IMV Easi-Scan: Go Instruction Manual

Instruction manual
TM
Your complete animal imaging solution
Contents
1. Scanner menu .................................................................................................................................................
2. LED sequence ..................................................................................................................................................
4. IMV Go Scan App .........................................................................................................................................
5. Usage les .........................................................................................................................................................
6. Factory reset ....................................................................................................................................................
7. Charging ............................................................................................................................................................
8. Care & maintenance ..................................................................................................................................
9. Specications ..................................................................................................................................................
10. Service centres ...............................................................................................................................................
Certication
Hereby, IMV imaging (UK) Ltd., declares that the radio equipment type Easi-Scan:Go is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.imv-imaging.com/esg-doc/
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.
If the user makes any modications not
expressly approved by the party responsible for compliance it could void the user’s authority to operate the equipment.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Cet équipement est conforme et se soustrait de Licence au Cahier des Charges sur les Normes Radioélectriques (RSS) d’Industrie Canada.
L’opération est soumise aux deux conditions suivantes:
1. Cet appareil ne cause pas d’interférence; et
2. Cet appareil accepte toute interférence, y compris les interférence pouvant provoquer un fonctionnement indésirable de l’appareil
Contains IC4511-WL18DBMOD
Note: All IMV imaging products are for animal applications only. The product shall not be used outside its scope as declared by the manufacturer.
3
4
5
6
18
18
19
20
21
22
2 |
1. Scanner menu
Up button
Adjust gain.
Save videos.
Down button
Adjust depth.
Save images.
1.1 Scanner menu
TM
Instruction manual
Power button
To switch on/off the scanner press and hold until it beeps.
Short press to freeze the image.
If on a congested Wi­Fi channel, double press to change channel when no viewing devices are connected.
In live scanning pressing “Up” button will bring up the gain menu.
Once the gain or depth is visible, pressing the “Power Button” will select that setting. Use the Up and Down buttons to adjust the selected settings.
www.imv-imaging.com | 3
Pressing “Down” button will bring up depth menu.
1.2 Saving images and videos using the scanner buttons
Freeze the image using “Power button” Press “Up” will bring up “Save
Cine”.
Once the desired option is visible, pressing the Power Button will select that option.
Note: The scanner will store the last 300 frames (10-12.5 seconds depending on the selected scan depth) in its internal memory. To store on the scanner, the scanner must be Frozen. During save, particularly cine save, the app will pause while frames are downloading and saving the data while scanning. It is recommended that you save images and videos directly from the app where possible. The cine loop must be downloaded by the app before switching off, otherwise it will be lost. The scanner can store up to 100 images in it’s internal memory, these images are retained after power off and can be downloaded by the app at a later time.
Freeze the image using “Power
button” Press “Down” will bring up “Save Image”.
2. LED sequence
Power LED
Blue ashing Scanner turning on
Blue Scanner on and battery between 66–100% charge Yellow Scanner on and battery between 33–66% charge
Yellow ashing Scanner on and battery between 0–33% charge
Wi-Fi LED
Scanner ready for smart device to connect, nothing connected
Power LED
Wi- LED
Blue ashing
Blue Smart device connected
Both LEDs
Yellow ashing Software updating
4 |
Instruction manual
3. Activation
3.1 First time use
Download the IMV Go Scan app from Google Play or the App store.
You are likely to be prompted for a scanner software update on rst time use. Please see Scanner
Update section. To activate the scanner, ensure that the scanner is charged and that you have a local Wi-Fi
internet connection. This is only necessary the rst time you connect the scanner.
TM
1. Press “Power
1. Press “Power
button” to switch
button” to switch on the scanner.
on the scanner. Open app on the
Open app on the smart device. The
smart device. The app will request
app will request to connect to
to connect to the scanner.
the scanner. Click OK.
Click OK.
2. Select
2. Select
EASISCAN from
EASISCAN from the Wi-Fi page
the Wi-Fi page and return to
and return to the app.
the app. The app will
The app will get the serial
get the serial number from
number from the scanner.
the scanner.
3. App requests
3. App requests
to connect to
to connect to the internet.
the internet. Click OK.
Click OK.
4. Select your local Wi-Fi network to connect to the internet.
5. App retrieves the license from IMV’s license server and the app will request to connect back to the scanner.
6. Select your EASISCAN from the Wi-Fi page and return to the app.
After a few seconds, the ultrasound image will appear. Touch anywhere on the screen to bring up the live scanning menu.
Note: If the Wi-Fi LED is ashing on the scanner it is not connected to any smart device.
3.2 Normal start up process
1. Switch on the
scanner and wait until the Wi-Fi LED illuminates. Launch IMV Go Scan App. App requests to connect to scanner.
2. Select your EASISCAN from the Wi-Fi page. Return to the App.
3. It can take up to 10 seconds to connect and start receiving ultrasound. You are now ready to scan.
www.imv-imaging.com | 5
3.3 Scanner Updates
The app automatically checks the IMV licence server for scanner software updates when connected to Wi-Fi.
After connecting to an EASISCAN, you may be prompted to update the scanner software. The scanner will only update if the battery is above 50% charge.
Press OK or Cancel. Pressing OK will cause the scanner LEDs to ash yellow - the scanner will take
roughly two minutes to update. Press cancel if you wish to update later.
Once the update is nished the scanner will switch off. The scanner software version number can
be checked in the User Settings section.
4. IMV Go Scan App
4.1 Live scanning
Wi-Fi channel quality*
Recording indicator and elapsed time during recording.
No probe contact, scanner enters low-power mode and the screen will dim.
The scanner battery level
*Change the channel in Wi-Fi settings. No indicator: clear channel on the 5GHz band. This is the recommended state. White indicator: clear channel, but is on 2.4GHz band, it is more prone to interference. Orange/red indicator: channel has other networks or scanners on it. This is likely to cause interference issues.
6 |
The smart device battery level
Instruction manual
TM
Touching the screen with two ngers
simultaneously will freeze the image.
Touching the screen with one nger will open the main menu.
4.2 Main menu
Primary device indicator
Frame averaging
Meat quality Adjust scanning depth
Start recording Open Settings
To enable frame averaging, touch the icon. To change the number of frames being averaged, touch the icon (each touch increases the number of frames up to 4 then returns to 2). To disable frame averaging, long press the icon.
Frame averaging combines the current frame with the previous 2, 3 or 4 frames, this produces a smoother image with less noise, but at the cost of blurring when the probe is moving quickly.
Freeze ultrasound
Adjust gain
www.imv-imaging.com | 7
4.2.1 Freeze menu
TM
Open Settings
Adjust scanning depth
Unfreeze and return to live scanning
Callipers to measure size of the embryo
Notes
Go to cine mode
Save image on smart device
Cattle
Sheep
Horse
Draw annotations on the image
Note: Touch in the text area to type, up to 4 lines of text may be entered and will appear as red text with may be dragged to a preferred location. This text will be present on any saved images.
8 |
Loading...
+ 16 hidden pages