Impulse DSCT34 User Manual

DSCT34
Linearized 2- or 3-Wire RTD Input Transmitters
Description
Each DSCT34 RTD input transmitter provides a single channel of RTD input
which is filtered, isolated, amplified, linearized, and converted to a process
current output (Figure 1). Signal filtering is accomplished with a five-pole filter,
which provides 85dB of normal-mode-rejection at 60Hz and 80dB at 50Hz. An
anti-aliasing pole is located on the field side of the isolation barrier, and the other
four are on the process loop side. After the initial field-side filtering, the input signal
is chopped by a proprietary chopper circuit. Isolation is provided by transformer
coupling, again using a proprietary technique to suppress transmission of
common mode spikes or surges.
RTD excitation is provided from the transmitter using a precision current source.
The excitation currents are very small (0.26mA max for 100 Pt and 120 Ni)
which minimizes self-heating of the RTD. Linearization is achieved by creating
a non-linear transfer function through the module itself. This non-linear transfer
function is configured at the factory and is designed to be equal and opposite
to the specific RTD non-linearity. Lead compensation is achieved by matching
two current paths thus canceling the effects of lead resistance.
The specifications listed are for a 3-wire connection. A 2-wire connection of the
RTD to the module is also possible and is achieved by adding a jumper between
pin 5 (+EXC) and pin 6 (+IN) on the terminal block and connecting the RTD leads
between pin 6 (+IN) and pin 7 (-IN). The 2-wire connection nullifies the lead
resistance compensation feature of the module.
DIN Rail Mount Two-WireTransmitters
 Interfaces to 100 Platinum or 120
Nickel RTDs
 Linearizes RTD Signal
 Process Current Output
 1500Vrms Transformer Isolation
 ANSI/IEEE C37.90.1 Transient Protection
 Input and Output Protected to 240VAC Continuous
 Up to 60V Loop Voltage
 160dB CMR
 85dB NMR at 60Hz, 80dB at 50Hz
 ±0.1% Accuracy
 ±0.025% Conformity
 Easily Mounts on Standard DIN Rail
 CSA and FM Approvals Pending
 CE Compliant
DSCT
Special input and output circuits on the DSCT34 transmitters provide protection
against accidental connection of power-line voltages up to 240VAC and against
transient events as defined by ANSI/IEEE C37.90.1. Signal and loop power
lines are secured to the module using screw terminals, which are in pluggable
terminal blocks for ease of system assembly and reconfiguration.
The modules have excellent stability over time and do not require recalibration,
however, zero and span settings are adjustable up to ±3% to accommodate
situations where fine-tuning is desired. The adjustments are made using
potentiometers located under the front panel label and are non-interactive for
ease of use.
Figure 1: DSCT34 Block Diagram
204
For information call 800-444-7644
DIN Rail Mount Two-Wire Transmitters
DSCT
Specifications
Module
Input Range -200°C to +850°C (100 Pt)
Input Resistance
Normal 50M Power Off 66k Overload 66k
Input Protection
Continuous 240Vrms max
Transient ANSI/IEEE C37.90.1
CMV, Input to Output
Continuous 1500Vrms max
Transient ANSI/IEEE C37.90.1
CMR (50Hz or 60Hz) 160dB
NMR 85dB at 60Hz, 80dB at 50Hz
Adjustability ±3% Zero and Span
Accuracy See Ordering Information
Conformity ±0.025%
Stability
Offset ±50ppm/°C
Gain ±100ppm/°C
Sensor Excitation Current 0.260mA
Lead Resistance Effect ±0.02°C/W
Noise
Output, 100kHz 3µArms
Bandwidth, 3dB 3Hz
Response Time, 90% Span 165ms
Output Range 4mA to 20mA
Output Limits
Under-range 3mA
Over-range 29mA
Output Protection
Reverse Polarity Continuous
Over-voltage 240Vrms Continuous
Transient ANSI/IEEE C37.90.1
Loop Supply Voltage 10.8V to 60V
Loop Supply Sensitivity ±0.0005%/V
Turn-On Delay 400ms
Typical at TA=+25°C and +24V loop voltage
DSCT34
-80°C to +320°C (120 Ni)
Ordering Information
Model
ΩΩ
100
Pt **
ΩΩ
DSCT34-01 -100°C to +100°C ±0.1% ±0.2°C
DSCT34-02 0°C to +100°C ±0.1% ±0.1°C
DSCT34-03 0°C to +200°C ±0.1% ±0.2°C
DSCT34-04 0°C to +600°C ±0.1% ±0.6°C
DSCT34-05 0°C to +400°C ±0.1% ±0.4°C
ΩΩ
Ni **
120
ΩΩ
DSCT34N-01 0°C to +300°C ±0.1% ±0.3°C
**RTD Standards
Type Alpha Coefficient DIN JIS
100Pt 0.00385 DIN 43760 JIS C 1604-1989 120 Ni 0.00672
Input Range
(-148°F to +212°F)
(+32°F to +212°F)
(+32°F to +392°F)
(+32°F to +1112°F)
(+32°F to +752°F)
(+32°F to +572°F)
Accuracy
(1)
Environmental
Operating Temp. Range 40°C to +80°C
Storage Temp. Range 40°C to +80°C
Relative Humidity 0 to 95% Noncondensing
Emissions EN50081-1, ISM Group 1,
Class A (Radiated, Conducted)
Immunity EN50082-1, ISM Group 1,
Class A (ESD, RF, EFT)
Mechanical Dimensions 2.95" x 0.89" x 4.13
(h)(w)(d) (75mm x 22.5mm x 105mm)
Mounting DIN EN 50022 35x7.5 or 35x15 rail
NOTES:
(1) Includes conformity, hysteresis and repeatability.
Visit our website www.dataforth.com
DSCT
205
Loading...