1999 IMP, Inc. 408-432-9100/www.impweb.com 3
IMP1
IMP1
832
832
Absolute Maximum Ratings
Electrical Characteristics
Voltage on VCC . . . . . . . . . . . . . . . . . . . . . . . . –0.5V to 7V
Voltage on ST, TD . . . . . . . . . . . . . . . . . . . . . – 0.5V to V
CC
+ 0.5V
Voltage on PBRST, RESET, RESET . . . . . . . . – 0.5V to V
CC
+ 0.5V
Operating Temperature Range . . . . . . . . . . . –40°C to 85°C
Soldering Temperature . . . . . . . . . . . . . . . . . . 260°C for 10 seconds
Storage Temperature . . . . . . . . . . . . . . . . . . . –55°C to 125°C
Voltages measured with respect to ground.
These are stress ratings only and functional operation is not implied.
Parameter Symbol Conditions Min Typ Max Units
Supply Voltage (VCC)V
CC
1.0 5.5 V
ST and PBRST Input High Level V
IH
VCC≥ 2.7V 2 VCC+ 0.3V V
ST and PBRST Input High Level V
IH
VCC< 2.7V VCC- 0.4V V
ST and PBRST Input Low Level V
IL
–0.3 0.5 V
VCCTrip Point (TOL = GND) V
CCTP
2.80 2.88 2.97 V
VCCTrip Point (TOL = VCC)V
CCTP
2.47 2.55 2.64 V
Watchdog Time-Out Period t
TD
TD = GND 62.5 150 250 ms
Watchdog Time-Out Period t
TD
TD = V
CC
500 1200 2000 ms
Watchdog Time-Out Period t
TD
TD floating 250 610 1000 ms
Output Voltage V
OH
I = –500µA, VCC< 2.7V VCC- 0.3V VCC- 0.1V V
Output Current I
OH
Output = 2.4V, VCC≥ 2.7V 350 µA
Output Current I
OL
Output = 0.4V, VCC≥ 2.7V 10 mA
Input Leakage I
IL
–1.0 1.0 µA
RESET Low Level V
OL
0.4 V
Internal Pull-Up Resistor PBRST pin 40 kΩ
Operating Current I
CC1
Outputs open. VCC≤ 3.6V 20 µA
and all inputs at VCCor GND
Input Capacitance C
IN
5pF
Output Capacitance C
OUT
7pF
PBRST Manual Reset t
PB
PBRST = V
IL
20 ms
Minimum Low Time
Reset Active Time t
RST
250 610 1000 ms
ST Pulse Width t
ST
Must not exceed tRDminimum. 20 ns
Watchdog cannot be disabled.
VCCFail Detect to t
RPD
Pulses < 2µs at V
CCTP
58µs
RESET or RESET minimum will not cause reset.
VCCSlew Rate t
F
20 µs
PBRST Stable LOW to t
PDLY
20 ms
RESET and RESET Active
VCCDetect to RESET or t
RPU
t
rise
= 5µs 250 610 1000 ms
RESET Inactive
VCCSlew Rate t
R
0ns
Unless otherwise stated, 1.2V ≤ VCC≤ 5.5V and over the operating temperature range of –40°C to +85°C . All voltages are referenced