjust scanning depth
Start recording Open Settings
To enable frame averaging, touch the icon. To change the number of frames being averaged, touch the icon (each touch increases the number of frames up to 4 then returns to 2). To disable frame averaging, long press the icon.
Frame averaging combines the current frame with the previous 2, 3 or 4 frames, this produces a smoother image with less noise, but at the cost of blurring when the probe is moving quickly.
Freeze ultrasound
Adjust gain
www.imv-imaging.com | 7
4.2.1 Freeze menu
TM
Open Settings
Adjust scanning depth
Unfreeze and return to live scanning
Callipers to measure size of the embryo
Notes
Go to cine mode
Save image on smart device
Cattle
Sheep
Horse
Draw annotations on the image
Note: Touch in the text area to type, up to 4 lines of text may be entered and will appear as red text with may be dragged to a preferred location. This text will be present on any saved images.
8 |
TM
Callipers
TM
Save images to the camera folder on a smart device
Reset the callipers to the initial position
Return to freeze menu
Note: Use your nger to move the cursors.
Cattle
TM
Instruction manual
Crown rump length
Trunk diameter
Eye diameter
Head length
Head diameter
www.imv-imaging.com | 9
Gestational measurements available:
Crown-Rump length (distance from the top of the skull to the end of the body)
14mm – 180mm, 33 – 76 days
Trunk diameter (width of the ribcage at the widest part)
14mm – 123mm, 53 – 133 days
Eye diameter (diameter of the eye socket)
3mm – 28mm, 62 – 241 days
Head diameter, (width of the skull at the widest point)
14mm – 86mm, 55 - 135 days
Horse
Gestational measurements available:
Eye diameter (diameter of eye socket)
9mm - 35mm, 99 - 344 days 14mm - 75mm, 14 - 45 days
Equine Conceptus diameter (diameter of the embryo)
Head length (distance from the top of the skull to the end of the nose)
21mm – 146mm, 56 – 134 days
10 |
Eye diameter Equine conceptus diameter
Sheep
TM
Trunk diameter (width of the ribcage at the widest part)
14mm 123mm, 53 133 days
Eye diameter (diameter of the eye socket)
3mm 28mm, 62 241 days
Head diameter, (width of the skull at the widest point)
14mm 86mm, 55 - 135 days
Crown- Rump length (distance from the top of the skull to the end of the body)
14mm 180mm, 33 76 days
Head length (distance from the top of the skull to the end of the nose)
21mm 146mm, 56 134 days
Gestational measurements available:
Gestational measurements available:
Head diameter (width of the skull at the widest point)
19mm – 66mm, 48 - 121 days 14mm – 101mm, 49 – 126 days
Head diameter Trunk diameter
Trunk diameter (width of the ribcage at the widest part)
TM
Instruction manual
Freedraw
Touch and drag to draw on screen, can be used to make simple annotations or to highlight areas of interest. Any measurements placed on screen remain visible.
Save button, save the current image to the camera folder.
Reset button, deletes all drawn lines.
Back button, return to freeze menu.
www.imv-imaging.com | 11
Cine mode
TM
Save cine
Save image
Frame back
Frame counter
4.2.2 Meat Quality
Back
Frame forward
Frame slider
Play
Fat line
12 |
Meat line
Fat and meat thickness
Sensitivity control
Instruction manual
To enable meat quality, touch the icon, to disable, touch the icon again.
When in meat quality mode the app will automatically nd the fat/muscle boundary and the reection of the rib and draw horizontal lines at both interfaces.
The gain control becomes a sensitivity control, with the sensitivity at minimum , the app looks for
the strongest reection, with the sensitivity at maximum, it uses a mixture of the average value and
the maximum, which can compensate for a poor or noisy image. The fat thickness is the distance from the probe face to the fat line and the meat thickness is the
distance between the fat line and the rib line. If the app considers the measurements to be good, then the fat line will be green and the rib line
purple, if not, then the lines will be red.
TM
Good measurement
Bad measurement
www.imv-imaging.com | 13
Recording meat quality measurements
In addition to live feedback, the app can also generate a record of the measurements as a csv
le. Freeze the image, if necessary, use the cine loop controls to nd the correct image.
Note: If the app considers the measurement to be bad (either line is red) then you cannot save the record.
Meat quality
Touch the meat quality icon, here you can enter the animal I.D. and the weight of the animal.
Animal ID
Animal weight
Save record
Touch the le icon to save the information, if this is the rst record of this session, you will be prompted to enter a lename, all further measurements will be stored in this same le.
14 |
Instruction manual
To end this session, touch the end session button, the next measurement you save will prompt for a
new le name.
TM
Indication that the record has saved
End session
Each entry in the le will contain the animal id, weight, fat thickness, meat thickness, date and
time, and the image reference for this measurement. The data is saved in a directory called BCFMQ.
www.imv-imaging.com | 15
4.3 Settings
Scanner settings
User settings
Wi-Fi settings
4.3.1 Scanner settings
BUGs brightness
Adjust screen brightness. Restores to original settings when the app is closed
Select probe orientation. The probe orientation will change on all connected devices
Access the terms and conditions, privacy policy,Quick Guide, FAQ
BUGs orientation
Adjust ultrasound contrast
Fit ultrasound by height or width
Lock screen rotation Adjust menu timeout
Invert the ultrasound image
Grid setting. The grid overlay will change on all connected devices
Note: Touching outside the menu area will return to live scanning.
16 |
4.3.2 User settings
User name
Software version of app
Number of usage les
on this device, when it was last synchronised with the server
4.3.3 Wi-Fi settings
Channels can be changed.
TM
Instruction manual
User email
Practice or company name Scanner serial number
Licence expiry date Type of scanner
Software version of scanner
2.4 GHz channels Prone to interference
Yellow, orange, red are congested channels Green are clear channels
5GHz channels. Best connection
Tap and select the channel
www.imv-imaging.com | 17
5. Usage les
The app will generate usage les.
Events logged:
Images saved – time and date, scanner serial number and location (if permitted)
Connecting to scanner
Freeze and unfreeze
Texts from Visits ToDo App
Entering and exiting standby mode
6. Factory reset
A scanner can be reset to factory rmware
settings in the unlikely event the scanner fails. Hold down Power and Down until both LEDs glow yellow and release.
Files can be uploaded to IMV’s license server, www.licencing.bcftechnology.com.
Automatically - if launching app when connected to Wi-Fi
Manually – by clicking sync button
Prompts – If there are more than 20 usage
les to upload
Our privacy policy can be viewed on our website or in the app
This will take a few minutes and the scanner will then switch off – removing the license from the
scanner.
18 |
Instruction manual
7. Charging
The battery can be charged in the charging dock, powered by a standard outlet. It can also be connected in the carry case for in-car charging.
LED sequence
Charging, charge level below 33%
Charging, charge level below 66%
Charging, charge level below 100%
Fully charged
Temperature is too high (more than 45 Celsius, 113 Fahrenheit) for safe charging
Temperature is too low (less than 0 Celsius, 32 Fahrenheit) for safe charging.
3rd LED
2nd LED
1st LED
One blue ashing
First LED solid blue Second LED lashing blue
First and second LEDs solid blue, third LED
ashing blue
All LEDs solid blue – fully charged.
All LEDs ashing yellow
All LEDs ashing blue
TM
A fully discharged battery should be fully charged within 5.5 hours. While in a good condition, the battery run time will be 5 hours (assuming 50% idle time between scans).
Scanner will enter low power mode when idle. The Li-ion cells used in the battery pack do
not suffer from the ‘Memory effect’. For optimal battery longevity, avoid letting the battery run completely down and recharge at approximately 20 Celsius/68 Fahrenheit.
Electrical connection to the power pack is through the gold pads on battery and scanner. Power pack output is protected but care should be taken to prevent short circuiting the gold connector pins and pads.
Warning:
To reduce the risk of burns, re, electric
shock, or injury to persons an appliance should never be left unattended when plugged into mains or 12 V cigarette lighter.
www.imv-imaging.com | 19
!
8. Care & maintenance
8.1 Easi-Scan:Go & battery
Please note the following important points:
The unit is not sealed against jets of water. Water will penetrate your scanner if it is
hosed down or rinsed under a fast owing
tap.
The unit is NOT corrosion proof and thus it should not be left wet.Take care to detach the external battery and ensure interconnect areas are dry also.
The battery charger and charging carry case are not waterproof – avoid getting them wet.
Probe
While every attempt has been made to make the probe as rugged as possible the crystal array remains vulnerable and should be protected from knocks. The probe has a protective sheath covering the length of cable
subject to wear and exing. Any damage to
this sheath or the rest of the cable should be repaired before further use to prevent moisture ingress that will rapidly damage the probe. The probe should be checked regularly for such damage.
Cleaning
The scanner, battery and probe can be wiped down with an antibacterial wet wipe, reducing the need for drying. This prevents problems relating to corrosion following wash-down.
The scanner and power pack can also be cleaned using a cloth, soap and warm water. Sponging down or even brief, shallow submersion is less aggressive than rinsing or hosing down.
Warning: The scanner and power pack must not be stored damp – severe corrosion will result. Thoroughly dry the scanner before storage and charging. Take care to detach the external power pack and ensure interconnect areas are dry also.
Gels
Use only gels recommended by IMV imaging. Do not store the probe in gel.
Storage
Clean and dry the probe head prior to storage in dry location. Do not store the transducer in gels or cleaning/disinfecting solutions. This will lead to premature deterioration of the probe.
Do not expose the transducer to materials containing the following agents:
Acetone
Methanol
Mineral oil
Iodine
Freon
Industrial cleaners
Materials containing perfumes (lotions, gels, etc.)
Warning:
Never sterilize the transducer with autoclave, ultraviolet, gamma radiation, gas, steam or heat sterilization techniques. Severe damage will result.
!
20 |
9. Specications
Size 19x8.3x6.2cm
7.5 x 3.25 x 2.4 in Weight 800g/1.76lbs
Mechanical Rugged Glass lled
Polypropylene casing with TPE over mould. Scanner operating frequency bands:
B1=2412MHz-2462MHz and B2=5150MHz­5250MHz
Maximum radio-frequency power transmitted in the frequency bands: 16.1dBm for B1 and 18dBm for B2.
User Output
Scanner wireless link to compatible viewing device using IMV Sound-Link over standard WI­FI connection.
Image and video storage
Storage of images and cine loops limited only by available space on smart device linked with scanner.
Probe
Broadband straight linear rectal Active array length 64 mm Frequency range 4.5 to 8.5 MHz 3 user selectable depths of scan: 6cm, 8cm, 12cm 128 element crystal array.
Power and charging
Removable li-ion battery gives 5h runtime * Battery charge time 5.5h. Only use IMV approved/supplied battery, 12V vehicle power supply, battery charger and DC power adapter. ESG-CHARGER: Input: 12V, 2A / Output: 4.2V, 2A. IMV Vehicle Power Outlet/Cigarette Plug Cable (Model: ACC-DC LEAD):12VDC, 2A Fused. Only to be used when charging from a vehicle supply. Only replace fuse with 2A medium acting fuse rated to 125V, 10kA breaking capacity (F2A M125V).
Instruction manual
DC power Adapter (XP Power, Model: VEP24US12): Input: 100-240VAC, 0.6A/Output: 12VDC, 2.0A Battery (Model: ESG-BATT): 3.6Vdc, 6700mAhr. Scanner will enter low power mode when idle.
Temperature range
Scanner: -10 Deg C to 45 Deg C *. Battery Charge: 0 Deg C to 35 Deg C * Battery Charger has under and over temperature protection and LED status indication.
Warning:
If the equipment is used in a manner
not specied by the manufacturer, the
protection provided by the equipment may be impaired.
* Best charged at 25 Deg C, frequent charging at 35 Deg C / 95 F may shorten battery lifetime.
!
Warranty
IMV imaging warrants Easi-Scan:Go against defects in materials for one year from the date of purchase. IMV imaging does not warrant against normal wear and tear,
Smart devices compatibility
Android: Minimum version: Kit Kat (Android V4.4) Minimum RAM: 2Gb Minimum Processor: Quad-Core 1.8GHz Recommended WiFi: 802.11 a/ac (5GHz band) Apple: Minimum version: iOS 8 Minimum iPhone version: iPhone 5s Minimum iPad version: iPad4
For further information and video manuals about the Easi-Scan:Go please visit the “Customer support“ section of the IMV website
www.imv-imaging.com/international/service­support.
TM
www.imv-imaging.com | 21
10. Service centres
Your equipment should be returned periodically to a IMV service centre. Our qualied service
engineers will use special test equipment to thoroughly check the instrument and advise of any work that appears to be necessary.
If your Easi-Scan requires servicing please contact an ofcial authorised service center or the
distributor in your country.
Easi-Scan:Go does not contain user serviceable parts. Servicing has to be done by IMV´s authorised service centers.
22 |
Instruction manual
TM
United Kingdom HQ
IMV imaging Imaging House Phoenix Crescent Strathclyde Business Park Bellshill ML4 3NJ Scotland, UK
+44 (0) 1506 460 023
info@imv-imaging.com
www.imv-imaging.co.uk
France
IMV imaging France 126, Boulevard de la République 16000 Angoulême, France
+33 5 45 92 03 57
france@imv-imaging.com
www.imv-imaging.fr
Ireland
IMV imaging Ireland Unit 2, Block 3 City North Business Campus Gormanston, Co. Meath K32 ER81 Ireland
+353 (0) 42 932 0070
ireland@imv-imaging.com
www.imv-imaging.ie
South Africa
IMV imaging South Africa (Pty) Ltd 6 Crieff Road Parkview Johannesburg, 2193 South Africa
+27 82 6164685
service.rsa@imv-imaging.com
www.imv-imaging.co.za
North America
IMV imaging North America, 2900 43rd St NW, Suite 600 Rochester, MN 55901
(507) 529-8200
(800) 210-9665
contact@imv-imaging.com
www.imv-imaging.com
India
IMV India Pvt. Ltd. Plot No. 750, Phase-V, Udyog Vihar, Gurugram – 122016, Haryana, India
+91 124 4770707
india@imv-imaging.com
www.imv-imaging.in
www.imv-imaging.com | 23
Contact us now
www.imv-imaging.com
+44 (0) 1506 460023
info@imv-imaging.com
facebook.com/IMVimaging
twitter/IMVimaging