Description
Each DSCA30/31 voltage input module provides a single channel of analog
input which is filtered, isolated, amplified, and converted to a high level voltage
output. Signal filtering is accomplished with a five-pole filter which provides
85dB of normal-mode-rejection at 60Hz and 80dB at 50Hz. An anti-aliasing
pole is located on the field side of the isolation barrier, and the other four poles
are on the system side. After the initial field-side filtering, the input signal is
chopped by a proprietary chopper circuit. Isolation is provided by transformer
coupling, again using a proprietary technique to suppress transmission of
common mode spikes or surges.
Module output is either voltage or current. For current output models a dedicated
loop supply is provided at terminal 3 (+OUT) with loop return located at terminal
4 (-OUT). The system-side load may be either floating or grounded.
Special input circuits provide protection against accidental connection of
power-line voltages up to 240VAC and against transient events as defined by
ANSI/IEEE C37.90.1. Protection circuits are also present on the signal output
and power input terminals to guard against transient events and power reversal.
Signal and power lines are secured to the module using screw terminals which
are in pluggable terminal blocks for ease of system assembly and reconfiguration.
The modules have excellent stability over time and do not require recalibration,
however, zero and span settings are adjustable up to ±5% to accommodate
situations where fine-tuning is desired. The adjustments are made using
potentiometers located under the front panel label and are non-interactive for
ease of use.
Features
 Accepts Millivolt and Voltage Level Signals
 Industry Standard Output of either 0 to 10V/±10V,
0 to 20mA, or 4 to 20mA
 ANSI/IEEE C37.90.1 Transient Protection
 Input Protected to 240VAC Continuous
 True 3-Way Isolation
 Wide Range of Supply Voltage
 160dB CMR
 85dB NMR at 60Hz, 80dB at 50Hz
 ±0.03% Accuracy
 ±0.01% Linearity
 Easily Mounts on Standard DIN Rail
 C-UL-US Listed
 CE and ATEX Compliant
DSCA
Figure 1: DSCA30/31 Block Diagram
130
For information call 800-444-7644
High Performance Signal Conditioners
DSCA
Specifications
Typical at TA = +25°C and +24V voltage supply
Model DSCA30 DSCA31
Input Range ±10mV to +100mV ±1V to ±40V
Input Bias Current ±0.5nA ±0.05nA
Input Resistance
Normal 50M 500kΩ min Power Off 65k 500kΩ min Overload 65k 500kΩ min
Input Protection
Continuous 240Vrms max *
Transient ANSI/IEEE C37.90.1 *
Output Range See Ordering Information
Load Resistance (I
Current Limit 8mA (V
Output Protection
Short to Ground Continuous *
Transient ANSI/IEEE C37.90.1 *
CMV, Input to Output, Input to Power
Continuous 1500Vrms max *
Transient ANSI/IEEE C37.90.1 *
CMV, Output to Power
Continuous 50VDC max *
CMR (50Hz or 60Hz) 160dB *
Accuracy
(1)
Nonlinearity ±0.01% Span *
Adjustability ±5% Zero and Span *
Stability
Input Offset ±0.5µV/°C ±5µV/°C
Output Offset ±6ppm/°C (V
Zero Suppression ±50ppm(Vz)
Gain ±35ppm/°C ±55ppm/°C
Output Noise, 100kHz BW 250µVrms (V
Bandwidth, 3dB 3Hz *
NMR 85dB at 60Hz, 80dB at 50Hz *
Response Time, 90% Span 165ms *
Power Supply
Voltage 15 to 30VDC *
Current 25mA (V
Sensitivity ±0.0001%/% *
Protection
Reverse Polarity Continuous *
Transient ANSI/IEEE C37.90.1 *
Environmental
Operating Temp. Range 40°C to +80°C *
ATEX Group II, Category 3 20°C to +40°C *
Storage Temp. Range 40°C to +80°C *
Relative Humidity 0 to 95% Noncondensing *
Emissions EN61000-6-4 ISM, Group 1 *
Radiated, Conducted Class A *
Immunity EN61000-6-2 ISM, Group 1 *
R F Performance A ±0.05% Span Error *
ESD,EFT,Surge,Voltage Dips Performance B *
Mechanical Dimensions 2.95" x 0.89" x 4.13" *
(h)(w)(d) (75mm x 22.5mm x 105mm)
Mounting DIN EN 50022 -35x7.5 or -35x15 rail *
NOTES:
* Same specification as DSCA30.
(1) Includes nonlinearity, hysteresis and repeatability.
is the nominal input voltage that results in 0V or 0mA output.
(2) V
z
) 600 max *
OUT
), 30mA (I
OUT
)*
OUT
±0.03% Span *
), ±20ppm/°C (I
OUT
(2)
/°C *
), 1µArms (I
OUT
), 55mA (I
OUT
)*
OUT
)*
OUT
)*
OUT
Ordering Information
Model Input Range Output Range
DSCA30-01 -10mV to +10mV 1
DSCA30-02 -50mV to +50mV 1
DSCA30-03 -100mV to +100mV 1
DSCA30-04 -10mV to +10mV 2, 3, 4
DSCA30-05 -50mV to +50mV 2, 3, 4
DSCA30-06 -100mV to +100mV 2, 3, 4
DSCA30-07 0 to +10mV 2, 3, 4
DSCA30-08 0 to +50mV 2, 3, 4
DSCA30-09 0 to +100mV 2, 3, 4
DSCA31-01 -1V to +1V 1
DSCA31-02 -5V to +5V 1
DSCA31-03 -10V to +10V 1
DSCA31-04 -1V to +1V 2, 3, 4
DSCA31-05 -5V to +5V 2, 3, 4
DSCA31-06 -10V to +10V 2, 3, 4
DSCA31-07 -20V to +20V 1
DSCA31-08 -20V to +20V 2, 3, 4
DSCA31-09 -40V to +40V 1
DSCA31-10 -40V to +40V 2, 3, 4
DSCA31-11 0 to +1V 2, 3, 4
DSCA31-12 0 to +5V 2, 3, 4
DSCA31-13 0 to +10V 2, 3, 4
DSCA31-14 0 to +20V 2, 3, 4
DSCA31-15 0 to +40V 2, 3, 4


Output Ranges Available
Output Range Part No. Suffix Example
1. -10V to +10V NONE DSCA30-01
2. 0V to +10V NONE DSCA30-04
3. 4 to 20mA C DSCA30-04C
4. 0 to 20mA E DSCA30-04E
DSCA
Installation Notes:
1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D, or Non-Hazardous Locations Only.
2.) Warning - Explosion Hazard - Substitution of Components May Impair Suitability for Class I, Division 2.
3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The
Area is Known to be Non-Hazardous.
Visit our website www.dataforth.com