IMRELAX IM-MH0610 User Manual

1. This product is in good performance situation and completely packed before leaving factory. Users should be strictly abide by the below cautions and operation instructions, any damage caused by misuse is not within the company warranty;
2. There are no prior notice for the change of the technology information in the manual, as the upgrading of the product.
(6pcs*10W RGBW 4in1 LED
User Manual
Please read this user manual before using this product
Product statement
DMX signal
1. When opening the packing, take all accessories out, and remove the light to a horizontal table for good operation. First check whether the accessories are complete, then check carefully whether the whole light has no damage. If there is any damage, please contact us as soon as possible.
2. AC Power:Check whether the local power supply is accordance with the requirements of the product rated voltage.
3. The product is only suitable for indoor working environment. The light should keep dry, keep away from wet, overheat or dusty environment. Don't come into contact with water and other liquids to prevent or reduce the risk of electric shock or fire.
4. Please do not install the light directly on the surface of the combustible substance.
5. The people who install, operate and maintain of light professional certificate required.
6. When there are faults of the light, please stop using the light immediately. Don't try to repair, please contact the nearest authorized technical assistance center, if the parts damage, always use the same type of parts replaced.
7. Don't touch any electrical wiring in the process of operation to prevent the risk of electric shock.
8. To make sure the light working environment temperature, the highest do not exceed 40
℃,
the lowest do not exceed - 20℃.
9. Under the stable cooling working situation, the highest temperature of the
housing of the light can reach 80 , please do not touch.
10. The light is design according to the type of electric shock protection. The light should be use in good connection grounding power system and the earth sign port of the light should be connected to the installing fixtures.
11. Do not use the damage of the insulating layer wire and also do not use the power cord overlap on the other wire. When not in use or clean the light,
16CH
Channel
Value
Function
CH1
000-255
Pan Position
CH2
000-255
Pan Fine
CH3
000-255
Tilt Position
CH4
000-255
Tilt Fine
CH5
000-255
Motor run speed, fast to slow
CH6
000-127
Lense Counterclockwise rotate movement
128-190
Lense clockwise rotate movement
191-193
Stop
194-255
Lense Counterclockwise rotate movement
CH7
000-255
Dimmer,0-100%
CH8
000-008
No function
009-255
Strobe,Slow to fast
CH9
000-255
R dimmer0-100%
CH10
000-255
G dimmer0-100%
CH11
000-255
B dimmer0-100%
CH12
000-255
W dimmer,0-100%
CH13
000-007
No function
008-255
Color change
CH14
000-008
No function
009-068
Show 1
069-128
Show 2
129-188
Show 3
189-239
Show 4
240-255
Sound active
CH15
000-255
Speed, slow to fast
CH16
000-249
No function
250-255
Rest
Safety instruction