i-mop I-GUM GAS VERSION Quick Guide

Page 1
B
G
H
A
A
Solution tank
B
Recovery tank
C
Battery pack
D
Brushes
E
E
Squeegee
F
Control panel
G
Vacuum filter/float
H
Deflector
C
D
F
Brush
Turbine
Water
Eco
Operation
Install battery pack:
Slide in the battery pack.
PH
Fill solution tank.
Max temperature 45oC
/ 113
o
F. Ensure pH is
between 4 and 9.
Install
recovery tank
by attaching to
magnetic clip.
Make sure top
lid is clicked
and closed.
Attach solution
tank to
magnetic clip.
Release magnetic connector
for scrub-deck and slowly
lower deck by hand.
Maintenance and Care daily weekly monthly
Remove and clean the filter/float by rinsing it with water.
Detach and clean the brushes and also the bottom of the
brush-deck, now that it is fully exposed.
Drain and rinse the solution and recovery tanks with fresh water and leave them open.
Remove the deflector gently from the machine and clean it.
Clean the squeegee blade and suction opening with fresh water and a clean cloth.
Select operation mode and
you’re ready to go!
7
To remove the battery pack:
Pull back blue release clip away from
battery pack. Battery will be ejected.
Check the charge level on the battery indicator.
Recharge the battery as required.
Check the rubbers on the squeegee blade for damage or wear and tear.
Turn them over or replace them entirely when needed.
Clean the wheels on the squeegee blade, make sure the bearings aren’t clogged.
Unscrew the filter from the solution tank and clean it under running water.
Clean the exterior of the imop with a clean cloth and fresh water.
Remove the brushes from the machine and clean the water nozzles
at the bottom of the scrub deck.
If the imop isn’t being used regularly, remove and store the charged
battery in a dry and clean place. Recharge battery at least monthly.
Clean the filter/float regularly.
Do not kick the deck with foot. Gently lower by hand only.
Empty the tank before storing it and empty the tank before refilling it.
ALWAYS switch machine off when not in use or when in storage.
Leave the rubber cap open when storing overnight so the tank can vent.
Do not operate without filter/float.
Close the cap of the recovery tank, otherwise there’s no water pick-up.
PH
Do not use water with pH below 4 or above 9, and temperature higher than
o
45
C / 113 oF.
Troubleshooting
The imop won’t start
Check the charge level on the battery indicater. Remove the battery pack from the machine. Inspect the connectors on the battery and on the machine for any damage or obstruction. Reinsert the battery and switch on the machine. Make sure that the battery is charged, recharge when needed or grab a freshly charged battery. If the problem still exists we recommend to reset the imop according to our reset procedure.
Reduced Water Recovery
Please ensure that you have chosen the right cleaning mode and the vacuum motor is running. Check the recovery tank, when full empty it. Always empty the recovery tank after cleaning or when you’ve used up all the solution in the solution tank. Inspect both the deflector and the air filter, clean when needed. Make sure that the recovery tank is seated correctly on the machine, and the cap is back on the top of the tank and is closed properly. Check if hose is connected in the deflector block. Inspect the rubbers on the squeegee for any damage or wear and tear and that there is nothing stuck inside the squeegee
blade blocking the airflow. Make sure the wheels are clean and that they can turn freely. Detach the vacuum hose from the machine and check both the hose and the opening on the machine.
Insufficient water flow or no water flow
Check if the solution tank is filled and seated correctly on the machine. Check if the hole in the cap is not obstructed by any dirt. Open and close the rubber cap to avoid vacuum in the tank. Make sure that the right operating mode is selected. Remove the brushes and check the water nozzles on the scrub deck for any obstructions. Empty the solution tank and check the filter, make sure that it is clean. If the filter is dirty, please check that it is cleaned monthly or more often, if required by your circumstances.
Reset
To reset the imop Lite simply remove the battery pack and put it back in again.
Loading...