Impulse 2106 User Manual

SeaLink+422
Users Manual
Part Number 2106
Sealevel Systems, Inc. Telephone: 864.843.4343 PO Box 830 Fax: 864.843.3067 Liberty, SC 29657 USA www.sealevel.com
INTRODUCTION........................................................................................................................ 1
OVERVIEW .............................................................................................................................................. 1
WHATS INCLUDED................................................................................................................................. 1
I
NSTALLATION......................................................................................................................... 1
WINDOWS 98/ME/2000/XP INSTALLATION............................................................................................1
PHYSICAL INSTALLATION........................................................................................................................ 1
TECHNICAL DESCRIPTION....................................................................................................... 2
FEATURES ............................................................................................................................................... 2
CONNECTOR PIN ASSIGNMENTS (DB-9 MALE)....................................................................................... 2
SPECIFICATIONS ......................................................................................................................3
ENVIRONMENTAL SPECIFICATIONS .........................................................................................................3
MANUFACTURING ................................................................................................................................... 3
POWER CONSUMPTION............................................................................................................................3
APPENDIX A - TROUBLESHOOTING.........................................................................................4
APPENDIX B - HOW TO GET ASSISTANCE ..............................................................................4
APPENDIX C RS-422 ELECTRICAL INTERFACE................................................................... 5
APPENDIX D - ASYNCHRONOUS COMMUNICATIONS ..............................................................5
APPENDIX E MEASURED DRAWING ..................................................................................... 6
WARRANTY..............................................................................................................................7
© Sealevel Systems, Inc. SL9094 Revision 7/2006
Sealevel Systems, Incorporated. All rights reserved.
Introduction and Installation

Introduction

Overview
The Sealevel Systems SeaLINK+422 equips the PC with 1 USB to RS-422 Asynchronous serial port providing a versatile interface for common RS-422 needs. The SeaLINK+422 connects through the PC’s external USB port, so it does not require opening the computer case. Resources such as IRQs and I/O addresses are also not utilized. It does require a system that supports USB in hardware and operating system.
What’s Included
The SeaLINK+422 is shipped with the following items. If any of these items is missing or damaged, contact the supplier.
SeaLINK+422 USB to RS-422 cable
Sealevel Software CD

Installation

Windows 98/ME/2000/XP Installation
Do not connect the Adapter to the machine until the software has been fully installed.
1. Start Windows.
2. Insert the Sealevel Systems CD in to your CD drive.
3. If ‘Auto-Start’ is enabled for this drive the software will automatically launch. Otherwise, point your
browser to the ‘Index.htm’ on the root directory of the CD
4. Select ‘Install Software’.
5. Select the Part Number for your adapter from the listing.
6. Select ‘Windows 98/ME/2000/XP’. The setup file will automatically detect the operating environment and
install the proper components. Next (depending on the OS version) select the ‘Run this program from its current location’ or ‘Open’ option. Follow the information presented on the screens that follow.
7. A screen may appear with the declaration: “The publisher cannot be determined due to the problems
below: Authenticode signature not found.” Please select the ‘Yes’ button and proceed with the installation. This declaration simply means that the Operating System is not aware of the driver being loaded. It will not cause any harm to your system.
8. During setup the user may specify installation directories and other preferred configurations. This program
also adds entries to the system registry that are necessary for specifying the operating parameters for each driver. An uninstall option is also included to remove all registry/INI file entries from the system.
Windows NT Note: Windows NT is not USB aware and thus cannot support the adapter.
Physical Installation
The SeaLINK+422 can be connected to any Upstream Type “A” port either at the PC host or an Upstream Hub, and since it is hot pluggable, there is no need to power down your computer prior to installation. The SeaLINK+422 requires no user hardware configuration. Once you have installed the software simply plug the USB cable into an available USB port. The drivers that were installed durin g setup will auto matically be used to conf igure the ad apter. You should see one or more “New Hardware Found” windows, indicating the actual device being created.
Sealevel Systems SeaLINK+422 Page 1