ImproX XDT900-0-0-GB-XX Installation Manual

MODEL: XDT900-0-0-GB-XX
ImproX
DT
Door Terminal
INSTALLATION
MANUAL
Manual ref number: XDT300-0-0-GB-01 Issue 2 July 2001
© July 2001 Impro Technologies
Data subject to change without notice
Page 2
R
P O Bo x 15407 Westmead South Africa 3608
47 Gillitts Roa d Pinetown South Africa 3610
(031)
700-1087
(031)
700-151 1
impro@impro.net
(e-mail)
IMPORTANT NOTICE
Although all efforts have been made to make this manual as accurate as possible, Impro Technologies (Pty) Ltd does NOT accept any liability for errors or omissions. The data contained in this manual supersedes any other information published on the product. We further reserve the right to amend or improve the equipment and manual without notice.
GUARANTEE / WARRANTY
Impro Technologies (Pty) Ltd warrants that the Products furnished under this agreement will be free from material defects in material and workmanship for a period of three years from the date of shipment. The Customer shall provide notice to Impro Technologies (Pty) Ltd of each such defect within one week after the Customer's discovery of such defect. The sole obligation and liability of Impro Technologies (Pty) Ltd under this warranty shall be to repair or replace at Impro's sole discretion, but without cost to the Customer, the product or part which is so defective and as to which such notice is given.
Upon request by Impro Technologies (Pty) Ltd, the product or part claimed to be defective shall immediately be returned at the Customer's expense to Impro Technologies (Pty) Ltd. Replaced or repaired products or parts will be shipped to the Customer a t the expense of Im pr o Technologies (Pty) Ltd.
There shall be no warranty or liability for any products or pa rts which have been subject to misuse, accident, negligence, failure of electric power or modification by the Customer without Impro Technologies (Pty) Ltd written approval. Final determ ination of warranty eligibility shall be made by Impro Technologies (Pty) Ltd. If a warranty claim is considered invalid for any reason, the Customer will be charged for services performed and expenses incurred by Impro Technologies (Pty) Ltd in handling and shipping the returned item.
As to replacement parts supplied or repairs made during the original warranty period, the warranty period of the replacement or repaired part shall terminate with the termination of the warranty period with respect to the original product or part.
As Impro Technologies (Pty) Ltd has no control over where the product is used, or how it is installed, no liability for ANY consequential damages can be accepted, whether due to malfunction, design, deficiency, implementation or any cause whatsoever.
Impro Technologies does not guarantee interfacing compatibility of any of its equipment with any third-party equipment, regardless of any standards which may be applicable. Connecting third-party equipment to any Impro equipment may compromise the functionality of the Impro equipment and render it inoperative.
THE FOREGOING WARRANTY CONSTITUTES IMPRO TECHNOLOGIES (PTY) LTD SOLE LIABILITY AND THE CUSTOMERS SOLE REMEDY WITH RESPECT TO THE PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES, LIABILITIES AND REMEDIES EXCEPT AS THUS PROVIDED, IMPRO TECHNOLOGIES (PTY) LTD DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
This product is designed and manufactured by:
© July 2001 Impro Technologies
Data subject to change without notice
Page 3
CONTENTS
IMPORTANT NOTICE..............................................................................................2
GUARANTEE/WARRANTY........................................................................................2
INTRODUCTION.....................................................................................................4
SPECIFICATIONS....................................................................................................4
PHYSICAL SPECIFICATIONS.................................................................................4
ENVIRONMENTAL SPECIFICATIONS......................................................................4
ELECTRICAL SPECIFICATIONS..............................................................................5
OPERATOR INTERFACES......................................................................................6
IMPROX PROTOCOL.............................................................................................6
INSTALLATION INFORMATION................................................................................6
REQUIREMENTS ..................................................................................................6
POSITIONING THE UNIT......................................................................................6
INSTALLATION PROCEDURE ................................................................................7
CONNECTING THE UNIT ......................................................................................8
General ............................................................................................................8
Input Power Connections...................................................................................8
RS485 Communications Connections..................................................................8
Remote Reader Power Connections....................................................................8
Remote Reader Communications Connections.....................................................8
Jumper Settings................................................................................................8
Relay Outputs...................................................................................................8
BUS ACTIVITY LED INDICATORS.............................................................................9
ADDRESS ALLOCATION ..........................................................................................9
TYPES OF ADDRESSES.........................................................................................9
Fixed Address ...................................................................................................9
Address Allocation - ImproNet Systems ..............................................................9
Address Allocation - OEM Systems......................................................................9
RECORDING OF INSTALLATION INFORMATION ....................................................10
Installation Information .....................................................................................10
Entering Installation Information in the Host PC..................................................12
RELATED PRODUCTS..............................................................................................12
ORDERING INFORMATION......................................................................................13
APPLICABILITY OF THIS MANUAL ...........................................................................16
DIAGRAMS
Figure 1 : Relative location of significant components...............................................7
Figure 2 : Connections to the DT Terminal...............................................................11
Figure 3 : Arc suppression circuits ...........................................................................12
© July 2001 Impro Technologies
Data subject to change without notice
Page 4
INTRODUCTION
The Improx DT Door Terminal forms part of the ImproX family of access control equipment.
The unit provides two input sensors for door open/close sensing, and one relay for controlling door strikes or other equipment. The unit also provides 5 VDC and TTL communications for a Remote Reader such as the ImproX CR, KR, MR, KHR, MHR or connects to an Impro 4-Channel UHF Receiver.
The unit communicates with other ImproX units via an RS485 Terminal Bus connection. The Door Terminal is intended for indoor mounting only.
SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Dimensions : Length
Width Height
= = =
105 mm (4.14"). 116 mm (4.57"). 54 mm (2.13").
Weight : 115 g. (4.05 oz). Housing material : Aluminium. Colour : Black.
ENVIRONMENTAL SPECIFICATIONS
TEMPERATURE
Operating
: -25
o
C to +70oC (- 13oF to +158oF).
Storage
: -40
o
C to +80oC (-40oF to +176oF).
HUMIDITY RANGE : 0 to 95% relative humidity at 40
o
C (+104oF)
non-condensing.
EMC : EN55024. ELECTROSTATIC DISCHARGE : IEC6 1000-4-2. ELECTRICAL FAST TRANSIENTS : IEC6 1000-4-4. SURGE IMMUNITY : IEC6 1000-4-5. RADIATED SUSCEPTIBILITY : IEC6 1000-4-3. CONDUCTED SUSCEPTIBILITY : IEC6 1000-4-6. DUST AND SPLASH RESISTANCE : This unit is manufactured in accordance with a
dust and splash environment similar to that required for a rating of IP30.
DROP ENDURANCE : 1 m drop (in packaging).
© July 2001 Impro Technologies
Data subject to change without notice
Page 5
ELECTRICAL SPECIFICATIONS
POWER REQUIREMENTS
Voltage
: 8 V to 36 V DC.
Current
: 90 mA at 8V – relay and indic ators all off, with
a Remote Reader attached. 170 mA at 8 V – relay and indicators all on,
with a Remote Reader attached.
NOTE :
The various Remote Readers draw different amounts of current. These figures represent the maximum current drawn based on the currently available Remote Readers.
Permissable input supply
ripple voltage (maximum)
: 1 V
PP
50 Hz.
POWER INPUT PROTECTION : Reverse polarity and over-voltage protection. RELAYS : A single relay is provided. DIGITAL INPUTS
Type
: 2 x dry contact inputs.
Protection Range
: +80 V and –80 V single pulse.
+36 V and –30 V continuous.
RELAY OUTPUT : SPDT; N/O, N/C and Common contacts. RELAY CONTACT RATINGS : 10 A at 28 V DC.
5 A at 220 V AC.
ANTI-TAMPER SWITCH : Detects the opening of the unit enclosure. RAM : 2 Kbytes. FLASH ROM : 128 Kbytes. EEPROM : 2 Kbits. TERMINAL BUS PORT
Baud rates
: 1 200, 2 400, 4 800, 9 600, 19 200, 28 800, 38
400, 57 600 and 76 800 selectable via the communications protocol.
Default baud rate
: Factory-set to 38 400.
Data format
: 8 data bits, no parity, 1 stop bit.
Electrical Interface
: RS485, ASCII with 16-bit CRC checking.
Communications protocol
: ImproX Secure Communications Protocol.
Default mode
: Receive (Slave Mode).
Loading...