The Sealevel Systems SeaLINK+8/232.RJ (Item# 2804) is a USB device that equips
the PC with eight RS-232 Asynchronous serial ports that support TX, RX, RTS, and
CTS and data rates up to 115.2K baud. The 2804 is housed in an attractive plastic
enclosure with a high-retention USB type "B" connector that prevents accidental
disconnection of the included USB cable.
The 2804 is USB bus powered, so no external power supply is required. For
conveniently powering serial peripherals, ordering options allow an external power
source up to be connected to a DC jack on the rear of the unit. The supplied power is
fused and connected to pin 5 on each of the eight RJ45 connectors.
The SeaLINK+8/232.RJ is designed to be used with a variety of Operating Systems
including Windows 98/ME/2000/XP. The SeaCOM API (Application Programmer
Interface) included on CD with the SeaLINK+8/232.RJ provides a variety of useful
high-level function calls implemented as a Windows dynamic link library (DLL). In
addition to the API, SeaCOM includes sample code and utilities to simplify software
development.
The SeaLINK+8/232.RJ is shipped with the following items. If any of these items is
missing or damaged please contact Sealevel for replacement.
Item# 2804 – SeaLINK+8/232.RJ USB 8-Port Serial Device
Item# CA179 – 72” USB ‘A’ to ‘B’ Device Cable
Item# LB116 – RS-232 RJ45 Serial Loopback
Sealevel SeaCOM Software CD
Optional Items
Depending upon your application, you are likely to find one or more of the
following items useful for interfacing the SeaLINK+8/232.RJ. All items can be
purchased from our website (http://www.sealevel.com) or by calling 864-843-4343.
DB9 Male to RJ45 Modular Adapter (Item# RJ9P-232)
Preconfigured for use with the SeaLINK+8/232.RJ, this modular adapter
converts the RJ45 RS-232 pinout from the SeaLINK+8/232.RJ to a DB9 male
RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial
port up to 50 feet away from the SeaLINK+8/232.RJ.
DB25 Male to RJ45 Modular Adapter (Item# RJ25P-232)
Preconfigured for use with the SeaLINK+8/232.RJ, this modular adapter
converts the RJ45 RS-232 pinout from the SeaLINK+8/232.RJ to a DB25 male
RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial
port up to 50 feet away from the SeaLINK+8/232.RJ.
DB9 Male to RJ45 Modular Adapter (Item# RJ9P8)
The RJ9P8 includes an RJ45 connector and converts it to a DB9 Male connector,
which allows the use of standard twisted pair cabling. The RJ9P8 ships
unassembled and can be configured for virtually any pin out.
DB25 Male to RJ45 Modular Adapter (Item# RJ25P8)
The RJ25P8 includes an RJ45 connector and converts it to a DB25 Male
connector, which allows the use of standard twisted pair cabling. The RJ25P8
ships unassembled and can be configured for virtually any pin out.
USB ‘A’ to ‘A’ Extension Cable, 3 Meters in Length (Item# CA214)
The CA214 is a fully rated USB extension cable that allows adding 3 meters
(USB maximum of 5 meters) to any existing USB cable. The cable has a type ‘A’
male connector on one end and a type ‘A’ female connector on the other end.
RJ45 Patch Cable, 7’ in Length (Item# CA246)
Standard 7’ CAT5 patch cable with one-to-one pinout.
RJ45 Patch Cable, 10’ in Length (Item# CA247)
Standard 10’ CAT5 patch cable with one-to-one pinout.
Do not connect the device to a USB port until the software has been fully
installed.
1. Start Windows.
2. Insert the Sealevel Systems CD in to your CD drive.
3. If ‘Auto-Start’ is enabled for this drive the software will automatically launch.
Otherwise, point your browser to the ‘Index.htm’ on the root directory of the CD
4. Select ‘Install Software’.
5. Select the Part Number for your adapter from the listing.
6. Select ‘Windows 98/ME/2000/XP’. The setup file will automatically detect the
operating environment and install the proper components. Next (depending on
the OS version) select the ‘Run this program from its current location’ or ‘Open’
option. Follow the information presented on the screens that follow.
7. A screen may appear with the declaration: “The publisher cannot be determined
due to the problems below: Authenticode signature not found.” Please select the
‘Yes’ button and proceed with the installation. This declaration simply means
that the Operating System is not aware of the driver being loaded. It will not
cause any harm to your system.
8. During setup the user may specify installation directories and other preferred
configurations. This program also adds entries to the system registry that are
necessary for specifying the operating parameters for each driver. An uninstall
option is also included to remove all registry/INI file entries from the system.
Windows NT Note: Windows NT is not USB aware and thus cannot support this
device.
3rd Party Software Support
Third party software support for many HMI/MMI and other process control software
is included on the product installation CD. For the most up to date information on
third party software support, please visit
http://www.sealevel.com/thirdpartysoftware.asp.