The EPCglobal™-certified Speedway™ IPJ-R1000 reader is a stationary UHF Gen 2 RFID tag reader that provides network
connectivity between tag data and enterprise system software.
A key element of Impinj's GrandPrix™ RFID system solution, the Speedway reader is the first high-performance reader
designed from the ground up to support the EPCglobal Gen 2 standard in its entirety, including: the accommodation of 640
kbps tag-to-reader data rates, robust performance in dense-reader environments (without the requirement for network
synchronization), the elimination of ghost reads, and more. Combined with an extensible architecture that supports seamless
integration of field-upgradeable, third party application software, the Speedway reader is the most adaptable reader solution
available today.
This user guide provides instructions on how to install, connect, configure, operate, upgrade, and troubleshoot Speedway
readers. It assumes the user is familiar with appropriate networking facilities, the EPCglobal Gen 2 specification, and general
principles of RFID system management.
Important The user guide only covers readers having part numbers in the following format:
IPJ-R1000-USA-N-NN-NN-NNN, IPJ-R1000-EU1-N-NN-NN-NNN, and IPJ-R1000-AS1-N-NN-NN-N NN.
EPCglobal™ Dense-ReaderCertified
Blah, blah, blah
Blah, blah, blah
Blah, blah, blah
2
Page 3
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Federal Communications Commission (FCC) Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to ra dio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Consult the dealer or a qualified radio/TV technician for assistance
Caution Changes to this product or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment per FCC Part 15.
Industry Canada (IC) Compliance
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
This device has been designed to operate with the antenna(s) listed in section 2.5 and having a maximum gain of 6 dB.
Antennas not included in this list or having a gain greater than 6 dB are strictly prohibited for use with this device. The
required antenna impedance is 50 ohms.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (EIRP) is not more than that permitted for successful communication.
Note: The term “IC:” before the radio certification number only signifies that Industry of Canada technical specifications were
met.
CE Marking and European Economic Area (EEA)
RFID devices designed for use throughout the EEA must have a maximum radiated transmit power of 2W ERP in the
frequency range of 865.6–867.6 MHz. For other EEA restrictions on RFID device use, please refer to the Impinj Declaration of
Conformity (DoC) located at http://rfid-support.impinj.com
Before You Begin
!
WarningPlease read this document in its entirety before operating the Speedway reader, as serious personal injury or equipment damage may result from improper use.
Unauthorized opening of the Speedway reader enclosure voids the warranty.
3
Page 4
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table of Contents
1. Regions of Operation.............................................................................................................6
1.1. Operation in North America ...........................................................................................6
1.2. Operation in Europe.......................................................................................................6
1.3. Operation in Taiwan.......................................................................................................6
2. Setting Up the Speedway Reader .........................................................................................7
2.1. System and Equipment Requirements ..........................................................................7
2.3. Mounting the Speedway Reader....................................................................................9
2.4. Connecting Power .......................................................................................................10
2.5. Connecting the Antenna(s) ..........................................................................................10
2.5.1.FCC and Industry Canada................................................................................................................................10
7.5.1.Command Line Interface Upgrade..................................................................................................................29
7.5.4.Fallback to Previous Image ............................................................................................................................. 31
7.5.5.Query the Upgrade Status................................................................................................................................ 31
7.5.6.Background Execution of Image Management Commands............................................................................ 31
show Command............................................................................................................................................... 40
8.4.5.config system Command.................................................................................................................................52
8.5.1.show all Command.......................................................................................................................................... 53
8.5.5.show system Command................................................................................................................................... 67
8.6.2.transfer status Command.................................................................................................................................70
Appendix A Impinj Factory Default Configuration .......................................................................72
Appendix B Command Line Editing in Rshell .............................................................................73
Appendix C Power Supply Specifications ...................................................................................74
5
Page 6
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
1. Regions of Operation
The Speedway reader has been designed to work in various regions with differing frequency requirements. This document
covers operation in North America, Europe, and Taiwan.
Important In each region, the reader is locked to only operate in the specific frequencies listed in the respective frequency
plan tables (Table 1-1, Table 1-2, and Table 1-3).
1.1. Operation in North America
The FCC stipulates frequency hopping across the North American spectrum allocated to UHF RFID (902−928 MHz, with
hopping occurring between 902.75−927.25 MHz in 500 KHz steps).
Table 1-1 Frequency Plan for North America
Transmit Channel Number Center Frequency (MHz)
1 902.75
2 903.25
3 903.75
4 904.25
.
.
.
49 926.75
50 927.25
.
.
.
1.2. Operation in Europe
For European operation, the Speedway reader operates under EN 302-208 u sing listen-before-talk (LBT). An optional setting
allows use of a third-party controller for deployment where readers share channels. Consult the manufacturer of compatible
controllers for details on how to setup and deploy.
Table 1-2 Frequency Plan for Europe
Transmit Channel Number Center Frequency (MHz)
4 865.7
7 866.3
10 866.9
13 867.5
1.3. Operation in Taiwan
The Speedway reader supports the frequency plan listed in Table 1-3 for operation in Taiwan. The NCC stipulates frequency
hopping across the Taiwanese spectrum allocated to UHF RFID (9 22 -9 2 8 M Hz, wi t h hop pi n g occu rring between
922.25–927.75 MHz in 500 KHz steps).
Table 1-3 Frequency Plan for Taiwan
Transmit Channel Number Center Frequency (MHz)
1 922.25
2 922.75
.
.
.
11 927.25
12 927.75
.
.
.
6
Page 7
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
2. Setting Up the Speedway Reader
The Speedway reader unit requires a power supply module (CUI, Inc., P/N DTS240250UC-P11P-DB for North American
operation or DTS240250U-AC2-P11P-DB for European Union operation) with 24 VDC output. See Appendix C for the
power supply module specifications, or visit www.cui.com
!
Warning The use of any other power supply module may cause damage to the reader.
2.1. System and Equipment Requirements
Table 2-1summarizes the supported operating environments.
Table 2-1 Operating Environments
Interface Protocol Recommended Tools
Web Interface HTTP Compatible with common browsers IE (6+), Firefox (1.5+), and
Remote Login SSH/Telnet Putty SSH or Telnet Terminal
Serial RS-232 Hyperterminal Minicom N/A
The components and accessories detailed below are required in order to ensure compliance with the Speedway reader. It is the
responsibility of the user or professional installer to provide and properly use all these components and accessories:
•A computer running Windows 2000 (or higher), XP, or Linux PC, which has:
- An available RS-232 serial port (required only if host system does not support DHCP)
- An Ethernet port
•HTTP browser that includes the Java Runtime Environment (JRE), version 1.4.2 or later. Note that the Windows 2000
JRE default is version 1.3.1. The latest version of JRE can be downloaded from:
http://www.java.com/en/download/manual.jsp
http://www.java.com/en/download/installed.jsp)
• TCP/IP network equipment, as required to connect the reader to a PC, Mac, or other network terminal
• An Ethernet port
• Standard Ethernet cable(s)
• Impinj-approved UHF RFID antenna(s), including associated RF cable with RP-TNC male connector interface
• Standard, grounded DB9 serial cable (required only if system does not support IP provisioning)
for the latest information.
Windows Linux Mac/Other
Netscape (5.5+)
(to determine/verify your version, go to
7
Page 8
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
2.2. Speedway Reader I/O Ports & Status
Refer to Figure 2-1 for the Speedway reader's major ports, connectors, and status indicators, which are clearly indicated on the
unit. The Speedway reader is equipped with the following ports:
• RJ-45 Ethernet port (labeled 10/100 BASE-T)
• Four female RP-TNC RF antenna connectors (ANT1 – ANT4)
• Female DB-9 connector for serial communication (SERIAL)
• Female DB-25 connector with user I/O capability (GPIO) The GPIO contains: RS-232 serial interface, four 3.3/5V
logic inputs, and eight 3.3V logic outputs. See Table 2-2 for the pin-out, Table 2-3 for the GPIO electrical
specifications, and Figure 2-2 for the physical pin view.
Mounting
RJ-45
Ethernet Jack
DB-9 Serial
Port
Figure 2-1 Impinj Speedway Reader Port Connections
Pin I/O Pin I/O Pin I/O
1 No connect 10 GPIN3 19 GPOUT5
2 RS-232 RXD 11 GPIN2 20 No connect
3 RS-232 TXD 12 GPIN1 21 GPOUT6
4 RS-232 CTS 13 GPIN0 22 No connect
5 RS-232 RTS 14 GPOUT0 23 GPOUT7
6 No connect 15 GPOUT1 24 No connect
7 Signal
Ground
8 No connect 17 GPOUT3
9 No connect 18 GPOUT4
CautionPins listed in Table 1-2 as “No connect” must be left unconnected.
Pin Parameter DescriptionMinimumMaximum Unit Conditions
GPIN[3:0]
GPIN[3:0]
GPIN[3:0]
GPIN[3:0]
GPOUT[7:0] VOH
GPOUT[7:0] VOL
GPOUT[7:0] VI
V
IH
V
IL
I
LI
V
I
HIGH-level
input
voltage
LOW-level
input
voltage
Input
Leakage
Current
Input
Voltage
Range
HIGH-level
output
voltage
LOW-level
output
voltage
Input
voltage
range
2 5 V
0 0.8 V
-5 5 µA Vin=0–5V
-5 5 V No damage
3 3.3 V I
0 0.25 V I
= 100 µA
out
= -100 µA
out
-5 5 V No damage
Figure 2-2 DB-25 Female Connector
The labeled LEDs indicate Power, Status, and antenna activity. The LEDs that correspond to the connected antenna(s)
(labeled 1, 2, 3, and 4), only light green when active (transmitting). A description of the status LED states appears in Table 2-4.
Table 2-4 LED Status Indicators
Reader Operation LED Action
Startup Continuous Red
Power-on Start Test (POST) Failure Flashing Red (~2 Hz)
Bootloader Running Off
File System Mounting Operation
(May also occur in certain upgrade scenarios to indicate the
unit is functional but in a file system operation that will take
some time to complete.)
Alternately Flashing Red/Green (1 Hz)
Speedway Reader able to Accept Mach1™ Connection Continuous Green
Speedway Reader in Active Mach1™ Connection Flashing Green (1 Hz)
Inventory in Progress with Tags in Field Flashing Orange (1 Hz)
Inventory in Progress with no Tags in Field (for 3 sec) Flashing Orange (1/3 Hz)
Note Mach1™ denotes the Speedway RFID Command Interface, used by the reader to communicate with
EPCglobal™ Generation 2 (Gen 2) RFID tags.
2.3. Mounting the Speedway Reader
When securing the unit with #10 screws via the four mounting holes, the Speedway reader may be mounted horizontally or
9
Page 10
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
vertically on a stable surface where it will be safe from disturbance. Keep the unit away from direct sunlight, high humidity,
extreme temperatures, vibration, and sources of electromagnetic interference, as any combination of these conditions may
degrade performance or shorten the life of the unit.
2.4. Connecting Power
Connect the AC power plug into a suitable 100-240 VAC, 50-60 Hz power outlet. The reader’s green Power LED will light
when power is on. The reader will then begin its boot sequence (the normal boot time for the reader’s operating system is ~50
seconds). The reader will not accept commands until the boot sequence is complete.
2.5. Connecting the Antenna(s)
The Speedway reader is equipped with four (4) independent, bidirectional, full duplex TX/RX ports (monostatic).
Caution Unused antenna ports must be left unconnected; they should not be terminated.
2.5.1. FCC and Industry Canada
!
Warning Position reader antennas such that any personnel in the area for prolonged periods of time may safely
remain at least 25 cm from the antenna’s surface. See FCC OET Bulletin 65, “Evaluating Compliance with FCC
Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields,” and FCC OET Bulletin 56, “Questions
and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields,” for more
details.
!
Warning Readers of hardware revision 2.0 (see section 2.5.1.1) and higher and ru n ni n g software versions 2.6.0 and higher are capable of up to 32.5 dBm conducted power on the Speedway housing RF connector
and require professional installation.
For readers of revision 1.X.X, power has been factory preset to 30 dBm to accommodate an antenna with 6 dBi composite gain
(inclusive of cabling). The Speedway reader may only be operated with Impinj-approved antennas and can radiate no more
than 36 dBm EIRP (Equivalent Isotropically Radiated Power) per FCC Part 15.247 regulations. The Speedway output power
may be increased to provide the maximum allowable EIRP subject to a maximum conducted power allowance as well. The
maximum conducted power at the antenna connector can be no more than 30 dBm. The maximum allowable output power of
the reader can be set to satisfy both the conducted and radiated maximum criteria. The expression for the maximum re ader
power setting is:
where the composite antenna gain comprises the maximum linear antenna gain in dBi minus any cable loss between the reader
and antenna in dB. Approved antenna vendors, model numbers, and associated gain are listed below:
•Cushcraft Model Number S9028PCL/R (left- or right-hand CP); 6 dBi composite gain (including integrated pigtail
with RP-TNC female connector)
•Sensormatic Electronics Corp. model number IDANT20TNA25 (includes 25 foot Belden 7806A RG-58 coaxial cable
with 2.5 dB loss); 5.5 dBi composite gain
•Sensormatic Electronics Corp. model number IDANT10CNA25 (includes 25 foot Belden 7806A RG-58 coaxial cable
with 2.5 dB loss); 3.5 dBi composite gain
10
Maximum power setting (in dBm)
= THE SMALLER OF
(36 – Composite Antenna Gain (in dB))
OR
(30 + Cable loss (in dB)),
Page 11
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
•Sensormatic Electronics Corp. model number IDANT10CNA06 (includes 6 foot Belden 7806A RG-58 coaxial cable
with 0.6 dB loss); 5.4 dBi composite gain
• Impinj Model Number IPJ-A0301- US A (Mini-Guardrail); -15 dBi gain
• Impinj Model Number IPJ-A0400-USA, CSL CS-777-2 (Brickyard) with 5 foot integrated pigtail to RP-TNC female
connector; 2 dBi composite gain
•Impinj Model Number IPJ-A0401- US A (G u a rd wal l ) wi t h 6 foot integrated pigtail to RP-TNC female connector; 6 dBi
composite gain
!
WarningTheuse of any other antenna may damage the reader or adversely affect performance.
2.5.1.1. Hardware Version
Every reader has a label on the side listing the part number, the serial number, MAC address and hardware revision number
(see Figure 2-3).
Part number
Serial number
MAC address
Hardware revision
Figure 2-3 Reader Labeling
2.5.2. European Economic Area
European regulations allow a maximum radiated power of 33 dBm ERP (Effective Radiated Power) for high power RFID
systems. The maximum Speedway output power is determined by the following equation:
Maximum power setting (in dBm) = 33 – Antenna Gain (in dBd) + Cable loss (in dB)
For example, for an application with an antenna gain of 6 dBd and cable loss of 2 dB, the reader output power can be set no
higher than 33-6+2 = 29 dBm. Note that it is important to apply the antenna gain expressed in dBd (dB with respect to a
dipole), which is equivalent to the isotropic antenna gain (in dBi) minus 2.15 dB. Additionally, the antenna gain used to set the
output power must be the maximum linear gain of the applicable antenna.
11
Page 12
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
3. Communicating with the Speedway Reader
Reader connectivity and control is accomplished via either network (Ethernet, TCP/IP) or serial (RS-232) interfaces on the
Speedway unit (see Figure 3-1).
If connecting via Ethernet, see Section 3.2. If your network equipment is not compatible with the default network configuration
of the reader (DHCP), connecting via the serial interface will be necessary to establish initial command line-level
communications with the Speedway reader. If making a direct serial connection, see Section 3.1.
Set U p
Network
Addressing
Existing DHCP
Network?
No
Configure PC to
Static IP Address
Set U p Reader
Serial Port
Configure Reader
IP Address
Figure 3-1 Configuration Options
Yes
No
Connect Reader
to N etw o rk
Access to
DHCP Server?
Yes
Look U p IP
Address of
Reader via M AC
on DH CP S erver
12
Page 13
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
3.1. Preparing Serial Connectivity
Serial communication with the reader can be used at any time in conjunction with, or in lieu of, Ethernet connectivity in order
to configure the reader. The serial interface may be necessary to establish initial communications with the Speedway reader
(via the command line interface) if your network equipment is not compatible with the default network configuration of the
reader (DHCP). In this case, the reader’s network connection can be configured using the serial port; Ethernet connectivity can
then be used for control thereafter.
Launch HyperTerminal (supplied with Microsoft Windows) or a similar communication program (such as Tera Term for
Windows or Minicom for Linux) to establish serial reader communication. Configuration settings are entered via the command
line interface (see section 4), accessed via your preferred terminal emulator, the prompt for which appears when the reader is
connected to the PC via the serial port and booted.
After connecting the Speedway reader’s serial port to the host PC’s valid/active COM port, plug the reader’s AC power unit
into a suitable 100-240 VAC, 50-60 Hz power outlet. The Power LED will illuminate when power is applied. The reader will
then begin its boot sequence. (Normal boot time for the reader’s operating system is ~50 seconds. The reader will not accept
commands until the boot sequence is complete.)
Set the communication parameters of the terminal software per Figure 3-2 (Tera Term screenshot shown).
Once the terminal window opens, log onto the reader by entering the established user name and password. The default login
(case-sensitive) is:
User Name: root
Password: impinj
The Speedway reader is now ready to accept command line instructions (see section 4).
Figure 3-2 Serial Port Configuration
13
Page 14
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
3.2. Preparing Ethernet (TCP/IP) Connectivity
Connect the reader to your network via the Ethernet port (see Figure 3-3). If your network is capable of communicating to the
reader in its default IP configuration (DHCP), then complete and verify connectivity as described below. Note that the host
computer must be on the same subnet as the reader.
Ethernet
PC
Ethernet
Figure 3-3 Ethernet Connectivity
Connect the computer’s Ethernet port to the Speedway reader using one of the following two methods:
•Use an Ethernet router or switch with either PC IP address set to a static address within the subnet of the reader
(switch) or router’s DHCP set to provide the PC with an IP address within the reader’s subnet.
•Use a single Ethernet crossover cable to connect directly to your PC with the PC IP address set to a static value within
the subnet of the reader.
To verify correct TCP/IP connectivity ping (using the “ping” command) or traceroute (using the “traceroute” command in a
Linux environment, or the “tracert” command in a Windows environment) the reader’s IP address using the PC’s command
line interface. Once connectivity is established, open the computer’s web browser application and connect to the Speedway
reader’s hosted webpage (see Section 4), and login to complete the Speedway reader configuration. The default login (casesensitive) is:
User Name: root
Password: impinj
Proceed to section 4 to configure the network.
3.3. Mach1 Interface
The Speedway reader has a comprehensive RFID Command Interface, the Mach1, used by the reader to communicate with
EPCglobal™ Generation 2 (Gen 2) RFID tags. Many application providers offer software that is compatible with Mach1.
Consult your solutions provider or applications software vendor for additional information.
14
Page 15
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
4. Network Configuration
The network may be configured for the Speedway reader using the Rshell command line interface (CLI), accessed via the serial
port (see section 3.1) if your system does not support DHCP.
To complete the host name, concatenate the last three bytes of the unit’s MAC address (printed on the Speedway reader
enclosure and expressed in hexadecimal, e.g., MAC 00:16:25:00:41:0C) to the word “speedway” separated by “-” (e.g.,
speedway-00-41-0C).
Shown here are the essential configuration commands; for complete information on this interface, see section 8).
To view the reader's current configuration settings, enter the following command at the prompt:
> show network summary
The reader will respond with the following (sample only; actual data will differ):
At this point, the TCP/IP configuration parameters, such as its IP status (static or dynamic) and hostname, may be changed via
the following command examples:
•To set hostname, at the prompt, enter the command:
config network hostname <HOSTNAME>
• To set static IP address, at the prompt, enter the command:
config network ip static <IP ADDRESS> <NETMASK> <GATEWAY> <BROADCAST>
•Alternatively, either of the following two versions of the config network ip static command may be used, in which
case the reader will use default values for the unspecified parameters:
config network ip static <IP ADDRESS>
config network ip static <IP ADDRESS> <GATEWAY>
• To set DHCP, at the prompt, enter the command:
config network ip dynamic
You may now continue to use the Speedway reader in serial mode or connect to the network via the Speedway reader's
Ethernet port.
15
Page 16
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
5. Speedway Reader Settings
Navigate to the Speedway reader's hosted webpage. If using DHCP with DNS hostname registration enabled, connect via the
default host name by navigating the browser to http://speedway-nn-nn-nn, where nn-nn-nn represents the host name suffix.
To complete the host name entry, concatenate the last three bytes of the unit’s MAC address (printed on the Speedway reader
enclosure and expressed in hexadecimal, e.g., MAC 00:16:25:00:41:0C) to the word “speedway” separated by “-” (e.g.,
speedway-00-41-0C).
If your DHCP server does not support DNS hostname registration, the option has been turned off in Rshell, or you are using a
static IP address, navigate to the IP address assigned (e.g., http://xxx.xxx.xxx.xxx
DNS server (e.g., http://hostname). You’ll then be directed to the specific Speedway unit’s homepage (see Figure 5-1), which
details the hostname, IP address, serial number, hardware revision, and system statistics information. Note that the actual GUI
appearance may vary from that shown in this User’s Guide.
) or the host name manually specified in your
Figure 5-1 Speedway Reader Homepage
The Speedway reader applet is a Java program that runs from within a web browser. The Speedway reader requires Java
Runtime Environment (JRE), version 1.4.2 or later. Note that the Windows 2000 default of JRE is 1.3.1. The latest version of
JRE can be downloaded from: http://java.com/en/download/manual.jsp
The Speedway reader applet is accessed via the RFID menu tab in the navigation bar at the top of this page. (If the applet is
opened, no other external software may connect to the reader via Mach1™.) Clicking this tab will bring up a region selection
page (see Figure 5-2).
16
Page 17
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Figure 5-2 Region Selection Page
Selecting a region will bring up a dialog box prompting the user to enter a login ID and password, the default for which is:
User name: root
Password: impinj
The Java applet will load and open the Settings page (see Figure 5-3).
The five user-selected fields on the Settings page include Mode, Antenna, Session, Transmit Power, and Channel, each of
which are described below.
Figure 5-3 Speedway Reader Settings Page
Mode
The reader mode is established via the Mode pull-down menu. Mode profile is a factory preset that configures the reader
according to the respective default settings of that mode. For specific usage applications of the various modes, see Table 5-1.
17
Page 18
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 5-1 Mode Usage
Mode Mode Description Usage
Very fast read rate
0 Maximum Throughput
1 Hybrid
2 Dense reader M=4
3 Dense reader M=8
Antenna
The Speedway reader supports four (4) independent, bidirectional, full duplex TX/RX ports. Each antenna port is labeled
(ANT1−ANT4) on the Speedway unit and these designations correspond to the Antenna selection buttons that appear on the
lower third of the screen. Only those antennas activated by clicking the appropriate button(s) will be operational. (See Figure
5-4.)
Very wide spectral occupancy
Used for low interference environments where speed matters
Fast read rate
Intermediate spectral occupancy
Tolerant of some interference
Intermediate read rate
Minimal spectral occupancy
Very robust to interference
Half the data rate of Mode 2
Miller (M=8) may be used in extreme interference environments where tags are
stationary or moving slowly
Figure 5-4 Closeup of Variable Selections
Session
The reader may be assigned to one of three sessions (1−3), selectable via the Sessions pull-down menu. A function of densereader mode, the use of sessions allows as many as three different readers to access the same population of tags through a timeinterleaved process. In this mode, a shelf-mounted reader in the midst of a counting operation (assigned to Session 1, for
example) may be interrupted by another reader entering the field—possibly a handheld reader—to perform its own inventory
operation (in Session 2, for example). A dock door or forklift reader (assigned to Session 3, for example) might also initiate an
inventory round. Because Gen 2 tags maintain a separate "inventoried" flag to keep track of each of these various random and
independent sessions, they're able to seamlessly resume their participation.
Transmit Power
The reader power setting is selected from the Tx Power pull-down menu. The output power ranges from 15 dBm to a
maximum of 30 dBm (in .25 dB increments), measured at the Speedway reader's antenna ports.
Channel
North America: The FCC stipulates frequency hopping across the North American spectrum allocated to UHF RFID
(902−928 MHz, with hopping occurring between 902.75−927.25 MHz in 500 KHz steps). As such, the Speedway reader does
not allow the setting of a static frequency for North American operation and the Channel is factory-set and fixed to frequency
hop.
Europe: A pulldown menu supports channel selection.
Taiwan: The NCC stipulates frequency hopping across the Taiwanese spectrum allocated to UHF RFID (922-928 MHz, with
hopping occurring between 922.25–927.75 MHz in 500 KHz steps). As such, the Speedway reader does not allow the setting of
a static frequency for North American operation and the Channel is factory-set and fixed to frequency hop.
18
Page 19
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
19
Page 20
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
6. Using the Speedway Reader
Once the Speedway reader settings have been established, the user may proceed directly to the Operation screen by clicking
its menu navigation butto n .
From the Operation page, simply click the Start/Stop toggle button to begin reading tags within range of the reader. The Clear
button clears the results of the inventory operation that commenced with Start.
Tags being read are displayed in white fields, which fade to blue after not being seen by the reader within the last ~10 seconds.
To see all tags and their status, simply scroll the screen.
As tags are read, their EPC numbers appear in the primary window of the Operation screen. If the Read TID button on the
Operation screen has been enabled, the logo of the tag silicon manufacturer corresponding to the TID will also be displayed.
In addition to the EPC and TID, the results displayed include: Read Rate (expressed as tags/sec), Running Time (in hh:mm:ss
from last Start), Total Tags (total number of tags read), and Total Active Tags (number of tags currently in the reader's field of
view).
For more sophisticated inventory operations, the Inventory Filter and Tag Access pages allow the selection of tags according
to user-specified criteria and rules. To access the Inventory Filter, Tag Access or protocol setup menus, any currently executing
operation must be stopped.
6.2. Operation Screen—Filters
If the Inventory Filter has been activated (see Section 6.3), this status will be indicated in the Operation screen view (see Figure
6-2) with the text **Inventory Filter** appearing at the top of the screen. Likewise, if the Halt Filter has been activated (see
Section 6.4), the text **Halt Filter** will appear.
Auto Continue
20
Figure 6-1 Operation Screen
Page 21
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Referring to the set buttons in the lower-left portion of the Operation screen, Auto Continue directs the reader to continue
singulation after a halt condition has been met. Otherwise, if the Halt Filter has been set, the reader will stop reading and return
control to the user, resuming operation only when the Continue button has been clicked by the user. Note also that Halt does
not require any subsequent action.
Act Once
The Act Once button, if enabled, directs the reader to execute the action indicated in the Tag Access Action setting (read, write,
lock, kill, etc.) only one time (see section 6.4). If the operation is successful (see Last Status column in the primary read
window), the reader will continue the inventory or halt operation, depending on the status of the Auto Continue setting. If the
Act Once setting is not enabled, and the action indicated is a write, the reader will write the tag over and over in a continuous
loop. If both Act Once and Auto Continue are enabled, the reader will write the tag once and then continue the inventory
operation, responding in accordance with the Inventory Filter settings that have been established.
To change settings from Operation mode:
a. Stop continuous singulation using the Start/Stop button
b. Configure the reader to the desired new mode using the Settings, Inventory Filter and Tag Access pages
c. Return to the Operation page and re-start continuous singulation
Figure 6-2 Operation Screen with Filters Enabled
6.3. Inventory Filter Screen
The Inventory Filter screen (see Figure 6-3) is the user interface to the Select command, which the reader may apply
successively to sort a particular tag population based on user-defined criteria that may include union, intersection, and
negation-based tag partitioning (union and intersection operations are performed by issuing successive Select commands).
Select commands apply to a single memory bank; the Mem Bank field specifies if the criteria applies to the TID, EPC, or User
memory of the tag (see Figure 6-4), as follows:
Mem Bank 00 (0): Reserved (cannot select filter on this bank)
Mem Bank 01 (1): EPC
Mem Bank 10 (2): TID
Mem Bank 11 (3): User
21
Page 22
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Successive Selects may apply to different memory banks. The Bit Offset and Bit Length fields are used to target a specific
portion of the tag memory on which to perform the filtering, while the Pattern field contains the comparison bits of interest.
Note that the Bit Length must be non-zero. As tags are read, the Pattern is evaluated against the Select criteria, which includes
Equal and Not Equal options in the Comparison field.
The Inventory Filter allows the use of two sets of criteria (defined by primary filter A and secondary filter B) that may be used
separately, jointly, or not at all (the pull-down options include No Filter, A ONLY, A AND B, A OR B). When applied to an
inventory round, only those tags that match the Select criteria will be displayed.
Figure 6-3 Inventory Filter
In Figure 6-3, the Pattern written is “0xE017FF00431E55550000000000000000, the bit offset is “0x0020”, and the bit length is
“0x0040.” The bit offset for an EPC code must be nonzero because the first 32 bits in the memory map (see Figure 6-4) are
taken up by the CRC and PC codes. Figure 6-5 provides an example of how this pattern would be stored into the tag memory.
22
Page 23
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
MSB
LSB
…
Bank 11
Bank 10
Bank 01
Bank 00
USER
TID
EPC
RESERVED
10
00
h
h
MSB
TID [15:0]
TID [31:16]
EPC [15:0]
…
20
10
00
h
h
h
MSB
EPC [N:N-15]
PC [15:0]
CRC-16 [15:0]
…
30
h
20
h
10
h
00
h
Figure 6-4 Tag Memory Map
Access Passwd [15:0]
Access Passwd [31:16]
Kill Passwd [15:0]
Kill Passwd [31:16]
LSB
LSB
1F
0F
2F
1F
0F
3F
2F
1F
0F
h
h
h
h
h
h
h
h
h
Figure 6-5 Writing EPC Example
6.4. Tag Access Screen
After acknowledging a tag, the Speedway reader may choose to access it. Under the Tag Access menu, a pull down menu
provides five command Actions: Read, Write, BlockWrite, Lock, and Kill.
The menu item Tag Access (see Figure 6-6) adds a Mask field to the filtering operation, which allows the user to mask
individual "don't care" bits or segments of the matching pattern, where "1" identifies a bit of interest and "0" represents a
masked bit.
23
Page 24
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Tag Access differs from the Inventory Filter operations in several respects. First, rather than performing a continuous inventory
of a tag population, Tag Access allows the user to automatically halt the inventory process upon finding a tag of interest (e.g., a
tag that meets the Halt Filter criteria). At this point, the tag can be automatically read, written, locked, or killed, according to
the action selected in the Action pull-down menu. Note that the Halt criteria memory bank is independent of the write memory
bank. For example, in Figure 6-6, the halt criteria is based on the EPC but the write action will happen on the TID.
The action is applied only to the selected Mem Bank and within it, the desired memory rows (00−07), the rows being made up
of 16-bit words. If Action calls for a write, the specific bit pattern to be written must be entered (in hex format) in the
corresponding field(s) below the selected row number(s). Multiple selected rows must be contiguous. For example, if only data
in rows 1 and 3 must be changed, the data for row 2 must still be entered. The row number will change color to orang e to
indicate the valid rows for each memory bank. In the example of Figure 6-6, the TID only encompasses two sixteen bit rows so
only rows 0 and 1 change color to orange to indicate valid selections. For the EPC, row 0 may not be overwritten (this is the
CRC field, see Figure 6-4).
For Tag Access, the comparison criteria supports Greater Than and Less Than in addition to the Equal and Not Equal options
available in the Inventory Filter page.
The Tag Access view is consistent with the Operation view (described in sections 6.1 and 6.2) in that settings input into one
screen are valid for the other.
24
Figure 6-6 Tag Access
Page 25
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
6.5. Version Screen
The Version screen (see Figure 6-7) simply reports the versions of the four primary components of the Speedway reader.
Figure 6-7 Version
25
Page 26
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
7. Firmware Upgrade
The Speedway reader provides methods for managing the firmware image which include:
• Upgrade to a new image
• Fallback to a previous valid image
• Restore to factory default settings
These can be done without disturbing the current operation of the reader. The user may manage the upgrade process through
the steps described in this section. The upgrade may be performed via the command line interface or via the GUI Configuration
Menu tab.
Terms and Acronyms
• Client: the user program that uses the upgrade management service
• Primary image: the image that is currently running
• Secondary image: the image that is not running and may be the target of upgrading or fallback
• Upgrade Configuration: the information for determining the upgrading procedure
• Upgrade Image File: file that contains the Speedway reader image used for upgrade—stored on a file server and
retrieved by the Speedway reader
• Metafile: data file that resides on a file server and contains the Upgrade Configuration information
• Metafile-URI: Universal Resource Identifier of the metafile
• URI: Universal Resource Identifier as defined in RFC3986
Dual Image Model
The flash layout can be viewed as consisting of primary and secondary images, each of which contains three partitions, as
shown in Figure 7-1. The primary image is the image that the reader is currently running and the secondary image is used for
upgrade to a new image or fallback to a previous image.
Partition 2
Custom
Application
Partition
Custom
Application
Partition
Primary
ima ge
Secondary
ima ge
Partition 0
Speedway
OS Pa rtitio n
Speedway
OS Pa rtitio n
Partition 1
Speedway
Configuration
Partition
Speedway
Configuration
Partition
Figure 7-1 Dual Image Model
The three partitions in each image are:
•Partition 0, the Speedway OS Partition (SOP). This partition contains the Linux OS image, file system, and Impinj
reader application.
•Partition 1, the Speedway Configuration Partition (SCP). This partition contains the Impinj reader application
configuration and other general configuration data.
•Partition 2, the Custom Application Partition (CAP). This partition may contain a custom application.
Partitions 0 and 2 can be individually upgraded, while Partition 1 can be upgraded only when Partition 0 is upgraded.
Upgrade is performed in the background, so that the current operation of the reader is not disturbed until the activation of the
new image. The time of activation is also controlled by the user.
26
Page 27
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Image Versioning Scheme
Each partition has a four-part version number associated with it. In the upgrade configuration file (see section 7.3), the version
number is represented by a string consisting of four fields separated by ‘.’ (dot):
where each field is a decimal number ranging from 0 to 255. The left-most field is the most significant part of the version
number with sub-versions provided to the right. For the purpose of upgrades, when two version numbers are compared, the one
with the largest leftmost number is considered a higher version and therefore a newer image. For example, if two versions
being compared are 2.3.4.9 and 2.4.4.1, 2.4.4.1 is considered newer because the second number from the left is larger (in this
case 4 versus 3). Other than this comparison, the upgrade mechanism assumes no additional meaning for the version string.
ddd.ddd.ddd.ddd
7.1. Upgrade Methods
Speedway provides two methods to support software upgrade: push and pull. Push mode is a manual technique to perform an
upgrade on an individual reader. Pull mode is an upgrade method that allows simultaneous upgrade of multiple readers
through a single Upgrade Configuration file called a metafile. The default configuration of the reader is “push” mode.
In push mode, the user can trigger a one-time upgrade of the Speedway image. When triggering the upgrade, the user must
specify the location of the Upgrade Image File as a URI. The upgrade will be performed if any of the partitions within the new
image are different than those contained in the primary image. Once the download and programming have completed, the
reader will remain in push mode and will perform no further upgrades until a new client request is issued. In push mode, the
reader will not reboot automatically to activate the new image. The user must issue a reboot command (see section 8.3.1) to
complete the activation.
In pull mode, the user creates a custom Upgrade Configuration Metafile (or metafile for short). This metafile is stored on a
remote server. The user configures the location of the metafile as a URI. The reader downloads the data contained in the
metafile at periodic intervals (called the retrieve period) and uses that data to make automatic upgrade decisions. The reader
remembers the retrieve mode, retrieve period, and URI across power-cycles so that it can resume the pull method after a system
reboot. Typically, when the reader retrieves the metafile at a scheduled time (or when it reboots), it will find that no upgrade is
needed because, in the absence of any change in the metafile on the server, the image version the reader is running is the same
as that specified in the metafile.
7.2. Preparing the Upgrade Image
The path and permission of the image file on the server should be set properly to allow file retrieval via the method as specified
by the upgrade-file-uri field of the metafile or by the image URI.
7.3. The Upgrade Configuration Metafile
The Upgrade Configuration metafile is at the cor e of the pull upgrade mechanism. The user prepares this file based on upgrade
requirements and saves it on a file server accessible from the reader. The file contains instructions to the Speedway reader as to
how to perform the upgrade as a list of text-based entries. Each data entry consists of a single line data field and may be
qualified with one or more parameters separated with a semi-colon. Table 7-1 lists the data entries in the metafile. All data
fields and parameters are mandatory unless marked as optional. The format of a data entry is as follows:
Important The metafile must not contain any Unicode characters.
27
Page 28
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 7-1 Upgrade Configuration Definition
Field Name Field Value Param Na me
This field indicates how the metafile is to be retrieved.
retrievemode
upgrademode
push This field tells the reader to wait to be given upgrade information directly
pull
This field indicates how the reader determines the need for upgrade.
auto
forced
This field indicates how the image should be activated.
immediate
wait-4-cmd The image should be activated by a reboot command from the user.
retrieveperiod
The reader determines if an upgrade is necessary based on its knowledge of the local image
version compared to the upgrade file. Upgrade is needed if the local image has at least one
partition that has a lower version than the corresponding partition in the upgrade image file.
The reader should upgrade as long as the current image has at least one partition that has a
different version from the corresponding partition in the upgrade image file.
The image should be activated immediately after the upgrade is complete, causing an immediate
reboot after programming is complete.
commitmode
dl-retries
dl-retry-
period
upgrade-file
img-type
upgrade-
file-uri
partition
scheduled
<int> Number of times to retry if download fails due to timeout.
<int> Time to wait (seconds) before retrying a download.
<int>
<int>
<string> This field is the URI of the upgrade image file from which the upgrade image is downloaded.
This field is the partition descriptor in an upgrade file. Refer to release notes for specific values.
<int> version <string>
time <string>
early-act-ok
(optional)
This field is used as a delimiter. It means all data fields after this one, up to the next delimiter or
end of metafile apply to the upgrade file indexed by the number in the field value <int>.
This field indicates the image type of the upgrade file specified by the
enumeration number <int>. Refer to release notes for specific image type.
Param
Value
<int>
{no, yes}
Description
This field tells the reader to periodically retrieve the metafile.
The mandatory parameter specifies how often (in minutes) the
reader downloads the metafile
Reboot is scheduled at the time indicated by the mandatory
parameter time. The value of time is a string that takes the
format of “<time-zone>:yyyy:mm:dd:hh:mm:ss” where
<time-zone> is gmt.
It’s OK to activate the upgraded image before its scheduled
activation time due to an early reboot. Default value is no when
this parameter is absent.
filefield. The type is the
Version of the partition, consisting of 4 fields of decimal
numbers separated by a dot ‘.’. The number in each field must
be in the range of 0 to 255.
7.4. Preparing the Upgrade Configuration Metafile
The upgrade configuration metafile is prepared on the server as pointed to by the reader’s metafile URI. The data entries in the
metafile should follow the format and definition given in section 7.3. Missing mandatory data entries and bad syntax will cause
the reader to reject the metafile.
The upgrade image file pointed to by the upgrade-file-uri field must contain the same partitions, image types, and versions as
described by the partition fields in the metafile. Disagreement between the metafile and the upgrade image file will cause the
reader to reject the downloaded image file.
The path and permission of the metafile on the server should be set properly to allow file retrieval via the method specified by
the URI parameter in the config image metafile command as explained in Section 8.4.2.3.
28
Page 29
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
7.5. Image Management Command
7.5.1. Command Line Interface Upgrade
An upgrade can be triggered via the Command Line Interface in any one of the following scenarios:
•The user can invoke the Rshell command config image upgrade to instruct the reader to enter push mode, directly
download the upgrade image file from the specified URI, and perform an upgrade with the image downloaded. See
section 8.4.2.5 for details.
•The user can invoke the Rshell command config image metafile to instruct the reader to enter pull mode, download a
metafile from the specified URI, and perform an upgrade based on the metafile. Regardless of the upgrade status, the
reader remembers the URI for future use. See section 8.4.2.3 for details.
•The user can invoke the Rshell command config image retrievemode to manually set the retrieve mode of the reader.
If the retrieve mode is set to pull via this command and the reader has a valid metafile URI, the reader will
immediately attempt to retrieve the metafile via the URI. If metafile retrieval fails, the reader will retry periodically
based on the retrieve period specified in the comma nd. See sect i on 8. 4. 2.4 for details.
7.5.2. GUI Upgrade
To use the GUI to execute push mode, click on the Configuration menu tab and select Firmware Upgrade (see Figure 7-2). The
user must specify the location of the Upgrade Image File as a URI, enter it into the dialog box and click Submit. The upgrade
will be performed if any of the partitions within the new image are different than those contained in the primary image. The
Upgrade Status window will display the current image summary (similar to the upgrade status field in the show image summary command, see section 8.5.2.2). Once download and programming have completed, the reader will remain in push
mode and will perform no further upgrades until a new request is issued.
In push mode, the reader will not reboot automatically to activate the new image. The user must issue a reboot command by
clicking on the reboot button in the firmware upgrade GUI screen to complete the activation. The reader will not accept the
reboot command until the image downloading and programming has completed, indicated by a “Done” status in the Upgrade
Status dialog box. In other words, the reboot command issued to the reader by selecting the reboot button on the GUI interface
does not have the force option (see section 8.3.1).
If the user enters a file into the Image URI dialog box illustrated in Figure 7-2 and performs a reboot, the reader will revert to
push mode, even if it had previously been in pull mode.
Important The filename must be specified in the format described in section 7.8 (TFTP, FTP, or HTTP).As with any
remote file retrieval, the servers should be properly configured such that the files are accessible either
anonymously or by the specified user from the client (the reader).
29
Page 30
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Figure 7-2 Push Mode Upgrade GUI Screen
To use the GUI to enter pull mode, click on the Configuration menu tab, select Firmware Upgrade, and then select Advanced
(see Figure 7-3). The user must create a custom Upgrade Configuration Metafile (or metafile for short), store it on a remote
server, and configure the location of the metafile as a URI. This URI may be entered into the dialog box labeled Metafile URI
and submitted to the reader via the Submit button. The reader downloads the data contained in the metafile at periodic
intervals, called the retrieve period. The retrieve period is a mandatory parameter in the metafile (see section 7.3) but it may be
changed by entering a new retrieve period into the dialog box labeled Period in the Retrieve Mode section and clicking the
Submit button. The user may also select the Pull option under Retrieve Mode by clicking on the Pull radio button; however,
without a valid metafile, the software will issue an error. This can be resolved by entering a valid metafile.
The reader remembers the retrieve mode, retrieve period and URI across power-cycles so that it can resume the pull method
after a system reboot. This will be reflected in the GUI by the darkened Pull radio button and a retrieve period value indicated
in the dialog box.
The user may halt the automatic periodic updates and revert to Push mode by selecting the Push radio butto n under the
Advanced screen.
30
Page 31
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Figure 7-3 Pull Mode Upgrade GUI Screen
7.5.3. Factory Default Restoration
The following command can be used to restore the Speedway reader's factory default configuration settings associated with the
currently running image:
•The user can use the Rshell command config image factory to return the reader to a factory default configuration.
The command retains the current primary SOP, but defaults the reader’s configuration and erases any custom
application. See section 8.4.2.1 for details.
7.5.4. Fallback to Previous Image
The following command can be used to fallback or restore the reader’s previous image in case something was adversely
affected by the upgrade procedure:
•The user can invoke the Rshell command config image fallback to restore the reader to its previous image. See
section 8.4.2.2 for details.
7.5.5. Query the Upgrade Status
The following commands are used to query the status of upgrades includi n g fact ory de fau l t and fallback:
•The user can invoke the Rshell command show image summary
secondary images. This command also shows the status of pending and completed upgrades as well as error codes
indicating the reasons for upgrade failures. See section 8.5.2.2 for details.
•The user can invoke the Rshell command show image metafile
metafile data. See section 8.5.2.1 for details.
to view the details of the current primary and
to view the details of the current retrieve mode and
7.5.6. Background Execution of Image Management Commands
Some image management commands are executed in the background and are not finished right away. If a previous image
management command is still being processed, a subsequent image management comma nd will be rejected with a command
response code of “Previous-Command-In-Progress”. The following image management commands have this
behavior:
config image metafile
config image upgrade
31
Page 32
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
config image factory
During the execution of these image management commands, the reboot command will also be rejected with the “Previous-
Command-In-Progress” error unless the force option is applied. All other config image and show image commands are
completed immediately and can be immediately followed by any other image management command.
7.6. Upgrade Examples
Shown below is an example of command line activity demonstrating a successful upgrade, using the push method. The text
entries after the # sign are comments.
# Issue a command to upgrade using FTP. The file path is only an example.
>
> config image upgrade ftp://username:password@server1.mydomain.com/binaries/sop2_4_0.upg
Status=0,'Success' # command accepted
>
> show image summary # Query status
Status=0,'Success'
UpgradeStatus=Downloading # Reader determines upgrade is needed and starts download
# Current image info
primaryImageType=2
primaryImageSystemVersion='2.4.0.144'
primaryImageConfigVersion='255.255.255.255'
secondaryImageType=2
secondaryImageSystemVersion='2.4.0.128'
secondaryImageConfigVersion='255.255.255.255'>
> show image summary
Status=0,'Success'
UpgradeStatus=Erasing # Download OK. Erasing secondary flash
primaryImageType=2
primaryImageSystemVersion='2.4.0.144'
primaryImageConfigVersion='255.255.255.255'
secondaryImageType=2
secondaryImageSystemVersion='2.4.0.128'
secondaryImageConfigVersion='255.255.255.255'
>
> show image summary
Status=0,'Success'
UpgradeStatus=Programming # Now programming new image
primaryImageType=2
primaryImageSystemVersion='2.4.0.144'
primaryImageConfigVersion='255.255.255.255'
secondaryImageType=2
secondaryImageSystemVersion='2.4.0.128'
secondaryImageConfigVersion='255.255.255.255'
>
> show image summary
Status=0,'Success'
UpgradeStatus=Done # programming done successfully
primaryImageType=2
primaryImageSystemVersion='2.4.0.144'
primaryImageConfigVersion='255.255.255.255'
secondaryImageType=2
secondaryImageSystemVersion='2.4.0.128'
secondaryImageConfigVersion='255.255.255.255'
>
32
Page 33
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
# Reader is waiting for reboot to activate the new image. All other activities are
#not affected.
>
> reboot
Status=0,'Success'
>
# when status LED comes back on as solid green, the reader will be running from
# the new image
7.7. Metafile Example
Below is an example of a complete metafile (note that the metafile may contain comment lines that start with a pound sign #):
## This is an example upgrade config metafile.
## Lines commented out with single # are alternative values or additional fields
## Lines commented out with double ## are explanations
##
## retrieve-period is in minutes
retrieve-mode:pull;retrieve-period=60
#retrieve-mode:push
upgrade-mode:auto
#upgrade-mode:forced
## reboot at a scheduled time yyyy:mm:dd:hh:mm:ss
commit-mode:scheduled;time=”local.2006:05:08:04:12:32”;early-act-ok=yes
#commit-mode:wait-4-cmd
#commit-mode:immediate
## dl-retries defaults to no-retry if not present. retry only if failed due to
timeout
#dl-retries:3
## dl-retry-period is in seconds
#dl-retry-period:60
upgrade-file:0
img-type:2
upgrade-file-uri:”tftp://fileserver.store.com/impinj-reader-image.upg”
## partitions and their versions must agree with what’s in the image
partition:0;version=”2.0.1.240”
#partition:1;version=”255.255.255.255”
#partition:2;version=”1.0.0.3”
7.8. Other URI Examples
The Speedway reader supports three URI schemes for upgrade: TFTP, FTP, and HTTP. Other examples of URIs:
As with any remote file retrieval, the servers should be properly configured such that the files are accessible either
anonymously or by the specified user from the client (the reader).
7.9. Detailed Upgrade Behavior
33
Page 34
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
7.9.1. Upgrade file validity check
The reader always checks the following for the validity of the upgrade file:
• Upgrade file format
• Upgrade file CRC
• Hardware compatibility with the reader
• Agreement between the upgrade metafile and the upgrade image in terms of version number, image type and
partitions present.
If the check fails, the upgrade is aborted and the status is reported via the show image summary command as explained in
section 8.5.2.2.
7.9.2. Rapid Polling Intervals
If the reader is configured to update automatically (pull mode) and the user attempts to send the reader into push mode by
sending a config image update command, it is possible that the user will receive the message, “Command-in-Progress”
because the automatic update just happened to occur at the same time as the manual command. This situation will most likely
occur if the user’s network is slow or heavily loaded and the retrieve period (polling interval) is short.
7.9.3. Upgrade decision
Not all upgrade attempts will result in an actual upgrade, even if the upgrade file is valid. The reader’s upgrade decision is
based on the following factors:
• The image versions of the SOP and CAP partitions of the primary image.
• The image version(s) of the partition(s) in the upgrade metafile and the upgrade image files downloaded, as well as
the number of partitions present.
• The image type of the primary image, as well as the type indicated by the image metafile and upgrade file.
• The upgrade mode, forced or auto, as indicated in the upgrade metafile.
In auto upgrade mode, the upgrade will happen only when either one of the following is true:
•The upgrade image has the same type as the primary image and at least one partition in the upgrade image has a
version higher than the corresponding version in primary image. In th is case the partitio n in th e upgrade file th at has a
lower version number than the one in the primary image will not be used, instead the curren t primary partition will be
kept.
•The upgrade image has different image type from the primary and SOP is present in the upgrade file.
In the forced upgrade mode, an upgrade will happen as long as at least one partition in the upgrade file has a differen t version
from the primary image. If the config image upgrade command is used, the upgrade is always performed regardless of version
numbers or image type.
7.9.4. Partition copy-over
The upgrade image file does not necessarily contain all the partitions. The missing partition(s) will be cop ied over to the
secondary image from the primary image upon reboot after upgrade whenever applicable. The behavior is as follows:
If the upgrade file has the same image type as the primary image, then
• If the upgrade file contains the SOP only, the primary SCP and the CAP (if present) are copied over.
• If the upgrade file contains the SOP and the CAP, the primary SCP is copied over.
• If the upgrade file contains the CAP, the primary SOP and the SCP are copied over.
• If the upgrade file contains the SOP and the SCP, the primary CAP, if present, is copied over.
Otherwise, if the upgrade file has a different image type from the primary image, no partition is copied over. The new image
will use the factory default configuration if there is no SCP in the upgrade file. Such behavior allows the current config uration
and custom application to be carried over to the new image after an upgrade.
7.9.5. Image partitions already programmed
There are cases when the partitions in the upgrade file are already on the secondary image. For example, when a reboot is
scheduled in ten hours following a successful upgrade and the reader is pulling the metafile every ten minutes, it will find that
the same partitions in the metafile already programmed on the secondary image. The partitions are sto red in flash memory
34
Page 35
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
which by its nature has a limited number of programming cycles. To avoid unnecessary programming of this flash memory, the
reader checks if any or all of the intended partitions are already programmed and the behavior in these cases is as follows:
•If the upgrade file contains the SOP only and it is already on the secondary image, there is no reprogramming of the
flash memory except for marking the primary SCP and the CAP, if present, to be copied over upon reboot after
upgrade. (See section 7.9.4)
•If the upgrade file contains the SOP and the CAP and both are already on the secondary image, there is no
reprogramming of the flash memory except for marking the primary SCP to be copied over upon reboot after
upgrade.
•If the upgrade file contains the CAP only and it is already on the secondary image, the primary SOP is copied to the
secondary image and the primary SCP is marked as to-be-cop ied over upon reboot after upgrade.
These behaviors only apply to automatic upgrades performed via the periodic pull method with auto or forced upgrade mode.
When the upgrade is manually commanded (pushed) with the config image upgrade command, the flash memory is always
programmed with the upgrade image regardless of the versions on the primary and secondary images.
35
Page 36
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8. Rshell Command Line Interface
The Speedway reader's Rshell Command Line Interface (CLI) is accessed via serial, Telnet, or SSH connectivity. A graphical
representation of the command structure is shown in Figure 8-1.
Figure 8-1 Command Line Interface Tree
36
Page 37
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8.1. Rshell Overview
Users may navigate to any of the menus simply by entering the menu name at the Rshell prompt, as shown below:
> show network
show network >
At all menus, the help command (or simply ?) will list all the commands available from the active menu, as well as the
submenus that can be accessed from the active menu.
> help
Commands:
osshell - Starts an OS shell for direct access to reader.
reboot - Reboots the system.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
? - Displays this help message.
Sub-menus:
config - Submenu of configuration commands.
show - Submenu of elements that may have their configuration or
status shown.
transfer - Submenu of transfer commands.
Menu navigation and the help keyword (or ?) can be combined on the same line to list all the commands available for that
menu. For example:
> config ?
Commands:
access - Changes the password for a given access level.
CLI - Not handled yet.
rfid - Not handled yet.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
image - Submenu of image and upgrade configuration commands.
logging - Submenu of logging configuration commands.
network - Submenu of network configuration commands.
system - Submenu of system info configuration commands
>
At all menus, entering the help command or ? prior to a command or menu, will return the syntax for its usage. For example:
> ? config
config - Submenu of configuration commands.
Usage: config [<subcommand> ...]
>
or
37
Page 38
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
> ? config access
config - Submenu of configuration commands.
Usage: config [<subcommand> ...]
access - Changes the password for a given access level.
Usage: config access <level> <password>
<level> is one of: root readonly readwrite (currently only
root is supported)
<password> is any text, please use at least six characters.
>
Entering the ? between a menu and sub-menu/command will return the usage for all items following the ?. In the example
below, image is a menu that contains commands of its own.
> config ? image factory
image - Submenu of image and upgrade configuration commands.
Usage: image [<subcommand> ...]
factory - Revert to factory defaults.
Usage: image factory
>
Required parameters are indicated by angle brackets (e.g., <parameter>), while optional parameters are indicated by square
brackets (e.g., [parameter]). At all menus, the exit command or simply ‘.’ will return the user to the previous menu context. To
exit Rshell and terminate the user session (serial, telnet, or SSH), the exit command must be executed from the root menu:
show network> exit
show>
For machine execution, all commands can be called from the root menu. For example:
> show network
show network> dns
is equivalent to:
> show network dns
All commands return data in machine/human readable format.
8.2. Error Codes
The first line of every response has the following format:
Status=errorCode,’error string’
Where errorCode is a numeric value and ‘error string’ is a single-quoted human-readable error code. The error codes are
defined in Table 8-1.
38
Page 39
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 8-1 Error Codes
Error Code Error String Description
0 Success
1 Invalid-Command
2 Invalid-Command-Parameter
3 Invalid-Parameter-Value
4 Parameter-Dependency-Error
5 Incomplete-Parameter-List
6 System-Resource-Limit
7 Unsupported-Command Reserved for Future commands
8 Permission-Denied
9 Previous-Command-In-Progress
10 Command-Being-Processed
A sample error parameter string is shown below:
> conffigg
Status=1,'Invalid-Command'
When a command’s action requires return parameters, they follow the error status, one parameter per line, and in the following
format:
The specific response parameters are detailed in the sections that follow.
Command could not be parsed and identified as one of
the commands supported by the interface
One or more parameter types was unrecognized for
this command
One or more parameter values was illegal or out-ofrange for this command
Parameter value or combination was invalid in
combination with other parameters or values
The parameter list was incompletely specified and the
command cannot be executed
Command could not be executed because of a
resource limit on the box (e.g., could not add a fourth
trap receiver because the device only supports three)
User does not have permission to access this
command
The command was rejected because a previous
command is still in progress such that this one could
not be processed
The command cannot be finished right away; it is
being processed.
8.3. Root Menu
Referring to Figure 8-1, the root menu contains the reboot command, and links to the config, show, and transfer sub-menus.
8.3.1. reboot Command
The reboot command instructs the reader to reboot. This may be used after a manual upgrade of the reader’s firmware or
application software. The reboot command may also contain an optional argument force that will cause the reader to reboot
even if a current operation is pending (such as a firmware download). If the force argument is absent, the reader will reject the
command if a current download is in progress. A help command entered at the command line interface will return the
following usage instruction:
> help reboot
reboot - Reboots the system.
Usage: reboot [force]
39
Page 40
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8.3.2. config Command
The config command leads to a submenu of configuration commands described further in section 8.4.
8.3.3. show Command
The show command leads to a submenu of elements that may have their configuration or status shown. See section 8.5.
8.3.4. transfer Command
The transfer command leads to a submenu of transfer commands described further in section 8.6.
8.4. Config Command
If a help config command is entered at the command line interface, the system will respond as follows to indicate the need to
enter subcommands:
> help config
config - Submenu of configuration commands.
Usage: config [<subcommand> ...]
Entering the config command, followed by help (or ?), brings up a submenu of configuration commands.
> config
config > ?
Commands:
access - Changes the password for a given access level.
CLI - Not handled yet.
rfid - Not handled yet.
exit - Exit this submenu and return to the parent menu.
Help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
image - Submenu of image and upgrade configuration commands.
logging - Submenu of logging configuration commands.
network - Submenu of network configuration commands.
system - Submenu of system info configuration commands.
8.4.1. config access Command
The config access command changes the password for a given access level. Only root is supported at present. Password
changes made via this command also change the user’s web password to the same value. The command parameters are shown
in Table 8-2.
Table 8-2 "config access" Command Parameters
Arguments Options Format Description
Level Root STRING Level of user to change (only root is supported)
Password STRING
40
Password to set account’s active password to (at least six
characters).
Page 41
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
The command usage is shown below:
Usage: access <level> <password>
A sample of the command and response is shown below:
The config image commands provide configuration options for image and upgrade configurations. It contains no sub-menus.
The commands are described below:
Commands:
factory - Revert to factory defaults.
fallback - Fallback to the previous image (if valid).
metafile - Perform an upgrade with a given metadata URI.
retrievemode - Perform an upgrade with a given URI.
upgrade - Perform an upgrade with a given URI.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
These commands will not take effect until the reader is rebooted. Detailed explanation of how to upgrade images is given in
section 7.
8.4.2.1. config image factory Command
This command, followed by a reboot, returns the reader to the factory default configuration associated with the current running
image and at the same time, removes the custom application partition. Once complete, the factory defaults do not take effect
until the system is rebooted. This command takes no parameter. Example command usage is shown below:
Usage: config image factory
During factory default, the show image summary (section 8.5.2.2) command reports the UpgradeStatus as Erasing,
Programming, or Done. After this command is processed, the reader will continue its operation with the current configuration
until a reboot command is issued. In the mean time, the metafile retrieve-mode is set to push (i.e., the factory default restore
command cancels a previously scheduled periodic upgrade). When the reader comes up from the reboot, it will run the same
SOP image version as the one from which it performed the factory default restore, with factory defaul t c on fig urat i o n an d no
custom application.
If the reader is in pull mode during the execution of this command, it is possible that the reader is currently retrieving the
metafile or performing an upgrade. In these instances, this command may return “Previous-Command-In-Progress”.
8.4.2.2. config image fallback Command
The successful processing of this command, followed by a reboot, returns the reader to the previous valid image. This
command takes no parameter.
Usage: config image fallback
If there is no valid previous image to fallback to, the command response will be “failure” with a reason “No Fallback Image
Available “, as listed in Table 8-14. After this command is successfully processed, the reader waits for a reboot command to
fallback to the previous image. In the mean time, the reader operates normally except that all the config image commands will
41
Page 42
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
be rejected with a reason “Current Image Invalidated”. Also the metafile retrieve-mode is set to push, i.e., the fallback
command cancels a previously scheduled periodic upgrade. When the reader is rebooted, the previous image will be activated.
If the reader is in pull mode during the execution of this command, it is possible that the reader is currently retrieving the
metafile or performing an upgrade. In these instances, this command may return “Previous-Command-In-Progress”.
Important A fallback will utilize all the old configuration settings, including the upgrade metafile settings as if the
upgrade to the newer image was never performed—which may trigger an immediate upgrade. If the URI of the
old metafile is known and an immediate upgrade is not desired, the user should remove or rename the old
metafile before performing a fallback.
8.4.2.3. config image metafile Command
This command takes the Universal Resource Identifier (URI) of the upgrade configuration metafile as the parameter. It
commands the reader to perform an upgrade using the metafile identified by the URI.
Usage: config image metafile <URI>
Upon receiving this command, the reader updates its local upgrade configuration URI, retrieves the upgrade configuration
metafile, and performs the upgrade in accordance with the metafile. If the upgrade is successful, how the new image is
activated depends on the commit-mode specified in the metafile (see Section 7.3, Table 7-1).
If the reader is in pull mode during the execution of this command, it is possible that the reader is currently retrieving the
metafile or performing an upgrade. In these instances, this command may return “Previous-Command-In-Progress”.
8.4.2.4. config image retrievemode Command
This command sets the reader’s metafile retrieve mode and (if applicable) the retrieve period (see Table 8-3). Whe n the
retrieve-mode is set to push, the reader will take no upgrade action. To perform an upgrade in this mode the user must issue a
config image upgrade command to directly download an upgrade image (see section 8.4.2.5).
Usage: config image retrievemode push
config image retrievemode pull <period-minutes>
<period-minutes> is how often the reader pulls the metafile
When the mode is pull, the reader periodically retrieves the metafile
from the most recent metafile URI at the rate specified by the
mode
retrieve-period INT
If this command results in a change from push to pull, or a change of retrieve-period while the current mode is pull, the reader
immediately attempts to download a new UConf metafile using its current metafile URI.
<pull
| push>
STRING
retrieve-period. In push mode the user must manually specify a
new metafile URI or manually upgrade the file to perform the
upgrade.
Interval of pull in minutes—only applicable when mode is pull. This
retrieve period is used only until the reader retrieves a valid
metafile, at which point the retrieve period from the metafile is
adopted.
8.4.2.5. config image upgrade Command
42
Page 43
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
This command is used to instruct the Speedway reader to directly download an upgrade image file and perform an immediate
upgrade. Upgrade image files are stored on a file server and retrieved by the Speedway reader from the location identified by
the URI.
Usage: config image upgrade <URI>
Upon receiving this command, the Speedway reader downloads the image file and, if the file is valid and eligible, performs the
upgrade. When this command is used, the upgrade will always be performed even if the version matches the current one.
If the upgrade is successful, the new image is not activated until the user reboots the system.
If the reader is in pull mode during the execution of this command, it is possible that the reader is currently retrieving the
metafile or performing an upgrade. In these instances, this command may return “Previous-Command-In-Progress”.
Note that this command does not change the reader’s upgrade configuration URI, but it sets the retrieve-mode to push, meaning
that the reader will not periodically retrieve upgrade configuration metafile until the retriev e-mode is set to pull again. See
section 8.4.2.4.
8.4.3. config logging Command
The config logging commands provide configuration op tions for remote syslog capture as well as internal Impinj log capture
via sub-menus. The internal log is stored in the RAM file system only, is capable of high-speed, real-time logging of internal
events, and is routed to the syslog based on the severity level (described below). The syslog is stored in the local Flash me mory
file system, is the standard Unix logging system, and is forwarded to a remote syslog server.
Logging levels may be set to one of eight options (in decreasing order from most severe to least): emergency, alert, critical,
error, warning, notice, info, and debug. Which data are forwarded from the internal Impinj (internallog) log capture to the
remote system logging (syslog) depends on the relative level settings. For example, if the internallog is set to the level of
“critical”, and the syslog level is set to “debug”, then all internal log data will be sent to the remote system capture because the
severity level of the internal Impinj log data will always be greater than the remote system log. Conversely, if the internallog
is set to “info” and the syslog is set to “alert”, then only internal log data with severity level of “alert” and higher will be
forwarded. The internallog data is still accessible via Rshell but it will not be stored in the syslog. See Figure 8-2.
The commands are described below:
Commands:
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
internallog - Submenu of internal logging specific commands.
syslog - Submenu of syslog specific commands.
43
Page 44
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Internal logSyslog
Logging
Data
Logging
Data
Figure 8-2 Relative Severity Level Logging Transfer
emergency
alert
critical
error
warning
notice
info
debug
emergency
alert
critical
error
warning
notice
info
debug
emergency
alert
critical
error
warning
notice
info
debug
SyslogInternal log
emergency
alert
critical
error
warning
notice
info
debug
Severity
Levels
8.4.3.1. config logging internallog Commands
The config logging internallog commands set the internal logging level for reader log events. These events can be viewed via
the show logging command or transferred off the reade r via the transfer command. The command parameters are shown in
Table 8-4. The set command sets the logging level for a log class to one of a set of pre-defined values.
Commands:
set - Configures internal logs.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
<level> is (emergency|alert|critical|error|warning|notice|info|debug)
A sample command that sets the RFID Access logging is shown below:
> config logging internallog set RFIDAccess emergency
Status=0,'Success'
Configures the level at and above which
ApplicationLevel logs are sent to the log
database. Listing in decreasing order of
severity.
8.4.3.2. config logging syslog Commands
The config logging syslog menu provides the configuration interface for the syslog module on the reader. If all remote syslog
servers are removed, the reader will begin to log in its internal memory. The command parameters are shown in Table 8-5.
Commands:
add - Add a server to the list of current syslog servers.
del - Delete a server from the list of current syslog servers.
delall- Delete all current servers.
level - Change the severity level of the messages to log via syslog.
reset - Removes all archived syslog messages.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
STRINGAdd a new syslog server with the following address
STRINGDelete a syslog server with the following address
STRING
Set the syslog security level. Only logs at or greater in severity
than this level will be forwarded to syslog. Levels listed in
order of decreasing severity.
8.4.4. config network Command
The config network menu allows the user to administer and manually provision the network settings for the reader. This menu
provides the following commands:
Commands:
domain - Set the domain of the reader.
hostname - Set the reader hostname.
snmp - Not handled yet.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
dhcp - Submenu of DHCP specific commands.
dns - Submenu of DNS specific commands.
ip - Submenu of IP address and configuration commands.
46
Page 47
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
ntp - Submenu of NTP specific commands.
trace - Submenu of network trace specific commands.
8.4.4.1. config network domain Command
The config network domain command configures a search domain on the reader device. This domain will be used if the
DHCP network does not provide a search domain to the device or the IP address mode is static. The command parameters are
shown in Table 8-6.
address mode is turned to static, this domain will be put
to use. If the STRING is absent, this command deletes
the static search domain.
8.4.4.2. config network hostname Command
The config network hostname command configures a hostname on the reader device—the hostname to be used if the DHCP
network does not provide a hostname to the device. The command parameters are shown in Table 8-7.
The config network dhcp command allows the user to modify the DHCP client configuration. The commands are described
below.
Commands:
sendhostname - Turn on/off send-hostname in DHCP client config.
userclass - Set the user class option of DHCP client config.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
Configures the current hostname for the reader.
Parameters returned from DHCP will override this value.
•If the sendhostname DHCP option is currently off and the command turns it on, the network interface is “refreshed”,
i.e., the DHCP client is restarted and the DHCP request is resent to get an IP address.
•If the userclass option is turned on or its value is changed, the network interface is refreshed.
Turn the “send hostname” on/off option in the
DHCP client configuration
Sets the value for the “send user-class” option of
the DHCP client configuration. Issuing this
command without giving a userclass string turns
this option off.
8.4.4.4. config network dns Command
The config network dns command allows the user to statically configure DNS servers. These servers are in addition to any
provisioned through DHCP. The comm ands are descri bed below.
Commands:
add - Add a static server to the list of current DNS servers.
del - Delete a statically configured server from the list of
current DNS servers.
delall - Delete all statically configured DNS servers.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
Command parameters are shown in Table 8-9:
Table 8-9 "config network dns" Command Parameters
Command Arguments Format Description
Add a static DNS server with the following address. Manually
add IpAddress IpAddress
del IpAddress IpAddress
delall
configured DNS servers will be utilized after searching DNS servers
returned by DHCP.
Delete a statically configured DNS server with the following address.
Servers obtained through DHCP are not available for delete.
Delete all statically configured DNS servers added with the add
command.
48
Page 49
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
The command usage is shown below:
Usage: config network dns add <server-ip-address>
Usage: config network dns del <server-ip-address>
Usage: config network dns delall
A sample command and response is shown below:
>config network dns add 1.2.3.4
Status=0,'success'
8.4.4.5. config network ip Command
The config network ip command allows the user to statically configure IP settings, or configure the reader to use DHCP. The
commands are described below.
Commands:
dynamic - Set the reader to DHCP for IP address parameters.
static - Set the reader to static IP address parameters.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
Command parameters are shown in Table 8-10:
Table 8-10 "config network ip" Command Parameters
Commands Arguments Format Description
Configure the network for static address resolution. The following
IpAddress
netmask
static
gatewayaddress
broadcastaddress
dynamic
The usage for this command is shown below:
Usage: config network ip static <ip-address>
Usage: config network ip static <ip-address> <gateway-address>
Usage: config network ip static <ip-address> <netmask> <gateway-address>
<broadcast-adddress>
The config network ntp command allows the user to statically configure NTP servers. These servers are in addition to any
provisioned through DHCP. The commands are shown below:
Commands:
add - Add a static server to the list of current NTP servers.
del - Delete a statically configured server from the list of
current NTP servers.
delall - Delete all statically configured NTP servers.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
The config network trace command sets up a remote network trace utility to redirect all traffic from the <source> to a
remote system. For example, it is possible to redirect all data transmitted and received on the external network connection to a
remote computer for analysis. When the trace is active, the data is transmitted in “libpcap” format to the remote system via a
TCP/IP connection. Since TCP/IP requires acknowledgement of packet data, an application (such as “netcat” in Linux/Unix)
must be running on the remote computer (on the desired port) to save all the data transmitted, otherwise the data will be
dropped and the trace will end. The commands are shown below:
Commands:
start - Start the remote network trace utility.
stop - Stops the remote network trace utility.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
A sample of the command and response is shown below:
> config network trace start external my_pc 2002
> Status=0,'success'
>
This command would start redirecting all external network traffic to <my_pc> port 2002 for analysis. Note that <my_pc>
must have a TCP/IP listener waiting on port 2002 to accept and store the data. For example, if my_pc is running Linux/Unix, it
is possible to use the “netcat” utility to listen on port 2002 and redirect the data to a file. Since this file is in “libpcap” format, it
may be directly opened with standard networking monitoring tools such as “tcpdump,” “ethereal,” or “wireshark.”
To stop an active redirection, enter:
> config network trace stop
> Status=0,'success'
>
51
Page 52
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8.4.5. config system Command
This menu allows configuration of the system identification parameters. Commands are shown below:
Commands:
contact - Configure the system contact.
description - Configure the system description.
location - Configure the system location.
name - Configure the system name.
time - Configure the system time.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
All system parameters are entered as strings except for time. Place single quotes around strings that have white space. Time
must be entered in one of the following formats:
Usage for the config system commands is shown below:
Usage: config system contact <contact-string>
Usage: config system description <description-string>
Usage: config system location <location-string>
Usage: config system name <system-name-string>
Usage: config system time <correctly formatted time>
A sample config system command is shown below:
config system > location 'a specific location identifier'
Status=0,'Success'
sysDesc="Impinj Speedway"
sysContact="http://www.supplier.com/techsupport"
sysName="speedway-00-00-06"
sysLocation="a specific location identifier"
time="Tue Apr 25 03:59:00 UTC 2006"
A sample command that sets time is shown below: (Time is set to April, 27
> config system time 042713112006
Status=0,'Success'
sysDesc="Impinj Speedway"
sysContact="http://www.supplier.com/techsupport"
sysName="speedway-00-00-06"
sysLocation="a specific location identifier"
time="Thu Apr 27 13:11:00 UTC 2006"
th
1:11:00 p.m. 2006.)
52
Page 53
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8.5. Show Command
If a help show command is entered at the command line interface, the system will respond as follows to indicate the need to
enter subcommands:
> help show
show - Submenu of elements that may have their configuration or status
shown
Usage: show [<subcommand> ...]
The show command brings up a submenu of configuration commands.
Commands:
CLI - Not handled yet.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
all - Submenu of multi-category info display commands.
image - Submenu of image status commands.
logging - Submenu of logging status commands.
network - Submenu of network status commands.
rfid - Submenu of RFID status commands.
system - Submenu of system status commands.
8.5.1. show all Command
The show all menu has the commands listed below.
Commands:
config - Summary of reader configuration.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
8.5.1.1. show all config Command
show all config is a summary of the static configuration entries of all categories. The static configuration entries are those that
are manually set via CLI commands. The entries that are obtained via such protocols as DHCP are considered dynamic and are
not displayed. The response of the command is the concatenation of all the static entries from the following four categories:
network, system information, upgrade agent, and logging. Each category is preceded with a delimiter field. The entire
collection of possible parameters is listed in Table 8-12. Note that some parameters are present only when set and applicable.
The command usage for show all config is shown below:
Usage: show all config
Table 8-12 "show all config" Response Parameters
Parameter Name Format Description
ConfigCategory Network Delimits the network category
DomainStatic STRING The statically set domain
NnsServerAddress<n>Stat IP Address
The nth static DNS server address. n starts
with 1.
53
Page 54
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Parameter Name Format Description
NtpServerAddress<n>Stat IP Address
IpAddressMode
<dynamic |
static>
IpAddress IP Address
IpMask IP Address
GatewayAddress IP Address
BroadcastAddress IP Address
Hostname
STRING The hostname of the reader
DhcpSendHostname <on | off>
DhcpUserclass DisplayString
ConfigCategory SystemInfo Delimits the system info category
SysDesc DisplaySring The system description
SysContact DisplaySring The system contact
SysName DisplaySring The system name
SysLocation DisplaySring The system location
ConfigCategory UpgradeAgentDelimits the upgrade agent category
MetafileUri DisplayString The URI of the upgrade metafile
RetrieveMode <pull | push> The upgrade agent‘s metafile retrieve mode
show all > config
Status=0,'success'
ConfigCategory=Network
domainStatic=
ipAddressMode=dynamic
hostname=speedway-00-02-01
The nth static NTP server address, n starts
with 1.
The IP address mode. Dynamic means DHCP
is used to obtain IP address.
The IP address of the reader’s Ethernet
interface. Present only if ipAddressMode is
static.
The IP subnet mask of the Ethernet interface.
Present only if ipAddressMode is static.
The default gateway IP address of the Ethernet
interface. Present only if the ipAddressMode is
static.
The broadcast address of the Ethernet
interface. Present only if the ipAddressMode is
static.
Indicates if the “send hostname” option of
DHCP client configuration is turned on
Displays the user-class option of the DHCP
client configuration. DisplayString is empty if
this option is not set.
The retrieve-period in minutes. Present only if
the RetrieveMode is pull.
The individual component’s syslog logging
level, as returned by the “show logging
summary” command.
The syslog logging severity level as set by the
“config logging syslog level” command
The first syslog server as set by the “config
logging syslog add” command.
The last syslog server as set by the “config
logging syslog add” command.
54
Page 55
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
sendHostname=on
userClass=''
ConfigCategory=SystemInfo
sysDesc='Impinj Speedway'
sysContact='unknown'
sysName='speedway-00-02-01'
sysLocation='unknown'
sysTime='Mon Aug 14 20:38:00 UTC 2006'
The show image sub-menus commands are shown below:
Commands:
metafile - Command to display upgrade metafile info.
summary - Command to display current image status.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
8.5.2.1. show image metafile Command
The show image metafile command displays the information for the current upgrade metafile. If no metafile has ever been
successfully downloaded, only the first two fields are available. The command parameters are shown in Table 8-13. The
command usage is shown below:
MetafileUri STRING The current upgrade metafile URI
RetrieveMode <pull | push> The current retrieve mode
RetrievePeriod INTEGER
UpgradeMode <auto | force> The upgrade mode if metafile is currently available
< immediate |
CommitMode
CommitTime DisplayString
EarlyActivateOk <yes | no>
UpgFileUri DisplayString
scheduled |
wait-4-cmd>
The current retrieve period, present only if retrieve
mode is pull. This is specified in seconds.
The commit mode if metafile is currently available
The schedule commit time, present only if commit
mode is scheduled. Its format is
<timezone-yyyy-mm-dd-hh-mm-ss>,
where time zone is the readers time which is gmt.
Indicates whether an early activation of the upgrade
image is valid when the commit is scheduled. Present
only if the metafile has the early-act-ok field.
The upgrade file URI, present if the current metafile is
available and has the upgrade-file-uri field.
8.5.2.2. show image summary Command
The show image summary command specifies the image summary information. The command usage is shown below:
The command returns the following (with all response parameters defined in Table 8-14):
Usage: show image summary
> show image summary
Status=0,'Success'
UpgradeStatus=Download Failed
Reason=File Not Found
DownloadFile=Upgrade Image
primaryImageType=2
primaryImageSystemVersion='2.0.1.240'
primaryImageConfigVersion='255.255.255.255'
secondaryImageType=2
secondaryImageSystemVersion='2.0.1.48'
secondaryImageConfigVersion='255.255.255.255'
56
Page 57
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 8-14 "show image" Response Parameters
Parameter Name Format Description
UpgradeStatus
Reason
<Idle | The reader is idle in terms of upgrade.
Contacting Server | Reader is contacting server for file download.
Downloading | File is being downloaded.
Download Failed |
Bad Config | The upgrade configuration metafile is invalid.
Bad Image | The image downloaded is invalid.
No Upgrade | No need to upgrade
Erasing |
Programming | Reader is programming new image into flash memory.
Done | Upgrade is complete.
Set Metafile Failed | The configureUri command failed.
Set Upgrade Failed | The updateUri command failed.
FDR Failed | The factory command failed.
Set RetrieveMode
Failed |
Failed >
This supplements the upgradeStatus field to give a reason for the status
<Unknown Host | Download failed because of an unknown host.
Unsupported
Scheme |
Syntax Error | Metafile has a syntax error.
Timeout | Download timed out.
File Not Found | Download file not found.
Access Denied |
Not Matching
Metafile |
Bad File Format | Bad upgrade image file format.
Bad CRC | Bad image CRC.
Bad Hw Version | Image Hw version does not match the reader.
No Newer Version |
File Mismatch | Metafile has mismatched partition image types.
No File | Metafile does not contain upgrade file information.
Missing SOP |
Duplicated Partition |
Incompatible
Upgrade/Downgrade
Path |
The upgrade status of the last executed upgrade
Failed to download either the metafile or the upgrade
image.
Reader is erasing flash memory before writing new
image.
The retrievemode command failed.
Any other failures not covered above. Usually
explained by Reason field
Download failed because of unsupported URI scheme
(only FTP, HTTP and TFTP are supported).
Download failed because of access denied by server,
e.g., bad password.
Bad upgrade image because of its not matching the
metafile.
Upgrade not needed because no newer version in the
metafile or upgrade image.
Metafile does not contain SOP partition while SCP is
present.
Upgrade failed because either the metafile or the
upgrade file has a duplicated partition in it.
Upgrade failed because upgrading/downgrading to the
intended SOP version or type is not allowed by current
image.
57
Page 58
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Parameter Name Format Description
Flash Programming
Failed |
Flash Programming
Failed |
Current Image
Invalidated |
No Fallback Image
Available |
Generic Error >
PrimaryImageType STRING
PrimaryImageSystemVersion STRING
PrimaryImageConfigVersion STRING
SecondaryImageType STRING
secondaryImageSystemVersion STRING
secondaryImageConfigVersion STRING
Following an upgrade command, the UpgradeStatus can take any of the values shown in Table 8-14. For each abnormal
status, a Reason parameter is given to indicate the reason for the status. The reason values are also given in Table 8-14.
Failed to write the flash memory.
Failed to burn the flash.
The current image has been invalidated by a previous
“fallback” command.
This reason applies to the rejection of multiple
commands following a “fallback” commands.
Download error other than those specified above.
The type of image stored in the primary (currently
defaults to Linux)
The version string of the primary image system
partition
The version string of the primary image configuration
partition
The type of image stored in the secondary (currently
defaults to Linux)
The version string of the secondary image system
partition
The version string of the secondary image
configuration partition
58
Page 59
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
8.5.3. show logging Command
The show logging commands are used to display the logging parameters for the system and for displaying the log information
in text form. The commands are described below.
Commands:
internallog - Displays the last internal log entries.
summary - Displays the current logging levels of the internal logs.
syslog - Displays the last syslog log entries.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
8.5.3.1. show logging internallog Command
Format for the show logging internallog command takes an integer argument to specify how many of the last internal log
entries to display. The command usage is shown below:
Usage: show logging internallog <eventcount>
An example command is shown below:
> show logging internallog 1
Status=0,'Success'
Event1=1156073965.245217 -- UpgradeAgent LAPI
Logging service started at: Sun Aug 20 11:39:25 2006
>
Log entries are reported from most recent to oldest. Response parameters for the show logging <syslog|internallog> are
shown in Table 8-15.
ConfigurationLevel Log level for configuration
MgmtLevel Log level for management
NetworkLevel Log level for networking
RFIDParameters Log level for RFID parameters
RFIDSingulation Log level for RFID singulation
RFIDAccess Log level for RFID access
System Log level for system
The level at and above which application-level
logs are sent to the log database
The syslog security level. Only logs at or above
this level will be forwarded to syslog.
8.5.3.3. show logging syslog Command
Format for the show logging syslog command takes an integer argument to specify how many log entries to display. The
command usage is shown below:
Usage: show logging syslog <eventcount>
An example command is shown below:
> show logging syslog 3
Status=0,'Success'
Event3=Aug 20 11:39:25 (none) ntpd[625]: bind() fd 4, family 2, port 123,
addr 10.0.10.231, in_classd=0 flags=1 fails: Address already in use
Event2=Aug 20 11:39:26 (none) thttpd[631]: socket :: - Address family not
supported by protocol
Event1=Aug 20 11:39:54 (none) dhclient: receive_packet failed on ixp0:
Network is down
8.5.4. show network Command
The show network menu contains commands to display networking parameters and statistics. All commands are single word
commands and take no arguments. Commands with their usage format are shown below, while the response parameters are
shown in Table 8-17 through Table 8-26.
60
Page 61
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Commands:
dhcp - Summary of DHCP Client configuration.
dns - Summary of DNS settings.
icmp - ICMP statistics.
iface - Interface status.
ip - IP statistics.
ntp - Summary of NTP settings.
snmp - Not handled yet.
summary - Summary of network settings.
tcp - TCP statistics.
trace - Status of current net trace activity.
udp - UDP statistics.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
The command usage for show network dhcp is shown below:
The command usage for show network dns is shown below:
Usage: show network dns
Indicates the current setting for
sending the hostname during
DHCP negotiation.
Displays the current setting for the
user class DHCP option. If this is
an empty string the user class
option is not sent via DHCP.
Otherwise the value indicates the
string that is sent.
61
Page 62
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 8-18 "show network dns" Response Parameters
Parameter Name Format Description
DomainStatic STRING
domainDynamic STRING
dnsServerAddress1Stat IpAddress Address of first static DNS server
dnsServerAddress2Stat IpAddress
… … …
dnsServerAddress<N>StatIpAddress
dnsServerAddress1Dyn IPAdress
… … …
dnsServerAddress<N>DynIPAdress
The command usage for show network icmp is shown below:
Usage: show network icmp
Statically configured domain, if
available
DNS domain obtained from DHCP,
if available
Address of second statically added
DNS server
Address of last statically added
DNS server
Address of first dynamic DNS
server obtained from DHCP server
Address of last dynamic DNS
server obtained from DHCP server
The command usage for show network ntp is shown below:
Usage: show network ntp
Table 8-22 "show network ntp" Response Parameters
Parameter Name Format Description
NtpServerAddress1Stat STRING
NtpServerAddress2Stat STRING
… … …
NtpServerAddress<N>StatSTRING
NtpServerAddress1Dyn STRING
NtpServerAddress2Stat STRING
… … …
NtpServerAddress<N>DynSTRING
A sample command is shown below:
> show network ntp
Status=0,’success’
NtpServerAddress1Stat=140.142.16.34
The command usage for show network summary is shown below:
Usage: show network summary
Address of the first statically
added NTP server
Address of the second
statically added NTP server
Address of the last NTP
server
Address of the first NTP
server obtained from DHCP
server
Address of the second
dynamic NTP server
obtained from DHCP server
Address of the last NTP
server obtained from DHCP
server
show network > trace
Status=0,'Success'
Active=No
>
if a net trace is currently
active.
8.5.5. show system Command
The show system menu displays information on the system state of the reader. Command usage for each subcommand is
shown below and Table 8-27 through Table 8-29 summarize the respective response parameters. Examples for each follow.
Commands:
cpu - Platform memory usage and available application space
statistics.
platform - Displays generic platform statistics.
summary - Displays system information
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
67
Page 68
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
The command usage for show system cpu is shown below:
Usage: show system cpu
Table 8-27 "show system cpu" Response Parameters
Parameter Name Format Description
TotalMemory Unsigned32Total available RAM in bytes
FreeMemory Unsigned32Total free RAM in bytes
CpuUtilization Unsigned32CPU utilization in percent
TotalConfigurationStorageSpace Unsigned32Total Configuration partition space in bytes
FreeConfigurationStorageSpace Unsigned32Free Configuration partition space in bytes
TotalApplicationStorageSpace Unsigned32Total Application partition space in bytes
FreeApplicationStorageSpace Unsigned32Free Application partition space in bytes
> Show system cpu
Status=0,'success'
TotalMemory=64606208
FreeMemory=45469696
CpuUtilization=3
TotalConfigurationStorageSpace=2097152
FreeConfigurationStorageSpace=1335296
TotalApplicationStorageSpace=2097152
FreeApplicationStorageSpace=1437696
The command usage for show system platform is shown below:
Usage: show system platform
Table 8-28 "show system platform" Response Parameters
Parameter Name Format Description
hardwareVersion Display StringReturns the current hardware version information
serialNumber Display String Returns the hardware serial number
bIOSVersion Display StringReturns the version information for the reader BIOS
MacAddress Display StringMAC Address of unit’s Ethernet port
UptimeSeconds <Time ticks> Time since last reboot in seconds
> show system platform
Status=0,'success'
hardwareVersion=010-000.027255
serialNumber=00-06-02-00022
biosVersion=1.1.0 RC 2
macAddress=00:16:25:00:01:18
uptimeSeconds=5836
The command usage for show system summary is shown below:
Usage: show system summary
68
Page 69
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Table 8-29 “show system summary” Response Parameters
Parameter Name Format Description
SysDesc DisplayString
SysContact DisplayStringThe system contact information – defaults to unknown
SysName DisplayString
SysLocation DisplayStringA system location – defaults to ‘unknown’
SysTime DisplayStringA time in UTC
> show system summary
Status=0,'Success'
sysDesc=’Impinj Speedway’
sysContact=’unknown’
sysName=’speedway-00-00-08’
sysLocation=’unknown’
sysTime=’Tue Apr 25 16:04:59 UTC 2006’
A system description; defaults to make and model
number of reader
A system name – defaults to speedway-nn-nn-nn where
nn-nn-nn are the last three octets of the MAC address.
8.6. Transfer Command
If a help transfer command is entered at the command line interface, the system will respond as follows to indicate the need to
enter subcommands:
> help transfer
transfer - Submenu of transfer commands.
Usage: transfer [<subcommand> ...]
The transfer menu contains commands for transferring files from the reader. Syslog and internal log files stored on the reader
can be offloaded to remote servers. The transfer commands have the following format:
Commands:
from-reader - Transfer a file from the reader to a remote URI.
status - Display status of any currently active transfer.
exit - Exit this submenu and return to the parent menu.
help - Displays this help message.
. - Exit this submenu and return to the parent menu.
? - Displays this help message.
Sub-menus:
None
8.6.1. transfer from-reader Command
The transfer from-reader command uploads files from the reader. The command requires two arguments: the first specifies
the file to upload, the second specifies the URI destination for the file. The file upload options are internallog or syslog. The
internallog and syslog options upload the internal log and syslog, respectively, to a file specified by the URI that must end in
.txt.gz. The command usage is shown below:
Usage: from-reader <internallog|syslog> <URI>
The following URI formats are accepted by this command:
> transfer from-reader syslog tftp://10.0.10.37/syslog.txt.gz
Status=0,'Success'
>
8.6.2. transfer status Command
The transfer status command displays the current status of the transfer sub-system. The command usage is shown below. The
command response parameters are given in Table 8-30 . T hi s command takes no arguments.
Usage: transfer status
Table 8-30 “transfer status“ Command Response
Parameter
Name
TransferStatus
Reason
An example of a failed transfer has the following status response:
Format Description
<Unknown |
Contacting Server |
Transferring |
Transfer Failed |
Done>
< Unknown Host |
Access Denied |
File Not Found |
Timeout |
Invalid URI Format |
Invalid URI Format
(username:password@host)>
> transfer status
Status=0,'Success'
TransferStatus=Transfer Failed
Reason=Unknown Host
>
The status of the transfer. Unknown means there is no
outstanding transfer command.
Reason for failure of transfer.
Note that when using TFTP to upload, the remote file
may have to be already on the server with the right
permission, otherwise transfer fails with reason “File
Not Found” or “Access Denied”.
If the remote URI is invalid, transfer fails with reason
“Invalid URI Format” and if FTP is used, the correct
form is given in the Reason string.
70
Page 71
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
9. Troubleshooting
Refer to Table 9-1 for resolution of common problems. For additional technical support, go to http://rfid-support.impinj.com.
For units not purchased directly from Impinj, please contact your VAR directly.
Table 9-1 Troubleshooting
Problem Solution
Most likely the reader operating system is still booting or
TCP/IP connectivity has been lost. Retry or “ping” the
The reader’s default page does not load.
Java applet does not load after selecting “RFID” from
default page.
“Initializing” or “Calibrating” dialog boxes do not
disappear.
Tags/sec rate varies when configuration settings are
changed.
None of the recommend actions fixes the problem. Power-cycle the reader
reader to verify connectivity. If more than 50 seconds
have elapsed since power was applied, disconnect and
reconnect power, then re-attempt to ping the unit after 50
seconds.
Verify that the PC’s web browser has Java Runtime
Environment (JRE) of version 1.4.2 or later. The latest
version of JRE may be installed from:
http://java.com/en/download/manual.jsp
The reader has likely locked up. Power cycle the reader.
This is normal. Currently, the Maximum Throughput
mode should have >200 tags/sec, while Dense-Reader
or Initialization modes are ~100 tags/sec. Some transmit
frequencies will be better than others (no interference or
less noise). Best rates will be achieved with 10 to 30 tags
within range.
10. References
Reference Description
MIB-2 RFC 1213 Management Information Base for Network Management of
TCP/IP-based internets:MIB-II. K. McCloghrie, M. Rose.
March 1991.
RFC 3986 Uniform Resource Identifier (URI): Generic Syntax. T.
Berners-Lee, R. Fielding, L. Masinter. January 2005.
71
Page 72
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Appendix A Impinj Factory Default Configuration
Detailed below are the factory default configuration settings for the Speedway reader. Except for the username and password,
all entries are shown when the “show all config” command is issued on a Speedway reader in its factory default configuration.
Username: root
Password: impinj
Networking Category
Static domain: None
IpAddressMode: dynamic # (using DHCP to obtain IP address)
hostname: speedway-nn-nn-nn, # where nn-nn-nn are the last three bytes of the reader's MAC address (in hex)
SendHostname: on
Userclass: None
Static DNS server: None
Static NTP server: None
System Info category:
system Description: 'Impinj Speedway'
system Contact: 'http://www.supplier.com/techsupport'
system name: 'speedway-nn-nn-nn' # same as default hostname
system Location: 'unknown'
KEY_RIGHT Control-F, \033[C
KEY_HOME Control-A, \033[1~ Move cursor to begin-of-line.
KEY_END Control-E, \033[4~ Move cursor to end-of-line
KEY_DELETE Control-D, \033[3~
KEY_BACKSPACE Control-H
KEY_ERASELINE Control-U
KEY_ENTER Control-J, Control-M
KEY_UP Control-P, \033[A
KEY_DOWN Control-N, \033[B
anything else Ignored
position then move cursor
right one.
Move cursor left one. Sticks
at begin-of-line.
Move cursor right one. Sticks
at end-of-line.
Delete character at cursor
position. Leave cursor at
same position.
Move cursor left one then
same as KEY_DELETE. Does
nothing at begin-of-line.
Erase entire line, place
cursor at begin-of-line
Move cursor to end-of-line.
Return the line to the caller
for processing.
Move up (earlier) the history
list. Erases current line,
copies in and displays
history entry, places cursor
at end-of-line.
Move down (later) the history
list. Erases current line,
copies in and displays
history entry, places cursor
at end-of-line.
73
Page 74
Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
Appendix C Power Supply Specifications1
Parameter Specification
Input
Rated input voltage 100 V ~ 240 V ac
Input voltage range 90 V ~ 264 V ac
Rated frequency 50~60 Hz
Frequency range 47~63 Hz
Rated input current 1.5 A at 115 / 0.75 A at 230 V ac (full load)
Inrush current
nominal ac input voltage at full load, 25°C, cold start
(no damage will occur and the input fuse will not blow)
Output
Output voltage 24 V dc at 2.5 A
Output min. current 0 A
Line regulation ± 2%
Load regulation ± 5%
Over voltage protection ≤ 31 V dc max. with zener clamp
Over current protection ≤ 5 A (with auto-recovery function)
Short circuit protection a short circuit at the dc output to ground will cause no damage
Ripple voltage
Efficiency 80% min. (at nominal input voltage and full load)
Safety and EMI
HI-POT
Safety approvals
EMI standard FCC part 15 class B, C-Tick, CE (EN55022)
RoHS compliant yes
Leakage current 0.25 mA
Environmental
240 mV (p-p) (at 20 MHz and output parallel with 0.1 µF and 10 µF
capacitors to ground.)
input to output 1500 V ac or 2121 V dc at 10 mA for 1 min.
primary to ground 1500 V ac or 2121 V dc at 10 mA for 1 min.
UL/cUL (UL60950-1), TUV/GS (EN60950-1), T-license (EN60950-1),
SAA (AS/NZS60950)
Cooling by natural convection
Storage temperature -20°C ~ +60° C
Operating temperature 0°C ~ +40° C
Storage humidity 5~95% RH (non-condensing)
Operating humidity 20~85% RH (non-condensing)
Reliability
Mean time before failure (MTBF)
Burn-in test 4 hours at 40°C max., nominal input voltage, 80% of max. load
1
Valid data as of December 2006
74
the power supply is designed and produced to have a mean time
between failures (MTBF) of 50,000 hours while operating under the
following conditions: 80% max. load at 25°C, nominal input voltage.
The information contained in this user guide is confidential and proprietary to Impinj, Inc. This document is conditionally
issued, and neither receipt nor possession hereof confers or transfers any right in, or license to, use the subject matter of any
drawings, design, or technical information contained herein, nor any right to reproduce or disclose any part of the contents
hereof, without the prior written consent of Impinj and the authorized recipient hereof.
Impinj reserves the right to change its products and services at any time without notice.
Impinj assumes no responsibility for customer product design or for infringement of patents and/or the rights of third parties,
which may result from assistance provided by Impinj. No representation of warranty is given and no liability is assumed by
Impinj with respect to accuracy or use of such information.
Impinj products are not designed for use in life support appliances, devices, or systems where malfunction can reasonably be
expected to result in personal injury, death, property damage, or environmental damage.