Imperial LD900 User Manual

Refrigerant Gas Leak Detector
Detects all HFO, HFC, HCFC, and CFC
Refrigerants including blends
WARRANTY
The LD900 Refrigerant Gas Leak Detector is warranted to be free of defects in materials and workmanship for a period of two years from the date of purchase. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorized opening of the unit. Tools should be returned to the buyer’s place of purchase.
SERVICE/TECHNICAL QUESTIONS CALL TOLL FREE: 888.467.8665
30333 Emerald Valley Pkwy. • Glenwillow, Ohio 44139 • 888.467.8665
REPLACEMENT PARTS
Item Part Number
Sensor with Sensor Tip & Filter S77694
Sensor Filters (5 pack) S77695
Leak Test Vial S77696
Sensor Tip with Filter S77698
Parts Kit (includes sensor, test vial, & lter kit) S77697
Carrying Case S77699
LD900
User Manual
www.imperial-tools.com
info@stridetool.com
Design certied by ASCI
and Intertek to meet SAE
J2791 & ASCI J2913,
EN14624-2012 & ASHRAE
173-2012
Made in U.S.A.
LeakDetectors-LD900-UserManual.indd 1-1 12/7/16 1:08 PM
INTRODUCTION
The LD900 features a long life solid electrolyte sensor technology that is designed to detect more current and difcult HFC refrigerants such as R-134a, R-410A, R-404A, R-407A, and R-507 in addition to the new HFO-1234yf and all HCFC (R-
22) and CFC (R-12) refrigerants including SNAP approved hydrocarbon blends.
Our unique digital leak size indicator takes the guesswork out of whether to repair a small leak. The digital display is independent from the audio alarm and sensitivity level, allowing the precise pinpointing of the leak source.
The LD900 does not require rechargeable batteries.
FEATURES
• Unique numeric leak size indicator
• Long life, stable sensor
• R-134a sensitivity .05 oz/yr
• R-1234yf sensitivity .015 oz/yr
• R-22 sensitivity .025 oz/yr
• Design certied to meet SAE J2791, SAE J2913, European EN14624
• Automatic calibration and reset to ambient
• Visual LED leak alarm near sensor
• 3 adjustable sensitivity levels
• Low battery indicator
• True mechanical pump
• Audio mute function
• Uses 4 AA alkaline batteries
• CE Certied
• Comfortable Sanoprene grip
• 2-year warranty includes sensor
• Made in USA
OPERATING INSTRUCTIONS
1. TURN ON: Press the ON/OFF button once to turn on and again to turn off.
NOTE: Hold button down for approximately 1 second to turn unit off.
2. WARM UP: The detector automatically starts heating the sensor. During the heating cycle, the digital leak size indicator will ash 0 and the detector will sound a slow “beep”. Warm up time is usually less than 20 seconds.
3. READY: The detector is ready to begin searching for leaks when the ashing 0 stops and the green sensitivity LED turns on. The audio “beep” increases in frequency and the probe LED begins to blink steadily.
4. SEARCHING: When searching for leaks, move the sensor tip along A/C lines and ttings no further away than 0.4 in. (9.5 mm) and no faster than 3 in./sec. (75 mm/sec.) If the detector alarms, make smaller sweeps back and forth until the leak source can be pin pointed. NOTE: The LD900 only responds to changes in leak concentration. The alarm will re-set automatically if the sensor tip is held at the leak source. If the leak detector has been out of use for an extended period, weeks or months, the following action is recommended. Power on the instrument and allow it to come out of warm up. Then run it with the sensitivity level in the Hi (high) position for several minutes before testing it with the Leak Test Vial. This action will guarantee that the sensor is fully conditioned for maximum response to refrigerant gas.
Digital Leak Size Indicator
Low Battery Indicator Sensitivity Level Indicators Audio Mute & Sensitivity Level Selectors Power On/Off
LD900 CONTROL PANEL
2 3
LeakDetectors-LD900-UserManual.indd 2-3 12/7/16 1:08 PM