Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas Customer, you can also count on a qualied aer-sales service, prepared and updated to guarantee constant eciency of your water heater. Read the following pages carefully: you will be able to draw useful tips on the proper use of the device, compliance with which will conrm your satisfaction with the Immergas product.
For assistance and scheduled maintenance contact Authorised Aer-Sales centres: they have original spare parts and are specically trained directly by the manufacturer.
General warnings
All Immergas products are protected with suitable transport packaging. e material must be stored in a dry place protected from the weather. e instruction booklet is an integral and essential part of the product and must be given to the new user in the case of transfer or succession of ownership. It must be stored with care and consulted carefully, as all of the warnings provide important safety indications for installation, use and maintenance stages. is instructions manual provides technical information for installing Immergas water heaters. As for the other issues related to water heater installation (e.g.
safety in the work site, environment protection, injury prevention), it is necessary to comply with the provisions of the regulations in force and the principles of good practice.
Installation and maintenance must be performed in compliance with the regulations in force, according to the manufacturer's instructions and by an authorised company, which has the specic technical skills in the system sector, as provided for by Law.
Improper installation or assembly of the Immergas appliance and/or components, accessories, kits and devices can cause unexpected problems for people, animals and objects. Read the instructions provided with the product carefully to ensure proper installation.
Maintenance must be carried out by an authorised company. e Authorised Aer-sales Service represents a guarantee of qualication and professionalism. e appliance must only be destined for the use for which it has been expressly declared. Any other use will be considered improper and therefore potentially
dangerous. If errors occur during installation, operation and maintenance, due to non-compliance with technical laws in force, standards or instructions contained in
this book (or however supplied by the manufacturer), the manufacturer is excluded from any contractual and extra-contractual liability for any damage and the appliance warranty is invalidated.
e company IMMERGAS S.p.A., with registered oce in via Cisa Ligure 95 42041 Brescello (RE), declares that the design, manufacturing and aer-sales assistance processes comply with the requirements of standard UNI EN ISO 9001:2015.
For further details on the product CE marking, request a copy of the Declaration of Conformity from the manufacturer, specifying the appliance model and the language of the country.
e manufacturer declines all liability due to printing or transcription errors, reserving the right to make any modications to its technical and com­mercial documents without forewarning.
INDEX
1 Installation water heater. ..........................5
1.1 Installation recommendations. ................5
1.2 Main dimensions. ......................................6
1.3 Gas connection. ......................................... 6
1.4 Hydraulic connection. ..............................7
1.5 Electric power supply. ............................... 7
1.6 Ventilation of the rooms...........................7
1.7 Flue ducts. .................................................. 7
1.8 Flues/Chimneys. ........................................7
1.9 Gas system start-up. ..................................7
1.10 Appliance start-up (ignition). ................... 7
1.11 Kits available on request. .......................... 7
1.12 Water heater components. .......................8
USER page INSTALLER page MAINTENANCE TECHNICIAN page
2 Instructions for use and maintenance. ... 9
2.1 Cleaning and maintenance. .....................9
2.2 Ventilation of the rooms...........................9
2.3 General warnings. ..................................... 9
2.4 Control panel. ............................................9
2.5 Use of the water heater. ............................9
2.6 Description of the anomalies. ................10
2.7 Switch-o of the water heater. ...............11
2.8 Battery replacement. ...............................11
2.9 Emptying the water heater. .................... 11
2.10 Protection against freezing. ...................11
2.11 Cleaning the case. .................................... 11
2.12 Decommissioning. ..................................11
2.13 Gas system not used for periods
over 12 months. .......................................11
3 Control and maintenance. .....................12
3.1 Hydraulic Diagram. ................................12
3.2 Chimney safety thermostat reset. .........13
3.3 Wiring diagram. ......................................13
3.4 Possible problems and their causes. ......14
3.5 Converting the water heater to other
types of gas. .............................................. 14
3.6 Transformation from methane to LPG. 14
3.7 Transformation from LPG to methane. 15
3.8 Possible adjustments. ..............................15
3.9 Yearly appliance check and
maintenance. ............................................16
3.10 Casing removal. .......................................16
3.11 Combustion parameters. ........................16
3.12 Technical data. .........................................17
3.13 Product che (in compliance with
Regulation 812/2013). ............................18
INSTALLATION
1
WATER HEATER.
1.1 INSTALLATION RECOMMENDATIONS.
e Julius Eco 11-14 water heater has been de­signed for wall installation. It must be used for the production of domestic hot water and similar purposes. In the case of wall installation the wall surface must be smooth, without any protrusions or recesses enabling access to the rear part. ey are not designed to be installed on plinths or oors (Fig. 1-1).
e place of installation of the appliance and relative Immergas accessories must have suitable features (technical and structural), such as to al­low for (always in safe, ecient and comfortable conditions):
- installation (according to the provisions of
technical legislation and technical regulations);
- maintenance operations (including scheduled,
periodic, routine and special maintenance);
- removal (outdoors in the place for loading and
transporting the appliances and components) as well as their eventual replacement with ap­pliances and/or equivalent components.
Only professionally qualified companies are authorised to install Immergas gas appliances. Installation must be carried out according to regulation standards, current legislation and in compliance with local technical regulations and the required technical procedures.
Attention: it is forbidden to install appliances removed from other systems. e manufacturer declines all liability in the event of damage caused by water heaters removed from other systems or for any non-conformities with such equipment.
Installation of the Julius Eco 11-14 water heater when powered by LPG must comply with the rules regarding gases with a greater density than air (remember, as an example, that it is prohibited to install systems powered with the above-mentioned gas in rooms where the oor is at a lower quota that the average external country one).
Before installing the appliance, ensure it has been delivered in perfect condition; if in doubt, contact the supplier immediately. Packing materials (sta­ples, nails, plastic bags, polystyrene foam, etc.) constitute a hazard and must be kept out of the reach of children.
If the appliance is installed inside or between cabinets, ensure sufficient space for normal servicing; therefore it is advisable to leave clear­ance of at least 50 cm between the water heater casing and the vertical sides of the cabinet (Ref. Fig. 1-1A). Leave adequate space above the water heater for possible water and ue removal connections.
Do not rest objects on the appliance. Keep all ammable objects away from the ap­pliance (paper, rags, plastic, polystyrene, etc.). It is recommended not to position household appliances under the water heater because they could undergo damage in the case of leaks from the hydraulic ttings. If this is not the case, the manufacturer cannot be considered liable for any damage caused to the household appliances. For the aforementioned reasons, we recommend not placing furnishings, furniture, etc. under the water heater. In the event of malfunctions, faults or incorrect operation, turn the appliance o and contact an authorised company (e.g. the Authorised Tech­nical Assistance centre, which has specically trained sta and original spare parts). Do not attempt to modify or repair the appliance alone. Failure to comply with the above implies personal responsibility and invalidates the warranty.
• Installation Standards:
- these water heaters cannot be installed in bedrooms, studio ats and bathrooms. ey also cannot be installed in rooms with wood (or solid fuel) burning heat generators and in communicating rooms.
- Installation in places with a re risk is pro­hibited (for example: underground car parks, garages), potentially dangerous places, gas appliances and relative ue ducts.
- Installation on the vertical projection of cook­ing hobs is forbidden.
- Installation is forbidden in places/rooms that constitute public areas of apartment build­ings, internal stairways or other escape routes (e.g. oor landings, entrance halls, etc.).
- Installation is also forbidden in places/rooms that constitute public areas of apartment buildings such as cellars, entrance halls, at­tics, los, etc., unless otherwise provided for by local regulations in force.
- It is forbidden to install the water heater inside a closed recessed frame (e.g. Omni Container).
- Type B open chamber water heaters must not be installed in places where commercial, artisan or industrial activities take place, which use products that may develop volatile vapours or substances (e.g. acid vapours, glues, paints, solvents, combustibles, etc.), as well as dusts (e.g. dust deriving from the working of wood, coal nes, cement, etc.). ese may be damaging for the components of the appliance and jeopardise functioning.
- ey must also be installed in an environ­ment in which the temperature cannot fall below 0°C. They must not be exposed to atmospheric agents.
YES NO
Attention: wall mounting of the water heater
must guarantee stable and ecient support for the generator. e dowels, which come as standard, can only ensure adequate support if inserted correctly (according to technical standards) in walls made of solid or semi-hollow brick or block. In the case of walls made from hollow brick or block, partitions with limited static properties, or in any case walls other than those indicated, a static test must be carried out to ensure adequate mount.
ese appliances are used to heat water to below boiling temperature in atmospheric pressure. ey must be connected to a DHW distribution network suited to their performance and power.
Minimum installation distances.
Fig. 1-1
50 50
INSTALLERUSER
MAINTENANCE TECHNICIAN
JULIUS ECO
200
Fig. 1-1A
5
1.2 MAIN DIMENSIONS.
Julius Eco 11
INSTALLERUSER
CONNECTIONS
GAS DOMESTIC HOT WATER
G AC AF
* 1/2” 1/2” 1/2”
* Connection unit optional available with 3/4” cock
Julius Eco 14
MAINTENANCE TECHNICIAN
1.3 GAS CONNECTION.
Our water heaters are designed to operate with methane gas (G20) and LPG. Supply pipes must be the same as or larger than the 1/2”G water heater tting. Before connecting the gas line, carefully clean inside all the fuel feed system pipes to remove any residue that could impair water heater eciency. Also make sure the gas corresponds to that for which the water heater is prepared (see water heater data-plate). If dif­ferent, the water heater must be converted for operation with the other type of gas (see con­verting appliance for other gas types). It is also important to check the dynamic pressure of the mains (methane or LPG) used to supply the water heater, which must comply with EN437 and its attachment, as insucient levels may reduce gen­erator output and cause discomfort to the user.
Key: AC - Domestic hot water outlet AF - Domestic cold water inlet G - Gas supply
A type-approved and certied gas cut-o cock must be inserted on the gas pipe before connec­tion to the appliance. Ensure correct gas cock connection, by inserting a at gasket. e gas supply pipe must be suitably dimensioned according to current regulations in order to guarantee correct gas ow rate to the burner even in conditions of maximum genera­tor output and to guarantee appliance eciency (technical specications). e coupling system must conform to standards in force (EN 1775).
Fig. 1-2
Fuel gas quality. e appliance was designed to operate with combustible gas free of impuri­ties; otherwise it is advisable to t special lters upstream of the appliance to restore the purity of the fuel.
Storage tanks (in case of supply from LPG depot).
- New LPG storage tanks may contain residual inert gases (nitrogen) that degrade the mixture delivered to the appliance casing functioning anomalies.
- Due to the composition of the LPG mixture, layer­ing of the mixture components may occur during the period of storage in the tanks. is can cause a variation in the caloric value of the mixture delivered to the appliance, with subsequent change in its performance.