This manual contains important laser system safety and operation
information. Read and understand all instructions prior to powering on
laser unit the first time, to avoid laser eye injury and to avoid breaking
the law. Keep this manual in a safe place for future reference.
USER MANUAL
1
WARNING DATA
Lasers can be hazardous and have unique safety considerations.
Permanent eye inju ry an d blin dness i s po s sible i f l aser s ar e use d
incorrectly. Pay close attention to each safety REMARK and
WARNING statement in the user manual. Read all instructions
carefully BEFORE operating this device.
Attention!
Important!
Caution!
Laser!
Recycle
Indoor
Wastebin
LLocation
Indicates a skill or other useful information for special
situations.
Indicates important information, to protect people from laser
incident or damage
Prevent damage or injury from incorrect opera tion.
Laser safety warming labels.
To protect the environment, recycle packing material
wherever possible.
The projector is for indoor use only, IP20. Use only in dry
locations. Keep this device away from rain and moisture,
excessive heat, humidity and dust. Do not allow contact with
water or any other fluids, or metallic objects.
Don’t throw this product away just as general trash, please
dispose of this product following the abandon electronic
product regulation in your country.
The projector must be installed in a location with adequate
ventilation, at least 50cm (20inches) from adjacent surfaces.
Be sure that no ventilation slots are blocked.
USER MANUAL
2
installation, safe use and service!
LAS ER SAFETY WAR NINGS
Potential laser injury hazard exists with this product! Read these
Instructions carefully, which include important information about
CautionAvoid direct eye contact with laser 了 light. Never
intentionally expose your eyes or others to direct laser
radiation.
Caution This laser product can potentially cause instant eye
injury or blindness if laser light directly strikes the eyes.
Caution It is illegal and dangerous to shine this laser into
audience areas, where the audience or other personnel
could get direct laser beams or bright reflections into
their eyes.
Caution It is a US Federal offense to shine any laser at aircraft.
Caution There are no user serviceable parts inside the unit. Do
not open the housing or attempt any repairs yourself. In
the unlikely event your unit may require service, please
contact the dealer nearest to you..
Caution Use of controls or adjustments or performance of
procedures other than those specified herein may result
in hazardous radiation exposure.
NON-INTERLOCKED HOUSING WARNING
This unit conta ins high power laser device s i n ternally. Do not open the laser
housing, due to potential exposure to unsafe levels of laser radiation. The
laser power levels accessible if the unit is opened can cause instant
blindness, skin burns and fires.
USER MANUAL
3
LASER SAFETY AND OPERATING INSTRUCTIONS
STOP AND READ ALL LASER SAFE TY DATA
Laser light is different from any other light source witch you may be familiar. The
light from this product can potentially cause eyes injury if not set up and used
properly.
Laser light is thousand s of tim es m ore con centrated than light fro m any ot her k in d
of light source. This concentration of light power can cause instant eye injuries,
primarily by burning the retina (the light sensitive portion at the back of the eye).
Even if you can not feel “heat” from a laser beam, it can still potentially injure or
blind you or your audience. Even very small amounts of laser light are potentially
hazardous even at long distances. Laser eye injuries can happen quicker than
you can blink.
It is incorrect to think that because these laser entertainment products split the
laser into hundreds of beams or laser beam is scanned out in high speed, that an
individual laser beam is safe for eye exposure. This laser product uses dozens of
milliwatts of laser power (Class 4 levels internally). Many of the individual beams
are potentially hazardous to the eyes.
It is also incorrect to assume that because the laser light is moving, it i s saf e. This
is not true. Nor, do the laser beams always move. Since eye injuries can occur
instantly, it is critical to prevent the possibility of any direct eye exposure. In the
laser safety regulation, it is not legal to aim Clas s 4 lasers in a reas whi ch pe ople
can get exposed. This is true even if it is aimed below people’s faces, suc h as on
a dance floor.
Do not operate laser without first reading and understanding all safety and
technical data in this manual.
Always set up and install all laser effects so that all laser light is at least 3
meters (9.8 feet) above the floor on which people can stand. See “Proper
Laser Set-up & Usage” section later in this manual.
After set up, and pri or to public use test laser to en sure prop e r function . Do n ot
use if any defect is detected. Do not use if laser emits only one or two laser
beams rather than dozens/hundreds, as this could indicate damage to the
diffraction grating optic, and could allow emission of higher laser levels.
USER MANUAL
4
Do not point lasers at people or animals.
Never look into the laser aperture or laser beams.
Do not point lasers in areas in which people can potentially get exposed. such
as uncontrolled balconies, etc.
Do not point lasers at highly reflective surfaces such as windows, mirrors and
shiny metal. Even laser reflecti ons can be hazardous
Never point a laser at aircraft, this is a federal offense.
Never point un-terminated laser beams into the sky.
Do not expose the output optic (aperture) to cleaning chemicals.
Do not use laser if the laser appears to be emitting only one or two beams.
Do not use laser if housing is damaged or open, or if optics appear damaged
in any way.
Never open the laser housing. The high laser power levels inside of the
protective housing can start fires, burn skin and will cause instant eye injury.
Never leave this device running unattended.
The operation of a Class 4 laser show laser is only allowed if the show is
controlled by a skilled and well-trained operator familiar with the data included
in this manual..
The legal requirements for using laser entertainment products vary from
country to country.The user is responsible for the legal requirements at the
location/country of use.
Always use appropriate lighting safety cables when hanging lights and effects
overhead.
For the operation of the laser the “INTERLOCK CONNECTOR” must be
connected.
FOR GERMANY: Customers have to use an ”EMERGENCY SWITCH”
together with the “INTERLOCK CONNECTOR”.
LASER EXPOSURE WARNING
LASER LIGHT
AROVID DIRECT EYE EXPOSURE
Further guidelines and safety programs for safe use of lasers can be found in the
ANSI Z136.1 Standard “For Safe Use of Lasers”, available from
“www.laserinstitute.org”. Many local governments, corporations, agencies,
military and others, require all lasers to be used under the guidelines of ANSI
Z136.1. Laser Display guidance can be obtained via the International Laser
Display Association, www .laserist.or g.
USER MANUAL
5
LASER SAFETY LABEL REPRODUCTIONS
Caution – Class 3B LASER RADIATION,
WHEN OPEN, AVOID EXPOSURE TO
BEAM
LASER RADIOATION AVOID EXPOSURE
TO BEAM CLASS 3B LASER PRODUCT.
The label indicates the laser beam output
aperture.
LASER EMISSION DATA
Laser Classification Class 3B
Green Laser Medium DPSS Nd:YVO4,532nm
Red Laser Medium LD GaAIAs 650nm,typical
Beam Diameter <5mm at aperture
Divergence(each beam) <12 mrad
Divergence(total light) <90 degrees
Laser power R>100mW, G>40mW
Transverse Beam Mode TEM00
Cooling TEC & Fan Cooling
Scanning ILDA 15Kpps
* As measured under IEC measurement conditions for classification.
USER MANUAL
6
you can suffer a dangerous electric shock when
Note: The laser diode is exposed to extreme conditions due to the
high output power and therefore only has a limited life. Like all
wear parts, the laser diode is not subject to any guarantee claims.
LASER COMPLIANCE STATEMENT
This laser product complies with EN/IEC 60825-1 Ed 2,2007-03.
GENERAL SAFETY INSTRUCTIONS
Every person involved with installation and maintenance of this device have to
Be qualified.
Follow the instructions of this manual.
CAUTION! Be careful with your operations. With a high voltage
touching the wires!
This device has left out premises in absolutely perfect condition. In order to
maintain this condition and to ensure a safe operation, it is necessary for the user
to follow the safety instructions and warning notes written in this manual.
Important! The manufacturer will not accept liability for any resulting
damages caused by the non-observance of this manual or any
unauthorized modification to the devic e.
Please consider that damages caused by manual modifications to the devise
are not subject to warranty.
Never let the power-cord come into contact with other cables! Handle the
power-cord and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear
panel.
Always plug in the power plug least. Make sure that the power-switch is set to
off-position before you connect the device to the mains. The power-plug has
to be accessed after installing the device.
Make sure that the power-cord is never crimped or damaged by sharp edges.
Check the device and the power-cord from time to time.
USER MANUAL
7
the result of unprofessional operation
damages and the warranty word.
Always disconnect from the mains, when the devise is not in use or before
cleaning it. Only handle the power-cord by the plug. Never pull out the plug by
tugging the power-cord.
It is essential to connect the yellow/green conductor to earth.
The electric connection, repairs and servicing must be carried out by a
qualified employee.
Do not switch the fixture on and off in short intervals as this would reduce the
laser diode life.
For replacement, please use fuses of same type and rati ng only.
If the device has been exposed to drastic temperature fluctuation, do not
switch it on immediately. The arising condensation water might damage your
device. Leave the device switched off until it has reached room temperature..
Do not shake the device. Avoid brute force when installing or operating the
device.
When choos ing the ins tallation-spot, please make sure that the device is not
exposed to extreme heat, moisture or dust. There should not be any cables
lying around. You endanger your own and the safety of others!
The minimum distance between the fixture and surrounding walls must be
more than 50cm.
Always fix the fixture with an appropriate safety-rope. Fix the safety-rope at
the safety-rope only.
The ambient temperature must be between 10℃ to 40℃.
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden
due to safety reasons!
CAUTION! Operate the device only after having familiarized with
its functions. Do not permit operation by persons not
qualified for operating the device. Most damages are
CAUTION! If this device will be operated in any way different to the
one described in this manual, the product may suffer
USER MANUAL
8
BEFORE OPERATION
Unpacking Instructions
CAUTION! Immediately upon receiving a fixture, carefully unpack the
carton, check the contents to ensure that all parts are present,
and have been received in good condition. Notify the shipper
immediately and retain packing material for inspection if any
parts appear damage from shipping or the package itself
shows signs of mishand lin g. Save the package and all packing
materials. In the event that a fixture must be returned to the
factory, it is importan t tha t the fixture be returned in t h e ori gin al
factory box and packing.
What is included
The carton or flight case contain following items:
To determine the power requirements for a particular fixture, see the label affixed
to the back plate of the fixture of refer to the fixture’s specifications chart. A
fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0 % to 100 % switch. B efore ap pl ying pow er to a fix ture,
check that the source voltage matches the fixture’s requirement.
USER MANUAL
9
The unit is supplied with a power plug appropriate to its voltage and
destination. Should any other connections be required they must be
carried out with the following configuration.
Cable(EU) Cable(US) Pin International
Brown Black Live L
Liht blue White Neutral N
Yellow/Green Green Earth
DMX-512 connection between fixtures
The fixture is equipped with 2-pin XLR sockets for DMX input and output. The
sockets are wired in parallel. Only use a shielded twisted-pair cable designed for
3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection
Caution: At the laser fixture, the DMX-cable has to terminated with a
terminator. Solder a 120 Ohm resistor between Signal (-) and
Signal (+) into a 3-pin XLR-plug and plug and plug it in the
DMX-output of the last fixture.
USER MANUAL
10
Building a serial DMX-chain
If you are using the standard DMX-controllers, you can connect the
DMX-output of the controller directly with the DMX-input of the first fixture in
the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter cables.
Connect the DMX-output of the first fixture in the DMX-chain with the
DMX-input of the next fixture. Always connect output with the input of the next
fixture until all fixtures are connected.
If you use a controller with 5 pins DMX connector, you need to use a 5 to 3
pins adpter
At last fixture, the DMX cable has to be terminated with a terminator. Solder a
120 Ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3 pins
XLR-plug and plug it in the DMX-output of the last fixture.
Connect the fixture together in a daisy chain by XLR plug cable from the
output of the fixture to the input of the next fixture. The cable cannot be
branched or split to a Y cable. DMX 512 is a very high speed signal.
Inadequate or damaged cables, soldered joints or corroded connectors can
easily distort the signal and shut down the system.
The DXM output and input connectors are pass-through to maintain the DMX
circuit, when power is disconnected to the unit.
Each fixture needs to have a DMX address to receive the data from the
controller. The DMX address number which could be read from rear panel of
each fixture is between 000~511.
The end of the DMX 512 chain should be terminated to reduce signal errors.
Proper Laser Set Up & Usage
This fixture has been design ed to be hung . It is re comme nded for safe ty purposes,
your lighting effect are properly mounted using a suitable hanging clamp and
USER MANUAL
11
by an authorized employee or dealers!
safety cable. Items appropriate for safe and effective mounting are easily
sourced from your lighting vendor.
International laser safety regulations require that lasers must be operated in the
fashion illustrated b elow, with a minimum of 3 meters (9.8 ft) of vertical separ at ion
between the floor and the lowest laser light vertically. Additionally, 2.5 meters of
horizontal separation is required between laser light and audience or other public
spaces.
Rigging the Fixture
CAUTION! Please consider the respective national norms during
the installation! The ins t allati on must only be carried out
The installation of the fixture has to be built and constructed in a way that it
can hold 10 times the weight for 1 hour without any harming deformation..
The installation must always be secured with a secondary safety attachment,
e.g. an appropriate catch net. This secondary safety attachment must be
constructed in a way that no part of the installation can fall down if the main
attachment fails.
USER MANUAL
12
Make sure the area be low the installat ion p lac e is free from u nwanted persons
during rigging, de-rigg ing and serv icing.
The operator has to make sure that safety-relating and machine-technical
installations are ap prov ed by an expert be fore taking into operat ion for t h e first
time and after changes before taki ng into oper a tio n another ti me.
The operator has to make sure that safety-relating and machine-technical
installations are approved by a skilled person once a year.
The fixture should be installed in t he position where perso ns cann ot reach and
where persons may walk by or be seated.
CAUTION! When installing the device, make sure there is no highly
in inflammable material (decoration articles, etc.) in
between a distance of min 0.5 meter.
PRODUCT OVERVIEW
This device has left out premise in absolutely perfect condition. In order to
maintain this condition and to ensure safe operation, it is necessary for the
user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorized modification to the
device.
USER MANUAL
13
/ IR
with 2 knobs on both sides to fasten the unit and
Front Panel
NO NAME FUNCTION
1 Laser output
2 POWER
3 MUSIC/IR
4 IR
5 Cooling fan
HANGING
6
BRACKET
Laser output aperture.
Main power indicated LED. Red is ON.
Synchronize to detected music signal
indicator (flashing for each signal received)
Infrared Remote Receiver
Cooling and never cover this fan outlet
a mounting hole to fix a mounting hook.
USER MANUAL
14
Rear Panel
NO NAME FUNCTION
7 Switch
8 Mains input
9 Key switch
10 Interlock connector
11 LED control Panel
12 Sa fety eye
13 DMX input
14 DMX output
Switch on and off the power
With socket and integrated fuse holder
Make sure the professional person use
For emergency laser stop
Intelligent LED control pan el of the syste m
Attach the safety cable
3PIN Male XLR port, using for DMX
3PIN Female XLR port,using for DMX
CONTROL & FUNCTION
Regular breaks during operation are essential to maximize the life of this
device as it is not designed for continual use.
Do not switch the unit on and off in short time intervals
Always unplug the unit when it is not used for a longer time. Or before
replacing the bulb or start servicing.
In the event of serious operation problems, stop using the fixture and contact
your dealer immediately.
USER MANUAL
15
Attention Laser Safety Scanner Board is included in the system.
The Laser light will be turned off when the scanned angle
is less than 1 degree.
Operating Mode
Attention Once after every power on laser, the VERSION and
MANUFACTURE INFORMATION will be shown in LCD
monitor of rear panel.
When laser is powered on, LCD monitor on rear panel shows the current
operating standalone mode or DMX address of DMX mode. With help of LCD
control panel, is very easy to set and change the operating mode of laser. After
every resetting and saved, the new mode information will be shown on LCD
monitor at next power on.
Mode Option, to choose the operating mode of laser.
Confirmation, to confirm the laser to show the present mode at the
next operation.
UP/DOWN, to change operating mode, parameter or DMX address.
OPERATION
USER MANUAL
16
SOUND ACTIVATED SHOW with single YELLOW
DISPALY STAND ALONE MODE PREPROGRAM EFFECT
Aut
Au1
Au2
Au3
Sou
So1
So2
So3
AUP
SOP
Attention In preprogrammed standalone MUSIC SHOW mode, the
AUTOMATIC SHOW with RGY colors
AUTOMATIC SHOW with single RED color
AUTOMATIC SHOW with single GREEN color
AUTOMATIC SHOW with single YELLOW color
SOUND ACTIVATED SHOW with RGY colors
SOUND ACTIVATED SHOW with single RED color
SOUND ACTIVATED SHOW with single GREEN color
Auto running pattern effect show
Sound activated pattern effect show
laser beam will be blank-out in 3 seconds without
AUDIO/MIC activated signal.
DMX MODE
Press FUNC to enter MODE selection
Till to LED panel shows 001
Press ENTER to confirm setting
The laser is working in DMX MODE.
With help of UP and DOWN button, the
DMX address could be set.
Attention In DMX MODE, once the DMX cable i s conn ected with l aser
and DMX controller, the DMX LED in front panel of
laser will be ON.
USER MANUAL
17
SLAVE MODE
Press FUNC to enter MODE selection
Till to LED panel shows SLA
Press ENTER to confirm setting
The laser is working in SLAVE MODE. Connect MASTER laser with several
SLAVE laser with DMX cable, SLAVE lasers are doing exactly the same laser
show as MASTER laser. Please check chapter for DMX cable connection for
referece.
REM MODE (Remote Optional)
Press FUNC to enter MODE selection
Till to LED panel shows REM
Press ENTER to confirm setting
Please check Remote Instruction for remote control details.
Attention In any standalone mode (excepted REM and SLA), press
ON/OFF
PATTERN MIRROR REVERSE SETTING
Press FUNC to enter MODE selection
Till to below LED display is
shown in LED panel and the
laser will show pattern right
side.
Press ENTER to confirm the
setting.
With help of UP button, the laser scanned world in x direction could be
reversed, as the graphic as below.
for 2 second to activate remote function.
USER MANUAL
18
seconds for activate REM mode.
sensitive.
With help of DOWN button, the laser
scanned world in y direction could be
reversed, as the graphic as below.
Attention Beside of LED programmed mirror reverse setting, the
laser scanned world could be set by ILDA control panel.
Remote Instruction
Button Function Description
In REM mode, to turn ON / OFF laser. In any
ON/OFF
standalone mode, excepted SLA mode, pressing 2
Sound Sensitivity
AUTO AUTO running show
MUSIC
SOUND activated show. The blue music LED
indicator is flashing when so un d sign al i s det ecte d.
In Sound Activated Show, press MUSIC + B +
“1~9” to do sensitivity setting, “9” is the most
USER MANUAL
19
Last PATTERN and current PATTERN cycle
COLOR
CHANGING
PATTERN
CHANGING
Cycle through Programmed Color, Color 3 & Color
2, Color 1
To show and change patterns
FIXED
PATTERN
PATTERN
REPEAT
Choose favorite PATTERN from 1 to 48.
repeating
Attention Any control or setting in remote will be saved in ram, until
the system is rebooted. The system is in AUTO show in
any first remote mode after reboot.
DMX Channels Chart
CHANNEL VALUE FUNCTION
CH 1
MODE
000-020
021-040 AUT
041-060 AU1
061-080 AU2
081-100 AU3
101-120 SOU
121-140 SO1
15W
±20°
Audio / Sound Activated
40mW 532nm Green CW
100mW 650nm Red CW
Class 3B
EN60825-1 2007
10~40℃
3 pins XLR Male/Female
Max 17 channels
See picture below
1.5Kg
Every information is subject to change without prior notice.
The avai lability of particular products may vary by region. Please check with the dealer.
Belangrijke veiligheidsinstructies
Dit apparaat is ingedeeld in de laserklasse 3B.
G
Voor het gebruik van laserapparatuur klasse 3B moet er een laserveiligheidsverantwoordelijke schriftelijk
worden aangesteld door de onderneming, en moet hij of zij tijdens het
bedrijf aanwezig zijn (voorschrift
BGV B2 van de Duitse beroepsvereniging).
Laserveiligheidsverantwoordelijken
moeten over voldoende deskundigheid beschikken!
G
Voor lasterapparatuur klasse 3B is
een keuring vereist!
Laserstraling
Vermijd blootstelling aan de straal
Laserklasse 3B
Conform DIN EN 60825-1: 2007
WAARSCHUWING De toegankelijke la-
serstraling is heel gevaarlijk voor het oog
en vaak ook voor de
huid. Rechtstreeks in
de straal kijken van
klasse 3B-lasers is
gevaarlijk. Een stralenbundel kan eventueel veilig via een
diffuse reflector worden bekeken.
Wichtige Sicherheitshinweise
Dieses Gerät ist der Laserklasse 3B
zugeordnet.
G
Für den Betrieb eines Lasers der
Klasse 3B muss ein Laserschutzbeauftragter vom Unternehmer schriftlich bestellt werden und während
des Betriebs anwesend sein
(Berufsgenossenschaftliche Vorschrift BGV B2).
Für Laser der Klasse 3B ist eine Abnahme erforderlich!
Laserstrahlung
Nicht dem Strahl aussetzen
Laser Klasse 3B
Nach DIN EN 60825-1: 2007
WARNUNG Die zugängliche Laser-
strahlung ist gefährlich
für das Auge, häufig auch
für die Haut. Das direkte
Blicken in den Strahl bei
Lasern der Klasse 3B ist
gefährlich. Ein Strahlbündel kann unter Um ständen sicher über
einen diffusen Reflektor
betrachtet werden.
This unit is classified as a class 3B
laser product.
G
When using a class 3B laser, the employer has to appoint a laser safety
officer in writing who has to be present during operation (BGV B2 = German Accident Prevention & Insurance Association regulation B2).
Laser safety officers must have the
requisite qualification!
G
An approval is required for class 3B
lasers!
WARNING The accessible laser
radiation is hazardous to
the eye, also frequently
to the skin. It is hazardous to look directly
into the beam of class 3B
lasers. It may be possible to view a beam safely
via a diffusing reflector.
Laser Radiation
Avoid exposure to the beam
Class 3B laser
According to DIN EN 60825-1: 2007
Conseils importants de sécurité
Cet appareil est classé comme produit
répondant à la classe laser 3B.
G
Pour le fonctionnement dʼun laser de
classe 3B, un responsable pour la
sécurité laser doit être désigné par
écrit par lʼemployeur, il doit être présent pendant le fonctionnement du
produit (réglementation allemande
de la prévention des accidents et association dʼassurances BGV B2).
Le responsable de la sécurité laser
doit avoir les qualifications requises !
G
Pour des lasers de classe 3B, une
autorisation est nécessaire !
Rayonnement laser
Eviter toute exposition au faisceau
Laser Classe 3B
Selon DIN EN 60825-1: 2007
AVERTISSEMENT
Le rayonnement laser
accessible est dangereux pour les yeux,
souvent aussi pour la
peau. Regarder directement dans le faisceau de lasers de
classe 3B est dangereux. Eventuellement,
il nʼest pas dangereux
de regarder un faisceau via un réflecteur
diffuseur.
Importanti avvertenze di sicurezza
Questo apparecchio è assegnato alla
classe laser 3B.
G
Per lʼimpiego di un laser della classe
3B,lʼimprenditore deve nominare
per iscritto un tecnico di sicurezza
laser che deve essere presente durante lʼuso (norma della Cassa previdenza contro gli infortuni sul lavoro
BGV B2).
I tecnici di sicurezza laser devono
possedere delle conoscenze sufficienti della materia!
G
Per i laser della classe 3B è obbligatorio un collaudo!
AVVERTIMENTO La radiazione acces-
sibile del laser è pericolosa per lʼocchio,
spesso anche per la
pelle. Guardare direttamente nel raggio è
pericoloso nel caso
dei laser della classe
3B. Un fascio di raggi
può essere guardato
eventualmente con sicurezza per mezzo di
un riflettore diffuso.
Radiazione laser
Non esporsi al raggio
Laser classe 3B
Secondo DIN EN 60825-1: 2007
DA CHGBFB CHINLB
Notas de Seguridad Importantes
Este producto está clasificado como
láser de clase 3B.
G
Cuando se utiliza un láser de la clase
3B, el dueño tiene que designar por
escrito un encargado para la seguridad del láser que deberá estar presente siempre durante el funcionamiento (BGV B2 = Regulación B2 de
la Asociación de Aseguradoras y
Prevención de Accidentes Alemana).
¡Los encargados de la seguridad
láser deben tener la cualificación necesaria!
G
¡Se necesita una autorización para
un láser de la clase 3B!
ADVERTENCIA La radiación láser a la
que se puede acceder
es peligrosa para el ojo
humano y a menudo
también para la piel. Es
peligroso mirar directamente hacia el haz de
un láser de la clase 3B.
Existe la posibilidad de
ver un haz con seguridad mediante un reflector de difusión.
Podczas wykorzystywania laserów
klasy 3B, należy zapoznać się z obowiązującymi dyrektywami (w Niemczech: BGV B2 = German Accident
Prevention & Insurance Association
regulation B2).
Osoby obsługujące urządzenia laserowe muszą posiadać odpowiednie
kwalifikacje!
G
Stosowanie laserów klasy 3B wymaga zezwolenia!
Promieniowanie laserowe
Unikać kontaktu z promieniami
Klasa lasera: 3B
Zgodnie z DIN EN 60825-1: 2007
UWAGA Wiązka laserowa jest bar-
dzo szkodliwa dla ludzkiego oka, a czasem również skóry. Patrzenie bezpośrednio na wiązkę lasera klasy 3B może być
niebezpieczne. W razie
konieczności wykorzystać reflektory rozpraszające.
Vigtige sikkerhedsanvisninger
Denne enhed er klassificeret som en
class 3B laser.
G
Når en class 3B laser benyttes, skal
en sikkerhedsansvarlig person skriftligt være udpeget og denne skal altid
være tilstede under brugen af laseren. (BGV B2).
Den sikkerhedsansvarlige person
skal have den nødvendige uddannelse!
G
En class 3B laser kræver særlig godkendelse fra myndighederne!
Laserstråling
Undgå kontakt med laserstrålerne
Class 3B laser
DIN EN 60825-1: 2007
ADVARSEL Laserstråling er skadelig
for øjne og hud. Det er
skadeligt, at kigge direkte ind i laserstrålen, på
en class 3B laser. Stråler
er ikke skadelige, hvis
der er monteret en reflekterende diffuser.
Viktig säkerhetsinformation
Denna enhet är klassad som en
klass 3B laser produkt.
G
När du använder en klass 3B laser,
ska arbetsgivaren skriftligen utse en
tjänsteman för lasersäkerhet som
måste vara närvarande under drift
(BGV B2 = German Accident Prevention & Insurance Association regulation B2).
Laserskyddsombud ska ha erforderlig kompetens!
G
Ett godkännande krävs för klass 3B
laser!
Laserstrålning
Undvik exponering från laserstrålen
Klass 3B laser
Enligt DIN EN 60825-1: 2007
VARNING Den åtkomliga laserstrål-
ningen är farligt för ögat,
och även oftaför huden.
Det är farligt att titta direkt in i strålen av klass
3B lasrar. Det kan vara
möjligt att titta på en laserstråle på ett säkert
sätt via en diffunderande
reflektor.
Turvallisuudesta
Tuote on luokiteltu 3B-luokan laserlaitteeksi.
G
3B-luokan laserin turvallisesta käytöstä vastaava henkilö on nimettävä
kirjallisesti, ja hänen on oltava paikalla laitetta käytettäessä (vakuutusyhtiöiden vastuuvakuutussäännös
BGV B2).
Laserin käytöstä vastaavalla henkilöllä on oltava tarvittava pätevyys!
G
3B-luokan lasereille vaaditaan hyväksyntä!
Lasersäteily
Vältä altistumista säteelle
3B-luokan laser
DIN EN 60825-1: 2007 mukaan
HUOMIO Lasersäteilylle altistumi-
nen on haitallista silmille
ja usein toistettuna myös
iholle. On haitallista katsoa suoraan 3B-luokan
lasersäteeseen. Saattaa
olla mahdollista katsoa
sädettä turvallisesti tummennetun lasin kautta.
EPLDKS
FIN
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.