The REL-16.PCI provides 16 reed relay outputs. The outputs offer high quality, long
life, low current (10 Watt maximum), dry contact switch closures. Reed relays are
well suited for low current applications. The relays are normally open, and will close
when energized. The board is PCI bus specification 2.1 compliant.
The REL-16.PCI is designed to be used with a variety of Operating Systems
including Windows 98/NT/ME/2000/XP, Linux and DOS. The SeaI/O API
(Application Programmer Interface) included on CD with the REL-16.PCI provides
a variety of useful high-level function calls implemented as a Windows dynamic
link library (DLL) and as a Linux kernel module and library. In addition to the API,
SeaI/O includes sample code and utilities to simplify software development.
The REL-16.PCI is shipped with the following items. If any of these items is
missing or damaged please contact Sealevel for replacement.
REL-16.PCI Adapter
Sealevel SeaI/O Software CD
Optional Items
Depending upon your application, you are likely to find one or more of the
following items useful for interfacing the REL-16.PCI to real-world signals. All
items can be purchased from our website (http://www.sealevel.com
(864) 843-4343.
DB-37 Male to DB-37 Female 6’ Cable - (Part Number CA112)
− This cable extends the DB-37 connector on the REL-16.PCI to six
feet and is pinned one-to-one.
DB-37 Male/Female Terminal Block (Part Number TB02-KT)
− Break out serial and digital connectors to 37 screw terminals for easy
field connection. The TB02 terminal block is designed with both DB37 male and female connectors, therefore; it can be used with any
DB-37 board regardless of the board's port gender.
) or by calling
Cable and Terminal Block Kit (Part Number KT101)
− For convenient and easier ordering, the KT101 includes the TB02-KT
Do not install the Adapter in the machine until the software has been fully
installed.
1. Start Windows.
2. Insert the Sealevel Systems CD in to your CD drive.
3. If ‘Auto-Start’ is enabled for this drive the software will automatically
launch. Otherwise, point your browser to the ‘Index.htm’ on the root
directory of the CD
4. Select ‘Install Software’.
5. Select the Part Number for your adapter from the listing.
6. Select ‘Windows 98/ME/NT/2000/XP’. The setup file will automatically
detect the operating environment and install the proper components. Next
(depending on your browser) select the ‘Run this program from its current
location’ or ‘Open’ option. Follow the information presented on the screens
that follow.
7. A screen may appear with the declaration: “The publisher cannot be
determined due to the problems below: Authenticode signature not found.”
Please select the ‘Yes’ button and proceed with the installation. This
declaration simply means that the Operating System is not aware of the
driver being loaded. It will not cause any harm to your system.
8. During setup the user may specify installation directories and other
preferred configurations. This program also adds entries to the system
registry that are necessary for specifying the operating parameters for each
driver. An uninstall option is also included to remove all registry/INI file
entries from the system.
Windows NT Card Installation: After accomplishing the above steps, bring up the
Control Panel and double-click on the SeaIO Devices icon. To install a new card,
click "Add Port". Repeat this procedure for as many SeaIO cards as you wish to
install.
Sealevel’s SeaI/O software is provided to assist in the development of reliable
applications for the Sealevel Systems family of digital I/O adapters. Included on the
SeaI/O CD are driver functions for use in accessing the I/O as well as helpful
samples and utilities.
Programming for Windows
The SeaI/O API (Application Programmer Interface) provides a variety of useful
high-level function calls implemented in a Windows dynamic link library (DLL).
The API is defined in the help file (Start/Programs/SeaIO/SeaIO Help) under
“Application Programmers Interface”. This help file also includes detailed
information dealing with installation / removal of the software and information
about latency, logic states, and device configuration.
For C language programmers we recommend using the API to access the REL-
16.PCI. If you are programming in Visual Basic, using the ActiveX control
included with SeaI/O is advised.
Samples and Utilities
A variety of sample programs and utilities (both executable and source code) are
included with SeaI/O. Further documentation on these samples can be found by
selecting “Start/Programs/SeaIO/Sample Application Description”. Information
about where the files are physically stored on your disk is also included in this same
file.
Programming for Linux
SeaI/O for Linux consists of two major parts: a kernel moduleand a library. The
kernel module is a simple IO pass-through device, allowing the library to handle the
more sophisticated functions provided to SeaI/O users. It is provided in a ‘tarball’
format and can easily be compiled and included in the kernel build.
Digital I/O Interface
The REL-16.PCI provides two parallel reed relay output ports. The ports are
organized as ports A, B, C, and D. In order to maintain compatibility with the
existing ISA interface adapter (Sealevel Item# 3095), ports C and D (Base address+2
and 3) are the reed relay output port addresses.
Output Ports (Reed Relay)
Reed relays provide very high quality, long life, low current (10 Watt maximum),
dry contact switch closures. Reed relays are not suited for high current applications,
and can be destroyed by inductive load switching, where a spark occurs across the
contacts internally. The relays are normally open, and close when energized.
In systems where the user’s program has direct access to the hardware (i.e. DOS) the
table below gives the mapping and functions that the REL-16.PCI provides.
Function
Available
A Base + 0 Unused
B Base + 1 Unused
R/W C Base + 2 Output Port
R/W D Base + 3 Output Port
The relay ports return the ones complement of the value that is currently being used
to drive the relays. When using the API the actual value is returned not the
complement of the value.
Writing the Outputs:
The output ports are the only ports that can be written. The relays on a standard
REL-16.PCI are normally open. To close a relay a one must be written to the
appropriate bit.
16 SPST relays
DB-37 Male connector
Highly reliable 10 VA DIP reed relays
Multiple adapters can reside in same computer
PCI 2.1 Bus compatible
Specifications
Output Relays
Contact Max Power Rating: 10 W
Contact Voltage Maximum: 100 VDC/VAC
Contact Current Maximum: .5A AC/DC RMS
Contact Resistance, Initial: .15 Ω
Rated Life:
• Low Load: 200 Million Closures
• Maximum Load: 100 Million Closures
Contact Speed:
• Operate: .5 mS
• Release: .5 mS
• Bounce: .5 mS
Maximum Operating Speed: 600 Hz
Temperature Range
Operating: 0°C – 70°C
Storage: -50°C – 105°C
Power Requirements
+5VDC @ 360 mA
Physical Dimensions
PCB Length: 5.00” (12.700 cm)
PCB Height: 3.90” (9.906 cm, including Gold fingers)
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are
100% electrically tested. These printed circuit boards are solder mask over bare
copper or solder mask over tin nickel.
Following these simple steps can eliminate most common problems.
1. Install software first. After installing the software then proceed to adding the
hardware. This places the required installation files in the correct locations.
2. Read this manual thoroughly before attempting to install the adapter in your
system.
3. Use Device Manager under Windows to verify proper installation.
4. Use the SeaIO Control Panel applet or the Device Manager’s property page for
card identification and configuration.
5. If these steps do not solve your problem, please call Sealevel Systems’ Technical
Support, (864) 843-4343. Our technical support is free and available from 8:00AM5PM Eastern Time Monday through Friday. For email support contact
Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance
is still needed please see below.
When calling for technical assistance, please have your user manual and current
adapter settings. If possible, please have the adapter installed in a computer ready to
run diagnostics.
Sealevel Systems provides an FAQ section on its web site. Please refer to this to
answer many common questions. This section can be found at
http://www.sealevel.com/faq.asp
Sealevel Systems maintains a Home page on the Internet. Our home page address is
http://www.sealevel.com
available via our FTP site that can be accessed from our home page.
Technical support is available Monday to Friday from 8:00 a.m. to 5:00 p.m. eastern
time. Technical support can be reached at (864) 843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL
SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED.
AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL
SYSTEMS AND REQUESTING A RETURN MERCHANDISE
AUTHORIZATION (RMA) NUMBER.
. The latest software updates, and newest manuals are
FCC - This equipment has been tested and found to comply with the limits for Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in such case the user will be required to correct the interference at the
users expense.
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive
(89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European
Commission.
To obey these directives, the following European standards must be met:
EN55022 Class A - “Limits and methods of measurement of radio interference
characteristics of information technology equipment”
EN55024 – “Information technology equipment Immunity characteristics Limits and
methods of measurement”.
EN60950 (IEC950) - “Safety of information technology equipment, including
electrical business equipment”
Warning
This is a Class A Product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures to prevent or correct the interference.
Always use cabling provided with this product if possible. If no cable is provided or
if an alternate cable is required, use high quality shielded cabling to maintain
compliance with FCC/EMC directives.
Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime
Warranty that is standard on all Sealevel manufactured products. We are able to
offer this warranty due to our control of manufacturing quality and the historically
high reliability of our products in the field. Sealevel products are designed and
manufactured at its Liberty, South Carolina facility, allowing direct control over
product development, production, burn-in and testing.
Sealevel Systems, Inc. (hereafter "Sealevel") warrants that the Product shall conform
to and perform in accordance with published technical specifications and shall be
free of defects in materials and workmanship for life. In the event of failure,
Sealevel will repair or replace the product at Sealevel's sole discretion. Failures
resulting from misapplication or misuse of the Product, failure to adhere to any
specifications or instructions, or failure resulting from neglect or abuse are not
covered under this warranty.
Warranty service is obtained by delivering the Product to Sealevel and providing
proof of purchase. Return authorization must be obtained from Sealevel Systems
before returned merchandise will be accepted. Authorization is obtained by
calling Sealevel Systems and requesting a Return Merchandise Authorization
(RMA) number. The Customer agrees to insure the Product or assume the risk of
loss or damage in transit, to prepay shipping charges to Sealevel, and to use the
original shipping container or equivalent. Warranty is valid only for original
purchaser and is not transferable.
Trademarks
Sealevel Systems assumes no liability for any damages, lost profits, lost savings or
any other incidental or consequential damage resulting from the use, misuse of, or
inability to use this product. Sealevel Systems will not be liable for any claim made
by any other related party.
This warranty applies to Sealevel manufactured Product. Product purchased through
Sealevel but manufactured by a third party will retain the original manufacturer's
warranty.
Technical Support is available Monday - Friday from 8 a.m. to 5 p.m. Eastern time
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this
manual are the service mark, trademark, or registered trademark of the respective
company.