immerSUN automatic power controller Installation & User Manual

1
ENGLISH
Installation & User Guide
V1.2
2
Contents
Introducing the immerSUN Main Screen Savings Boost (Manual) Boost (Timed) Menu View Readings Advanced Settings External Boost Input Multifunction Relay Installation System Overview immerLINK™ (linking units) immerSUN at a glance Electrical Connections Sensor Installation Setup Wiring Diagrams
Wiring: Single Heater
Wiring: Two Heater
Wiring: Three Heater
Wiring: Underfloor Heating (opt. 1)
Wiring: Underfloor Heating (opt. 2)
Wiring: Dual Tariff (Single Meter)
Wiring: Dual Tariff (Dual Meter)
Error Messages Technical Specification
3 4 5 6 7
8 10 12 13 14 16 18 19 20 22 23 24 25
26
28
30
32
34
36
38
40 42
3
Introducing the immerSUN
Thank you for choosing immerSUN - You have made an excellent choice!
The immerSUN is an automatic power controller for heaters. It tracks available surplus power from a grid-tied PV or Wind turbine system and varies the power to the heater to match the surplus power, therefore ensuring all of the green energy is fully utilised.
trusine™ Power Control Technology
The immerSUN uses TruSine™ power control technology. This means that the voltage is very smoothly adjusted to alter the power to the heater. The power going to the load is a non-distorted true sine wave, only the voltage is altered. This control technology is unique to the immerSUN and is more sophisticated than any similar product on the market. TruSine™ technology ensures trouble free operation with all inverters and compatibility with all import/export energy monitors.
Feature Set
Tracks surplus power and diverts this energy to the load
trusine™ technology for fast and smooth automatic power adjustment
Works with many microgeneration systems including PV, Wind and Hydro systems
Clear graphical backlit LCD display
Indicates current import/export power levels as well as diverted power to the heater
Savings are accurately reported for the day, month, year as well as the total since installation.
Savings can be displayed in several currencies as well as kWhs
No need to change immersion heater
Works with many types of heater including storage, panel and underfloor
One immerSUN can control up to 3 heaters sequentially
Only one current sensor for ease of installation with the option of a wireless sensor
Built-in 7-day programmable boost timer
Manual boost function for both heater outputs
Integral multi-function relay to provide additional functions such as: Economy-7 control, cylinder de-stratification pump control and export power threshold detect
Up to 5 immerSUN's can be linked together for larger systems
Smart, sturdy metal enclosure designed with the installer in-mind
Fully short circuit protected in case of load fault
Over load protection
Soft starting to avoid power surges
Smart meter compatible
Compatible with third-party energy monitors
Complete CE product approvals
Made in Britain with a 3-year product warranty
4
×
SAVINGS
MENU
Savings Today
Savings shown alternates between kWh and financial savings in the set currency.
Current Heater
The symbol for the heater being heated is shown along with the heater number.
Heater Power
The amount of power currently being sent to the heater.
Grid Power
The power either, being imported or exported. Import or export is shown by the direction of the arrow between the Grid and House symbols.
Date & Time
The current date, day of week and time.
Main Screen
The main screen shows the status of the immerSUN, the imported or exported power, the date and time and the savings made today. The house in the centre of the screen will be 'happy' if no power is being imported, otherwise a straight face will be displayed. Arrows either side of the house show the direction of power. From this screen the Menu can be accessed, a manual Boost can be triggered and there is a short-cut to the Savings data.
p8p5
BOOST
p6
5
Savings
×
SAVINGS
Savings that have been made by immerSUN are stored in permanent memory. The savings can be shown for Today, this Week, this Month and this Year as well as the Total since the immerSUN has been installed. The savings can be displayed as a list or in a graph. The savings are shown in kWh as well as financially in the chosen currency. For the financial savings to be correct, the user must keep the tariff up to date. The Set Tariff option in the Main Menu allows the user to set the current tariff, this should be set to reflect the kWh cost for the fossil fuel normally used to heat the heater.
6
Boost (Manual)
A heater can be 'boosted' to full power for a short period regardless of the amount of available export power, this function is called Manual Boost and is activated from the main screen. Once the boost starts, the remaining boost period will be displayed, this will start at 1 hour but can be adjusted during the boost. A manual boost can be cancelled at any time.
7
Boost (Timed)
Important points
Up to six different boost times can be entered.
Each week day can be individually selected for each boost time.
Only ONE heater can be boosted at any one time.
If any boost times overlap, the latest timed boost will take presidence.
For boost times crossing midnight, two time slots will need to be used.
The immerSUN can be programmed to 'boost' the heating for each heater at certain times. Boost means that the heater will be at full power regardless of the amount of available export power. This means that power may be drawn from the mains grid supply during boost times.
The Boost Times can be accessed from the Main Menu. Once in the BOOST TIMES screen, use the and buttons to select the boost time you wish to change, then press. You can now edit the boost times, use the and buttons to change the start time, end time, days of the week and heater number for the boost, (press the button to move to next section). Press the button to exit edit mode.
BOOST TIMES 06:30-07:30 MTWTFSS - 16:30-17:30 MTWTFSS - 07:30-08:30 MTWTFSS - 17:30-18:30 MTWTFSS - 08:30-09:30 MTWTFSS - 18:30-19:30 MTWTFSS -
BOOST TIMES 06:30-07:30 MTWTFSS ­16:30-17:30 MTWTFSS ­07:30-08:30 MTWTFSS ­17:30-18:30 MTWTFSS ­08:30-09:30 MTWTFSS ­18:30-19:30 MTWTFSS -
START
times
END
times
DAY of
week
HEATER
number or type
MAIN MENU
Boost Times
MAIN MENU
Boost Times
Special heater types
There two special heater types; T and B. These will only be available if the Multi Function Relay is set to Export Threshold or Boiler Boost and wired correctly.
T : Export Threshold boost, the appliance will be activated for the boost period. B : Boiler boost, the boiler will be activated for the boost period.
8
Holiday Mode
The immerSUN can be set to Holiday Mode, when you are away from home. This will stop the immerSUN from heating. The timed boost will also not operate.
Set Date & Time
The date time should be set during installation. Use this menu option to change the current date or time. The date & time will be retained during a power outage for at least 2 days.
Set Backlight
The display backlight can be set to illuminate for a few seconds after a button press. Also the backlight can be set to illuminate whenever the unit is heating and/or boosting.
Set Contrast
The display contrast can be adjusted if required.
Savings
Savings made by the immerSUN are accumulated. The savings are shown in kWh as well as in currency. The savings are displayed for Today, this Week, Month and the total this year. Also the total savings since installation are shown.
Boost Times
Boost times can be set to turn on the selected heater at full power regardless of surplus export power available.
Menu
MAIN MENU Savings Boost Times Holiday Mode Set Date & Time Set Display
MAIN MENU Savings Boost Times Holiday Mode Set Date & Time Set Display
SAVINGS Today: 2.5kWh £0.36 Week : 16kWh £2.30 Month: 74kWh £10.15 Year : 315kWh £45.09 Total: 315kWh £45.09
SAVINGS Today: 2.5kWh £0.36 Week : 16kWh £2.30 Month: 74kWh £10.15 Year : 315kWh £45.09 Total: 315kWh £45.09
BOOST TIMES 06:30-07:30 MTWTFSS - 16:30-17:30 MTWTFSS - 07:30-08:30 MTWTFSS - 17:30-18:30 MTWTFSS - 08:30-09:30 MTWTFSS - 18:30-19:30 MTWTFSS -
BOOST TIMES 06:30-07:30 MTWTFSS ­16:30-17:30 MTWTFSS ­07:30-08:30 MTWTFSS ­17:30-18:30 MTWTFSS ­08:30-09:30 MTWTFSS ­18:30-19:30 MTWTFSS -
HOLIDAY MODE
Press to put unit in standby Press to cancel.
HOLIDAY MODE
Press to put unit in standby Press to cancel.
SET DATE & TIME
Date: 16.02.14 Time: 11:34
Press then use to make changes.
SET DATE & TIME
Date: 16.02.14 Time: 11:34
Pressthen use to make changes.
SET DISPLAY Set Backlight Set Contrast
SET DISPLAY Set Backlight Set Contrast
SET BACKLIGHT Button Press : 30s When Heating : ON When Boosting: ON
Press then use to make changes.
SET BACKLIGHT Button Press : 30s When Heating : ON When Boosting: ON
Pressthen use to make changes.
SET CONTRAST
Contrast: 50%
Press then use to make changes.
SET CONTRAST
Contrast: 50%
Pressthen use to make changes.
p7
p5
The Menu is accessed by pressing the button from the main screen. Use the and buttons to select the required menu item, then press the button to select the menu option. Press the button to exit or go back from a menu.
9
Set Tariff Priority:1-2 View Readings View Configuration Advanced Settings Lock Advanced
Set Tariff Priority:1-2 View Readings View Configuration Advanced Settings Lock Advanced
Set Tariff
The tariff should be set to that shown on your utility bill. You will need to adjust the tariff from time to time as the tariff changes. The tariff should be that of the fossil fuel you normally use to heat the appliance. The New tariff will take effect From the date entered, which can be a past or future date, meaning the New tariff does not need to be set on the day it changes.
Set Heater Priority
If two or three heaters are connected, the heating sequence can be selected. The higher priority heater will be heated until the thermostat opens, then the next priority heater will start to be heated and so on. When heating a lower priority heater, the unit will switch back to the higher priority heater periodically, this period is set by
Check Period in the Advanced Settings menu.
If the heating priority is set to Equal, then each heater will be heated in-turn for the time set by the Check Period in the Advanced Settings menu.
View Configuration
This screen gives an overview of the immerSUN configuration It is useful to check the current settings.
SET TARIFF Current : £000.145 New : £000.145 From : 01/01/14
Press then use to make changes.
SET TARIFF Current : £000.145 New : £000.145 From : 01/01/14
Pressthen use to make changes.
VIEW READINGS
VIEW READINGS
ADVANCED SETTINGS
ADVANCED SETTINGS
p12
SET HEATER PRIORITY
Priority: 1-2-3
Press then use to make changes.
SET HEATER PRIORITY
Priority: 1-2-3
Pressthen use to make changes.
p10
VIEW CONFIGURATION HEATER 1 TYPE Immersion (Top) HEATER 2 TYPE Immersion (Bot) HEATER 3 TYPE Disabled MINIMUM EXPORT: 50W HEATER PRIORITY 1-2 RELAY FUNCTION When Heating 1,2 Include Boost EXTERNAL BOOST Boost Heater 1,2 SESNOR TYPE Wired IMMERLINK Unit: Master Slaves : 0 Channel : 1 off Net ID : f428 Gateway PW : 3b5b4436
VIEW CONFIGURATION HEATER 1 TYPE Immersion (Top) HEATER 2 TYPE Immersion (Bot) HEATER 3 TYPE Disabled MINIMUM EXPORT: 50W HEATER PRIORITY 1-2 RELAY FUNCTION When Heating 1,2 Include Boost EXTERNAL BOOST Boost Heater 1,2 SESNOR TYPE Wired IMMERLINK Unit: Master Slaves : 0 Channel : 1 off Net ID : f428 Gateway PW : 3b5b4436
Lock Advanced
Lock Advanced
Lock Advanced
If ticked the Advanced Settings menu is locked,
the passcode will need to be entered to access the menu. If the Advanced Settings menu is unlocked, the menu can be immediately locked by selecting this option.
10
MAIN MENU
View Readings
MAIN MENU
View Readings
View Readings
This screen shows various readings and other information. See the list below for a description of the readings. This screen is useful for diagnosing installation issues.
Title Description
Version: Firmware version number and hardware type. Serial No: Serial number of the unit. Input V: Supply input AC voltage. Grid V: Voltage of the supply connected to the Wireless Sensor
(where fitted), otherwise the same as Input V.
Max Voltage: Maximum supply voltage recorded since last switch on. Min Voltage: Minimum supply voltage recorded since last switch on. Grid I: Current seen by the sensor clamp. Frequency: Supply frequency. Exporting/ Importing: Power level currently being imported or exported. Current: Input current of the unit. Output: Power being delivered to the load. P.W.M: Output voltage percentage. Heatsink: Temperature of the internal heatsink. Protects: Count of over-current protections since switch on Sig Qual: Signal quality of immerLINK™ wireless connection. Cal Date: Date the unit was calibrated at the factory. Reset: Date the unit was factory reset. Power Off: Last date and time power was lost to to unit. Last Error: Last error number with date and time.
VIEW READINGS Version : 2.30.0/1 Serial No : 20546 Input V : 245V Grid V : 0V Max Voltage: 248V Min Voltage: 232V Grid I : -0.1A Frequency : 50.0Hz Exporting : 25W Current : 8.9A Output : 2108W P.W.M. : 94% Heatsink : 44°C Protects : 0 Sig Qual : 91% Cal date : 20/10/2013 Reset : 16/02/2013 Power off : 20/10/2013 at : 16:36 Last Error : None
VIEW READINGS Version : 2.30.0/1 Serial No : 20546 Input V : 245V Grid V : 0V Max Voltage: 248V Min Voltage: 232V Grid I : -0.1A Frequency : 50.0Hz Exporting : 25W Current : 8.9A Output : 2108W P.W.M. : 94% Heatsink : 44°C Protects : 0 Sig Qual : 91% Cal date : 20/10/2013 Reset : 16/02/2013 Power off : 20/10/2013 at : 16:36 Last Error : None
11
Advanced options...
12
ADVANCED SETTINGS Heater 1 Type Heater 2 Type Heater 3 Type Minimum Export Check Period Relay Function External Boost Immerlink Set Passcode Locked Functions Daylight Savings Time Factory Reset
ADVANCED SETTINGS Heater 1 Type Heater 2 Type Heater 3 Type Minimum Export Check Period Relay Function External Boost Immerlink Set Passcode Locked Functions Daylight Savings Time Factory Reset
Heater Type
The heater type can be set for each heater connected. Each heater type is represented by a different symbol on the main screen.
Check Period
This is the time between checking to see if the priority heater(s) can accept more heat. e.g. Once the heater is at max. temperature, the unit will switch to the next priority heater, however, it will switch back again after the set Period to check if there is a demand for heat from the higher priority heater.
Advanced Settings
Advanced Settings Menu
Advanced Settings are accessed via the Main Menu – Advanced Settings Option.
HEATER 1 TYPE None Immersion T Immersion B Heater Underfloor Pool
HEATER 1 TYPE None Immersion T Immersion B Heater Underfloor Pool
CHECK PERIOD
Period: 15 min
Press then use to make changes.
CHECK PERIOD
Period: 15 min
Pressthen use to make changes.
RELAY FUNCTION
RELAY FUNCTION
p14
EXTERNAL BOOST
EXTERNAL BOOST
p13
MAIN MENU
Advanced Settings
MAIN MENU
Advanced Settings
IMMERLINK
IMMERLINK
FACTORY RESET
Reset Config Reset Savings Reset Immerlink Execute Press to cancel.
FACTORY RESET
Reset Config Reset Savings Reset Immerlink Execute Press to cancel.
Factory Reset
To restore all settings to factory defaults, use this function.
Reset Config and Reset Savings can be individually
selected.
p19
MINIMUM EXPORT
Minimum Export: 50W
Press then use to make changes.
MINIMUM EXPORT
Minimum Export: 50W
Pressthen use to make changes.
Minimum Export
This is the minimum level of export power, the default is 50W to ensure that the electricity meter does not register any import when the immerSUN is diverting energy.
SET PASSCODE
0 0 0 0
SET PASSCODE
0 0 0 0
Set Passcode
The passcode to access the Advanced Settings menu can be changed in this screen.
LOCKED FUNCTIONS Set Date & Time Boost Times Manual Boost Set Tariff Set Priority
LOCKED FUNCTIONS Set Date & Time Boost Times Manual Boost Set Tariff Set Priority
DAYLIGHT SAVINGS TIME Enabled Last Sunday March & October
Press to exit.
DAYLIGHT SAVINGS TIME Enabled Last Sunday March & October
Press to exit.
Locked Functions
Some functions can be hidden from the main menu to prevent accidental changes. Use this option to enable or disable these functions.
Daylight Savings Time
Enable or disabled automatic clock adjustment for Daylight Savings Time (DST). When enabled the clock will be adjusted forward by one hour March and back one hour in October.
13
What Does It Do?
This is an external input which can be used to trigger a boost or enable/disable heater outputs. The External Boost input is the 2-terminal connector labelled EX BST. Any AC voltage from 24V to 240V present on these terminals will be recognised by the immerSUN.
EXTERNAL BOOST Disabled Boost Heater Heater Thermostat
EXTERNAL BOOST Disabled Boost Heater Heater Thermostat
Boost Heater
The selected heater(s) will be boosted whenever the EX BST signal is present. If more than one heater is selected, the heaters will be boosted sequentially in the priority order.
Heater Thermostat
The EX BST input will act as a thermostat for the selected heater(s). The heater output will only be active when there is a signal at the EX BST input, otherwise the heater will show as HOT on the main screen.
External Boost Input
EX BST External Boost Input
24 – 240VAC Sense Input
This input is isolated
EXTERNAL BOOST
HEATER THERMOSTAT Heater 1 Heater 2
EXTERNAL BOOST
HEATER THERMOSTAT Heater 1 Heater 2
ADVANCED SETTINGS
External Boost
ADVANCED SETTINGS
External Boost
MAIN MENU
Advanced Settings
MAIN MENU
Advanced Settings
Disabled
A voltage at EX BST will have no effect, the input is disabled.
EXTERNAL BOOST
BOOST HEATER Heater 1 Heater 2
EXTERNAL BOOST
BOOST HEATER Heater 1 Heater 2
14
ADVANCED SETTINGS
Relay Function
ADVANCED SETTINGS
Relay Function
MAIN MENU
Advanced Settings
MAIN MENU
Advanced Settings
RELAY FUNCTION Disabled Always On When Heating When Boosting Boiler Boost Destrat Pump
RELAY FUNCTION Disabled Always On When Heating When Boosting Boiler Boost Destrat Pump
RELAY:WHEN HEATING
Heater 1 Heater 2
Include Hot Include Boost
RELAY:WHEN HEATING
Heater 1Heater 2
Include Hot Include Boost
RELAY:WHEN BOOSTING
Heater 1 Heater 2
RELAY:WHEN BOOSTING
Heater 1Heater 2
RELAY:DESTRAT PUMP
Heater 1 Heater 2
RELAY:DESTRAT PUMP
Heater 1Heater 2
When Heating
The relay will operate whenever the selected heater(s) are being heated. Include Hot If ticked the relay will remain closed when the heater has reached max. temperature and it's thermostat is open. Include Boost If ticked the relay will also operate during timed or manual boost.
When Boosting
The relay will operate whenever the selected heater(s) are being boosted, either with manual boost or timed boost.
Boiler Boost
The relay will operate whenever a manual boost or timed boost is activated for the selected heater(s). The heater will NOT be boosted by the immerSUN but will heat as normal. Instead an auxiliary boiler will be called to boost.
Destrat Pump
Once the heater thermostat opens, the relay will operate (to run a destratification pump). The pump will run for the duration set by the Check Period option in the Advanced Settings menu.
Disabled
The relay will never operate..
Always On
The relay will be ON. This function is useful for testing circuits connected to the relay contacts.
Multifunction Relay
Multifunction Relay Settings
The settings for the Multifunction Relay can be accessed via the
Advanced Settings Menu. The relay function
is selected from a list. Some functions have options which can be defined.