Ensure it is in the upright position for a MINIMUM of 6
hours and a RECOMMENDED time of 24 hours before powering on the first time.
ADVERTENCIA:
Para evitar daños permanentes a la
unidad:
Asegúrese de que está en la posición vertical durante
un mínimo de 6 horas y un tiempo recomendado de 24
horas antes de encender la primera vez.
Spanish version of this manual available for download on
www.impecca.com
Read the following notices and information carefully to ensure proper operation of your air
conditioner unit.
This manual is solely provided for informational purposes and in no way constitutes a legally
binding document between the manufacturer, distributor, and end consumer. Exact appearance of your unit may dier from the pictures and diagrams enclosed.
Lea las siguientes indicaciones cuidadosamente para asegurar el correcto funcionamiento
de su unidad de aire acondicionado.
Este manual se proporciona únicamente con fines informativos y de ninguna manera
constituye un documento jurídicamente vinculante entre el fabricante, distribuidor y
consumidor final. Apariencia exacta de su unidad puede diferir de las imágenes y esquemas adjuntos.
Garantía Limitada Por Un Año (US) ................................................................................... 23
Garantie Limitée D’un An (US) ............................................................................................ 24
ENGLISH
–iii–
ENGLISH
READ THESE NOTICES CAREFULLY—THEY ARE IMPORTANT!
WARNING
Plug in power plug completely.
• Otherwise, it may cause electric shock or
fire due to potential short circuit.
Do not modify power cord length.
• It may cause electric shock or fire.• It may cause electric shock.• This could be harmful to their health.
Always ensure eective grounding/
earthing.
• Incorrect or missing grounding may lead to
electric shock.
Unplug the unit if it emits strange sounds,
smells or smoke.
• Unit may need repair. • It may cause fire and electric shock.• It may cause electric shock.
Ensure the power cord is kept away from
any heating sources.
• It may cause fire and electric shock.• It may cause failure and electric shock.• It may cause an explosion or fire.
Ventilate room before operating
air conditioner if there was a gas leakage.
• It may cause explosion, fire, and burns.
Do not start or stop the unit by inserting or
pulling out the power plug.
• It may cause electric shock or fire.
Do not operate with wet hands or in a
damp environment.
Do not allow water into or onto the front of
cabinet, control panel or power cord.
• It may cause failure of unit or electric shock.• Sharing a circuit can lead to fire.
Do not plug unit into an electrical socket
that is loose or damaged.
Do not disassemble or modify unit.
Do not damage power cord or replace
with a non-original power cord.
• It may cause electric shock or fire.
• If the power cord is damaged, it must
be replaced by the manufacturer or an
authorized service center or a similarly
qualified person to avoid hazard.
Do not direct airflow directly at room
occupants.
Always use dedicated power outlet and
circuit breaker.
Do not operate the unit while the
chassis is open or removed.
Do not use the power cord near
flammable gas or combustibles, such as
gasoline, benzene, paint thinner, etc.
When the air filter is removed for cleaning,
avoid touching the internal metal parts of
the unit.
• It may cause an personal injury and/or
damage to the unit.
When the unit is to be cleaned, power o
the unit and circuit breaker.
• Do not clean unit when power is on as it
may cause fire and electric shock and/or
personal injury.
CAUTION
Do not clean the air conditioner with water.
• Water may enter the unit and degrade the
insulation. It may cause an electric shock.
Do not put a pet or house plant where it
will be exposed to direct air flow.
• This could injure or be harmful
to your pet or plants.
–4–
Ventilate the room well when used
together with a stove, etc.
• An oxygen shortage may occur when
using a stove in a room with closed
windows.
Do not use for specialized purposes.
• Do not use this air conditioner to
preserve precision devices, food, pets,
plants, and art objects.
• It may cause deterioration, etc.
CAUTION
Stop operation and remove unit from
window in severe storm or hurricane.
• Operation during a severe storm may allow
a significant amount of water to enter the
indoors.
Do not place obstacles around air-intake
vents or inside cool air outlet.
• It may cause failure of appliance.
Do not use strong detergent such as
wax or paint thinner to clean the unit.
Use a damp, so cloth.
• Appearance may deteriorate due to change
of product color or scratching of its surface.
CAUTION
ELECTRICAL SAFETY
Hold the plug by the head of the power
plug when unplugging unit.
• Pulling from the wire can cause wire to fray
leading to electric shock or fire.
If unit is equipped with an outdoor
installation bracket, periodically ensure that
it has not become damaged.
• If bracket is damaged, the unit can fall and
cause damage, personal injury or death.
Do not place heavy objects on the
power cord and ensure that the cord
is not pinched or stressed.
• There is danger of fire or electric shock.
Unplug the power cord when not using
the unit for extended periods of time.
• Will prevent damage to the unit.
Always insert the filters securely.
Clean filter at least once per month.
• Operation with dirty filters (or without
filters) will eect performance and may
cause damage to the unit.
Do not place this window-type air
conditioner through a wall.
• This will block the side vents and pre-
vent the unit from cooling properly.
• Be sure your electrical wiring is adequate for the model you have chosen. This information can be found on
the rating label, a silver-colored sticker generally located on the right side of the cabinet.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is
important. The power cord is equipped with a three-prong
grounding plug for protection against shock hazards.
• Your air conditioner must be connected to a properly grounded wall receptacle. If the wall receptacle you intend to use
is not adequately grounded or protected by a time delay
NOTE:The power supply cord with this air conditioner
contains a current detection device designed to reduce the risk
of fire. In the event that the power supply cord is damaged, it
cannot be repaired -- it must be replaced with a cord from the
Product Manufacturer.
fuse or circuit breaker, have a qualified electrician install the proper
receptacle.
• Ensure the receptacle is accessible aer the unit installation.
ENGLISH
The power supply cord contains a current device that senses damage
to the power cord and excess current draw from the unit. To test your
current device do the following:
1. Plug in the Air Conditioner.
2. Press the TEST button. You will hear a click as the RESET button
pops out within the rubber housing and the LED will turn o.
3. Press the RESET button. You will hear a click as the button
engages and the LED will illuminate.
4. The power supply cord is now supplying electricity to the unit.
Note: Your model may have the TEST and RESET buttons on the
side or the front of the plug head.
NOTES:
• Do not use the TEST and RESET buttons to turn the unit on or o.
• If the current device fails the test or the power cord becomes dam-
aged, the entire power cord must be replaced with an equivalent
power cord and current device by a licensed electrician.
–5–
Side button
version
ENGLISH
INTRODUCTION
Thank you for purchasing this quality Impecca window air conditioner unit. To ensure
the longest life and highest energy eiciency of your unit, please carefully follow these
operating instructions. Keep these instructions in a safe place and consult them as
needed. Please note that constant enhancement and improvements to our air conditioning units may mean that your model will slightly dier in appearance from the model pictured in this manual, but the actual operation and installation of the unit remains
unchanged. This manual is solely provided for informational purposes and does not
constitute a binding, legal contract.
SAFETY NOTICE:
This appliance should not be used by children or mentally/physically disabled persons without strict, direct supervision by a responsible adult. Never play with or around the appliance.
SAFETY INFORMATION
• Before operation, ensure your electrical installation (outlets and circuits) complies
with the power specifications found on the unit.
• Before cleaning or maintaining the air conditioner, please turn o air conditioner and
unplug the unit.
• Make sure the power cord isn’t kinked, bent, or under the weight of sharp or heavy
objects.
• Do not pull or yank the power cord to unplug the unit or move the air conditioner.
• Do not insert or unplug the power plug with wet hands.
• Only use a grounded power outlet. Make sure the grounding is functional.
• If the power cord is damaged, it must be replaced by the manufacturer or a qualified
technician in order to avoid fire and electrical hazards.
• Should abnormal operation occur (such as a burning smell), please disconnect power cord immediately and contact your local dealer.
• If nobody is present to monitor the operation of the unit, please turn it o and disconnect the power cord.
• Do not splash or pour water on air conditioner to avoid causing a short circuit or
damage to the unit.
• Do not put or hang dripping objects above the air conditioner.
• Ensure the ambient temperature remains well above freezing (32°F or 0°C) to avoid
cracking or damaging the unit.
• Keep heat sources away from the air conditioner.
• Ensure the unit is far away from fire, inflammable, or explosive objects.
• Never allow children or persons with reduced physical, sensory, or mental capabilities to operate or play around the air conditioner without direct adult supervision.
• Never allow children to perform cleaning or other user-maintenance operations
without direct adult supervision.
• Never attempt to repair or disassemble the air conditioner by yourself.
• Never insert objects into the air conditioner.
–6–
OPERATING CONDITIONS
F
G
H
I
E
DCB
• The air conditioner must be operated within the temperature range of 62°F to 95°F
(16°C to 35°C).
• A perimeter of 12′′(30cm) around the air conditioner should be free of all objects.
• Keep air inlet and air outlet clean and free of obstructing objects.
• During operation, close doors and windows to improve cooling eect.
• Please put the air conditioner at smooth and flat ground for operation to avoid noise
and vibration.
• Do not tilt or turn over the air conditioner. If there’s problem, please disconnect the
power supply immediately and contact your local dealer or technical support.
GETTING TO KNOW YOUR AIR CONDITIONER
1. Upper rail
2. Cool air outlet
3. Cool air directional levers
4. Fresh air vent
control (some
models)
5. Filter cover grasps
6. Control Panel
7. Outside air intake
(Do not block
these vents!)
8. Warm air intake
ENGLISH
USING YOUR AIR CONDITIONER
FRESH AIR VENT (SOME MODELS)
When cooling, always leave the vent closed (Fig A).
When operating the unit in fan only mode, you may also open the vent (Fig B.) Another
option is opening the vent and exhaust at the same time(Fig C), which is good for removing odors from the room during fan mode.
Fig B.Fig C.
–7–
Fig A.
ENGLISH
Ion
OVERVIEW OF CONTROLS FUNCTIONS
Before you begin, thoroughly familiarize yourself with the control panels as shown below
and all its functions, then follow the symbol for the functions you desire. The unit can be
controlled by the unit control panel located on the front of the device or with the remote
controller.
1. Temperature/Timer Down
2. Timer (Delay start/stop)
3. Check Filter light reset
B
H
4. Clean Air/Ionization (On Some models)
C
D
E
F
G
Ion
PMTS
Control Panel
5. Function selector (Auto-Cool-Dry-Fan)
I
6. Energy Saver
J
7. Temperature/Timer Up
8. Display (Temperature/Timer)
9. Sleep mode
K
10. Fan Speed selector
L
11. Infrared Remote senor window
M
12. On/O
N
13. PMTS (On Some Models)
Note that your model's control panel may dier
slightly.
POWER ON/OFF
Press the On/O button to turn the unit on or o.
CLEAN AIR (ION) FEATURE (ON SOME
MODELS)
Available on certain models, the ion generator
creates an energized field and will help to remove pollen and impurities from the air, trapping them in the filter.
–8–
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.