JAGUAR VX Torque Vector System
Sensorless Vector Variable Frequency Inverters
- 0.4kW to 280kW
High performance, Torque Vector Control
Up to 250% torque at 1Hz
Low torque ripple at low speed
Fast torque response - 200mS, 0 - 100% load
Load speed regulation < 1% open loop
Ultra compact IP20 enclose (22kW)
Dual LED/LCD plain English display
User programmable I/O
Low motor noise profile
Auto energy saving function
Renowned IMO 5 year warranty
Specifications
JAGUAR VX ORDER CODES VX40 VX75 VX150 VX220 VX400 VX550 VX750 VX1100 VX1500 VX1850 VX2200
JAGUAR VXP ORDER CODES - - - - - - VX750P VX1100P VX1500P VX1850P VX2200P
MOTOR RATING (kW) 0.4 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22
RATED O/P CURRENT (A) 1.5 2.5 3.7 5.5 9 13 18 24 30 39 45
100% RATED I/P CURRENT RMS 1.7 2.9 5.5 7.7 12.6 18.2 24.4 36.3 48.5 59 72
(AT 400V)*
HEAT LOSS (W) 45 50 65 85 110 140 200 315 340 450 510
(AT 2 KHz CARRIER FREQUENCY)
INPUT VOLTAGE/FREQUENCY 3 PHASE 380 TO 415V (+10%,-15%) 50/60 Hz (+5%,-5%)
WEIGHT (Kg) 2.4 3.2 3.2 3.2 3.2 6.5 5.3/6.5 10.6/6.5 10.6/11.5 10.6/11.5 10.6/12
INPUT POWER FACTOR** 0.96 0.95 0.94 0.93 0.94 0.95 0.95 0.95 0.94 0.95 0.96
OUTPUT VOLTAGE FREQUENCY 3 PHASE 0 - V INPUT 0.2 - 400 Hz (‘P’ MODELS 0.2 - 120 Hz)
JAGUAR VX ORDER CODES VX30K VX37K VX45K VX55K VX75K VX90K VX110K VX132K VX160K VX200K VX220K
JAGUAR VXP ORDER CODES VX30KP VX37KP VX45KP VX55KP VX75KP VX90KP VX110KP VX132KP VX160KP VX200KP VX220KP VX280KP
MOTOR RATING (kW) 30 37 45 55 75 90 110 132 160 200 220 280
RATED O/P CURRENT (A) 60 75 91 112 150 176 210 253 304 377 415 520
100% RATED I/P CURRENT RMS 58 71 85 104 141 168 203 243 293 363 400 508
(AT 400V)*
HEAT LOSS (W) 1200 1400 1600 1900 2300 2700 3000 3400 4000 4600 5000 6000
(AT 2 KHz CARRIER FREQUENCY)
INPUT VOLTAGE/FREQUENCY 3 PHASE 380 TO 415V (+10%,-15%) 50/60 Hz (+5%,-5%)
WEIGHT (Kg) 36 36/37 37/44 45/54 54/61 61/88 88 88/120 120/125 125/177 177 177
INPUT POWER FACTOR** 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 0.95 OUTPUT VOLTAGE FREQUENCY 3 PHASE 0 - V INPUT 0.2 - 400 Hz (‘P’ MODELS 0.2 - 120 Hz)
NOTES * FIGURES FOR INPUT ARE QUOTED WHEN USING ADC REACTOR FROM VX30K AND VX30KPUP, NO REACTOR < 30KW
** AT 100% FULL LOAD CURRENTAND USING DC REACTOR
Basic circuit configuration and terminals
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Jaguar VX
WARNING! INVERTER MUST BE EARTHED
Terminal Markings for DC
Terminal Markings for DC
*
bus reactor and Braking
bus reactor and Braking
Resistor or Braking Unit
Resistor for Braking Unit
The marking of these
The marking of these
terminals varies between
terminals varies between
different sizes of Jaguar VX
different sizes of Jaguar VX
inverter. Please refer to
inverter. Please refer to
pages 19, 20 and 21 for
manual for specific details.
specific detail.
Input
contactor
3-phase
power supply
50Hz or
60Hz
Analog voltage
frequency ref.
input
(Pot. 1k, 1W)
4-20mA
analog input
Programmable analog output
Digital output
RTS
12
Control
inputs
(FWD)
(Optional 22kW)
Link P1 to (*)
if DC reactor
not required
L1 L2 L3
+10V DC
(13) (12) (11)
250
(C1)
+ve
(FMA)
(FMP)
(CM)
(V1)
Note (3)
4.7k
(REV)
4.7k
(THR)BU
4.7k
(HLD)
4.7k
(X1)
4.7k
(X2)
4.7k
(X3)
4.7k
(X4)
4.7k
(X5)
4.7k
(BX)
4.7k
(RST)
4.7k
(P24) or (CMS)
Note (6)
Braking resistor (option)
for all inverters.
DC Bus reactor
GND
(PE)
P1
Note (1)
A/D
SMPS
+24V DC
Z
0V
0 to 10V DC
Pulse output
0V
Input
signal
0V
+24V DC
P(+) DB
GND
(PE)
P(+)
*
R
DC voltage
detection
Keys
Frequency
command
regulator
Function
generator
N(-)
*
*
Power
charge
LED
‘CRG’
Keypad Panel
CPU
switch
Accel /
Decel
CPU
RTS
RTS = Volt-free NC contact
for thermal protection.
2
Braking unit (option).
0V
BU
On-board braking IGBT and resistor applicable only to VX40 to VX750 and VX750P to VX1100P. Disconnect the internal resistor (R) before connecting an external resistor.
Applicable to VX1100, VX1500P, VX30K
1
24V
and inverters larger than these.
U V
W
GND
Gate drive
Current
detection
Voltage
detection
(PE)
RF filter (if fitted)
Note (2)
Connect via
Earth busbar
at MCC
LED, LCD
displays
PWM
generator
Auto-
voltage
regulator
Torque
vector
calculator
Protective
logic
A/D
(AX1) (AX2)
(30C) (30B) (30A)
Run
relay
output
Trip
relay
output
Note (3)
(Y1E) (Y2E)
Output
signal
(Y3E) (Y4E)
Programmable
outputs
(Y5E)
(CMC)
(P24) or (CMS)
(CM)
0V
Note (4)
M
Note (6)
NOTES
(1)
For inverters rated 22kW the inrush contactor is replaced by an SCR.
(2)
Voltage detection circuit applicable for inverters 30kW only.
(3)
Standard for inverters 30kW, optional for smaller models.
(4)
Two terminals (CM) standard for inverters 22kW, one for 30kW.
(5)
If motor thermistors are required, please consult IMO.
(6)
Internal +24V DC supply terminal designated P24 (22kW) or CMS (30kW).
0V Common Terminals (11) and (CM) are optically isolated. Relay status shown as at inverter ‘power ON’ or ‘healthy’.
Jaguar VX
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Control circuit connections
Purpose
Analog
frequency
setting
Programmable
inputs
Meter
outputs
Programmable
outputs
Relay
outputs
Terminal
11 12
13
C1
V1*
CM†
FWD
REV
HLD
BX
THR
RST
X1 X2 X3
X4
X5
P24 P24
FMA
FMP
CMC
Y1E Y2E Y3E Y4E Y5E
30A 30B 30C
AX1* AX2*
* Standard for 30kW only, optional for 22kW. † Two CM terminals for 22kW, one for ≥30kW.
Speed reference 0V common Potentiometer input
Potentiometer supply
Current loop input
Auxiliary freq. reference 0V common Forward and STOP command
Reverse and STOP command
FWD/REV command hold
Coast-to-stop command
External Trip/Alarm input
Trip/Alarm RESET
Programmable input 1 Programmable input 2 Programmable input 3
Programmable input 4
Programmable input 5
+24V DC power supply
Analog meter
Pulse frequency meter
Open-collector common Programmable output 1 Programmable output 2 Programmable output 3 Programmable output 4 Programmable output 5
Normally open Normally closed Common
Run relay
Terminal Name
Description
For use with terminals 12, 13 and C1 (and V1, ≥30kW only) Maximum speed demand is at +10V with a 0V to +10V DC
input. Input impedance 20kΩ (22kW), 22kΩ (30kW). Regulated +10V DC power supply for 1kmin. speed control
potentiometer. Input 10mA max. Maximum speed demand is at 20mA with a 4-20mA DC
input, impedance 250. Inverter output frequency is proportional to current input signal, zero speed = 4mA.
Bipolar 0V to ±10V input. 0V common terminals for general use. FWD-P24 closed: Motor runs forward
open: Motor decelerates to rest
REV-P24 closed: Motor runs in reverse
open: Motor decelerates to rest
HLD-P24 closed: Latches momentary FWD or REV inputs
open: FWD/REV non-latching
BX-P24 closed: Inhibit inverter output instantaneously
open: Normal
THR-P24 closed: Normal
open: Trip (OH2) inverter output instantaneously
If RST-P24 closed for 100ms, inverter internal fault trips are reset, and also alarm 30A/B/C (see below).
Preset speeds or motorised potentiometer
Preset speeds or mains-to-inverter changeover Preset acc/dec command. LOC/REM changeover.
DC injection brake command. Preset acc/dec times. 2nd motor V/F ratio. Data protection
enable/disable. 24V current source for programmable I/O terminals and for
FWD, REV, HLD, BX, THR, RST and X1 to X5. Output frequency, current, torque or load factor can be
selected. 0V to +10V DC at 2mA max. Pulse output proportional to inverter output frequency. Pulse
frequency 6 to 100 x O/P Hz at +10V DC (adjustable). 0V
Up to 16 different outputs can be programmed from the operating Functions representative of dynamic operating conditions. Factory defaults: Y1E Inverter running Y2E FAR Y4E Overload early warning Y3E FDT Y5E Undervoltage
Relay changes state when an internal protection function is active and when the inverter trips. Contact: 250V AC, capacity 0.5A, cosφ 0.3
Relay closes when inverter is running Contact: 250V AC, capacity 0.5A, cosφ 0.3
If FWD and REV are both closed or both open, inverter output STOPS.
(Min. impedance 5kΩ)
Output:
27V DC,
50mA per
O/P channel,
total 50mA
maximum.
Caution
Read Technical
Manual before
use.
Parameter list/function code table
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Group No. Name LCD Display Setting range Unit Resol. Def.
Basic Functions
00
Frequency command
01
Operating mode
02
Max. O/P frequency
03
Base freq., motor 1
04
Max. O/P V, motor 1
05
Accel. time, motor 1
06
Decel. time, motor 1
07
Torque boost, motor 1
08
Electronic thermal O/L, type
09
Electronic O/L, level
10
Restart after momentary power supply failure
11
O/P freq. HI limit
12
O/P freq. LO limit
13
Min. O/P freq. (bias)
14
Freq. I/P ref. gain
15
Driving torque limit
16
Braking torque limit
17
DC inj. brk. Start frequ.
18
DC inj. brk. Brkg. level
19
DC inj. brk. Brkg. time
20
Pre-set multistep
to
frequencies 1 to 7
26 27
Intl. electronic thermal O/L for intl. brkg. R
28
Slip compensation
29
Torque vector control
30
Number of motor poles
00 FREQ COMND
01 OPR METHOD
02 MAX Hz 03 BASE Hz -1 04 RATED V -1
05 ACC TIME 1 06 DEC TIME 1 07 TRQ BOOST 1
08 ELECTRN OL
09 OL LEVEL 10 RESTART
11 H LIMITER 12 L LIMITER 13 FREQ BIAS 14 FREQ GAIN 15 DRV TORQUE
16 BRK TORQUE
17 DC BRK Hz 18 DC BRK LVL 19 DC BRK t 20 MULTI Hz -1
to
26 MULTI Hz -7 27 DBR OL
28 SLIP COMP 29 TRQ VECTOR 30 MTR POLES
0 = KEYPAD, ∧ or ∨ keys 1 = TERMINAL, 0 to +10V 2 = TERMINAL, 4 to 20mA
0 = KEYPAD, RUN/STOP keys 1 = TERMINAL, (FWD) & (REV)
VX, 50-400Hz VX…P, 50-120Hz VX, 50-400Hz VX…P, 50-120Hz
0 = Output dependent on supply V* 320 to 480 = output V
0.01 to 3600
0.00 = ramp inhibit, or 0.01 to 3600
0.0 = auto; 0.1 to 20.0 fixed boost
0 = Inactive 1 = Active for standard motor 2 = Active for inverter-rated motor
20% to 105% of inverter rating 0 = Inactive 1
1 = Inactive 2 2 = Active, smooth recovery 3 = Active, restart at set Hz 4 = Active, restart at start Hz
VX, 0-400Hz VX…P, 0-120Hz VX, 0-400Hz VX…P, 0-120Hz VX, 0-400Hz VX…P, 0-120Hz
0.0 to 200.0% 20 to 180, 999% (999 = no limit)
0, 20 to 180, 999% (999 = no limit)
0.0 to 60.0Hz
0.0 to 100%
0.0 (brake inactive), or 0.1 to 30.0s
VX 0.00, 0.20 to 400.0Hz VX…P 0.00, 0.20 to 120.0Hz
(0.00 = preset disabled)
0 = Inactive 1 = Active for intl. R, invrs. 7.5kW 2 = Inactive
-9.9Hz to +5.0Hz 0 = Inactive 1 = Active 2 to 14 (even nos. only)
Hz Hz
V
s s
A
Hz Hz Hz
% %
%
Hz
%
s
Hz
Hz
Jaguar VX
0.01
0.01
0.1
0.01 —
0.1
0.1
0.1
0.1
0.01
0.1 —
0
0
1
50
1
50
1
400
6.00
6.00
0.0
[0.1]
1
† 3
1
70
1
0
1
0
100.0
1
150
[120]
1
100
[100]
0.0
0.0
0.0
0.00
1 [0]
0.0 0
2
4
Functions marked by heavy outlines can be set whilst the inverter is running. DEF = factory-set defaults. Resol = resolution. Default values are for all inverters. Where VX…P defaults differ, they are shown in square brackets […]. * LCD display shows 0V † Approx. rated current for inverter-rated motors
Jaguar VX
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Parameter list/function code table (continued)
Group No. Name LCD Display Setting range Unit Resol. Def.
31
31
Prog. I/P terminals
Acc./Dec. times
2nd motor
42
Digital O/P
Analog O/P
O/P term. functions
52
Frequency control
Function Block 32 to 41
32
Select the functions of terminals X1 to X5
33
Accel time 2
34
Decel time 2
35
Accel time 3
36
Decel time 3
37
Accel time 4
38
Decel time 4
39
Base freq., motor 2
40
Max. O/P V, motor 2
41
Torque boost, motor 2
42
Function Block 43 to 51
43
FMP terminal, pulse rate multiplier
44
Voltage O/P adjustmt.
45
FMA terminal, voltage adjustment
46
FMA terminal function
47
Select the functions of terminals Y1E to Y5E
48
FAR function (‘At Speed’ window)
49
FDT function (level)
50
FDT function (hyster.)
51
O/L alarm (level)
52
Function Block 53 to 59
53
Skip frequency 1
54
Skip frequency 2
55
Skip frequency 3
56
Skip hysteresis
57
Starting frequency
58
Holding time
59
Frequency I/P reference filter
31 32—41
32 X1-X5 FUNC
3X ACC TIME X
39 BASE Hz -2 40 RATED V -2
41 TRQ BOOST 2 42 43—51
43 FMP PULSES
44 FMP V-ADJ 45 FMA V-ADJ
46 FMA FUNC
47 Y1-Y5 FUNC
48 FAR HYSTR
49 FDT LEVEL 50 FDT HYSTR 51 OL WARNING
52 53—59
53 JUMP Hz 1 54 JUMP Hz 2 55 JUMP Hz 3 56 JUMP HYSTR 57 START Hz 58 HOLDING t 59 FILTER
0 = Functions 32 to 41 hidden 1 = Functions 32 to 41 displayed
0000 to 2222
0.00 = Ramp inhibited, coasting
0.01 to 3600s
VX, 50-400Hz VX…P, 50-120Hz 0 = Output dependent on supply V*
320 to 480 = output V
0.1 to 20.0 fixed boost 0 = Functions 43 to 51 hidden
1 = Functions 43 to 51 displayed x6 to x100
50% to 120% 65% to 200%
0 = O/P freq. 1 = O/P current 2 = O/P torque 3 = %FLT
00000 to FFFFF
0.0 to 10.0Hz
VX, 0-400Hz VX…P, 0-120Hz
0.0 to 30.0Hz Approx. 20 to 105% inverter rated
current 0 = Functions 53 to 59 hidden
1 = Functions 53 to 59 displayed
VX, 0-400Hz VX…P, 0-120Hz VX, 0-400Hz VX…P, 0-120Hz VX, 0-400Hz VX…P, 0-120Hz
0 to 30Hz
0.2Hz to 60.0Hz
0.0 to 10.0s
0.01 to 5.00s
Hz
V
— —
% %
Hz
Hz Hz
A
Hz Hz Hz Hz Hz
s
0.01
0.1 —
0.1
0.1
0.01
0.1
s
0.1
s
0.01
0
0000
10.00
10.00
15.00
15.00
3.00
3.00
1
50
1
400
2.0 0
1
x24
1
100%
1
100%
0
01234
2.5
1
50
1.0 †
0
1
0
1
0
1
0
1
3
0.5
0.0
0.05
Functions marked by heavy outlines can be set whilst the inverter is running. DEF = factory-set defaults. Resol = resolution. Default values are for all inverters. Where VX…P defaults differ, they are shown in square brackets […]. * LCD display shows 0V † Approx. rated current for inverter-rated motors
Parameter list/function code table (continued)
Group No. Name LCD Display Setting range Unit Resol. Def.
60
60
LED & LCD displays
Pattern operations
Special Functions 1
80
Special Functions 2
Motor characteristics
Special Functions 3
Function Block 61 to 79
61
LEDs, function for normal display
62
LEDs display at STOP
63
Coefficient for machine speed and line speed
64
LCD display function
65
Pattern operation, mode select
66
Pattern stages 1 to 7
to
72 73
ACC/DEC mode
74
Series brake motor driving
75
Energy saving
76
REV phase sequ. lock
77
Data initialising (data reset)
78
Language of displays
79
LCD display brightness
80
Function Block 81 to 94
81
PWM carrier frequency (motor sound)
82
Auto-restart, start delay
83
Auto-restart, freq. fall rate
84
Auto-reset, number of restarts
85
Auto-reset, interval
86
Motor 1, frame size
87
Motor 1, rated current
88
Motor 1, no-load current
89
Motor 2, rated current
90
Motor 1, tuning
91
Motor 1, %R1 value
92
Motor 1, %X value
93
Manufacturer’s use only
94
Data security
95
60 61—79
61 LED MNTR 1
62 LED MNTR 2
63 SPEED COEF
64 LCD MNTR
65 PATTERN
6X STAGE X
73 ACC PTN 74 SERIES BRK
75 ENERGY SAV 76 REV LOCK 77 DATA INIT
78 LANGUAGE 79 BRIGHTNESS
80 81—94
81 MTR SOUND
82 RESTART 1 83 FALL RATE
84 AUTO RESET
85 RESET INT 86 MOTOR CAP
87 MOTOR 1-Ir 88 MOTOR 1-Io 89 MOTOR 2-Ir 90 TUNING 91 %R1 SET 92 %X SET 93 DD FUNC 1 94 DD FUNC 2 95 DATA PRTC
0 = Functions 61 to 79 hidden 1 = Functions 61 to 79 displayed
0 to 8
0 = Set point (flashing) 1 = Actual output value only
0.01 to 200.00 x Hz output
0 to 3: Drive status, standard screen or bar graphs
0 to 3: Inactive or cyclic
Operation time 0.00 to 6000s FWD/REV codes F1 to F4 ACC/DEC codes R1 to R4
0 to 2: linear, S-curve, non-linear
Not available
0 = Inactive 1 = Active 0 = Inactive 1 = Active 0 = Inactive 1 = Active
0 to 3 0 (bright) to 10 (dark)
0 = Functions 81 to 94 hidden 1 = Functions 81 to 94 displayed
0 (low) to 10 (high) carrier frequency
0.0 to 5.0s
0.00 to 100.00
0 to 7
2 to 20s 0 = 1 higher 1 = nominal
2 = 1 lower 3 = 2 lower
0.00 to 2000A
0.00 to 2000A
0.00 to 2000A 0 = Inactive 1 = Active
0.00 to 50.00%
0.00 to 50.00%
0 = Unlocked 1 = Data secure
0 = GERMAN, 1 = ENGLISH 2 = SPANISH, 3 = ITALIAN
s
— — —
— —
s
Hz/s
s
A A A
% %
Jaguar VX
0.01
0.01
— — —
— —
0.1
— —
0.1
0.1
0.1 —
0.01
0.01
0
0
0
0.01
0
0
0.00 F1
0
0 [1]
0 0
1 5
0
10
0.1
1
10
0
5 1
† † † 0 † †
0
Jaguar VX
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Dimensions (mm) 0.4 to 280kW
Jaguar VX40
110 96
KEYPAD OPERATION
%
PRG
FUNC
RESET STOP
DATA
Jaguar VX75 to VX400
150 136
KEYPAD OPERATION
Hz
r/min
%
A
m/min
V
PRG
RUN
FUNC
RESET STOP
DATA
130
7
Hz
r/min
A
m/min
V
RUN
260
37
6
PRG
RESET STOP
246
6
7
7
260
246
87
145
52
6
Jaguar VX1100 to VX2200 and VX1500P to VX2200P
KEYPAD OPERATION
PRG
RESET STOP
KEYPAD OPERATION
FUNC DATA
FUNC DATA
220 196
Hz
r/min
%
A
m/min
V
RUN
12
260
238
10
10
250 226
Hz
r/min
%
A
m/min
V
RUN
12
400
378
195
97
10
162
195
96
10
Jaguar VX550, VX750, and VX750P, VX1100P
*N.B. JAGUAR VX inverters are designed
for use within shielded steel enclosures
Jaguar VX30K to VX220K, VX30KP to VX280KP
W1
CHARGE
KEYPAD OPERATION
Hz
r/min
%
A
m/min
V
PRG
RUN
FUNC
RESET STOP
DATA
6
W
2 holes
dmm diam.
7
H1
H2
d
102
10
10
78 68
KEYPAD OPERATION
REMOTE MOUNTING
KEYPAD WITH OPTIONAL
2M CONNECTOR CABLE
D
D1
Side vents on
inverters from
VX30K to VX75K
H
and VX30KP to
VX90KP only
VX W W1 H H1 H2 D D1 d
30K-D
30KP-D 37KP-D
37K-D 45KP-D 45K-D 55KP-D 55K-D 75KP-D 75K-D 90KP-D
90K-D 110KP-D 110K-D 132KP-D 132K-D 160KP-D 160K-D 200KP-D 200K-D 220KP-D
220K-D 280KP-D
340 240 550 530 500 290 185 10
340 240 550 530 500 290 185 10
375 275 550 530 500 290 185 10
375 275 675 655 625 275 170 10
530 430 675 645 610 290 185 15
530 430 740 710 675 300 180 15
530 430 740 710 675 330 205 15
530 430 740 710 675 330 205 15
530 430 1000 970 935 435 295 15
530 430 1000 970 935 435 295 15
680 580 1000 980 N/A 435 320 N/A
680 580 1000 980 N/A 435 320 N/A
STOP
PRG
FUNC
RESET STOP
DATA
Keypad panel
mounting dimensions.
Common to all modules.
162
Hz
r/min
%
A
m/min
V
125
115
RUN
Jaguar VX
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING
Optional accessories
Accessory Function
Filters A specially designed range of easily fitted low profile ‘footprint’ filters up to
22kW and stand alone filters up to 280kW are available to provide maximum RF reduction. See page 363 for details.
Function Copy Unit Saves and loads stored set-ups for up to 12 complete function sets. ‘Copy
Edit’, ‘verify’ and ‘write-protected’ modes available. Operates from an 85V to 265V AC supply. Target or donor drives do not need to be powered up to transfer data.
Encoder Feedback Module Enables Jaguar VX inverters to be operated in closed-loop control mode.
Speed control range 180 to 3600 rpm. Speed variation ±0.2% at 3600 rpm. Encoder output, 20 to 2000 pulses per revolution.
Relay Output Module Converts programmable outputs Y1E . . . Y5E to relay outputs.
Contact rating 0.3A at 250V AC, cosØ = 0.3.
PID Control Mode Unit Digitally adjustable P, I and D terms through the medium of a
supplementary function menu. Reference input 0V to 10V DC Feedback input 0V to 10V DC or 4-20mA DC.
Synchronisation Module Provides a multi-synch tasking capability via rotary encoders for
Master/Slave and ‘Follower’ applications.
Serial Communication Module RS422 or RS485, multi-drop up to 31 Jaguar VX inverters of all sizes. Opto-
isolated.
FieldBus Modules Dedicated FieldBus units which allow the connection of multiple
Jaguar VX inverters to a site standard FieldBus link. FieldBus systems available: Modbus Plus Interbus S Profibus DP DeviceNet
Regenerative Brake Units Provides additional braking for high inertia loads for inverters 11kW to
280kW. (Units below 11kW have regenerative braking capability built in as standard).
Pod Extension Cable Allows the Jaguar VX keypad to be removed and mounted separately.