Imperial ELECTRIC HOT PLATES Owners Manual Installation, Operation, & Maintenance Instructions

INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.
SHIPPING DAMAGE CLAIM PROCEDURE
The equipment is inspected & crated carefully by skilled personnel before leaving factory. The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment. If shipment arrives damaged:
1. Visible loss or damage: Note on freight bill or express delivery and have signed by person making delivery.
2. File claim for damages immediately: Regardless of extent of damages.
3. Concealed loss or damage: If damage is noticed after unpacking, notify transportation company immediately and file
“Concealed Damage” claim with them. This should be done within fifteen (15) days from date delivery is made to
you. Retain container for inspection.
1128 Sherborn Street ▪ Corona, CA 92879-2089 ▪ (951) 281-1830 ▪ FAX (951) 281-1879
IMPORTANT
OWNERS MANUAL
®
ELECTRIC HOT PLATES
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
Electrical wiring from the electric meter, main control box or service outlet to appliance must be electrically grounded in accordance with local codes, or in the absence of service of local codes, with the National Electrical Code ANSI/NFPA 70-(latest edition). Canada, conform with Canadian Electrical Code CSA-C22.2.
IMPORTANT
Installing, Operating and Service Personnel:
Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with and experienced in state/local installation codes. Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar with the function of the equipment. Service of the equipment should be performed by qualified personnel who are knowledgeable with Imperial Ranges.
1
SIDES 6 0
BACK 6 0
KEEP THESE INSTRUCTIONS FOR FUTURE USE
GENERAL
Imperial suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided. Your Imperial unit is produced with high quality workmanship and material. Proper installation, usage and maintenance of your unit will result in many years of satisfactory performance.
Standard surface plates are solid cast iron 9 ½” (241 mm) diameter,
INSTALLATION
Before installing, check the electrical service to make sure it agrees with the specifications on the rating plate located in the lower left hand side of the oven under the kick plate. If the supply and equipment voltages do not agree, do not proceed with the installation. Contact your dealer or Imperial Commercial Cooking Equipment immediately.
INSTALATION CODES AND STANDARDS
Your Imperial unit must be installed in accordance with:
In the United States of America:
1. State and local codes
2. NFPA Standard #96 Vapor Removal from Cooking Equipment, (latest edition) available from the National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269
In Canada:
1. Local code
2. Canadian Electrical Code C22.1 Part 1 (latest edition) available from the Canadian Standard Association,
5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada, L4W 5N6.
LEG ASSEMBLY
Attach the legs to the body by threading the exposed leg stud into the threaded holes located on the underside of the unit. Tighten each leg so that the top face of the leg is pressed firmly against the body bottom.
LEVELING
Position the unit in the desired location. Level the unit by using a wrench to turn the adjustable feet. You must hold the leg while turning the foot so that its attachment to the unit is not loosened.
LOCATION
The installation location must allow adequate clearance for servicing and proper operation. A minimum front clearance of 40” (1016 mm) is required. 0” side and rear clearance from non-combustible 6” from combustible construction.
INSTALLATION CLEARANCES
COMBUSTIBLES NONCOMBUSTIBLES
2