IMP8
IMP81111
, IMP8
, IMP81122
©
1999 IMP, Inc. 408-432-9100/www.impweb.com 3
Parameter Symbol Conditions Min Typ Max Units
Input Voltage (VCC) Range V
CC
TA= 0°C to 70°C 1.1 5.5 V
TA= –40°C to 105°C 1.2 5.5
Supply Current (Unloaded) I
CC
TA= –40°C to 85°C V
CC
< 5.5V, L/M/J 6 15 µA
T
A
= –40°C to 85°C V
CC
< 3.6V, R/S/T 5 10
T
A
= 85°C to 105°C V
CC
< 5.5V, L/M/J 25
TA= 85°C to 105°C V
CC
< 3.6V, R/S/T 20
Reset Threshold V
TH
L devices
T
A
= 25°C 4.56 4.63 4.70 V
T
A
= –40°C to 85°C 4.50 4.75
T
A
= 85°C to 105°C 4.40 4.86
M devices
T
A
= 25°C 4.31 4.38 4.45
T
A
= –40°C to 85°C 4.25 4.50
T
A
= 85°C to 105°C 4.16 4.56
J devices
T
A
= 25°C 3.93 4.00 4.06
T
A
= –40°C to 85°C 3.89 4.10
T
A
= 85°C to 105°C 3.80 4.20
T devices
T
A
= 25°C 3.04 3.08 3.11
T
A
= –40°C to 85°C 3.00 3.15
T
A
= 85°C to 105°C 2.92 3.23
S devices
T
A
= 25°C 2.89 2.93 2.96
T
A
= –40°C to 85°C 2.85 3.00
T
A
= 85°C to 105°C 2.78 3.08
R devices
T
A
= 25°C 2.59 2.63 2.66
T
A
= –40°C to 85°C 2.55 2.70
T
A
= 85°C to 105°C 2.50 2.76
Reset Threshold Temp. Coefficient TC
VTH
30 ppm/°C
VCCto Reset Delay VCC= VTHto (VTH- 125mV), L/M/J devices 40 µs
VCC= VTHto (VTH- 125mV), R/S/T devices 20
Reset Active Timeout Period TA= 0°C to 70°C 140 560 ms
TA= –40°C to 105°C 100 840
MR Minimum Pulse Width t
MR
10 µs
MR Glitch Immunity Note 3 100 ns
MR to RESET Propagation Delay t
MD
Note 2 0.5 µs
MR Input Threshold V
IH
VCC> V
TH (MAX)
, IMP811/812L/M/J 2.3 V
V
IL
0.8
V
IH
VCC> V
TH (MAX)
, IMP811/812R/S/T 0.7V
CC
V
IL
0.25V
CC
MR Pull-up Resistance 10 20 30 kΩ
Low RESET Output Voltage (IMP811) V
OL
V
CC
= VTHmin., I
SINK
= 1.2mA, IMP811R/S/T 0.3 V
V
CC
= VTHmin., I
SINK
= 3.2mA, IMP811L/M/J 0.4
VCC> 1.1V, I
SINK
= 50µA 0.3
High RESET Output Voltage (IMP811) V
OH
VCC> VTHmax., I
SOURCE
= 500µA, IMP811R/S/T 0.8V
CC
V
VCC> VTHmax., I
SOURCE
= 800µA, IMP811L/M/J V
CC
-1.5
Low RESET Output Voltage (IMP812) V
OL
VCC= VTHmax., I
SINK
= 1.2mA, IMP812R/S/T 0.3 V
VCC= VTHmax., I
SINK
= 3.2mA, IMP812L/M/J 0.4
High RESET Output Voltage (IMP812) V
OH
1.8V < VCC< VTHmin., I
SOURCE
= 150µA 0.8V
CC
V
Electrical Characteristics
Unless otherwise noted VCCis over the full voltage range, TA= –40°C to 105°C.
Typical values at T
A
= 25°C, VCC= 5V for L/M/J devices, VCC= 3.3V for T/S devices and VCC= 3V for R devices.
Notes: 1. Production testing done at TA= 25°C. Over temperature specifications guaranteed by design only using six sigma design limits.
2. RESET output is active LOW for the IMP811 and RESET output is active HIGH for the IMP812.
3. Glitches of 100ns or less typically will not generate a reset pulse.