Imperial G3042PS1WH, G3048SD4WH, G3042SD4BLSS, G3036SD4WHSS, G3036PS1BL Installation Manual

...
Flush Mount—3000 & G3000
Installation Instructions
&
FLSH/7.17
Warranty Information
Brea, CA 92821
www.imperialhoods.com
(800) 851-4192
DO NOT THROW AWAY,
PROPERTY OF THE HOME OWNER!
Imperial Cal Products, Inc.
Any cosmetic defects must be reported to us prior to installation. Once this hood is installed, ICP will NOT accept any responsibility
for any cosmetic blemishes, scratches or dents in the Canopy.
Save all original packaging if you wish to return for any reason!
FIRST:
Check your local building and electrical codes.
WARNING:
To reduce the risk of fire or electrical shock, Do Not use any two speed motor units with a Solid State control devise.
CAUTION:
To reduce the risk of fire or personal injury and to properly exhaust air, be sure to duct air to the outside. DO NOT vent exhaust air into spaces within wall, attics, ceilings, crawl spaces or garages. When venting to the outside make duct run as short and straight as possible. Avoid using elbows if at all possible as this will reduce your performance. Every elbow will decrease the performance and we will not guarantee the effectiveness of the range hood.
No Performance Warranty when used above BBQ Style Grills.
DO NOT use duct pipe smaller than the outlet duct opening on the hood, this will reduce performance and void the warranty. DO NOT use flex ducting. Also, use either a Roof Cap or Wall Cap to end run. Be sure that all joints are taped securely in place. It is essential to have the proper distance between the bottom of the range hood and the cooking surface below. In most cases the cooking appliance manufacturers specifications will establish the fire safe minimum distance required, although there are other factors to consider:
 Local Building Codes  Cross directional air movements ie: open windows, air conditioning/heating outlets, cooling
fans, etc.
 Overall size of the cooking appliance and surrounding countertop surfaces.  Range hood model selected.
For best performance, distance between cooking surface and the bottom of the hood is 30” and 36”. Check local codes and appliance specifications. Keep in mind, increasing the distance will decrease the performance. PS1 is equipped with a thermostat. Unit will automatically turn on
to the highest setting when 130 degrees is reached. (Not available in SD4 or SD2 models)
PARTS INCLUDED:
(4) 10-32 2” Sltd. Round Screw
(4)1-1/4 Fender Washer
(4) 10-32 Wingnuts
(4) 10 F/W Stand Washer
Read Before Starting Installation!
Inspect your range hood prior to installing!
(2) Large Aluminum Mesh Filters (2) Smaller Aluminum Mesh Filters
Flush Mount Installation Details:
MODELS: MODELS: MODELS:
G3000SD2 G3000SD4 G3000PS1 3000SD2 3000SD4 3000PS1
CABINET: Be sure cabinet bottom is level, side to side and front to rear.
 For the “SD” units prepare cabinet by cutting an 8” x 8” hole in bottom, 3/4” from wall
and on Center line.
 For the “PS1” units prepare the cabinet by cutting a 10 3/8” (D) x 20 1/4” (W) hole in
the bottom, 1/2” from wall and center line.
 Shelves and top to be cut to clear 7” round pipe. Make sure to cut holes for electrical
wires.
NOTE: Bolts, washers and nuts supplied. Remove the Drawer before positioning the hood under the cabinet. (See next page on how to remove drawer.)
 Remove Black Tape that holds dampers in closed posi-
tion. *It is NOT recommended to use 2 dampers during installation. You have the option to put a external damper or use the existing damper already on the unit.
 Position hood against cabinet bottom and against the wall.
Mark the underside of cabinet through each key-hole for location of each bolt hole.
SD2 or SD4
 Drill 3/16” holes through cabinet bottom. Insert bolts with small
washer under head of bolt through cabinet bottom from inside the cabinet.
 Again, position hood under cabinet with bolts through
key-holes. Starting with front key-holes, place large washer on bolt, attach the wing-nut to bolt, secure both front wing-nuts. Push hood back against wall, secure large washer and the
wing-nuts on rear bolts.
PS1
 Re-install the drawer.  Connect duct and tape all joints.  Replace Filters
ELECTRICAL:
 Bring enough wire into cabinet to reach in front of vent pipe.
Black Tape on Damper
 Enter the cabinet 3 1/4” left of center for (SD unit) or 2 1/4” for the (PS1 unit).  Remove electrical box cover before mounting the hood.  After hood is mounted attach house wires to leads in hood.  Secure locknut to conduit and check wiring for compliance with all local codes.  Replace electrical box cover.
Duct Sizes Indicated in Model # (Ex: 3030PS1-8)
** - 8 = 8” DUCT PIPE
PROPERTY OF HOME OWNER, DO NOT THROW AWAY!
Flush Mount Installation Details:
MODELS: MODELS: MODELS: G3000SD2 G3000SD4 G3000PS1 3000SD2 3000SD4 3000PS1
TO REMOVE DRAWER FROM 3000
A) Pull out drawer until it stops. B) Press down drawer top at the point indicated by arrow “A” to release safety
clip, while pulling the drawer outward.
WHEN THE DRAWER STOPS AGAIN… C) Press two black buttons on left and right slides indicated by arrows marked “B” .
D) Pulling the drawer outward. Drawer will come free of hood, HOLD SECURLEY!
WOOD PANEL:
To determine the size of your front Wood Panel you must take two things into consideration:
 Actual size of the hood itself  Design of surrounding cabinets
You want to hide the hood and to do so you need it to line up with the surrounding cabinets. We suggest you extend the Height and Width of the Wood Panel a bit beyond the actual size of the hood. So if you have a 36” hood your wood Panel might be 36.5” Wide by 6.5” High. The final choice on the size must be determined by your cabinet maker and yourself.
Imperial Cal Products, Inc.
To order replace parts or schedule service please call our office at (800) 851-4192.
PARTS:
When ordering Parts we need the following information:
 Model Number (not serial number) found on receipt of purchase or Series listed
on the UL label inside hood.
 Filters—provide Exact Dimensions
You can find the model number on the inside of your hood on our UL label. There will be a several model numbers listed, your model number should have a colored dot or mark next to it to indicate the exact model you have.
In the case of Filters, we will need the exact dimensions of the filter needed. Indicate which side has the pull tabs on it. Filters are not a warranty replacement part. With care your filters should last many years.
Payment on Parts is handled one of three ways: PrePaid (you send a check prior to our Shipping), call with credit card information, VISA or MasterCard, COD or Cash if you decide to “Will Call”. Our Will Call hours are 8:30 to 3:30, Monday through
Friday.
SERVICE:
When calling in for Service we need the following information:
 Model Number (not serial number)  Proof of Purchase  Name of company you purchased the hood through.  Name & Phone number of the person to contact to set up the service call.  Full address of the location where service is to be done.
Warranty is Seven Years, Parts and Labor.