SPECIFICATIONS
CSN Read Capability ...................
Slim Tags, Omega Tags, Impro Trinary Tags
(1074 and 2074), Philips HITAG™ 1, Philips HITAG™ 2, HID Tags (H10301, H10302 and H10304), ISO 15693-2 iClass Tags, ISO 18092 FeliCa Tags and ISO 14443A
MIFARE® Tags.
NOTE: HID, FeliCa and MIFARE® are
registered trademarks of HID Global Corporation (an ASSA ABLOY Group Brand), The Sony Corporation and Koninklijke Phillips Electronics N.V. respectively.
Working Environment
MDK901/HRW900 MDR901/HRW901
HRW903/HRW902.........................
Designed to work in an indoor or outdoor
environment similar to IP54. These models are, therefore, sealed (conformal coated) against water.
HRK900 & HRK901 .......................
Designed to work in an indoor environment
similar to IP20. These models are NOT sealed against water and should not be exposed to
rain or splashes.
Installation
Please consult the instructions under Installation Information, on page 4.
Blank Space
MDR300-0-0-GB-08
July 2015
Page 2
Input Voltage Rating ....................
8 V DC to 14 V DC, polarity sensitive.
NOTE: If the Multi-discipline Reader’s Input
Voltage rises or falls outside that specified above; the Reader emits a continuous beep sound. The beep sound consists of a 1-second beep followed by a 1-second interbeep pause.
Power Requirements
Current (mA)
Power (W)
Supply Voltage 12 V DC all
Indicators on...........................
100
1.2
Wiegand Bus
Electrical Interface ..................
‘0’ and ‘1’ Data streams.
Data Format ...........................
Tag information: 44-bit or 26-bit Wiegand. Key information: 26-bit Wiegand only.
Inputs
Quantity ..................................
4.
Type .......................................
Dry Contact.
Function .................................
Operation of the Buzzer, LED and Scanner Inhibit.
Protection Range ...................
+15 V Continuous.
Buzzer ...........................................
4 kHz piezo-electric single volume, single tone.
HRK901 and MDK901/HRW901/HRW903 models only
Ke ypad ..........................................
12 Alphanumeric keys.
Keypad Durability ........................
Maximum 200 000 key presses.
PIN-codes .....................................
5 Digit codes in the range 00000 to 65535. 4 Digit codes in the range 0000# to 9999#.
Blank Space
MDR300-0-0-GB-08
July 2015
Page 3
Status Indicators
Status LED .............................
Tri-coloured Red, Green or Amber (Default) (externally visible).
Optical Anti-tamper
(MDR901/HRW900, MDK900/HRW901,
HRW903/HRW902) ................
Open Collector Output on Purple Line.
GND reference on Grey Line.
Mechanical Anti-tamper
(HRK900, HRK901) ................
Open Collector Output on Purple Line.
GND reference on Grey Line.
NOTE: In OEM applications, connect the
Purple and Grey wires to a Dry Contact Input. In Access Portal Systems (connecting to a Wiegand Module clustered with a Cluster Controller Module), and on IXP20 (iTRT version) and IXP220 Systems (when connected direct to the Controller or via the Impro iTRT) it is unnecessary to connect these lines as the Software handles the Anti-tamper.
Blank Space
MDR300-0-0-GB-08
July 2015
Page 4
INSTALLATION INFORMATION
Accessories
Find the following when unpacking the Multi-discipline Reader:
Either an Impro (MDR) Multi-discipline Reader (MDR901-5-0-GB-XX/HRW900-5-0- GB-XX) housed in an ABS Plastic and 304 Stainless Steel housing. The Multi­discipline Reader consists of a Front Cover assembly and a Backing Plate (the Backing Plate is attached with a Hexagonal Screw (M3 x 8 mm)).
Or an Impro (MDK) Multi-discipline Keypad Reader (MDK901-5-0-GB-XX/ HRW901-5-0-GB-XX) housed in an ABS Plastic and 304 Stainless Steel housing.
OR a Multi-discipline Junction Box Reader ((HRK900-0-5-GB-XX) / Multi-discipline Junction Box Keypad Reader ((HRK901-0-5-GB-XX) housed in a Black, ABS Plastic housing.
The Multi-discipline Reader consists of a Front Cover assembly and a Backing Plate (the Backing Plate is attached with a Hexagonal Screw (M3 x 8 mm)).
One 2-Way Programming Pin.
An Allen Key (2 mm).
An extra Hexagonal Screw (M3 x 8 mm).
An extra Serial Number Label.
The Junction Box Reader consists of a Front Cover and a Backing Plate Assembly (the Front Cover is attached with a Combi Screw (6 mm x 2.2 mm)). The Backing Plate Assembly includes 1 m (3.28 ft) of 10-core, 6.2 mm cable.
One 2-way Programming Pin.
An extra Serial Number Label.
General
Remember the following when installing the Multi-discipline Readers:
Maximum Data Communications Distance
Install the Multi-discipline Readers no further than 150 m (164 yd) from the Host unit. The cable individual conductor may be AWG 20 to AWG 22 cross-sectional area should not be less than 0.644 mm
2
(0.0253 in2).
NOTE: You can expect a drop in read range on 13.56 MHz Tags if noise exists on
the Reader’s input supply. The following good wiring practices lessen noise introduction: Use a well shielded cable with a drain wire, ensure connection of the drain wire to a clean Earth point. Also, install cables away from high voltage cabling and other noise (that is wireless equipment, machinery and so on) sources.
MDR300-0-0-GB-08
July 2015
Page 5
Distance between Multi-discipline Readers
To avoid mutual interference, install the Multi-discipline Readers no closer than 500 mm (20 in) apart. Expect a drop in Tag read range where you install Multi­discipline Readers back-to-back (that is on either side of a wall).
Mounting the Multi-discipline Readers
CAUTION: Make certain that you mount the Readers on a vibration-free
surface.
CAUTION: You may install Multi-discipline Readers in an open environment.
To do this, apply a slanted strip of general-purpose, black, silicone based sealant between the mounting surface and the Backing Plate, above the cable entry point. An open environment refers to any environment affected by elements like rain or water.
Select the mounting position of the Multi-discipline Readers, considering accessibility, routing of wires and visibility of the externally visible LED.
Secure the Multi-discipline Readers to the mounting surface, using suitable screws and wall plugs, nuts and bolts or rivets.
Blank Space
MDR300-0-0-GB-08
July 2015
Page 6
ELECTRICAL CONNECTIONS
Connecting the Multi-discipline Reader
Figure 2 to Figure 7 show typical connections for the Multi-discipline Reader.
Figure 1: Multi-Discipline Reader connected to the Wiegand Reader Module
MDR300-0-0-GB-08
July 2015
Page 7
Figure 2: Multi-discipline Reader Connected to the Impro iTRT
MDR300-0-0-GB-08
July 2015
Page 8
Figure 3: Multi-discipline Reader Connected to the IXP20 Controller
MDR300-0-0-GB-08
July 2015
Page 9
Figure 4: Multi-discipline Reader Connected to the IXP220 Controller
MDR300-0-0-GB-08
July 2015
Page 10
Figure 5: Multi-discipline Reader Connected to the Impro MfT
MDR300-0-0-GB-08
July 2015
Page 11
Figure 6: Multi-discipline Reader Connected to the Impro TA or Impro iTA
MDR300-0-0-GB-08
July 2015
Page 12
Figure 7: Multi-discipline Reader Connected to the Impro RS or Impro RH
MDR300-0-0-GB-08
July 2015
Page 13
Configuring the Tag Frequency Mode
The Multi-discipline Readers offer three different Tag Frequency Modes. To select the Tag Frequency Mode, do the following:
1. Power up the Reader. On power up, you have 5 seconds in which to set the Tag Frequency Mode.
2. Present a Tag that matches your chosen Tag Frequency Mode:
Mode 1 (125 kHz): If you present a 125 kHz Tag for the full 5-second period, the Reader will only read 125 kHz Tags.
Mode 2 (13.56 MHz): If you present a 13.56 MHz Tag for the full 5-second period, the Reader will only read 13.56 MHz Tags.
Mode 3 (125 kHz and 13.56 MHz): If you present a 125 kHz Tag for 2 seconds followed by a 13.56 MHz Tag for 2 seconds, the Reader will read both 125 kHz and 13.56 MHz Tags. This is the default mode.
NOTE: If you do not present a Tag within the 5-second period, the Reader uses the
last known Tag Frequency Mode.
Setting the Output Mode (OEM Use Only)
The Multi-discipline Readers offer four different Output Mode Combinations. Select the Output Mode by doing the following:
1. On the back of the Multi-discipline Reader, locate and bridge the two stand-alone Pins using the 2-Way Programming Pin supplied.
2. Power up the unit, the number of beeps indicates the selected Output Mode:
Mode 1 (1 Beep): 26-bit, HID Normal.
Mode 2 (2 Beeps): 44-bit, HID Normal (Default).
Mode 3 (3 Beeps): 26-bit, HID Raw.
Mode 4 (4 Beeps): 44-bit, HID Raw.
NOTE: The 26-bit and the 44-bit refer to the output format of EMM and Impro
Trinary Tags. HID Tags output in either normal or 45-bit raw mode.
3. Remove the 2-Way Programming Pins once the mode is selected.
4. Clip the Front Cover onto the Backing Plate.
Wiegand 44-bit Protocol
Tags are reported using Wiegand 44-bit Protocol. An “EMM” Tag has an 8-bit User Code and a 32-bit Serial Number.
These are reported as follows:
The 8-bit User Code is reported in bits 1 to 8 of the Protocol.
The 32-bit Serial Number is reported in bits 9 to 40 of the Protocol.
Bits 41 to 44 of the Protocol are the exclusive OR of the preceding 40 bits taken 4
at a time.
HID Raw
In this Mode, the entire raw 45-bit HID Tag is output.
MDR300-0-0-GB-08
July 2015
Page 14
Wiegand 26-bit Protocol
Key Codes are reported as a 24-bit code consisting of an 8-bit Facility (or Site) Code, and a 16-bit binary representation of the Key Code.
The following format is used:
Bit 1 is the even parity over the first 13 bits.
Bits 2 to 9 are the 8-bit Facility Code for Key Codes.
Bits 10 to 25 are the 16-bit Key Code.
Bit 26 is the odd parity over the last 13 bits.
HID Normal
The number of bits to output is determined from the information in the tag and will vary between tags. The 26-bit or 44-bit selection does not impact on HID Tags.
Keypad Model Settings (MDK900/HRW901 & HRK901 only)
The 12-button Keypad is used to enter 5-digit PIN-codes in the range 00000 to 65535. Wiegand protocol constraints disallow PIN-codes from 65536 to 99999. In this case the Status LED turns Red and the Buzzer activates for 2 seconds.
The Reader can accept 1 to 4-digit PIN-codes by pressing the Hash Key (#) after you have entered the PIN-code.
Errors made while entering the PIN-code can be corrected by pressing the Star Key (*) followed by the correct PIN-code.
PIN code up to 5 digits with programmable facility code, output in 26-bit format.
Fixed length buffered keys from 1 – 11 output in hexadecimal format with optional
parity.
NOTE: The output of the PIN-code keypad information is in 26-bit Wiegand format.
Fixed Length Key Output Mode
Once the specified number of keys are pressed, all the buffered keys are output in hexadecimal format:
Key
Output
0
0000
1
0001
2
0010
3
0011
4
0100
5
0101
6
0110
7
0111
8
1000
9
1001
*
1010
#
1011
Table 1: Fixed Length Key Output Mode
MDR300-0-0-GB-08
July 2015
Page 15
Setting the Fixed Length Mode
The number of keys to be buffered and the parity option in the Fixed Length Mode is set as follows:
1. Press and hold down key '2' for 3 seconds. The Status LED enters a fast flash
Mode and emits a long beep.
2. Enter a 3 digit number followed by the Hash Key (#). The first 2 digits specify the
key buffer length and must be in the range 00 to 11 (eleven). The third digit must be a ‘0’ where there is no parity and ‘1’ where parity is added.
NOTE: If ‘00’ is entered for the key buffer length then the Key Mode reverts to PIN
Mode.
3. On acceptance of the setting, the Status LED changes to Green.
4. If the settings are rejected the Status LED changes to Red.
Single Key 8-bit Burst Mode
To select this mode, specify the Fixed Length Buffered Mode to be “018”. This mode reports each single key press as 8-bit code. Use Single Key 8-bit Burst Mode when using Multi-discipline Readers in PAC Mode or TAG+PIN Mode.
Key
Output
0
11110000
1
11100001
2
11010010
3
11000011
4
10110100
5
10100101
6
10010110
7
10000111
8
01111000
9
01101001
*
01011010
#
01001011
Table 2: Single Key 8-bit Burst Mode
Blank Space
MDR300-0-0-GB-08
July 2015
Page 16
Setting Single Key 8-bit Burst Mode
1. Press and hold down key '2' until the Reader beeps continuously.
2. Enter ‘018’ and finish by pressing the Hash Key (#).
3. On acceptance of the change, the Status LED will change to Green.
4. If the change is rejected the Status LED will change to Red.
Entering a Facility Code
A Facility Code only applies when PIN-codes are used. It is reported as part of the Wiegand code and can be used to link a set of Multi-discipline Readers to a particular Site.
A Facility Code can be entered into the Reader's memory. To set the Facility Code, do the following:
1. Press and hold down key '1' for 3 seconds. The Status LED will enter a fast flash
Amber Mode.
2. Enter the Facility Code in the range 0 to 255 and finish by pressing the Hash Key
(#).
3. On acceptance of the Facility Code the Status LED will briefly change to Green
and the Buzzer will sound.
4. If the Facility Code is rejected the Status LED will change to Red for a longer
period and the Buzzer will sound.
Power-on Self-test
The Power-on Self-test tests the RAM and Flash Checksums.
If any parameter in the Self-test fails, the Multi-discipline Reader emits a continuous beep for 2 seconds.
When the Multi-discipline Reader passes the Self-test, it emits two short beeps, each 200 ms in duration, separated by a 200 ms inter-beep pause.
When the Multi-discipline Reader is connected, check that the Status LED is illuminated Red (steady). This will confirm that the connection is correct and working.
Serial Number Label
1. Once the Multi-discipline Reader is installed, sketch a rough site plan.
2. Attach the Multi-discipline Reader’s loose Serial Number Label and the Terminal or
Controller’s Fixed Address Label, to the sketched site plan in the position of the Multi-discipline Reader.
The Multi-discipline Reader does not have its own Fixed Address. When connected to a Terminal or Controller the Multi-discipline Reader is assigned one of the available Fixed Addresses.
The Serial Number Label identifies the type of Multi-discipline Reader, and the Fixed Address Label (shipped with the Terminal or Controller) identifies the Fixed Addresses. Both these labels should be attached to the site plan to assist in identifying the hardware once an Auto-ID is performed.
MDR300-0-0-GB-08
July 2015
Page 17
GUARANTEE OR WARRANTY
This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net.
CE STATUS
Models
Status
MDK901/HRW900, MDR901/HRW901
User Notes
MDR300-0-0-GB-08
July 2015
Page 18
User Notes
MDR300-0-0-GB-08
July 2015
Page 19
User Notes
MDR300-0-0-GB-08
July 2015
Page 20
User Notes
This manual is applicable to the Impro Multi-discipline Readers:
HRW903-5-0-GB-XX / HRW902-5-0-GB-
XX
MDR901-5-0-GB-XX / HRW900-5-0-GB-XX
,
MDK900-5-0-GB-XX / HRW901-5-0-GB-XX,
HRK900-0-5-GB-XX, HRK901-0-5-GB-XX
.
(The last two digits of the Impro stock code indicate the issue status of the product.)
MDR300-0-0-GB-07 Issue 08 July 2015
Impro MDR\English Manuals\LATEST ISSUE\MDRRdr-
insm-en-08.docx
Loading...