IMC Networks MOR-F-632-120-EB82 User Manual

IE-iMcV-E1-Mux/4
Operation Manual
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class B
limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B
prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
Warranty
IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set forth below.
At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer.
To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization (RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S and Canada) or (949) 465­3000 or FAX: (949) 465-3020. The end-user shall return the defective product to IMC Networks, freight, customs and handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product, whether or not IMC Networks has been advised of the possibility of such loss or damage.
EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON, INCLUDING EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE
INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE.
Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes, errors or omissions.
ii
Table of Contents
FCC Radio Frequency Interference Statement ------------------------------------------------- ii Warranty ----------------------------------------------------------------------------------------------- ii About the IE-iMcV-E1-Mux/4 ---------------------------------------------------------------------- 1
Managed Modules----------------------------------------------------------------------------- 2 Port Interfaces ---------------------------------------------------------------------------------- 2
LED
Operation ---------------------------------------------------------------------------------------- 5
10/100BaseT Connector --------------------------------------------------------------------- 5 E1 RJ-48 Connectors -------------------------------------------------------------------------- 6
SFP
Ports ----------------------------------------------------------------------------------------- 6
Connector Pinout and DIP Switch Assignments ----------------------------------------------- 7
DIP Switch Assignments---------------------------------------------------------------------- 7 10/100BaseT Ethernet Mating Connector Pinout--------------------------------------- 8 E1 Port Mating Connector Pinout ---------------------------------------------------------- 8 RS-232 Port Mating Connector Pinout---------------------------------------------------- 9
RS-232 Serial Console Port ------------------------------------------------------------------ 9 Installation Instructions -----------------------------------------------------------------------------10 Configuration Options------------------------------------------------------------------------------11
Ethernet Line Setup ------------------------------------------------------------------------- 11
Packet Size ------------------------------------------------------------------------------------ 11
Auto Negotiation----------------------------------------------------------------------------- 11
Forcing the Speed, Duplex Mode, and Flow Control-------------------------------- 11
FX LinkLoss and
FX LinkLoss (FXLL) --------------------------------------------------------------------------- 12
Link Fault Pass-Through (
E1 Ports Setup -------------------------------------------------------------------------------- 12
Alarm Level ----------------------------------------------------------------------------------- 12
Loopback -------------------------------------------------------------------------------------- 13 Console Screens -------------------------------------------------------------------------------------14
Login Screen ------------------------------------------------------------------------------------- 14 Main Menu--------------------------------------------------------------------------------------- 14
Menu Options-------------------------------------------------------------------------------- 15
Unit Configuration Screen -------------------------------------------------------------------- 16 Port Alarm Status Screen ---------------------------------------------------------------------- 16
SFP
Line Status Screen ------------------------------------------------------------------------- 17 Ethernet Port Configuration Screen --------------------------------------------------------- 18 Ethernet Port Status Screen ------------------------------------------------------------------- 18 E1 Port Configuration Screen----------------------------------------------------------------- 19 E1 Port Status Screen--------------------------------------------------------------------------- 20
Troubleshooting -------------------------------------------------------------------------------------21
Fiber Optic Port Verification------------------------------------------------------------------ 22 E1 Port Verification ----------------------------------------------------------------------------- 23
LFPT
----------------------------------------------------------------------- 11
LFPT
)------------------------------------------------------------ 12
iii
Normal Operation ------------------------------------------------------------------------------ 24 Fiber Optic Cleaning Guidelines------------------------------------------------------------- 25
Electrostatic Discharge Precautions --------------------------------------------------------------26 Specifications -----------------------------------------------------------------------------------------27 Standards/Compliance -----------------------------------------------------------------------------27 IMC Networks Technical Support----------------------------------------------------------------28 Definition of Terms/Acronyms --------------------------------------------------------------------29 Certifications -----------------------------------------------------------------------------------------31
iv
About the IE-iMcV-E1-Mux/4
Overview
The IE-iMcV-E1-Mux/4 is a media converter that transports four independent E1 lines
1+1
over an existing single (or dual, “ operating at an effective rate of 150Mbps. One serial link (RS-232) and one Ethernet (10/100BaseT) connection are also multiplexed onto the fiber link(s). Each of these communication channels is transported end-to-end at full wire speed with very low latencies.
The serial link can be used for extending an independent RS-232 interface to the
POP
remote supports any data rate up to 250K baud. In addition, each unit also supports an RS­232 console port for local configuration by technical support personnel. Both of these serial links are used for end-to-end system management, fault detection/isolation and system diagnostics.
The IE-iMcV-E1-Mux/4 provides fault indications on the E1 and fiber links resulting from real-time active faults. The equipment detects both E1 and fiber well as degraded E1 or fiber lines. The unit will automatically forward the remote unit after detecting an line. Severe receive optical link failures will result in the automatic generation of signaling onto the E1 lines connected to the unit receiving the corrupted optical signal.
location for use in managing or controlling other devices at the
”) standard 155Mbps-capable fiber optic line
POP
LOS
events as
AIS
signaling to
LOS
(Loss Of Signal) condition on any incoming E1
and
AIS
CV
In addition, calculations for the optical line are constantly being performed by circuitry within the unit's optical receiver. Error conditions are displayed on the unit’s front panel indicators and reported to system management software (if equipped) where more detailed error information can be displayed on the user’s
Systems equipped with reliability of a protected fiber link and the system’s ability to automatically switch to the “best” fiber line should one line become impaired or fail. This automatic switchover capability is designed to occur rapidly (<50 milliseconds), minimizing data loss and system down time. In addition, automatic switchover can be overridden; this allows the end-user to force the unit to receive on a specific optical line if desired
The IE-iMcV-E1-Mux/4 offers the following features:
• Four E1 ports on RJ-48 connectors with surge protection
One full bandwidth Ethernet 10/100BaseT port
1+1
protection switching via two
DDMI
One end-to-end serial RS-232 port on an RJ-48 connector
(Code Violation) errors are detected on all incoming E1 lines and
GUI
.
1+1
fiber redundancy can benefit from the enhanced
SFP
-based optical ports
supported on
SFP
ports
LED
BER
1
• Local
CLI
management console port on a Mini Jack connector
Remote management capability through iMediaChassis series
AIS
generation on signal loss on all E1 interfaces
SNMP MDI/MDIX automatic Ethernet port switching
Alarm TRAP reporting in managed chassis
The IE-iMcV-E1-Mux/4 module is a dual-wide iMcV module.
Compatible chassis include the following:
• iMediaChassis series
• MediaChassis series
• IE-MediaChassis series
Product Application
The
IE-iMcV-E1-Mux/4 delivers 4 E1 lines to a customer's site over a protected, dedicated fiber line. In addition, one serial RS-232 line and one 10/100BaseT Ethernet line can be carried at the same time. All circuits run at full line rates with no interaction.
ISP Internet
TDM Network
PSTN
Local Far End
10/100BaseT
(1 Port)
E1
(4 port)
Console
E1-Mux
(Network)
Host
Dedicated
Fiber
Dedicated
Fiber
Protection
(1+1)
E1-Mux
(Subscriber)
Remote
10/100BaseT
(1 Port)
E1
(4 Port)
Serial PortSerial Port
Console
Customer
LAN
Customer
PABX
Console RS232
Remote Far End
Managed Modules
The
IE-iMcV-E1-Mux/4 modules are installed as a Host/Remote pair. Host or Remote configuration is selected by an onboard DIP Switch setting. The Host/Remote pair can be remotely managed when the HOST is installed in an iMediaChassis with an
SNMP
Management Module.
Port Interfaces
A fully-configured IE-iMcV-E1-Mux/4 includes the following ports:
• Four E1 ports on RJ-48 connectors short haul
• One 10/100BaseT twisted pair Ethernet port
• One fiber
SFP
port (requires
SFP
/155-ED module for each port)
2
• Optional
SFP
port for optical
1+1
protection.
• One Mini Jack serial RS-232 serial console port
• One user serial RS-232 data port (RJ-45)
The IE-iMcV-E1-Mux/4 is easily configured by using the serial console port connection or through an
SNMP
management application such as iView².
Console Serial Port Connection
10/100BaseT
Connector
RS-232
Connector
E1 RJ-48
Connectors
SFP
Ports
Console
The IE-iMcV-E1-Mux/4 includes a console serial port. To establish a link between a module's console port and a local PC, connect the Mini Jack to DB9 adapter that is included with the IMC module. This RS-232 serial connection provides access to the
CLI
IE-iMcV-E1-Mux/4 module
VT-100 emulation, 38.4K baud, 8 data bits, 1 stop bit, no parity control
. Under the VT-100 emulation, set the backspace key to send delete.
configuration screens. Set the computer/terminal for
and
no flow
3
iView² Management Software
iView² is the IMC Networks management software that features a GUI and gives network managers the ability to monitor and control manageable IMC Networks products.
iView² is available in several versions, including WebServer version 3.0, and can also function as a snap-in module for HP OpenView Network Node Manager and other third party SNMP Management software. For assistance in selecting the right version of iView² for your operating system, please visit:
http://www.imcnetworks.com/products/iview2.cfm
2
iView
supports the following platforms:
• Windows 2000
• Windows XP
• Windows Vista
• Windows 7
SNMP
Please see the
Management Module for software configuration options.
4
LED
Operation
10/100BaseT
Connector
Connector
RS-232
E1 RJ-48
Connectors
SFP
Ports
The IE-iMcV-E1-Mux/4 features diagnostic
10/100BaseT Connector
LNK:
• OFF when port is not linked/connected
FDX:
• Glows green when link is established
• Blinks green during data activity
• OFF when port is not connected or when running at half-
duplex
• Glows yellow when port is running at full duplex
• Blinks yellow when collisions occur
LED
s as explained below.
5
E1 RJ-48 Connectors
ALARM:
• OFF during normal operation
• Blinks red+green simultaneously
when line at far end of the optical line
• Glows red+green when loss of
service ( continuous bit errors are detected on the E1 line at far end of the optical line
• Blinks red when local CV errors
detected on E1 line.
• Glows red when
the local E1 line, OR when continuous errors are detected on the local E1 line
SFP
Ports
CV
errors detected on the E1
LOS
) is detected, OR
LOS
detected on
STAT:
• Glows green
during normal operation
• Glows
red+green when out-of-service or when the port is in a loopback or test state
• Glows red when
the Host to Remote fiber link(s) is down or badly corrupted
One model offers two second model offers one
ACT:
• Glows green when the
• OFF when the
• Glows red+green when the
be the active receive line
LNK:
• Glows green when there is a valid link
• Glows red when a loss of optical signal occur,
continuous optical bit errors
RAI
:
• Off when no remote defects are detected
• Glows red+green when remote
MSA
:
• Off when
• Glows green when no
• Glows red+green when
at remote end
• Glows red when
detected locally, i.e., when the speed is not at 155Mbps
SFP
(A and B) ports for
SFP
without protection.
SFP
port is the active receive line.
SFP
is not the receive line
SFP
SFP
is not an IMC Networks
SFP
alarms are detected
SFP
alarms or defects are detected
SFP
alarms or misconfigurations are
1+1
protection; a
port is manually forced to
LOF
, or with
LOS
or
BER
detected
SFP
SFP
is missing, or when
SFP
6
Connector Pinout and DIP Switch Assignments
DIP Switch Assignments
A single 10-position DIP Switch is located on the unit to set the configuration. The switch positions are defined as follows:
Switch # Function Settings Factory Default
1 Host/Remote OFF = Host,
OFF
ON = Remote 2 Reserved OFF OFF 3 Reserved OFF OFF 4 Reserved OFF OFF 5 Reserved OFF OFF 6 Reserved OFF OFF 7 Reserved OFF OFF 8 Reserved OFF OFF 9 Reserved OFF OFF
10 Reserved OFF OFF
NOTE
Switch #1 must be set to ON at the Remote location. Switches #2 through #10 are reserved for factory use only and must be OFF for proper operation.
7
Loading...
+ 25 hidden pages