Introduction and Installation
Introduction
Overview
The Sealevel Systems SeaLINK+422 equips the PC with 1 USB to RS-422 Asynchronous serial port providing a
versatile interface for common RS-422 needs. The SeaLINK+422 connects through the PC’s external USB port, so
it does not require opening the computer case. Resources such as IRQs and I/O addresses are also not utilized. It
does require a system that supports USB in hardware and operating system.
What’s Included
The SeaLINK+422 is shipped with the following items. If any of these items is missing or damaged, contact the
supplier.
• SeaLINK+422 USB to RS-422 cable
• Sealevel Software CD
Installation
Windows 98/ME/2000/XP Installation
Do not connect the Adapter to the machine until the software has been fully installed.
1. Start Windows.
2. Insert the Sealevel Systems CD in to your CD drive.
3. If ‘Auto-Start’ is enabled for this drive the software will automatically launch. Otherwise, point your
browser to the ‘Index.htm’ on the root directory of the CD
4. Select ‘Install Software’.
5. Select the Part Number for your adapter from the listing.
6. Select ‘Windows 98/ME/2000/XP’. The setup file will automatically detect the operating environment and
install the proper components. Next (depending on the OS version) select the ‘Run this program from its
current location’ or ‘Open’ option. Follow the information presented on the screens that follow.
7. A screen may appear with the declaration: “The publisher cannot be determined due to the problems
below: Authenticode signature not found.” Please select the ‘Yes’ button and proceed with the installation.
This declaration simply means that the Operating System is not aware of the driver being loaded. It will not
cause any harm to your system.
8. During setup the user may specify installation directories and other preferred configurations. This program
also adds entries to the system registry that are necessary for specifying the operating parameters for each
driver. An uninstall option is also included to remove all registry/INI file entries from the system.
Windows NT Note: Windows NT is not USB aware and thus cannot support the adapter.
Physical Installation
The SeaLINK+422 can be connected to any Upstream Type “A” port either at the PC host or an Upstream Hub, and
since it is hot pluggable, there is no need to power down your computer prior to installation. The SeaLINK+422
requires no user hardware configuration. Once you have installed the software simply plug the USB cable into an
available USB port. The drivers that were installed durin g setup will auto matically be used to conf igure the ad apter.
You should see one or more “New Hardware Found” windows, indicating the actual device being created.
Sealevel Systems SeaLINK+422 Page 1
Technical Description
Technical Description
The SeaLINK+422: utilizes a USB UART. This chip features programmable baud rate, data format, 128 byte Dual
Port TX Buffer, and 384 byte Dual Port RX Buffer. The RS-422 transceiver supports data rates up to 921.6K baud.
Features
• Hot-Pluggable device
• Does not require opening the case
• No system resources are required (i.e. I/O ports or IRQs)
Connector Pin Assignments (DB-9 Male)
Signal Name Pin # Mode
RX+ Receive Positive 1 Input
RX- Receive Negative 2 Input
TX+ Transmit Positive 4 Output
TX- Transmit Negative 3 Output
GND Ground 5
NC 6,7,8,9
Sealevel Systems SeaLINK+422 Page 2
Specifications
Specifications
Environmental Specifications
Specification Operating Storage
Temperature
Range
Humidity Range
0º to 70º C
(32º to 158º F)
10 to 90% R.H.
Non-Condensing
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested. These
printed circuit boards are solder mask over bare copper or solder mask over tin nickel.
Power Consumption
Supply line
Rating
+5 VDC
70 mA
-50º to 105º C
(-58º to 221º F)
10 to 90% R.H.
Non-Condensing
Sealevel Systems SeaLINK+422 Page 3
Appendix A & B
Appendix A - T roubleshooting
Serial Utility test software is supplied with the Sealevel Systems adapter and should be used in the troubleshooting
procedures. Using this software and following these steps, most common problems can be eliminated.
1. If your adapter isn’t working, first check to make sure that USB support is enabled in the System BIOS and it is
functioning properly in the operating system. This can be done by using the Windows Device Manager.
2. Ensure that the Sealevel Systems software has been installed on the machine so that the necessary files are in
place to complete the installation.
Appendix B - How To Get Assistance
Please refer to Troubleshooting Guide prior to calling Technical Support.
1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed
please see below.
2. When calling for technical assistance, please have your user manual and current adapter settings. If
possible, please have the adapter installed in a computer ready to run diagnostics.
3. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many
common questions. This section can be found at http://www.sealevel.com/faq.asp
4. Sealevel Systems maintains a web page on the Internet. Our home page address is
http://www.sealevel.com
site.
5. Technical support is available Monday to Friday from 8:00 a.m. to 5:00 p.m. eastern time. Technical
support can be reached at (864) 843-4343.
Return Authorization Must Be Obtained From Sealevel Systems Before Returned Merchandise Will Be
Accepted. Authorization Can Be Obtained By Calling Sealevel Systems And Requesting A Return
Merchandise Authorization (RMA) Number.
. The latest software updates, and newest manuals are available via our web
.
Sealevel Systems SeaLINK+422 Page 4
Appendix C & D
r
Appendix C – RS-422 Electrical Interface
The RS-422 specification defines the electrical characteristics of balanced voltage digital interface circuits. RS-422
is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differential
interface, logic levels are defined by the difference in voltage between a pair of outputs or inputs. In contrast, a
single ended interface, for example RS-232, defines the logic levels as the difference in voltage between a single
signal and a common ground connection. Differential interfaces are typically more immune to noise or voltage
spikes that may occur on the communication lines. Differential interfaces also have greater drive capabilities that
allow for longer cable lengths. RS-422 is rated up to 10 Megabits per second and can have cabling 4000 feet long.
RS-422 also defines driver and receiver electrical characteristics that will allow 1 driver and up to 32 receivers on
the line at once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not define a physical connector.
Appendix D - Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that
assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop
bits) are pre-defined and must correspond at both the transmitting and receiving ends.
Asynchronous communications is the standard means of serial data communication for PC compatibles and PS/2
computers. The original PC was equipped with a communication or COM: port that was designed around an 8250
Universal Asynchronous Receiver Transmitter (UART). This device allows asynchronous serial data to be
transferred through a simple and straightforward programming interface. Character boundaries for asynchronous
communications are defined by a starting bit followed by a pre-defined number of data bits (5, 6, 7, or 8). The end
of the character is defined by the transmission of a pre-defined number of stop bits (usually 1, 1.5 or 2). An extra bit
used for error detection is often appended before the stop bits.
Idle state of
line
1
0
5 to 8 Data Bits
Odd, Even
or
Unused
P
BIT
STOP
Remain Idle o
next start bit
1
1.5
2
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or
corrupted during transmission. There are several methods for implementing a parity check to guard against data
corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors
on the data stream. This is refereed to as (N)o parity. Because each bit in asynchronous communications is sent
consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped
(framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate
and communication parameters for asynchronous communications have to be the same at both the transmitting and
receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits
(i.e. 9600,N,8,1).
Sealevel Systems SeaLINK+422 Page 5
Appendix E – Measured Drawing
Appendix E – Measured Drawing
4-40 NU T S
SHIELDED DB -9
DB-9 Male
THUMBSCREW S
CONNECTOR 4-40
P2
P2
DB-9 MALE
5' (+/- 1")
4' 6"(+0", - 6")6"(+ 6", -0")
9
PIN 1
4
P1
PIN 1
P1
USB Type A Plug
Sealevel Systems SeaLINK+422 Page 6
Warranty
Warranty
Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime
Warranty that is standard on all Sealevel manufactured products. We are able to offer
this warranty due to our control of manufacturing quality and the historically high
reliability of our products in the field. Sealevel products are designed and
manufactured at its Liberty, South Carolina facility, allowing direct control over
product development, production, burn-in and testing.
Sealevel Systems, Inc. (hereafter "Sealevel") warrants that the Product shall conform to and perform in accordance
with published technical specifications and shall be free of defects in materials and workmanship for life. In the
event of failure, Sealevel will repair or replace the product at Sealevel's sole discretion. Failures resulting from
misapplication or misuse of the Product, failure to adhere to any specifications or instructions, or failure resulting
from neglect or abuse are not covered under this warranty.
Warranty service is obtained by delivering the Product to Sealevel and providing proof of purchase. Return
authorization must be obtained from Sealevel Systems before returned merchandise will be accepted.
Authorization is obtained by calling Sealevel Systems and requesting a Return Merchandise Authorization
(RMA) number. The Customer agrees to insure the Product or assume the risk of loss or damage in transit, to
prepay shipping charges to Sealevel, and to use the original shipping container or equivalent. Warranty is valid only
for original purchaser and is not transferable.
Sealevel Systems assumes no liability for any damages, lost profits, lost savings or any other incidental or
consequential damage resulting from the use, misuse of, or inability to use this product. Sealevel Systems will not
be liable for any claim made by any other related party.
This warranty applies to Sealevel manufactured Product. Product purchased through Sealevel but manufactured by a
third party will retain the original manufacturer's warranty.
Technical Support is available from 8 a.m. to 5 p.m. Eastern time.
Monday - Friday
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark,
trademark, or registered trademark of the respective company.
SeaLINK+422 is a trademark of Sealevel Systems, Incorporated.
Sealevel Systems SeaLINK+422 Page 7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.